메뉴 건너뛰기




Volumn 244, Issue , 2014, Pages 92-101

Method development and validation for simultaneous quantification of 15 drugs of abuse and prescription drugs and 7 of their metabolites in whole blood relevant in the context of driving under the influence of drugs--Usefulness of multi-analyte calibration

Author keywords

DUID; LC MS MS; Multi analyte approach; Validation

Indexed keywords

3,4 METHYLENEDIOXYAMPHETAMINE; 3,4 METHYLENEDIOXYMETHAMPHETAMINE; BENZOYLECGONINE; CODEINE; DIHYDROCODEINE; DRUG METABOLITE; HYDROCODONE; HYDROMORPHONE; METHADONE; METHAMPHETAMINE; METHYLPHENIDATE; MORPHINE; MORPHINE 6 ACETATE; N ETHYL 3,4 METHYLENEDIOXYAMPHETAMINE; OXYCODONE; OXYMORPHONE; PRESCRIPTION DRUG; TRAMADOL; ZOLPIDEM; NARCOTIC AGENT;

EID: 84907788287     PISSN: 03790738     EISSN: 18726283     Source Type: Journal    
DOI: 10.1016/j.forsciint.2014.08.022     Document Type: Article
Times cited : (25)

References (42)
  • 1
    • 85165766911 scopus 로고    scopus 로고
    • DRUID Project. , (accessed 14.04.14)
    • DRUID Project. , 2004 (accessed 14.04.14). http://www.druid-project.eu/.
    • (2004)
  • 4
    • 84897845046 scopus 로고    scopus 로고
    • Pharmacokinetic and pharmacodynamic effects of methylphenidate and MDMA administered alone or in combination
    • Hysek C.M., Simmler L.D., Schillinger N., Meyer N., Schmid Y., Donzelli M., et al. Pharmacokinetic and pharmacodynamic effects of methylphenidate and MDMA administered alone or in combination. Int. J. Neuropsychopharmacol. 2014, 17:371-381.
    • (2014) Int. J. Neuropsychopharmacol. , vol.17 , pp. 371-381
    • Hysek, C.M.1    Simmler, L.D.2    Schillinger, N.3    Meyer, N.4    Schmid, Y.5    Donzelli, M.6
  • 7
    • 57849136862 scopus 로고    scopus 로고
    • Mass spectrometric approaches in impaired driving toxicology
    • (review)
    • Maurer H.H. Mass spectrometric approaches in impaired driving toxicology. Anal. Bioanal. Chem. 2009, 393:97-107. (review).
    • (2009) Anal. Bioanal. Chem. , vol.393 , pp. 97-107
    • Maurer, H.H.1
  • 8
    • 14844312891 scopus 로고    scopus 로고
    • Multi-analyte procedures for screening for and quantification of drugs in blood, plasma, or serum by liquid chromatography-single stage or tandem mass spectrometry (LC-MS or LC-MS/MS) relevant to clinical and forensic toxicology
    • Maurer H.H. Multi-analyte procedures for screening for and quantification of drugs in blood, plasma, or serum by liquid chromatography-single stage or tandem mass spectrometry (LC-MS or LC-MS/MS) relevant to clinical and forensic toxicology. Clin. Biochem. 2005, 38:310-318.
    • (2005) Clin. Biochem. , vol.38 , pp. 310-318
    • Maurer, H.H.1
  • 9
    • 84858449300 scopus 로고    scopus 로고
    • The International Council on Alcohol - Drugs and Traffic Safety Guidelines for Drugged Driving Research 2007, http://international.drugabuse.gov/information/PDFs/TalloiresReport.pdf.
    • (2007) Guidelines for Drugged Driving Research
  • 10
    • 34248191277 scopus 로고    scopus 로고
    • Concentrations of scheduled prescription drugs in blood of impaired drivers: considerations for interpreting the results
    • Jones A.W., Holmgren A., Kugelberg F.C. Concentrations of scheduled prescription drugs in blood of impaired drivers: considerations for interpreting the results. Ther. Drug Monit. 2007, 29:248-260.
    • (2007) Ther. Drug Monit. , vol.29 , pp. 248-260
    • Jones, A.W.1    Holmgren, A.2    Kugelberg, F.C.3
  • 12
    • 57849107769 scopus 로고    scopus 로고
    • Toxicological considerations in impaired driving research and enforcement: sample selection
    • Safety TICoA-DaT (Ed.)
    • Logan B.K. Toxicological considerations in impaired driving research and enforcement: sample selection. Guidelines for Drugged Driving Research 2007, 17-22. http://international.drugabuse.gov/information/PDFs/TalloiresReport.pdf, Safety TICoA-DaT (Ed.).
    • (2007) Guidelines for Drugged Driving Research , pp. 17-22
    • Logan, B.K.1
  • 13
    • 34547380878 scopus 로고    scopus 로고
    • Bioanalytical procedures for determination of drugs of abuse in blood
    • Kraemer T., Paul L. Bioanalytical procedures for determination of drugs of abuse in blood. Anal. Bioanal. Chem. 2007, 388:1415-1435.
    • (2007) Anal. Bioanal. Chem. , vol.388 , pp. 1415-1435
    • Kraemer, T.1    Paul, L.2
  • 14
    • 32544449467 scopus 로고    scopus 로고
    • Fast gas chromatography/mass spectrometric assay for the validated quantitative determination of methadone and the primary metabolite EDDP in whole blood
    • Gunnar T., Eskola T., Lillsunde P. Fast gas chromatography/mass spectrometric assay for the validated quantitative determination of methadone and the primary metabolite EDDP in whole blood. Rapid Commun. Mass Spectrom. 2006, 20:673-679.
    • (2006) Rapid Commun. Mass Spectrom. , vol.20 , pp. 673-679
    • Gunnar, T.1    Eskola, T.2    Lillsunde, P.3
  • 15
    • 74549185750 scopus 로고    scopus 로고
    • High-throughput analysis of amphetamines in blood and urine with online solid-phase extraction-liquid chromatography-tandem mass spectrometry
    • Fernandez M.del.M., Wille S.M., Samyn N., Wood M., Lopez-Rivadulla M., De Boeck G. High-throughput analysis of amphetamines in blood and urine with online solid-phase extraction-liquid chromatography-tandem mass spectrometry. J. Anal. Toxicol. 2009, 33:578-587.
    • (2009) J. Anal. Toxicol. , vol.33 , pp. 578-587
    • Fernandez, M.1    Wille, S.M.2    Samyn, N.3    Wood, M.4    Lopez-Rivadulla, M.5    De Boeck, G.6
  • 16
    • 64249131015 scopus 로고    scopus 로고
    • A validated hybrid quadrupole linear ion-trap LC-MS method for the analysis of morphine and morphine glucuronides applied to opiate deaths
    • Taylor K., Elliott S. A validated hybrid quadrupole linear ion-trap LC-MS method for the analysis of morphine and morphine glucuronides applied to opiate deaths. Forensic Sci. Int. 2009, 187:34-41.
    • (2009) Forensic Sci. Int. , vol.187 , pp. 34-41
    • Taylor, K.1    Elliott, S.2
  • 17
    • 77950348389 scopus 로고    scopus 로고
    • Quantitation of morphine, codeine, hydrocodone, hydromorphone, oxycodone, oxymorphone, and 6-monoacetylmorphine (6-MAM) in urine, blood, serum, or plasma using liquid chromatography with tandem mass spectrometry detection
    • Dahn T., Gunn J., Kriger S., Terrell A.R. Quantitation of morphine, codeine, hydrocodone, hydromorphone, oxycodone, oxymorphone, and 6-monoacetylmorphine (6-MAM) in urine, blood, serum, or plasma using liquid chromatography with tandem mass spectrometry detection. Methods Mol. Biol. 2010, 603:411-422.
    • (2010) Methods Mol. Biol. , vol.603 , pp. 411-422
    • Dahn, T.1    Gunn, J.2    Kriger, S.3    Terrell, A.R.4
  • 19
    • 34447642487 scopus 로고    scopus 로고
    • Simultaneous analysis of six amphetamines and analogues in hair, blood and urine by LC-ESI-MS/MS. Application to the determination of MDMA after low ecstasy intake
    • Cheze M., Deveaux M., Martin C., Lhermitte M., Pepin G. Simultaneous analysis of six amphetamines and analogues in hair, blood and urine by LC-ESI-MS/MS. Application to the determination of MDMA after low ecstasy intake. Forensic Sci. Int. 2007, 170:100-104.
    • (2007) Forensic Sci. Int. , vol.170 , pp. 100-104
    • Cheze, M.1    Deveaux, M.2    Martin, C.3    Lhermitte, M.4    Pepin, G.5
  • 20
    • 34249733725 scopus 로고    scopus 로고
    • Quantitative analysis of cocaine and its metabolites in whole blood and urine by high-performance liquid chromatography coupled with tandem mass spectrometry
    • Johansen S.S., Bhatia H.M. Quantitative analysis of cocaine and its metabolites in whole blood and urine by high-performance liquid chromatography coupled with tandem mass spectrometry. J. Chromatogr. B: Anal. Technol. Biomed. Life Sci. 2007, 852:338-344.
    • (2007) J. Chromatogr. B: Anal. Technol. Biomed. Life Sci. , vol.852 , pp. 338-344
    • Johansen, S.S.1    Bhatia, H.M.2
  • 21
    • 33745792137 scopus 로고    scopus 로고
    • An automated and fully validated LC-MS/MS procedure for the simultaneous determination of 11 opioids used in palliative care, with 5 of their metabolites
    • Musshoff F., Trafkowski J., Kuepper U., Madea B. An automated and fully validated LC-MS/MS procedure for the simultaneous determination of 11 opioids used in palliative care, with 5 of their metabolites. J. Mass Spectrom. 2006, 41:633-640.
    • (2006) J. Mass Spectrom. , vol.41 , pp. 633-640
    • Musshoff, F.1    Trafkowski, J.2    Kuepper, U.3    Madea, B.4
  • 22
    • 84880571557 scopus 로고    scopus 로고
    • Quantitative analysis of 26 opioids, cocaine, and their metabolites in human blood by ultra performance liquid chromatography-tandem mass spectrometry
    • Fernandez M.del.M., Wille S.M., Kummer N., Di Fazio V., Ruyssinckx E., Samyn N. Quantitative analysis of 26 opioids, cocaine, and their metabolites in human blood by ultra performance liquid chromatography-tandem mass spectrometry. Ther. Drug Monit. 2013, 35:510-521.
    • (2013) Ther. Drug Monit. , vol.35 , pp. 510-521
    • Fernandez, M.1    Wille, S.M.2    Kummer, N.3    Di Fazio, V.4    Ruyssinckx, E.5    Samyn, N.6
  • 23
    • 77951257715 scopus 로고    scopus 로고
    • Determination of 19 drugs of abuse and metabolites in whole blood by high-performance liquid chromatography-tandem mass spectrometry
    • Bjork M.K., Nielsen M.K., Markussen L.O., Klinke H.B., Linnet K. Determination of 19 drugs of abuse and metabolites in whole blood by high-performance liquid chromatography-tandem mass spectrometry. Anal. Bioanal. Chem. 2010, 396:2393-2401.
    • (2010) Anal. Bioanal. Chem. , vol.396 , pp. 2393-2401
    • Bjork, M.K.1    Nielsen, M.K.2    Markussen, L.O.3    Klinke, H.B.4    Linnet, K.5
  • 24
    • 84878401945 scopus 로고    scopus 로고
    • Quantification of 31 illicit and medicinal drugs and metabolites in whole blood by fully automated solid-phase extraction and ultra-performance liquid chromatography-tandem mass spectrometry
    • Bjork M.K., Simonsen K.W., Andersen D.W., Dalsgaard P.W., Sigurethardottir S.R., Linnet K., et al. Quantification of 31 illicit and medicinal drugs and metabolites in whole blood by fully automated solid-phase extraction and ultra-performance liquid chromatography-tandem mass spectrometry. Anal. Bioanal. Chem. 2013, 405:2607-2617.
    • (2013) Anal. Bioanal. Chem. , vol.405 , pp. 2607-2617
    • Bjork, M.K.1    Simonsen, K.W.2    Andersen, D.W.3    Dalsgaard, P.W.4    Sigurethardottir, S.R.5    Linnet, K.6
  • 25
    • 78049504396 scopus 로고    scopus 로고
    • A validated method for simultaneous screening and quantification of twenty-three benzodiazepines and metabolites plus zopiclone and zaleplone in whole blood by liquid-liquid extraction and ultra-performance liquid chromatography-tandem mass spectrometry
    • Simonsen K.W., Hermansson S., Steentoft A., Linnet K. A validated method for simultaneous screening and quantification of twenty-three benzodiazepines and metabolites plus zopiclone and zaleplone in whole blood by liquid-liquid extraction and ultra-performance liquid chromatography-tandem mass spectrometry. J. Anal. Toxicol. 2010, 34:332-341.
    • (2010) J. Anal. Toxicol. , vol.34 , pp. 332-341
    • Simonsen, K.W.1    Hermansson, S.2    Steentoft, A.3    Linnet, K.4
  • 26
    • 33750283760 scopus 로고    scopus 로고
    • Quantification of benzodiazepines in whole blood and serum
    • Dussy F.E., Hamberg C., Briellmann T.A. Quantification of benzodiazepines in whole blood and serum. Int. J. Legal Med. 2006, 120:323-330.
    • (2006) Int. J. Legal Med. , vol.120 , pp. 323-330
    • Dussy, F.E.1    Hamberg, C.2    Briellmann, T.A.3
  • 27
    • 0037663202 scopus 로고    scopus 로고
    • Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS
    • Matuszewski B.K., Constanzer M.L., Chavez-Eng C.M. Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS. Anal. Chem. 2003, 75:3019-3030.
    • (2003) Anal. Chem. , vol.75 , pp. 3019-3030
    • Matuszewski, B.K.1    Constanzer, M.L.2    Chavez-Eng, C.M.3
  • 28
    • 77949642365 scopus 로고    scopus 로고
    • Zur Richtlinie der GTFCh zur Qualitätssicherung bei forensisch-toxikologischen Untersuchungen. Anforderungen an die Validierung von Analysenmethoden
    • Peters F.T., Hartung M., Herbold M., Schmitt G., Daldrup T., Musshoff F., Anhang B. zur Richtlinie der GTFCh zur Qualitätssicherung bei forensisch-toxikologischen Untersuchungen. Anforderungen an die Validierung von Analysenmethoden. Toxichem. Krimtech. 2009, 76:185.
    • (2009) Toxichem. Krimtech. , vol.76 , pp. 185
    • Peters, F.T.1    Hartung, M.2    Herbold, M.3    Schmitt, G.4    Daldrup, T.5    Musshoff, F.6    Anhang, B.7
  • 29
    • 0026606194 scopus 로고
    • Analytical methods validation: bioavailability, bioequivalence and pharmacokinetic studies. Conference report
    • Shah V.P., Midha K.K., Dighe S., McGilveray I.J., Skelly J.P., Yacobi A., et al. Analytical methods validation: bioavailability, bioequivalence and pharmacokinetic studies. Conference report. Pharm. Res. 1992, 9:588-592.
    • (1992) Pharm. Res. , vol.9 , pp. 588-592
    • Shah, V.P.1    Midha, K.K.2    Dighe, S.3    McGilveray, I.J.4    Skelly, J.P.5    Yacobi, A.6
  • 31
    • 0032502859 scopus 로고    scopus 로고
    • Requirements for initial assay validation and publication in J. Chromatography B
    • (editorial)
    • Lindner W., Wainer I.W. Requirements for initial assay validation and publication in J. Chromatography B. J. Chromatogr. B 1998, 707:1-2. (editorial).
    • (1998) J. Chromatogr. B , vol.707 , pp. 1-2
    • Lindner, W.1    Wainer, I.W.2
  • 33
    • 0036827348 scopus 로고    scopus 로고
    • Bioanalytical method validation and its implications for forensic and clinical toxicology - a review
    • (review)
    • Peters F.T., Maurer H.H. Bioanalytical method validation and its implications for forensic and clinical toxicology - a review. Accred. Qual. Assur. 2002, 7:441-449. (review).
    • (2002) Accred. Qual. Assur. , vol.7 , pp. 441-449
    • Peters, F.T.1    Maurer, H.H.2
  • 35
    • 0030580105 scopus 로고    scopus 로고
    • Solid-phase extraction and derivatisation methods for beta-blockers in human post mortem whole blood, urine and equine urine
    • Black S.B., Stenhouse A.M., Hansson R.C. Solid-phase extraction and derivatisation methods for beta-blockers in human post mortem whole blood, urine and equine urine. J. Chromatogr. B 1996, 685:67-80.
    • (1996) J. Chromatogr. B , vol.685 , pp. 67-80
    • Black, S.B.1    Stenhouse, A.M.2    Hansson, R.C.3
  • 36
    • 0032555721 scopus 로고    scopus 로고
    • Solid-phase extraction procedures in systematic toxicological analysis
    • (review)
    • Franke J.P., de-Zeeuw R.A. Solid-phase extraction procedures in systematic toxicological analysis. J. Chromatogr. B 1998, 713:51-59. (review).
    • (1998) J. Chromatogr. B , vol.713 , pp. 51-59
    • Franke, J.P.1    de-Zeeuw, R.A.2
  • 37
    • 0013285756 scopus 로고    scopus 로고
    • COMMISSION DECISION of 12 August 2002 implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results
    • Communities E. COMMISSION DECISION of 12 August 2002 implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results. Off. J. Eur. Commun. 2002, L221:8-36.
    • (2002) Off. J. Eur. Commun. , vol.L221 , pp. 8-36
    • Communities, E.1
  • 38
    • 0032986050 scopus 로고    scopus 로고
    • The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds
    • Bonfiglio R., King R.C., Olah T.V., Merkle K. The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds. Rapid Commun. Mass Spectrom.: RCM 1999, 13:1175-1185.
    • (1999) Rapid Commun. Mass Spectrom.: RCM , vol.13 , pp. 1175-1185
    • Bonfiglio, R.1    King, R.C.2    Olah, T.V.3    Merkle, K.4
  • 39
    • 84864139075 scopus 로고    scopus 로고
    • Therapeutic and toxic blood concentrations of nearly 1000 drugs and other xenobiotics
    • Schulz M., Iwersen-Bergmann S., Andresen H., Schmoldt A. Therapeutic and toxic blood concentrations of nearly 1000 drugs and other xenobiotics. Crit. Care 2012, 16:R136.
    • (2012) Crit. Care , vol.16 , pp. R136
    • Schulz, M.1    Iwersen-Bergmann, S.2    Andresen, H.3    Schmoldt, A.4
  • 42
    • 78649392445 scopus 로고    scopus 로고
    • Ion suppression and enhancement effects of co-eluting analytes in multi-analyte approaches: systematic investigation using ultra-high-performance liquid chromatography/mass spectrometry with atmospheric-pressure chemical ionization or electrospray ionization
    • Remane D., Meyer M.R., Wissenbach D.K., Maurer H.H. Ion suppression and enhancement effects of co-eluting analytes in multi-analyte approaches: systematic investigation using ultra-high-performance liquid chromatography/mass spectrometry with atmospheric-pressure chemical ionization or electrospray ionization. Rapid Commun. Mass Spectrom.: RCM 2010, 24:3103-3108.
    • (2010) Rapid Commun. Mass Spectrom.: RCM , vol.24 , pp. 3103-3108
    • Remane, D.1    Meyer, M.R.2    Wissenbach, D.K.3    Maurer, H.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.