메뉴 건너뛰기




Volumn 51, Issue 5, 2014, Pages 528-538

Validation of a new facility at the Metrology Light Source for the calibration of radiation sources in the wavelength range from 116nm to 400nm

Author keywords

primary source standard; radiometry; synchrotron radiation; VUV sources

Indexed keywords

CALIBRATION; ELECTRON RING ACCELERATORS; LIGHT SOURCES; RADIOMETRY; STORAGE RINGS; SYNCHROTRON RADIATION; SYNCHROTRONS; TUNGSTEN; UNITS OF MEASUREMENT;

EID: 84907465026     PISSN: 00261394     EISSN: 16817575     Source Type: Journal    
DOI: 10.1088/0026-1394/51/5/528     Document Type: Article
Times cited : (11)

References (31)
  • 1
    • 0037228592 scopus 로고    scopus 로고
    • Radiometry with synchrotron radiation
    • Ulm G 2003 Radiometry with synchrotron radiation Metrologia 40 S101
    • (2003) Metrologia , vol.40 , Issue.1 , pp. 101
    • Ulm, G.1
  • 3
    • 4444239860 scopus 로고
    • On the classical radiation of accelerated electrons
    • Schwinger J 1949 On the classical radiation of accelerated electrons Phys. Rev. 75 1912
    • (1949) Phys. Rev. , vol.75 , pp. 1912
    • Schwinger, J.1
  • 5
    • 84975565835 scopus 로고
    • Spectral radiance calibrations between 165-300 nm: An interlaboratory comparison
    • Bridges J M, Ott W R, Pitz E, Schultz A, Einfeld D and Stuck D 1977 Spectral radiance calibrations between 165-300 nm: an interlaboratory comparison Appl. Opt. 16 1788-90
    • (1977) Appl. Opt. , vol.16 , pp. 1788-1790
    • Bridges, J.M.1    Ott, W.R.2    Pitz, E.3    Schultz, A.4    Einfeld, D.5    Stuck, D.6
  • 6
    • 84975595328 scopus 로고
    • Electron storage ring BESSY as a radiometric source of calculable spectral radiant power between 0.5 and 1000 nm
    • Riehle F and Wende B 1985 Electron storage ring BESSY as a radiometric source of calculable spectral radiant power between 0.5 and 1000 nm Opt. Lett. 10 365
    • (1985) Opt. Lett. , vol.10 , pp. 365
    • Riehle, F.1    Wende, B.2
  • 7
    • 0000334353 scopus 로고
    • Measuring devices at BESSY for stored beam currents ranging from 0.8 pA to 1 A
    • Ulm G, Hänsel-Ziegler W, Bernstorff S and Wolf F 1989 Measuring devices at BESSY for stored beam currents ranging from 0.8 pA to 1 A Rev. Sci. Instrum. 60 1752
    • (1989) Rev. Sci. Instrum. , vol.60 , pp. 1752
    • Ulm, G.1    Hänsel-Ziegler, W.2    Bernstorff, S.3    Wolf, F.4
  • 8
    • 0000417586 scopus 로고
    • A beam line for radiant power measurements of vacuum ultraviolet and ultraviolet sources in the wavelength range 40-400 nm
    • Hollandt J, Jans W, Kühne M, Lindenlauf F and Wende B 1992 A beam line for radiant power measurements of vacuum ultraviolet and ultraviolet sources in the wavelength range 40-400 nm Rev. Sci. Instrum. 63 1278
    • (1992) Rev. Sci. Instrum. , vol.63 , Issue.1 , pp. 1278
    • Hollandt, J.1    Jans, W.2    Kühne, M.3    Lindenlauf, F.4    Wende, B.5
  • 9
    • 26444565642 scopus 로고
    • Beamline for the characterization of radiation transfer standards ranging from 200 to 2000 eV
    • Thornagel R and Kühne M 1989 Beamline for the characterization of radiation transfer standards ranging from 200 to 2000 eV Rev. Sci. Instrum. 60 1920
    • (1989) Rev. Sci. Instrum. , vol.60 , pp. 1920
    • Thornagel, R.1    Kühne, M.2
  • 10
    • 0030142177 scopus 로고
    • Determination of the spectral radiance of transfer standards in the spectral range 110 nm to 400 nm using BESSY i as a primary source standard
    • Lei F, Paustian W and Tegler E 1995 Determination of the spectral radiance of transfer standards in the spectral range 110 nm to 400 nm using BESSY I as a primary source standard Metrologia 32 589
    • (1995) Metrologia , vol.32 , Issue.6 , pp. 589
    • Lei, F.1    Paustian, W.2    Tegler, E.3
  • 11
    • 0035716749 scopus 로고    scopus 로고
    • The electron storage ring BESSY II as a primary source standard from the visible to the x-ray range
    • Thornagel R, Klein R and Ulm G 2001 The electron storage ring BESSY II as a primary source standard from the visible to the x-ray range Metrologia 38 385
    • (2001) Metrologia , vol.38 , Issue.5 , pp. 385
    • Thornagel, R.1    Klein, R.2    Ulm, G.3
  • 17
    • 0034474543 scopus 로고    scopus 로고
    • SURF III - An improved storage ring for radiometry
    • Arp U, Friedman R, Furst M, Makr S and Shaw P 2000 SURF III - an improved storage ring for radiometry Metrologia 37 357
    • (2000) Metrologia , vol.37 , Issue.5 , pp. 357
    • Arp, U.1    Friedman, R.2    Furst, M.3    Makr, S.4    Shaw, P.5
  • 18
    • 0037229095 scopus 로고    scopus 로고
    • Improvement of the beamline for calibration of the transfer standard in the UV and VUV regions
    • Zama T and Saito I 2003 Improvement of the beamline for calibration of the transfer standard in the UV and VUV regions Metrologia 40 S115
    • (2003) Metrologia , vol.40 , Issue.1 , pp. 115
    • Zama, T.1    Saito, I.2
  • 21
    • 0001013151 scopus 로고
    • Hollow cathode transfer standards for the radiometric calibration of VUV telescopes of the Solar and Heliospheric Observatory (SOHO)
    • Hollandt J, Huber M and Kühne M 1993 Hollow cathode transfer standards for the radiometric calibration of VUV telescopes of the Solar and Heliospheric Observatory (SOHO) Metrologia 30 381
    • (1993) Metrologia , vol.30 , Issue.4 , pp. 381
    • Hollandt, J.1    Huber, M.2    Kühne, M.3
  • 22
    • 0000989762 scopus 로고    scopus 로고
    • Radiometric calibration of SUMER: Refinement of the laboratory results under operational conditions on SOHO
    • Wilhelm K et al 1997 Radiometric calibration of SUMER: refinement of the laboratory results under operational conditions on SOHO Appl. Opt. 36 6416
    • (1997) Appl. Opt. , vol.36 , pp. 6416
    • Wilhelm, K.1
  • 23
  • 24
    • 77749345695 scopus 로고    scopus 로고
    • Absolute radiometric calibration of the EUNIS-06 170-205A and calibration update for the coronal diagnostic spectrometer/normal-incidence spectrometer
    • Wang T, Brosius J W, Thomas R J, Rabin D M and Davila J M 2010 Absolute radiometric calibration of the EUNIS-06 170-205A and calibration update for the coronal diagnostic spectrometer/normal-incidence spectrometer Astrophys. J. Suppl. Ser. 186 222-32
    • (2010) Astrophys. J. Suppl. Ser. , vol.186 , Issue.2 , pp. 222-232
    • Wang, T.1    Brosius, J.W.2    Thomas, R.J.3    Rabin, D.M.4    Davila, J.M.5
  • 25
    • 84887011863 scopus 로고    scopus 로고
    • SPICE EUV spectrometer for the Solar Orbiter mission
    • Fludra A et al 2013 SPICE EUV spectrometer for the Solar Orbiter mission Proc. SPIE 8862 88620F Solar Physics and Space Weather Instrumentation V
    • (2013) Proc. SPIE , vol.8862
    • Fludra, A.1
  • 26
    • 84907474882 scopus 로고    scopus 로고
    • 1989 Agreement between the National Physics Laboratory (NPL) and the PTB on UV and VUV radiometric scales and calibration services Euromet 88/36
    • - 1989 Agreement between the National Physics Laboratory (NPL) and the PTB on UV and VUV radiometric scales and calibration services Euromet 88/36
  • 27
    • 84907474881 scopus 로고    scopus 로고
    • 1999 Agreement between the Bureau National Metrologie (BNM) and the PTB on tracability of source based UV and VUV radiometric scales and calibration services Euromet 539
    • - 1999 Agreement between the Bureau National Metrologie (BNM) and the PTB on tracability of source based UV and VUV radiometric scales and calibration services Euromet 539
  • 28
    • 0033702356 scopus 로고    scopus 로고
    • A CCPR international comparison of spectral radiance measurements in the air-ultraviolet
    • Lambe R P, Saunders R, Gibson C, Hollandt J and Tegeler E 2000 A CCPR international comparison of spectral radiance measurements in the air-ultraviolet Metrologia 37 51
    • (2000) Metrologia , vol.37 , Issue.1 , pp. 51
    • Lambe, R.P.1    Saunders, R.2    Gibson, C.3    Hollandt, J.4    Tegeler, E.5
  • 29
    • 84907474880 scopus 로고    scopus 로고
    • 1997 Report of the Working Group on Air-Ultraviolet Spectral Radiometry of the Comité Consultatif de Photométrie et Radiométrie (CCPR), Part II, Results of an Intercomparison of UV Source Measurement Scales
    • - 1997 Report of the Working Group on Air-Ultraviolet Spectral Radiometry of the Comité Consultatif de Photométrie et Radiométrie (CCPR), Part II, Results of an Intercomparison of UV Source Measurement Scales
  • 30
    • 80053156514 scopus 로고    scopus 로고
    • Synchrotron radiation-based bilateral intercomparison of ultraviolet source calibrations
    • Arp U, Klein R, Li Z, Paustian W, Richter M, Shaw P-S and Thornagel R 2011 Synchrotron radiation-based bilateral intercomparison of ultraviolet source calibrations Metrologia 48 261
    • (2011) Metrologia , vol.48 , Issue.5 , pp. 261
    • Arp, U.1    Klein, R.2    Li, Z.3    Paustian, W.4    Richter, M.5    Shaw, P.-S.6    Thornagel, R.7
  • 31
    • 67650904524 scopus 로고    scopus 로고
    • Radiometric comparison of the primary synchrotron radiation source standard Metrology Light Source with calibrated filter radiometers in the visible and NIR spectral range
    • Klein R, Taubert D, Thornagel R, Hollandt J and Ulm G 2009 Radiometric comparison of the primary synchrotron radiation source standard Metrology Light Source with calibrated filter radiometers in the visible and NIR spectral range Metrologia 46 359
    • (2009) Metrologia , vol.46 , Issue.3 , pp. 359
    • Klein, R.1    Taubert, D.2    Thornagel, R.3    Hollandt, J.4    Ulm, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.