메뉴 건너뛰기




Volumn 15, Issue 5, 2014, Pages 196-206

A six-year review of more than 13,000 patient-specific IMRT QA results from 13 different treatment sites

Author keywords

Gamma; IMRT QA; Patient specific QA; Quality assurance

Indexed keywords


EID: 84907022995     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v15i5.4935     Document Type: Article
Times cited : (33)

References (14)
  • 1
    • 84864701518 scopus 로고    scopus 로고
    • 3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification
    • Carrasco P, Jornet N, Latoree A, Eudaldo T, Ruiz A, Ribas M. 3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification. Med Phys. 2012;39(8):5040-49.
    • (2012) Med Phys , vol.39 , Issue.8 , pp. 5040-5049
    • Carrasco, P.1    Jornet, N.2    Latoree, A.3    Eudaldo, T.4    Ruiz, A.5    Ribas, M.6
  • 2
    • 80053595703 scopus 로고    scopus 로고
    • Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA
    • Zhen H, Nelms BE, Tome WA. Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA. Med Phys. 2011;38(10):5477-89.
    • (2011) Med Phys , vol.38 , Issue.10 , pp. 5477-5489
    • Zhen, H.1    Nelms, B.E.2    Tome, W.A.3
  • 3
    • 77953520249 scopus 로고    scopus 로고
    • Catching errors with in vivo EPID dosimetry
    • Mans A, Wendling M, McDermott LN, et al. Catching errors with in vivo EPID dosimetry. Med Phys. 2010;37(6):2638-44.
    • (2010) Med Phys , vol.37 , Issue.6 , pp. 2638-2644
    • Mans, A.1    Wendling, M.2    McDermott, L.N.3
  • 4
    • 38149131763 scopus 로고    scopus 로고
    • The next step in patient-specific QA: 3D dose verification of conformal and intensity-modulated RT based on EPID dosimetry and Monte Carlo dose calculations
    • van Elmpt W, Nijsten S, Mijnheer B, Dekker A, Lambin P. The next step in patient-specific QA: 3D dose verification of conformal and intensity-modulated RT based on EPID dosimetry and Monte Carlo dose calculations. Radiother Oncol. 2008;86(1):86-92.
    • (2008) Radiother Oncol , vol.86 , Issue.1 , pp. 86-92
    • van Elmpt, W.1    Nijsten, S.2    Mijnheer, B.3    Dekker, A.4    Lambin, P.5
  • 5
    • 84863527560 scopus 로고    scopus 로고
    • On using 3D γ-analysis for IMRT and VMAT pretreatment plan QA
    • Wu C, Hosier K, Beck K, et al. On using 3D γ-analysis for IMRT and VMAT pretreatment plan QA. Med Phys. 2012;39(6):3051-59.
    • (2012) Med Phys , vol.39 , Issue.6 , pp. 3051-3059
    • Wu, C.1    Hosier, K.2    Beck, K.3
  • 6
    • 77953487894 scopus 로고    scopus 로고
    • On the insensitivity of single field planar dosimetry to IMRT inaccuracies
    • Kruse JJ. On the insensitivity of single field planar dosimetry to IMRT inaccuracies. Med Phys. 2010;37(6):2516-24.
    • (2010) Med Phys , vol.37 , Issue.6 , pp. 2516-2524
    • Kruse, J.J.1
  • 8
    • 70350726816 scopus 로고    scopus 로고
    • IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119
    • Ezzell GA, Burmeister JW, Dogan N, et al. IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys. 2009;36(11):5359-73.
    • (2009) Med Phys , vol.36 , Issue.11 , pp. 5359-5373
    • Ezzell, G.A.1    Burmeister, J.W.2    Dogan, N.3
  • 9
    • 0038281222 scopus 로고    scopus 로고
    • Patient-specific point dose measurement for IMRT monitor unit verification
    • Dong L, Antolak J, Salehpour M, et al. Patient-specific point dose measurement for IMRT monitor unit verification. Int J Radiat Oncol Biol Phys. 2003;56(3):867-77.
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , Issue.3 , pp. 867-877
    • Dong, L.1    Antolak, J.2    Salehpour, M.3
  • 10
    • 79960560107 scopus 로고    scopus 로고
    • Eight years of IMRT quality assurance with ionization chambers and film dosimetry: experience of the Montpellier Comprehensive Cancer Center
    • Fenoglietto P, Laliberte B, Ailleres N, Riou O, Dubois JB, Azria D. Eight years of IMRT quality assurance with ionization chambers and film dosimetry: experience of the Montpellier Comprehensive Cancer Center. Radiat Oncol. 2011;6:1-11.
    • (2011) Radiat Oncol , vol.6 , pp. 1-11
    • Fenoglietto, P.1    Laliberte, B.2    Ailleres, N.3    Riou, O.4    Dubois, J.B.5    Azria, D.6
  • 12
    • 34548231706 scopus 로고    scopus 로고
    • A survey on planar IMRT QA analysis
    • Nelms BE and Simon JA. A survey on planar IMRT QA analysis. J Appl Clin Med Phys. 2007;8(3):76-90.
    • (2007) J Appl Clin Med Phys , vol.8 , Issue.3 , pp. 76-90
    • Nelms, B.E.1    Simon, J.A.2
  • 14
    • 57049164216 scopus 로고    scopus 로고
    • Establishing action levels for EPID-based QA for IMRT
    • Howell RM, Smith IPN, Jarrio CS. Establishing action levels for EPID-based QA for IMRT. J Appl Clin Med Phys. 2008:9(3):16-25.
    • (2008) J Appl Clin Med Phys , vol.9 , Issue.3 , pp. 16-25
    • Howell, R.M.1    Smith, I.P.N.2    Jarrio, C.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.