메뉴 건너뛰기




Volumn 19, Issue 12, 2009, Pages 2986-2992

Perforating arteries originating from the posterior communicating artery: A 7.0-Tesla MRI study

Author keywords

Circle of Willis; Lacunar infarction; Magnetic resonance angiography; Perforating arteries; Posterior communicating artery

Indexed keywords

CONTRAST MEDIUM;

EID: 71449111937     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-009-1485-4     Document Type: Article
Times cited : (42)

References (14)
  • 2
    • 55549116658 scopus 로고    scopus 로고
    • Posterior communicating artery hypoplasia as a risk factor for acute ischemic stroke in the absence of carotid artery occlusion
    • 10.1016/j.jocn.2008.02.002 18945618
    • YM Chuang CY Liu PJ Pan CP Lin 2008 Posterior communicating artery hypoplasia as a risk factor for acute ischemic stroke in the absence of carotid artery occlusion J Clin Neurosci 15 1376 1381 10.1016/j.jocn.2008.02.002 18945618
    • (2008) J Clin Neurosci , vol.15 , pp. 1376-1381
    • Chuang, Y.M.1    Liu, C.Y.2    Pan, P.J.3    Lin, C.P.4
  • 3
    • 0347356520 scopus 로고    scopus 로고
    • Direction of Flow in Posterior Communicating Artery on Magnetic Resonance Angiography in Patients with Occipital Lobe Infarcts
    • DOI 10.1161/01.STR.0000106772.87186.C7
    • JC Jongen CL Franke LM Ramos JT Wilmink J van Gijn 2004 Direction of flow in posterior communicating artery on magnetic resonance angiography in patients with occipital lobe infarcts Stroke 35 104 108 10.1161/01.STR.0000106772.87186. C7 14671241 (Pubitemid 38057600)
    • (2004) Stroke , vol.35 , Issue.1 , pp. 104-108
    • Jongen, J.C.F.1    Franke, C.L.2    Ramos, L.M.P.3    Wilmink, J.T.4    Van Gijn, J.5
  • 4
  • 5
    • 21144436867 scopus 로고    scopus 로고
    • A fetal circle of Willis is associated with a decreased deep white matter lesion load
    • 1:STN:280:DC%2BD2MzjsFSksg%3D%3D 15985606
    • K Ikeda H Kashihara KI Hosozawa, et al. 2005 A fetal circle of Willis is associated with a decreased deep white matter lesion load Neurology 64 2163 2164 1:STN:280:DC%2BD2MzjsFSksg%3D%3D 15985606
    • (2005) Neurology , vol.64 , pp. 2163-2164
    • Ikeda, K.1    Kashihara, H.2    Hosozawa, K.I.3
  • 6
    • 0014422476 scopus 로고
    • The arterial lesions underlying lacunes
    • 10.1007/BF00685305 1:STN:280:DyaF1M7gsFGntw%3D%3D 5708546
    • CM Fisher 1968 The arterial lesions underlying lacunes Acta Neuropathol 12 1 15 10.1007/BF00685305 1:STN:280:DyaF1M7gsFGntw%3D%3D 5708546
    • (1968) Acta Neuropathol , vol.12 , pp. 1-15
    • Fisher, C.M.1
  • 7
    • 0034910017 scopus 로고    scopus 로고
    • Imaging appearance of the symptomatic perforating artery in patients with lacunar infarction: Occlusion or other vascular pathology?
    • DOI 10.1002/ana.1082
    • JM Wardlaw MS Dennis CP Warlow PA Sandercock 2001 Imaging appearance of the symptomatic perforating artery in patients with lacunar infarction: occlusion or other vascular pathology? Ann Neurol 50 208 215 10.1002/ana.1082 1:STN:280:DC%2BD3MvmtFOjsQ%3D%3D 11506404 (Pubitemid 32738146)
    • (2001) Annals of Neurology , vol.50 , Issue.2 , pp. 208-215
    • Wardlaw, J.M.1    Dennis, M.S.2    Warlow, C.P.3    Sandercock, P.A.4
  • 8
    • 0035111194 scopus 로고    scopus 로고
    • Intracranial aneurysms: Clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment
    • 1:STN:280:DC%2BD3M3gs1CjtA%3D%3D 11230659
    • R Anxionnat S Bracard X Ducrocq, et al. 2001 Intracranial aneurysms: clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment Radiology 218 799 808 1:STN:280: DC%2BD3M3gs1CjtA%3D%3D 11230659
    • (2001) Radiology , vol.218 , pp. 799-808
    • Anxionnat, R.1    Bracard, S.2    Ducrocq, X.3
  • 9
    • 0344392008 scopus 로고    scopus 로고
    • A novel image fusion visualizes the angioarchitecture of the perforating arteries in the brain
    • 14625225
    • S Shimizu H Suzuki H Maki, et al. 2003 A novel image fusion visualizes the angioarchitecture of the perforating arteries in the brain AJNR Am J Neuroradiol 24 2011 2014 14625225
    • (2003) AJNR Am J Neuroradiol , vol.24 , pp. 2011-2014
    • Shimizu, S.1    Suzuki, H.2    Maki, H.3
  • 10
    • 30444457908 scopus 로고    scopus 로고
    • Evaluation of the lenticulostriate arteries with rotational angiography and 3D reconstruction
    • 15709128
    • HS Kang MH Han BJ Kwon OK Kwon SH Kim KH Chang 2005 Evaluation of the lenticulostriate arteries with rotational angiography and 3D reconstruction AJNR Am J Neuroradiol 26 306 312 15709128
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 306-312
    • Kang, H.S.1    Han, M.H.2    Kwon, B.J.3    Kwon, O.K.4    Kim, S.H.5    Chang, K.H.6
  • 11
    • 57049120174 scopus 로고    scopus 로고
    • MR angiography of the cerebral perforating arteries with magnetization prepared anatomical reference at 7T: Comparison with time-of-flight
    • 10.1002/jmri.21591 19025959
    • JJ Zwanenburg J Hendrikse T Takahara F Visser PR Luijten 2008 MR angiography of the cerebral perforating arteries with magnetization prepared anatomical reference at 7T: comparison with time-of-flight J Magn Reson Imaging 28 1519 1526 10.1002/jmri.21591 19025959
    • (2008) J Magn Reson Imaging , vol.28 , pp. 1519-1526
    • Zwanenburg, J.J.1    Hendrikse, J.2    Takahara, T.3    Visser, F.4    Luijten, P.R.5
  • 12
    • 0031982341 scopus 로고    scopus 로고
    • Circle of Willis: Morphologic variation on three-dimensional time-of-flight MR angiograms
    • 1:STN:280:DyaK1c7ptFersw%3D%3D 9530305
    • MJ Krabbe-Hartkamp J van der Grond FE de Leeuw, et al. 1998 Circle of Willis: morphologic variation on three-dimensional time-of-flight MR angiograms Radiology 207 103 111 1:STN:280:DyaK1c7ptFersw%3D%3D 9530305
    • (1998) Radiology , vol.207 , pp. 103-111
    • Krabbe-Hartkamp, M.J.1    Van Der Grond, J.2    De Leeuw, F.E.3
  • 14
    • 0031784731 scopus 로고    scopus 로고
    • Limits to the accuracy of vessel diameter measurement in MR angiography
    • 10.1002/jmri.1880080608 1:STN:280:DyaK1M%2FmtlCkuw%3D%3D 9848733
    • RM Hoogeveen CJ Bakker MA Viergever 1998 Limits to the accuracy of vessel diameter measurement in MR angiography J Magn Reson Imaging 8 1228 1235 10.1002/jmri.1880080608 1:STN:280:DyaK1M%2FmtlCkuw%3D%3D 9848733
    • (1998) J Magn Reson Imaging , vol.8 , pp. 1228-1235
    • Hoogeveen, R.M.1    Bakker, C.J.2    Viergever, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.