메뉴 건너뛰기




Volumn 9, Issue 9, 2014, Pages

Improved cerebral time-of-flight magnetic resonance angiography at 7 Tesla - Feasibility study and preliminary results using optimized venous saturation pulses

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFACT; BLOOD GAS PARAMETERS; BRAIN ANGIOGRAPHY; BRAIN ARTERIOVENOUS MALFORMATION; BRAIN ARTERY ANEURYSM; BRAIN CIRCULUS ARTERIOSUS; CLINICAL ARTICLE; CONTRAST ENHANCEMENT; CRANIAL SINUS; DURAL ARTERIOVENOUS FISTULA; FEASIBILITY STUDY; FEMALE; GRAY MATTER; HEAD COIL; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; LOW FLIP ANGLE; MAGNETIC RESONANCE ANGIOGRAPHY; MALE; MIDDLE CEREBRAL ARTERY; MOYAMOYA DISEASE; NEURORADIOLOGIST; NEUROSURGERY; PROCESS OPTIMIZATION; PROSPECTIVE STUDY; RADIATION EQUIPMENT; RADIOLOGICAL PARAMETERS; SURGICAL PATIENT; TIME OF FLIGHT MAGNETIC RESONANCE ANGIOGRAPHY; VARIABLE RATE SELECTIVE EXCITATION ALGORITHM; VENOUS SATURATION PULSE; WHOLE BODY SCANNER; BRAIN; CEREBROVASCULAR DISEASE; COMPUTER ASSISTED DIAGNOSIS; IMAGE ENHANCEMENT; INTRACRANIAL ANEURYSM; MIDDLE AGED; PROCEDURES; RADIOGRAPHY; VASCULARIZATION;

EID: 84907222776     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0106697     Document Type: Article
Times cited : (25)

References (38)
  • 1
    • 0024325998 scopus 로고
    • MR angiography with two-dimensional acquisition and three-dimensional display. Work in progress
    • Keller PJ, Drayer BP, Fram EK, Williams KD, Dumoulin CL, et al. (1989) MR angiography with two-dimensional acquisition and three-dimensional display. Work in progress. Radiology 173: 527-532.
    • (1989) Radiology , vol.173 , pp. 527-532
    • Keller, P.J.1    Drayer, B.P.2    Fram, E.K.3    Williams, K.D.4    Dumoulin, C.L.5
  • 5
    • 0033366633 scopus 로고    scopus 로고
    • Evaluation of cerebral aneurysms with high-resolution MR angiography using a section-interpolation technique: Correlation with digital subtraction angiography
    • Chung TS, Joo JY, Lee SK, Chien D, Laub G (1999) Evaluation of cerebral aneurysms with high-resolution MR angiography using a section-interpolation technique: correlation with digital subtraction angiography. Am J Neuroradiol 20: 229-235.
    • (1999) Am J Neuroradiol , vol.20 , pp. 229-235
    • Chung, T.S.1    Joo, J.Y.2    Lee, S.K.3    Chien, D.4    Laub, G.5
  • 6
    • 29544443426 scopus 로고    scopus 로고
    • MR angiography at 3 T versus digital subtraction angiography in the follow-up of intracranial aneurysms treated with detachable coils
    • Majoie CBLM, Sprengers ME, Van Rooij WJJ, Lavini C, Sluzewski M, et al. (2005) MR angiography at 3 T versus digital subtraction angiography in the follow-up of intracranial aneurysms treated with detachable coils. American Journal of Neuroradiology 26: 1349-1356.
    • (2005) American Journal of Neuroradiology , vol.26 , pp. 1349-1356
    • Majoie, C.B.L.M.1    Sprengers, M.E.2    Van Rooij, W.J.J.3    Lavini, C.4    Sluzewski, M.5
  • 7
    • 33746922319 scopus 로고    scopus 로고
    • Modern cross-sectional imaging in the diagnosis and follow-up of intracranial aneurysms
    • Papke K, Brassel F (2006) Modern cross-sectional imaging in the diagnosis and follow-up of intracranial aneurysms. Eur Radiol 16: 2051-2066.
    • (2006) Eur Radiol , vol.16 , pp. 2051-2066
    • Papke, K.1    Brassel, F.2
  • 8
    • 55149102597 scopus 로고    scopus 로고
    • Noninvasive depiction of the lenticulostriate arteries with time-of-flight MR angiography at 7.0 T
    • Hendrikse J, Zwanenburg JJ, Visser F, Takahara T, Luijten P (2008) Noninvasive Depiction of the Lenticulostriate Arteries with Time-of-Flight MR Angiography at 7.0 T. Cerebrovascular diseases 26: 624-629.
    • (2008) Cerebrovascular Diseases , vol.26 , pp. 624-629
    • Hendrikse, J.1    Zwanenburg, J.J.2    Visser, F.3    Takahara, T.4    Luijten, P.5
  • 10
    • 0345015505 scopus 로고    scopus 로고
    • Time-of-flight MR angiography: Comparison of 3.0-T imaging and 1.5-T imaging-initial experience
    • Willinek WA, Born M, Simon B, Tschampa HJ, Krautmacher C, et al. (2003) Time-of-Flight MR Angiography: Comparison of 3.0-T Imaging and 1.5-T Imaging-Initial Experience. Radiology 229: 913-920.
    • (2003) Radiology , vol.229 , pp. 913-920
    • Willinek, W.A.1    Born, M.2    Simon, B.3    Tschampa, H.J.4    Krautmacher, C.5
  • 11
    • 2442681584 scopus 로고    scopus 로고
    • Comparison of intracranial 3D-ToF-MRA with and without parallel acquisition techniques at 1.5 T and 3.0 T: Preliminary results
    • Gaa J, Weidauer S, Requardt M, Kiefer B, Lanfermann H, et al. (2004) Comparison of intracranial 3D-ToF-MRA with and without parallel acquisition techniques at 1.5 T and 3.0 T: Preliminary results. Acta radiologica 45: 327-332.
    • (2004) Acta Radiologica , vol.45 , pp. 327-332
    • Gaa, J.1    Weidauer, S.2    Requardt, M.3    Kiefer, B.4    Lanfermann, H.5
  • 12
    • 84872595423 scopus 로고    scopus 로고
    • Comparison of magnetic resonance angiography scans on 1.5, 3, and 7 tesla units: A quantitative study of 3-dimensional cerebrovasculature
    • Nowinski WL, Puspitasaari F, Volkau I, Marchenko Y, Knopp MV (2013) Comparison of Magnetic Resonance Angiography Scans on 1.5, 3, and 7 Tesla Units: A Quantitative Study of 3-Dimensional Cerebrovasculature. J Neuroimaging: 86-95.
    • (2013) J Neuroimaging , pp. 86-95
    • Nowinski, W.L.1    Puspitasaari, F.2    Volkau, I.3    Marchenko, Y.4    Knopp, M.V.5
  • 13
    • 12744261213 scopus 로고    scopus 로고
    • 3.0-Tesla MR angiography of intracranial aneurysms: Comparison of time-of-flight and contrast-enhanced techniques
    • Gibbs GF, Huston J 3rd, Bernstein MA, Riederer SJ, Brown RD Jr (2005) 3.0-Tesla MR angiography of intracranial aneurysms: comparison of time-of-flight and contrast-enhanced techniques. J Magn Reson Imaging 21: 97-102.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 97-102
    • Gibbs, G.F.1    Huston, J.2    Bernstein, M.A.3    Riederer, S.J.4    Brown, R.D.5
  • 14
    • 44449119540 scopus 로고    scopus 로고
    • Observation of the lenticulostriate arteries in the human brain in vivo using 7.0 T MR angiography
    • Cho ZH, Kang CK, Han JY, Kim SH, Kim KN, et al. (2008) Observation of the lenticulostriate arteries in the human brain in vivo using 7.0 T MR angiography. Stroke 39: 1604-1606.
    • (2008) Stroke , vol.39 , pp. 1604-1606
    • Cho, Z.H.1    Kang, C.K.2    Han, J.Y.3    Kim, S.H.4    Kim, K.N.5
  • 16
    • 60349132365 scopus 로고    scopus 로고
    • Imaging and analysis of lenticulostriate arteries using 7.0-Tesla magnetic resonance angiography
    • Kang CK, Park CW, Han JY, Kim SH, Park CA, et al. (2009) Imaging and analysis of lenticulostriate arteries using 7.0-Tesla magnetic resonance angiography. Magn Reson Med 61: 136-144.
    • (2009) Magn Reson Med , vol.61 , pp. 136-144
    • Kang, C.K.1    Park, C.W.2    Han, J.Y.3    Kim, S.H.4    Park, C.A.5
  • 18
    • 57049120174 scopus 로고    scopus 로고
    • MR angiography of the cerebral perforating arteries with magnetization prepared anatomical reference at 7 T: Comparison with time-of-flight
    • Zwanenburg JJ, Hendrikse J, Takahara T, Visser F, Luijten PR (2008) MR angiography of the cerebral perforating arteries with magnetization prepared anatomical reference at 7 T: comparison with time-of-flight. J Magn Reson Imaging 28: 1519-1526.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 1519-1526
    • Zwanenburg, J.J.1    Hendrikse, J.2    Takahara, T.3    Visser, F.4    Luijten, P.R.5
  • 19
    • 34447341182 scopus 로고    scopus 로고
    • High-field-strength magnetic resonance: Potential and limits
    • Ladd ME (2007) High-field-strength magnetic resonance: potential and limits. Top Magn Reson Imaging 18: 139-152.
    • (2007) Top Magn Reson Imaging , vol.18 , pp. 139-152
    • Ladd, M.E.1
  • 21
    • 64649090409 scopus 로고    scopus 로고
    • First clinical study on ultra-high-field MR imaging in patients with multiple sclerosis: Comparison of 1.5 T and 7 T
    • Kollia K, Maderwald S, Putzki N, Schlamann M, Theysohn JM, et al. (2009) First clinical study on ultra-high-field MR imaging in patients with multiple sclerosis: comparison of 1.5 T and 7 T. Am J Neuroradiol 30: 699-702.
    • (2009) Am J Neuroradiol , vol.30 , pp. 699-702
    • Kollia, K.1    Maderwald, S.2    Putzki, N.3    Schlamann, M.4    Theysohn, J.M.5
  • 22
    • 84896923307 scopus 로고    scopus 로고
    • Non-enhanced MR imaging of cerebral aneurysms: 7 Tesla versus 1.5 Tesla
    • Wrede KH, Dammann P, Mönninghoff C, Johst S, Maderwald S, et al. (2014) Non-Enhanced MR Imaging of Cerebral Aneurysms: 7 Tesla versus 1.5 Tesla. PLoS ONE 9: e84562.
    • (2014) PLoS ONE , vol.9 , pp. e84562
    • Wrede, K.H.1    Dammann, P.2    Mönninghoff, C.3    Johst, S.4    Maderwald, S.5
  • 23
    • 0023197057 scopus 로고
    • Spatial presaturation: A method for suppressing flow artifacts and improving depiction of vascular anatomy in MR imaging
    • Felmlee JP, Ehman RL (1987) Spatial presaturation: A method for suppressing flow artifacts and improving depiction of vascular anatomy in MR imaging. Radiology 164: 559-564.
    • (1987) Radiology , vol.164 , pp. 559-564
    • Felmlee, J.P.1    Ehman, R.L.2
  • 24
    • 84907220115 scopus 로고    scopus 로고
    • Spatial saturation pulses
    • Bernstein MA, King KF, Zhou ZJ, editors. Amsterdam; Boston: Academic Press
    • King KF (2004) Spatial Saturation Pulses. In: Bernstein MA, King KF, Zhou ZJ, editors. Handbook of MRI pulse sequences. Amsterdam; Boston: Academic Press. 148-152.
    • (2004) Handbook of MRI Pulse Sequences , pp. 148-152
    • King, K.F.1
  • 25
    • 0027691456 scopus 로고
    • Pulse sequence strategies for vascular contrast in time-of-flight carotid MR angiography
    • Tkach JA, Ruggieri PM, Ross JS, Modic MT, Dillinger JJ, et al. (1993) Pulse sequence strategies for vascular contrast in time-of-flight carotid MR angiography. J Magn Reson Imaging 3: 811-820.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 811-820
    • Tkach, J.A.1    Ruggieri, P.M.2    Ross, J.S.3    Modic, M.T.4    Dillinger, J.J.5
  • 27
    • 84863686088 scopus 로고    scopus 로고
    • Time-of-flight magnetic resonance angiography at 7 T using venous saturation pulses with reduced flip angles
    • Johst S, Wrede KH, Ladd ME, Maderwald S (2012) Time-of-Flight Magnetic Resonance Angiography at 7 T Using Venous Saturation Pulses With Reduced Flip Angles. Invest Radiol 47: 445-450.
    • (2012) Invest Radiol , vol.47 , pp. 445-450
    • Johst, S.1    Wrede, K.H.2    Ladd, M.E.3    Maderwald, S.4
  • 29
    • 84862262302 scopus 로고    scopus 로고
    • Contrast enhancement in TOF cerebral angiography at 7 T using saturation and MT pulses under SAR constraints: Impact of VERSE and sparse pulses
    • Schmitter S, Bock M, Johst S, Auerbach EJ, Ugurbil K, et al. (2012) Contrast enhancement in TOF cerebral angiography at 7 T using saturation and MT pulses under SAR constraints: impact of VERSE and sparse pulses. Magn Reson Med 68: 188-197.
    • (2012) Magn Reson Med , vol.68 , pp. 188-197
    • Schmitter, S.1    Bock, M.2    Johst, S.3    Auerbach, E.J.4    Ugurbil, K.5
  • 31
    • 0022465686 scopus 로고
    • A proposed grading system for arteriovenous malformations
    • Spetzler RF, Martin NA (1986) A proposed grading system for arteriovenous malformations. J Neurosurg 65: 476-483.
    • (1986) J Neurosurg , vol.65 , pp. 476-483
    • Spetzler, R.F.1    Martin, N.A.2
  • 32
    • 0028938704 scopus 로고
    • Cerebral dural arteriovenous fistulas: Clinical and angiographic correlation with a revised classification of venous drainage
    • Cognard C, Gobin YP, Pierot L, Bailly AL, Houdart E, et al. (1995) Cerebral dural arteriovenous fistulas: clinical and angiographic correlation with a revised classification of venous drainage. Radiology 194: 671-680.
    • (1995) Radiology , vol.194 , pp. 671-680
    • Cognard, C.1    Gobin, Y.P.2    Pierot, L.3    Bailly, A.L.4    Houdart, E.5
  • 33
    • 71449111937 scopus 로고    scopus 로고
    • Perforating arteries originating from the posterior communicating artery: A 7.0-Tesla MRI study
    • Conijn MM, Hendrikse J, Zwanenburg JJ, Takahara T, Geerlings MI, et al. (2009) Perforating arteries originating from the posterior communicating artery: a 7.0-Tesla MRI study. Eur Radiol 19: 2986-2992.
    • (2009) Eur Radiol , vol.19 , pp. 2986-2992
    • Conijn, M.M.1    Hendrikse, J.2    Zwanenburg, J.J.3    Takahara, T.4    Geerlings, M.I.5
  • 34
    • 49049102296 scopus 로고    scopus 로고
    • Evaluation of MR angiography at 7.0 Tesla MRI using birdcage radio frequency coils with end caps
    • Kang CK, Hong SM, Han JY, Kim KN, Kim SH, et al. (2008) Evaluation of MR angiography at 7.0 Tesla MRI using birdcage radio frequency coils with end caps. Magn Reson Med 60: 330-338.
    • (2008) Magn Reson Med , vol.60 , pp. 330-338
    • Kang, C.K.1    Hong, S.M.2    Han, J.Y.3    Kim, K.N.4    Kim, S.H.5
  • 35
    • 84898487028 scopus 로고    scopus 로고
    • Sequence comparison for non-enhanced MRA of the lower extremity arteries at 7 Tesla
    • Johst S, Orzada S, Fischer A, Schafer LC, Nassenstein K, et al. (2014) Sequence Comparison for Non-Enhanced MRA of the Lower Extremity Arteries at 7 Tesla. PLoS One 9: e86274.
    • (2014) PLoS One , vol.9 , pp. e86274
    • Johst, S.1    Orzada, S.2    Fischer, A.3    Schafer, L.C.4    Nassenstein, K.5
  • 36
    • 84876193481 scopus 로고    scopus 로고
    • MR safety assessment of potential RF heating from cranial fixation plates at 7 T
    • Kraff O, Wrede KH, Schoemberg T, Dammann P, Noureddine Y, et al. (2013) MR safety assessment of potential RF heating from cranial fixation plates at 7 T. Med Phys 40: 042302.
    • (2013) Med Phys , vol.40 , pp. 042302
    • Kraff, O.1    Wrede, K.H.2    Schoemberg, T.3    Dammann, P.4    Noureddine, Y.5
  • 38
    • 84907226175 scopus 로고    scopus 로고
    • In silico and in vitro investigation of temperature elevation close to an aneurysm clip at 7t
    • 20-26 April 2013, Salt Lake City, USA
    • Noureddine Y, Kraff O, Ladd ME, Schaefers G, Wrede KH, et al. (2013) In Silico and in Vitro Investigation of Temperature Elevation Close to an Aneurysm Clip at 7T. In: ISMRM 21st Annual Meeting & Exhibition 20-26 April 2013, Salt Lake City, USA. pp. 4416.
    • (2013) ISMRM 21st Annual Meeting & Exhibition , pp. 4416
    • Noureddine, Y.1    Kraff, O.2    Ladd, M.E.3    Schaefers, G.4    Wrede, K.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.