메뉴 건너뛰기




Volumn 34, Issue 8, 2014, Pages 646-652

The influence of nerve conduits diameter in motor nerve recovery after segmental nerve repair

Author keywords

[No Author keywords available]

Indexed keywords

COLLAGEN;

EID: 84907807367     PISSN: 07381085     EISSN: 10982752     Source Type: Journal    
DOI: 10.1002/micr.22312     Document Type: Article
Times cited : (15)

References (31)
  • 1
    • 0347984996 scopus 로고    scopus 로고
    • Bunge memorial lecture. Nerve injury and repair - A challenge to the plastic brain
    • Lundborg G. Richard P. Bunge memorial lecture. Nerve injury and repair - A challenge to the plastic brain. J Peripher Nerv Syst 2003;8:209-226.
    • (2003) J Peripher Nerv Syst , vol.8 , pp. 209-226
    • Lundborg, G.1    Richard, P.2
  • 3
    • 84858590001 scopus 로고    scopus 로고
    • Return of motor function after segmental nerve loss in a rat model: Comparison of autogenous nerve graft, collagen conduit, and processed allograft (AxoGen)
    • Giusti G, Willems WF, Kremer T, Friedrich PF, Bishop AT, Shin AY. Return of motor function after segmental nerve loss in a rat model: Comparison of autogenous nerve graft, collagen conduit, and processed allograft (AxoGen). J Bone Joint Surg 2012;94:410-417.
    • (2012) J Bone Joint Surg , vol.94 , pp. 410-417
    • Giusti, G.1    Willems, W.F.2    Kremer, T.3    Friedrich, P.F.4    Bishop, A.T.5    Shin, A.Y.6
  • 4
  • 5
    • 84863716995 scopus 로고    scopus 로고
    • The long-term functional recovery of repair of sciatic nerve transection with biogenic conduits
    • Penna V, Wewetzer K, Munder B, Stark GB, Lang EM. The long-term functional recovery of repair of sciatic nerve transection with biogenic conduits. Microsurgery 2012;32:377-382.
    • (2012) Microsurgery , vol.32 , pp. 377-382
    • Penna, V.1    Wewetzer, K.2    Munder, B.3    Stark, G.B.4    Lang, E.M.5
  • 6
    • 0034193047 scopus 로고    scopus 로고
    • A 25-year perspective of peripheral nerve surgery: Evolving neuroscientific concepts and clinical significance
    • Lundborg G. A 25-year perspective of peripheral nerve surgery: Evolving neuroscientific concepts and clinical significance. J Hand Surg [Am] 2000;25:391-414.
    • (2000) J Hand Surg [Am] , vol.25 , pp. 391-414
    • Lundborg, G.1
  • 8
    • 0036169560 scopus 로고    scopus 로고
    • Clinical use of nerve conduits in peripheralnerve repair: Review of the literature
    • Meek MF, Coert JH. Clinical use of nerve conduits in peripheralnerve repair: Review of the literature. J Reconstr Microsurg 2002;18:97-109.
    • (2002) J Reconstr Microsurg , vol.18 , pp. 97-109
    • Meek, M.F.1    Coert, J.H.2
  • 9
    • 0025612386 scopus 로고
    • Progress in peripheral nerve reconstruction
    • Millesi H. Progress in peripheral nerve reconstruction. World J Surg 1990;14:733-747.
    • (1990) World J Surg , vol.14 , pp. 733-747
    • Millesi, H.1
  • 12
    • 36749025068 scopus 로고    scopus 로고
    • A comparison of polyglycolic acid versus type 1 collagen bioabsorbable nerve conduits in a rat model: An alternative to autografting
    • Waitayawinyu T, Parisi DM, Miller B, Luria S, Morton HJ, Chin SH, Trumble TE. A comparison of polyglycolic acid versus type 1 collagen bioabsorbable nerve conduits in a rat model: An alternative to autografting. J Hand Surg [Am] 2007;32:1521-1529.
    • (2007) J Hand Surg [Am] , vol.32 , pp. 1521-1529
    • Waitayawinyu, T.1    Parisi, D.M.2    Miller, B.3    Luria, S.4    Morton, H.J.5    Chin, S.H.6    Trumble, T.E.7
  • 13
    • 70349232867 scopus 로고    scopus 로고
    • Treatment of a segmental nerve defect in the rat with use of bioabsorbable synthetic nerve conduits: A comparison of commercially available conduits
    • Shin RH, Friedrich PF, Crum BA, Bishop AT, Shin AY. Treatment of a segmental nerve defect in the rat with use of bioabsorbable synthetic nerve conduits: a comparison of commercially available conduits. J Bone Joint Surg 2009;91:2194-2204.
    • (2009) J Bone Joint Surg , vol.91 , pp. 2194-2204
    • Shin, R.H.1    Friedrich, P.F.2    Crum, B.A.3    Bishop, A.T.4    Shin, A.Y.5
  • 14
    • 84883598868 scopus 로고    scopus 로고
    • Histologic and functional outcomes of nerve defects treated with acellular allograft versus cabled autograft in a rat model
    • Tang P, Kilic A, Konopka G, Regalbuto R, Akelina Y, Gardner T. Histologic and functional outcomes of nerve defects treated with acellular allograft versus cabled autograft in a rat model. Microsurgery 2013;33:460-467.
    • (2013) Microsurgery , vol.33 , pp. 460-467
    • Tang, P.1    Kilic, A.2    Konopka, G.3    Regalbuto, R.4    Akelina, Y.5    Gardner, T.6
  • 15
    • 58149380325 scopus 로고    scopus 로고
    • The clinical use of artificial nerve conduits for digital nerve repair: A prospective cohort study and literature review
    • Lohmeyer JA, Siemers F, Machens HG, Mailander P. The clinical use of artificial nerve conduits for digital nerve repair: A prospective cohort study and literature review. J Reconstruc Microsurg 2009;25:55-61.
    • (2009) J Reconstruc Microsurg , vol.25 , pp. 55-61
    • Lohmeyer, J.A.1    Siemers, F.2    Machens, H.G.3    Mailander, P.4
  • 17
    • 35349005760 scopus 로고    scopus 로고
    • Differences between the effect of anisotropic and isotropic laminin and nerve growth factor presenting scaffolds on nerve regeneration across long peripheral nerve gaps
    • Dodla MC, Bellamkonda RV. Differences between the effect of anisotropic and isotropic laminin and nerve growth factor presenting scaffolds on nerve regeneration across long peripheral nerve gaps. Biomaterials 2008;29:33-46.
    • (2008) Biomaterials , vol.29 , pp. 33-46
    • Dodla, M.C.1    Bellamkonda, R.V.2
  • 19
    • 0031215049 scopus 로고    scopus 로고
    • Gel matrix vehicles for growth factor application in nerve gap injuries repaired with tubes: A comparison of biomatrix, collagen, and methylcellulose
    • Wells MR, Kraus K, Batter DK, Blunt DG, Weremowitz J, Lynch SE, Antoniades HN, Hansson HA. Gel matrix vehicles for growth factor application in nerve gap injuries repaired with tubes: A comparison of biomatrix, collagen, and methylcellulose. Exp Neurol 1997;146:395-402.
    • (1997) Exp Neurol , vol.146 , pp. 395-402
    • Wells, M.R.1    Kraus, K.2    Batter, D.K.3    Blunt, D.G.4    Weremowitz, J.5    Lynch, S.E.6    Antoniades, H.N.7    Hansson, H.A.8
  • 20
    • 12444305013 scopus 로고    scopus 로고
    • Peripheral nerve regeneration with sustained release of poly(phosphoester) microencapsulated nerve growth factor within nerve guide conduits
    • Xu X, Yee WC, Hwang PY, Yu H, Wan AC, Gao S, Boon KL, Mao HQ, Leong KW, Wang S. Peripheral nerve regeneration with sustained release of poly(phosphoester) microencapsulated nerve growth factor within nerve guide conduits. Biomaterials 2003;24:2405-2412.
    • (2003) Biomaterials , vol.24 , pp. 2405-2412
    • Xu, X.1    Yee, W.C.2    Hwang, P.Y.3    Yu, H.4    Wan, A.C.5    Gao, S.6    Boon, K.L.7    Mao, H.Q.8    Leong, K.W.9    Wang, S.10
  • 22
    • 0029017873 scopus 로고
    • Monkey median nerve repaired by nerve graft or collagen nerve guide tube
    • Archibald SJ, Shefner J, Krarup C, Madison RD. Monkey median nerve repaired by nerve graft or collagen nerve guide tube. J Neurosci 1995;15(5 Part 2):4109-4123.
    • (1995) J Neurosci , vol.15 , Issue.5 , pp. 4109-4123
    • Archibald, S.J.1    Shefner, J.2    Krarup, C.3    Madison, R.D.4
  • 24
    • 68749088467 scopus 로고    scopus 로고
    • Collagen nerve conduits promote enhanced axonal regeneration, schwann cell association, and neovascularization compared to silicone conduits
    • Kemp SW, Syed S, Walsh SK, Zochodne DW, Midha R. Collagen nerve conduits promote enhanced axonal regeneration, schwann cell association, and neovascularization compared to silicone conduits. Tissue Eng Part A 2009;8:1975-1988.
    • (2009) Tissue Eng Part A , vol.8 , pp. 1975-1988
    • Kemp, S.W.1    Syed, S.2    Walsh, S.K.3    Zochodne, D.W.4    Midha, R.5
  • 26
    • 1942532019 scopus 로고    scopus 로고
    • Confidence intervals illuminate absence of evidence
    • Altman D, Bland JM. Confidence intervals illuminate absence of evidence. BMJ 2004;328:1016-1017.
    • (2004) BMJ , vol.328 , pp. 1016-1017
    • Altman, D.1    Bland, J.M.2
  • 27
    • 84971580244 scopus 로고
    • Absence of evidence is not evidence of absence
    • Altman DG, Bland JM. Absence of evidence is not evidence of absence. BMJ 1995;311:485.
    • (1995) BMJ , vol.311 , pp. 485
    • Altman, D.G.1    Bland, J.M.2
  • 28
    • 0024449466 scopus 로고
    • Reliability of sciatic function index in assessing nerve regeneration across a 1 cm gap
    • Shenaq JM, Shenaq SM, Spira M. Reliability of sciatic function index in assessing nerve regeneration across a 1 cm gap. Microsurgery 1989;10:214-219.
    • (1989) Microsurgery , vol.10 , pp. 214-219
    • Shenaq, J.M.1    Shenaq, S.M.2    Spira, M.3
  • 30
    • 0029904013 scopus 로고    scopus 로고
    • Sciatic function index, nerve conduction tests, muscle contraction, and axon morphometry as indicators of regeneration
    • discussion 1272-1264
    • Kanaya F, Firrell JC, Breidenbach WC. Sciatic function index, nerve conduction tests, muscle contraction, and axon morphometry as indicators of regeneration. Plastic and reconstructive surgery 1996;98:1264-1271, discussion 1272-1264.
    • (1996) Plastic and Reconstructive Surgery , vol.98 , pp. 1264-1271
    • Kanaya, F.1    Firrell, J.C.2    Breidenbach, W.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.