메뉴 건너뛰기




Volumn 8, Issue SEP, 2014, Pages

Estimating the apparent transverse relaxation time (R2*) from images with different contrasts (ESTATICS) reduces motion artifacts

Author keywords

Apparent transverse relaxation; Artifacts; Motion; Multiple contrasts; Quantitative imaging; Robust fit; T2*; Transverse relaxation

Indexed keywords

ADULT; ARTICLE; ARTIFACT; ARTIFACT REDUCTION; CONTRAST; FEMALE; HEAD MOVEMENT; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; MALE; NEUROIMAGING; NORMAL HUMAN; RELAXATION TIME; WHOLE BODY MRI; WHOLE BODY SCANNER;

EID: 84907202831     PISSN: 16624548     EISSN: 1662453X     Source Type: Journal    
DOI: 10.3389/fnins.2014.00278     Document Type: Article
Times cited : (71)

References (42)
  • 1
    • 20444501009 scopus 로고    scopus 로고
    • Unified segmentation
    • Ashburner, J., and Friston, K. J. (2005). Unified segmentation. Neuroimage 26, 839-851. doi: 10.1016/j.neuroimage.2005.02.018
    • (2005) Neuroimage , vol.26 , pp. 839-851
    • Ashburner, J.1    Friston, K.J.2
  • 4
    • 84899898647 scopus 로고    scopus 로고
    • Widespread age-related differences in the human brain microstructure revealed by quantitative magnetic resonance imaging
    • Callaghan, M. F., Freund, P., Draganski, B., Anderson, E., Cappelletti, M., Chowdhury, R., et al. (2014a). Widespread age-related differences in the human brain microstructure revealed by quantitative magnetic resonance imaging. Neurobiol. Aging 35, 1862-1872. doi: 10.1016/j.neurobiolaging.2014.02.008
    • (2014) Neurobiol. Aging , vol.35 , pp. 1862-1872
    • Callaghan, M.F.1    Freund, P.2    Draganski, B.3    Anderson, E.4    Cappelletti, M.5    Chowdhury, R.6
  • 5
    • 84923130162 scopus 로고    scopus 로고
    • A general linear relaxometry model of R1 using imaging data
    • [Epub ahead of print]
    • Callaghan, M. F., Helms, G., Lutti, A., Mohammadi, S., and Weiskopf, N. (2014b). A general linear relaxometry model of R1 using imaging data. Magn. Reson. Med. doi: 10.1002/mrm.25210. [Epub ahead of print].
    • (2014) Magn. Reson. Med.
    • Callaghan, M.F.1    Helms, G.2    Lutti, A.3    Mohammadi, S.4    Weiskopf, N.5
  • 6
    • 84869015515 scopus 로고    scopus 로고
    • In vivo functional and myeloarchitectonic mapping of human primary auditory areas
    • Dick, F., Tierney, A., Lutti, A., Josephs, O., Sereno, M. I., and Weiskopf, N. (2012). In vivo functional and myeloarchitectonic mapping of human primary auditory areas. J. Neurosci. 32, 16095-16105. doi: 10.1523/JNEUROSCI.1712-12.2012
    • (2012) J. Neurosci. , vol.32 , pp. 16095-16105
    • Dick, F.1    Tierney, A.2    Lutti, A.3    Josephs, O.4    Sereno, M.I.5    Weiskopf, N.6
  • 7
    • 79952705538 scopus 로고    scopus 로고
    • Regional specificity of MRI contrast parameter changes in normal ageing revealed by voxel-based quantification (VBQ)
    • Draganski, B., Ashburner, J., Hutton, C., Kherif, F., Frackowiak, R. S. J., Helms, G., et al. (2011). Regional specificity of MRI contrast parameter changes in normal ageing revealed by voxel-based quantification (VBQ). Neuroimage 55, 1423-1434. doi: 10.1016/j.neuroimage.2011.01.052
    • (2011) Neuroimage , vol.55 , pp. 1423-1434
    • Draganski, B.1    Ashburner, J.2    Hutton, C.3    Kherif, F.4    Frackowiak, R.S.J.5    Helms, G.6
  • 8
    • 84881552399 scopus 로고    scopus 로고
    • MRI investigation of the sensorimotor cortex and the corticospinal tract after acute spinal cord injury: a prospective longitudinal study
    • Freund, P., Weiskopf, N., Ashburner, J., Wolf, K., Sutter, R., Altmann, D. R., et al. (2013). MRI investigation of the sensorimotor cortex and the corticospinal tract after acute spinal cord injury: a prospective longitudinal study. Lancet Neurol. 12, 873-881. doi: 10.1016/S1474-4422(13)70146-7
    • (2013) Lancet Neurol , vol.12 , pp. 873-881
    • Freund, P.1    Weiskopf, N.2    Ashburner, J.3    Wolf, K.4    Sutter, R.5    Altmann, D.R.6
  • 11
    • 40449133227 scopus 로고    scopus 로고
    • Quantitative FLASH MRI at 3T using a rational approximation of the Ernst equation
    • Helms, G., Dathe, H., and Dechent, P. (2008a). Quantitative FLASH MRI at 3T using a rational approximation of the Ernst equation. Magn. Reson. Med. 59, 667-672. doi: 10.1002/mrm.21542
    • (2008) Magn. Reson. Med. , vol.59 , pp. 667-672
    • Helms, G.1    Dathe, H.2    Dechent, P.3
  • 12
    • 57149103503 scopus 로고    scopus 로고
    • High-resolution maps of magnetization transfer with inherent correction for RF inhomogeneity and T1 relaxation obtained from 3D FLASH MRI
    • Helms, G., Dathe, H., Kallenberg, K., and Dechent, P. (2008b). High-resolution maps of magnetization transfer with inherent correction for RF inhomogeneity and T1 relaxation obtained from 3D FLASH MRI. Magn. Reson. Med. 60, 1396-1407. doi: 10.1002/mrm.21732
    • (2008) Magn. Reson. Med. , vol.60 , pp. 1396-1407
    • Helms, G.1    Dathe, H.2    Kallenberg, K.3    Dechent, P.4
  • 13
    • 67349261098 scopus 로고    scopus 로고
    • Improved segmentation of deep brain grey matter structures using magnetization transfer (MT) parameter maps
    • Helms, G., Draganski, B., Frackowiak, R., Ashburner, J., and Weiskopf, N. (2009). Improved segmentation of deep brain grey matter structures using magnetization transfer (MT) parameter maps. Neuroimage 47, 194-198. doi: 10.1016/j.neuroimage.2009.03.053
    • (2009) Neuroimage , vol.47 , pp. 194-198
    • Helms, G.1    Draganski, B.2    Frackowiak, R.3    Ashburner, J.4    Weiskopf, N.5
  • 14
    • 84890794337 scopus 로고    scopus 로고
    • Reproduction of motion artifacts for performance analysis of prospective motion correction in MRI
    • Herbst, M., Maclaren, J., Lovell-Smith, C., Sostheim, R., Egger, K., Harloff, A., et al. (2014). Reproduction of motion artifacts for performance analysis of prospective motion correction in MRI. Magn. Reson. Med. 71, 182-190. doi: 10.1002/mrm.24645
    • (2014) Magn. Reson. Med. , vol.71 , pp. 182-190
    • Herbst, M.1    Maclaren, J.2    Lovell-Smith, C.3    Sostheim, R.4    Egger, K.5    Harloff, A.6
  • 15
    • 84856228975 scopus 로고    scopus 로고
    • Prospective motion correction with continuous gradient updates in diffusion weighted imaging
    • Herbst, M., Maclaren, J., Weigel, M., Korvink, J., Hennig, J., and Zaitsev, M. (2012). Prospective motion correction with continuous gradient updates in diffusion weighted imaging. Magn. Reson. Med. 67, 326-338. doi: 10.1002/mrm.23230
    • (2012) Magn. Reson. Med. , vol.67 , pp. 326-338
    • Herbst, M.1    Maclaren, J.2    Weigel, M.3    Korvink, J.4    Hennig, J.5    Zaitsev, M.6
  • 16
    • 84946263679 scopus 로고
    • Robust regression using iteratively reweighted least-squares
    • Holland, P. W., and Welsch, R. E. (1977). Robust regression using iteratively reweighted least-squares. Commun. Stat. Theory Methods 6, 813-827. doi: 10.1080/03610927708827533
    • (1977) Commun. Stat. Theory Methods , vol.6 , pp. 813-827
    • Holland, P.W.1    Welsch, R.E.2
  • 17
    • 33751504686 scopus 로고    scopus 로고
    • Retrospective motion correction protocol for high-resolution anatomical MRI
    • Kochunov, P., Lancaster, J. L., Glahn, D. C., Purdy, D., Laird, A. R., Gao, F., et al. (2006). Retrospective motion correction protocol for high-resolution anatomical MRI. Hum. Brain Mapp. 27, 957-962. doi: 10.1002/hbm.20235
    • (2006) Hum. Brain Mapp. , vol.27 , pp. 957-962
    • Kochunov, P.1    Lancaster, J.L.2    Glahn, D.C.3    Purdy, D.4    Laird, A.R.5    Gao, F.6
  • 18
    • 77958574421 scopus 로고    scopus 로고
    • Quantitative MR imaging of brain iron: a postmortem validation study
    • Langkammer, C., Krebs, N., Goessler, W., Scheurer, E., Ebner, F., Yen, K., et al. (2010). Quantitative MR imaging of brain iron: a postmortem validation study. Radiology 257, 455-462. doi: 10.1148/radiol.10100495
    • (2010) Radiology , vol.257 , pp. 455-462
    • Langkammer, C.1    Krebs, N.2    Goessler, W.3    Scheurer, E.4    Ebner, F.5    Yen, K.6
  • 19
    • 34547816554 scopus 로고    scopus 로고
    • Image metric-based correction (autofocusing) of motion artifacts in high-resolution trabecular bone imaging
    • Lin, W., Ladinsky, G. A., Wehrli, F. W., and Song, H. K. (2007). Image metric-based correction (autofocusing) of motion artifacts in high-resolution trabecular bone imaging. J. Magn. Reson. Imaging 26, 191-197. doi: 10.1002/jmri.20958
    • (2007) J. Magn. Reson. Imaging , vol.26 , pp. 191-197
    • Lin, W.1    Ladinsky, G.A.2    Wehrli, F.W.3    Song, H.K.4
  • 20
    • 0030877021 scopus 로고    scopus 로고
    • Quantitative regional brain water measurement with magnetic resonance imaging in a focal ischemia model
    • Lin, W., Paczynski, R. P., Venkatesan, R., He, Y. Y., Powers, W. J., Hsu, C. Y., et al. (1997). Quantitative regional brain water measurement with magnetic resonance imaging in a focal ischemia model. Magn. Reson. Med. 38, 303-310. doi: 10.1002/mrm.1910380221
    • (1997) Magn. Reson. Med. , vol.38 , pp. 303-310
    • Lin, W.1    Paczynski, R.P.2    Venkatesan, R.3    He, Y.Y.4    Powers, W.J.5    Hsu, C.Y.6
  • 21
    • 84903480132 scopus 로고    scopus 로고
    • Using high-resolution quantitative mapping of R1 as an index of cortical myelination
    • Lutti, A., Dick, F., Sereno, M. I., and Weiskopf, N. (2014). Using high-resolution quantitative mapping of R1 as an index of cortical myelination. Neuroimage 93(Pt 2), 176-188. doi: 10.1016/j.neuroimage.2013.06.005
    • (2014) Neuroimage , vol.93 , pp. 176-188
    • Lutti, A.1    Dick, F.2    Sereno, M.I.3    Weiskopf, N.4
  • 22
    • 84858040838 scopus 로고    scopus 로고
    • Robust and fast whole brain mapping of the RF transmit field B1 at 7T
    • Lutti, A., Stadler, J., Josephs, O., Windischberger, C., Speck, O., Bernarding, J., et al. (2012). Robust and fast whole brain mapping of the RF transmit field B1 at 7T. PLoS ONE 7:e32379. doi: 10.1371/journal.pone.0032379
    • (2012) PLoS ONE , vol.7 , pp. e32379
    • Lutti, A.1    Stadler, J.2    Josephs, O.3    Windischberger, C.4    Speck, O.5    Bernarding, J.6
  • 23
    • 84868673863 scopus 로고    scopus 로고
    • Measurement and correction of microscopic head motion during magnetic resonance imaging of the brain
    • Maclaren, J., Armstrong, B. S. R., Barrows, R. T., Danishad, K. A., Ernst, T., Foster, C. L., et al. (2012). Measurement and correction of microscopic head motion during magnetic resonance imaging of the brain. PLoS ONE 7:e48088. doi: 10.1371/journal.pone.0048088
    • (2012) PLoS ONE , vol.7 , pp. e48088
    • Maclaren, J.1    Armstrong, B.S.R.2    Barrows, R.T.3    Danishad, K.A.4    Ernst, T.5    Foster, C.L.6
  • 24
    • 80052965850 scopus 로고    scopus 로고
    • Quantitative T*2-mapping based on multi-slice multiple gradient echo flash imaging: retrospective correction for subject motion effects
    • Magerkurth, J., Volz, S., Wagner, M., Jurcoane, A., Anti, S., Seiler, A., et al. (2011). Quantitative T*2-mapping based on multi-slice multiple gradient echo flash imaging: retrospective correction for subject motion effects. Magn. Reson. Med. 66, 989-997. doi: 10.1002/mrm.22878
    • (2011) Magn. Reson. Med. , vol.66 , pp. 989-997
    • Magerkurth, J.1    Volz, S.2    Wagner, M.3    Jurcoane, A.4    Anti, S.5    Seiler, A.6
  • 25
    • 0036754787 scopus 로고    scopus 로고
    • Distortion correction and robust tensor estimation for MR diffusion imaging
    • Mangin, J.-F., Poupon, C., Clark, C., Le Bihan, D., and Bloch, I. (2002). Distortion correction and robust tensor estimation for MR diffusion imaging. Med. Image Anal. 6, 191-198. doi: 10.1016/S1361-8415(02)00079-8
    • (2002) Med. Image Anal. , vol.6 , pp. 191-198
    • Mangin, J.-F.1    Poupon, C.2    Clark, C.3    Le Bihan, D.4    Bloch, I.5
  • 26
    • 0026135419 scopus 로고
    • Robust regression methods for computer vision: a review
    • Meer, P., Mintz, D., Rosenfeld, A., and Kim, D. Y. (1991). Robust regression methods for computer vision: a review. Int. J. Comput. Vision 6, 59-70. doi: 10.1007/BF00127126
    • (1991) Int. J. Comput. Vision , vol.6 , pp. 59-70
    • Meer, P.1    Mintz, D.2    Rosenfeld, A.3    Kim, D.Y.4
  • 27
    • 84873296556 scopus 로고    scopus 로고
    • The impact of post-processing on spinal cord diffusion tensor imaging
    • Mohammadi, S., Freund, P., Feiweier, T., Curt, A., and Weiskopf, N. (2013a). The impact of post-processing on spinal cord diffusion tensor imaging. Neuroimage 70, 377-385. doi: 10.1016/j.neuroimage.2012.12.058
    • (2013) Neuroimage , vol.70 , pp. 377-385
    • Mohammadi, S.1    Freund, P.2    Feiweier, T.3    Curt, A.4    Weiskopf, N.5
  • 28
    • 84881137953 scopus 로고    scopus 로고
    • Retrospective correction of physiological noise in DTI using an extended tensor model and peripheral measurements
    • Mohammadi, S., Hutton, C., Nagy, Z., Josephs, O., and Weiskopf, N. (2013b). Retrospective correction of physiological noise in DTI using an extended tensor model and peripheral measurements. Magn. Reson. Med. 70, 358-369. doi: 10.1002/mrm.24467
    • (2013) Magn. Reson. Med. , vol.70 , pp. 358-369
    • Mohammadi, S.1    Hutton, C.2    Nagy, Z.3    Josephs, O.4    Weiskopf, N.5
  • 29
    • 33744942355 scopus 로고    scopus 로고
    • A new method for fast quantitative mapping of absolute water content in vivo
    • Neeb, H., Zilles, K., and Shah, N. J. (2006). A new method for fast quantitative mapping of absolute water content in vivo. Neuroimage 31, 1156-1168. doi: 10.1016/j.neuroimage.2005.12.063
    • (2006) Neuroimage , vol.31 , pp. 1156-1168
    • Neeb, H.1    Zilles, K.2    Shah, N.J.3
  • 30
    • 84896294785 scopus 로고    scopus 로고
    • An improved method for retrospective motion correction in quantitative T2* mapping
    • No¨th, U., Volz, S., Hattingen, E., and Deichmann, R. (2014). An improved method for retrospective motion correction in quantitative T2* mapping. Neuroimage 92, 106-119. doi: 10.1016/j.neuroimage.2014.01.050
    • (2014) Neuroimage , vol.92 , pp. 106-119
    • No¨th, U.1    Volz, S.2    Hattingen, E.3    Deichmann, R.4
  • 31
    • 0028142827 scopus 로고
    • Assessment of relative brain iron concentrations using T2*-weighted and T2*-weighted MRI at 3 Tesla
    • Ordidge, R. J., Gorell, J. M., Deniau, J. C., Knight, R. A., and Helpern, J. A. (1994). Assessment of relative brain iron concentrations using T2*-weighted and T2*-weighted MRI at 3 Tesla. Magn. Reson. Med. 32, 335-341. doi: 10.1002/mrm.1910320309
    • (1994) Magn. Reson. Med. , vol.32 , pp. 335-341
    • Ordidge, R.J.1    Gorell, J.M.2    Deniau, J.C.3    Knight, R.A.4    Helpern, J.A.5
  • 32
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging
    • Pipe, J. G. (1999). Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn. Reson. Med. 42, 963-969.
    • (1999) Magn. Reson. Med. , vol.42 , pp. 963-969
    • Pipe, J.G.1
  • 33
    • 0037330814 scopus 로고    scopus 로고
    • Single-shot T(2)* mapping with 3D compensation of local susceptibility gradients in multiple regions
    • Posse, S., Shen, Z., Kiselev, V., and Kemna, L. J. (2003). Single-shot T(2)* mapping with 3D compensation of local susceptibility gradients in multiple regions. Neuroimage 18, 390-400. doi: 10.1016/S1053-8119(02)00016-2
    • (2003) Neuroimage , vol.18 , pp. 390-400
    • Posse, S.1    Shen, Z.2    Kiselev, V.3    Kemna, L.J.4
  • 34
    • 4444310685 scopus 로고    scopus 로고
    • Magnetization transfer ratio and myelin in postmortem multiple sclerosis brain
    • Schmierer, K., Scaravilli, F., Altmann, D. R., Barker, G. J., and Miller, D. H. (2004). Magnetization transfer ratio and myelin in postmortem multiple sclerosis brain. Ann. Neurol. 56, 407-415. doi: 10.1002/ana.20202
    • (2004) Ann. Neurol. , vol.56 , pp. 407-415
    • Schmierer, K.1    Scaravilli, F.2    Altmann, D.R.3    Barker, G.J.4    Miller, D.H.5
  • 35
    • 84880324813 scopus 로고    scopus 로고
    • Mapping the human cortical surface by combining quantitative T1 with retinotopy
    • Sereno, M. I., Lutti, A., Weiskopf, N., and Dick, F. (2013). Mapping the human cortical surface by combining quantitative T1 with retinotopy. Cereb. Cortex 23, 2261-2268. doi: 10.1093/cercor/bhs213
    • (2013) Cereb. Cortex , vol.23 , pp. 2261-2268
    • Sereno, M.I.1    Lutti, A.2    Weiskopf, N.3    Dick, F.4
  • 37
    • 77952554376 scopus 로고    scopus 로고
    • Origin and reduction of motion and f0 artifacts in high resolution T2*-weighted magnetic resonance imaging: application in Alzheimer's disease patients
    • Versluis, M. J., Peeters, J. M., van Rooden, S., van der Grond, J., van Buchem, M. A., Webb, A. G., et al. (2010). Origin and reduction of motion and f0 artifacts in high resolution T2*-weighted magnetic resonance imaging: application in Alzheimer's disease patients. Neuroimage 51, 1082-1088. doi: 10.1016/j.neuroimage.2010.03.048
    • (2010) Neuroimage , vol.51 , pp. 1082-1088
    • Versluis, M.J.1    Peeters, J.M.2    van Rooden, S.3    van der Grond, J.4    van Buchem, M.A.5    Webb, A.G.6
  • 38
    • 78650194424 scopus 로고    scopus 로고
    • Unified segmentation based correction of R1 brain maps for RF transmit field inhomogeneities (UNICORT)
    • Weiskopf, N., Lutti, A., Helms, G., Novak, M., Ashburner, J., and Hutton, C. (2011). Unified segmentation based correction of R1 brain maps for RF transmit field inhomogeneities (UNICORT). Neuroimage 54, 2116-2124. doi: 10.1016/j.neuroimage.2010.10.023
    • (2011) Neuroimage , vol.54 , pp. 2116-2124
    • Weiskopf, N.1    Lutti, A.2    Helms, G.3    Novak, M.4    Ashburner, J.5    Hutton, C.6
  • 39
    • 84892367098 scopus 로고    scopus 로고
    • Quantitative multi-parameter mapping of R1, PD*, MT, and R2* at 3T: a multi-center validation
    • Weiskopf, N., Suckling, J., Williams, G., Correia, M. M., Inkster, B., Tait, R., et al. (2013). Quantitative multi-parameter mapping of R1, PD*, MT, and R2* at 3T: a multi-center validation. Front. Neurosci. 7:95. doi: 10.3389/fnins.2013.00095
    • (2013) Front. Neurosci. , vol.7
    • Weiskopf, N.1    Suckling, J.2    Williams, G.3    Correia, M.M.4    Inkster, B.5    Tait, R.6
  • 40
    • 84868524848 scopus 로고    scopus 로고
    • Fiber orientation-dependent white matter contrast in gradient echo MRI
    • Wharton, S., and Bowtell, R. (2012). Fiber orientation-dependent white matter contrast in gradient echo MRI. Proc. Natl. Acad. Sci. U.S.A. 109, 18559-18564. doi: 10.1073/pnas.1211075109
    • (2012) Proc. Natl. Acad. Sci. U.S.A. , vol.109 , pp. 18559-18564
    • Wharton, S.1    Bowtell, R.2
  • 41
    • 33744908028 scopus 로고    scopus 로고
    • Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking system
    • Zaitsev, M., Dold, C., Sakas, G., Hennig, J., and Speck, O. (2006). Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking system. Neuroimage 31, 1038-1050. doi: 10.1016/j.neuroimage.2006.01.039
    • (2006) Neuroimage , vol.31 , pp. 1038-1050
    • Zaitsev, M.1    Dold, C.2    Sakas, G.3    Hennig, J.4    Speck, O.5
  • 42
    • 77956060332 scopus 로고    scopus 로고
    • Patching cardiac and head motion artefacts in diffusion-weighted images
    • Zwiers, M. P. (2010). Patching cardiac and head motion artefacts in diffusion-weighted images. Neuroimage 53, 565-575. doi: 10.1016/j.neuroimage.2010.06.014
    • (2010) Neuroimage , vol.53 , pp. 565-575
    • Zwiers, M.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.