메뉴 건너뛰기




Volumn 11, Issue 1, 2014, Pages

Time-division multiplexing for myoelectric closed-loop control using electrotactile feedback

Author keywords

Closed loop control; Feedback window; Sensory feedback in prosthetics; Sensory substitution; Time division multiplexing

Indexed keywords

ADULT; ARTICLE; CONCENTRIC STIMULATION ELECTRODE; CONTROLLED STUDY; CORRELATION COEFFICIENT; CROSS CORRELATION COEFFICIENT; ELECTRODE; ELECTROMYOGRAPH ELECTRODE; ELECTROMYOGRAPHY; ELECTROSTIMULATION; ELECTROTACTILE FEEDBACK; EYE TRACKING; HUMAN; HUMAN EXPERIMENT; MYOELECTRIC CLOSED LOOP CONTROL; MYOELECTRIC CONTROL; NEUROMUSCULAR STIMULATOR; NORMAL HUMAN; SIGNAL PROCESSING; TACTILE FEEDBACK; TACTILE STIMULATION; TASK PERFORMANCE; TIME DIVISION MULTIPLEXING; YOUNG ADULT; COMPUTER INTERFACE; PHYSIOLOGY; PROSTHESIS; SENSORY FEEDBACK; SKELETAL MUSCLE; TOUCH;

EID: 84908127833     PISSN: None     EISSN: 17430003     Source Type: Journal    
DOI: 10.1186/1743-0003-11-138     Document Type: Article
Times cited : (37)

References (29)
  • 1
    • 0019300990 scopus 로고
    • Closed-loop control in prosthetic systems: Historical perspective
    • Childress DS: Closed-loop control in prosthetic systems: historical perspective. Ann Biomed Eng 1980, 8:293-303.
    • (1980) Ann Biomed Eng , vol.8 , pp. 293-303
    • Childress, D.S.1
  • 5
    • 0018355380 scopus 로고
    • A myoelectrically-controlled prosthesis with sensory feedback
    • Shannon GF: A myoelectrically-controlled prosthesis with sensory feedback. Med Biol Eng Comput 1979, 17:73-80.
    • (1979) Med Biol Eng Comput , vol.17 , pp. 73-80
    • Shannon, G.F.1
  • 6
    • 33749435189 scopus 로고    scopus 로고
    • Design and evaluation of a low-cost force feedback system for myoelectric prosthetic hands
    • Pylatiuk C, Kargov A, Schulz S: Design and evaluation of a low-cost force feedback system for myoelectric prosthetic hands. JPO J Prosthetics Orthot 2006, 18:57-61.
    • (2006) JPO J Prosthetics Orthot , vol.18 , pp. 57-61
    • Pylatiuk, C.1    Kargov, A.2    Schulz, S.3
  • 7
    • 80054943371 scopus 로고    scopus 로고
    • The role of feed-forward and feedback processes for closed-loop prosthesis control
    • Saunders I, Vijayakumar S: The role of feed-forward and feedback processes for closed-loop prosthesis control. J Neuroeng Rehabil 2011, 8:60.
    • (2011) J Neuroeng Rehabil , vol.8 , pp. 60
    • Saunders, I.1    Vijayakumar, S.2
  • 10
    • 84856201341 scopus 로고    scopus 로고
    • A miniature vibrotactile sensory substitution device for multifingered hand prosthetics
    • Cipriani C, D'Alonzo M, Carrozza MC: A miniature vibrotactile sensory substitution device for multifingered hand prosthetics. IEEE Trans Biomed Eng 2012, 59:400-408.
    • (2012) IEEE Trans Biomed Eng , vol.59 , pp. 400-408
    • Cipriani, C.1    D'Alonzo, M.2    Carrozza, M.C.3
  • 11
    • 78751506000 scopus 로고    scopus 로고
    • A tactile display system for hand prostheses to discriminate pressure and individual finger localization
    • Antfolk C, Balkenius C: A tactile display system for hand prostheses to discriminate pressure and individual finger localization. J Med Biol Eng 2010, 30:355-360.
    • (2010) J Med Biol Eng , vol.30 , pp. 355-360
    • Antfolk, C.1    Balkenius, C.2
  • 13
    • 0018412407 scopus 로고
    • Sensory feedback for artificial limbs
    • Shannon GF: Sensory feedback for artificial limbs. Med Prog Technol 1979, 6:73-79.
    • (1979) Med Prog Technol , vol.6 , pp. 73-79
    • Shannon, G.F.1
  • 14
    • 0020116505 scopus 로고
    • Electrocutaneous stimulation for sensory communication in rehabilitation engineering
    • Szeto AY, Saunders FA: Electrocutaneous stimulation for sensory communication in rehabilitation engineering. IEEE Trans Biomed Eng 1982, 29:300-308.
    • (1982) IEEE Trans Biomed Eng , vol.29 , pp. 300-308
    • Szeto, A.Y.1    Saunders, F.A.2
  • 15
    • 0033822727 scopus 로고    scopus 로고
    • EMG signals detection and processing for on-line control of functional electrical stimulation
    • Frigo C, Ferrarin M, Frasson W, Pavan E, Thorsen R: EMG signals detection and processing for on-line control of functional electrical stimulation. J Electromyogr Kinesiol 2000, 10:351-360.
    • (2000) J Electromyogr Kinesiol , vol.10 , pp. 351-360
    • Frigo, C.1    Ferrarin, M.2    Frasson, W.3    Pavan, E.4    Thorsen, R.5
  • 16
    • 84908144749 scopus 로고    scopus 로고
    • Closed-loop control of myoelectric prostheses with electrotactile feedback: Influence of blanking for removal of the stimulation artifact
    • accepted
    • Hartmann C, Dosen S, Amsuess S, Farina D: Closed-loop control of myoelectric prostheses with electrotactile feedback: influence of blanking for removal of the stimulation artifact. IEEE Trans Neural Syst Rehabil Eng 2014, (accepted).
    • (2014) IEEE Trans Neural Syst Rehabil Eng
    • Hartmann, C.1    Dosen, S.2    Amsuess, S.3    Farina, D.4
  • 17
    • 0019620730 scopus 로고
    • Electrical stimulation and myoelectric control. A theoretical and applied study relevant to prosthesis sensory feedback
    • Almström C, Anani A, Herberts P, Körner L: Electrical stimulation and myoelectric control. A theoretical and applied study relevant to prosthesis sensory feedback. Med Biol Eng Comput 1981, 19:645-653.
    • (1981) Med Biol Eng Comput , vol.19 , pp. 645-653
    • Almström, C.1    Anani, A.2    Herberts, P.3    Körner, L.4
  • 20
    • 0016585084 scopus 로고
    • Electrocutaneous feedback for artificial limbs. Summary progress report. February 1, 1974, through July 31, 1975
    • Prior RE, Lyman J: Electrocutaneous feedback for artificial limbs. Summary progress report. February 1, 1974, through July 31, 1975. Bull Prosthet Res 1975, (10-24):3-37.
    • (1975) Bull Prosthet Res , Issue.10-24 , pp. 3-37
    • Prior, R.E.1    Lyman, J.2
  • 21
    • 0007463626 scopus 로고
    • Theory of manual vehicular control
    • McRuer D, Weir D: Theory of manual vehicular control. IEEE Trans Man Mach Syst 1969, 10:257-291.
    • (1969) IEEE Trans Man Mach Syst , vol.10 , pp. 257-291
    • McRuer, D.1    Weir, D.2
  • 22
    • 0018195514 scopus 로고
    • Tactile information processing by human operators in control systems
    • Schmid HP, Bekey GA: Tactile information processing by human operators in control systems. IEEE Trans Syst Man Cybern 1978, 8:860-866.
    • (1978) IEEE Trans Syst Man Cybern , vol.8 , pp. 860-866
    • Schmid, H.P.1    Bekey, G.A.2
  • 23
    • 0015486934 scopus 로고
    • Tracking performance with visual, auditory, or electrocutaneous displays
    • Hofmann MA, Heimstra NW: Tracking performance with visual, auditory, or electrocutaneous displays. Hum Factors 1972, 14:131-138.
    • (1972) Hum Factors , vol.14 , pp. 131-138
    • Hofmann, M.A.1    Heimstra, N.W.2
  • 27
    • 84896477498 scopus 로고    scopus 로고
    • HyVE: Hybrid vibro-electrotactile stimulation for sensory feedback and substitution in rehabilitation
    • D'Alonzo M, Dosen S, Cipriani C, Farina D: HyVE: hybrid vibro-electrotactile stimulation for sensory feedback and substitution in rehabilitation. IEEE Trans Neural Syst Rehabil Eng 2014, 22(2):290-301.
    • (2014) IEEE Trans Neural Syst Rehabil Eng , vol.22 , Issue.2 , pp. 290-301
    • D'Alonzo, M.1    Dosen, S.2    Cipriani, C.3    Farina, D.4
  • 28
  • 29
    • 77955069255 scopus 로고    scopus 로고
    • Intermittent stimulation delays adaptation to electrocutaneous sensory feedback
    • Buma DG, Buitenweg JR, Veltink PH: Intermittent stimulation delays adaptation to electrocutaneous sensory feedback. IEEE Trans Neural Syst Rehabil Eng 2007, 15:435-441.
    • (2007) IEEE Trans Neural Syst Rehabil Eng , vol.15 , pp. 435-441
    • Buma, D.G.1    Buitenweg, J.R.2    Veltink, P.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.