1
-
-
84906939369
-
National Committee for Clinical Laboratories Standards (NCCLS) document H18-A2
-
Wayne, PA: NCCLS
-
National Committee for Clinical Laboratories Standards (NCCLS) document H18-A2. Procedures of the handling and processing of blood specimens. Wayne, PA: NCCLS, 1999.
-
(1999)
Procedures of the Handling and Processing of Blood Specimens
-
-
-
2
-
-
0021403122
-
Effect of use of gel-barrier sampling tubes on determination of some antiepileptic drugs in serum
-
Bergqvist Y, Eckerbom S, Funding L. Effect of use of gel-barrier sampling tubes on determination of some antiepileptic drugs in serum. Clin Chem 1984;30:465-6.
-
(1984)
Clin Chem
, vol.30
, pp. 465-466
-
-
Bergqvist, Y.1
Eckerbom, S.2
Funding, L.3
-
3
-
-
0025089944
-
Stability of phenytoin in blood collected in vacuum blood collection tubes
-
Parish RC, Alexander T. Stability of phenytoin in blood collected in vacuum blood collection tubes. Ther Drug Monit 1990;12:85-9. (Pubitemid 20034694)
-
(1990)
Therapeutic Drug Monitoring
, vol.12
, Issue.1
, pp. 85-89
-
-
Parish, R.C.1
Alexander, T.2
-
4
-
-
0027179154
-
Evaluation of evacuated blood-collection tubes: Effects of three types of polymeric separators on therapeutic drug-monitoring specimens
-
Landt M, Smith CH, Hortin GL. Evaluation of evacuated blood-collection tubes: effects of three types of polymeric separators on therapeutic drug-monitoring specimens. Clin Chem 1993;39:1712-17. (Pubitemid 23246007)
-
(1993)
Clinical Chemistry
, vol.39
, Issue.8
, pp. 1712-1717
-
-
Landt, M.1
Smith, C.H.2
Hortin, G.L.3
-
5
-
-
0028205320
-
Absorption of therapeutic drugs by barrier gels in serum separator blood collection tubes: Volume- and time-dependent reduction in total and free drug concentrations
-
Dasgupta A, Dean R, Saldana S, et al. Absorption of therapeutic drugs by barrier gels in serum separator blood collection tubes. Volume- and time-dependent reduction in total and free drug concentrations. Am J Clin Pathol 1994;101:456-61. (Pubitemid 24123236)
-
(1994)
American Journal of Clinical Pathology
, vol.101
, Issue.4
, pp. 456-461
-
-
Dasgupta, A.1
Dean, R.2
Saldana, S.3
Kinnaman, G.4
McLawhon, R.W.5
-
6
-
-
0029996763
-
Stability of therapeutic drug measurement in specimens collected in VACUTAINER plastic blood-collection tubes
-
DOI 10.1097/00007691-199606000-00016
-
Dasgupta A, Blackwell W, Bard D. Stability of therapeutic drug measurement in specimens collected in VACUTAINER plastic blood-collection tubes. Ther Drug Monit 1996;18:306-9. (Pubitemid 26159585)
-
(1996)
Therapeutic Drug Monitoring
, vol.18
, Issue.3
, pp. 306-309
-
-
Dasgupta, A.1
Blackwell, W.2
Bard, D.3
-
7
-
-
0035023630
-
Stability of therapeutic drugs in serum collected in vacutainer serum separator tubes containing a new gel (SST II)
-
DOI 10.1097/00007691-200106000-00013
-
Bush V, Blennerhasset J, Wells A, et al. Stability of therapeutic drugs in serum collected in vacutainer serum separator tubes containing a new gel (SST II). Ther Drug Monit 2001;23:259-62. Erratum in: Ther Drug Monit 2001;23:738. (Pubitemid 32476554)
-
(2001)
Therapeutic Drug Monitoring
, vol.23
, Issue.3
, pp. 259-262
-
-
Bush, V.1
Blennerhasset, J.2
Wells, A.3
Dasgupta, A.4
-
8
-
-
0033934632
-
Suitability of collection tubes with separator gels for collecting and storing blood samples for therapeutic drug monitoring (TDM)
-
Karppi J, Akerman KK, Parviainen M. Suitability of collection tubes with separator gels for collecting and storing blood samples for therapeutic drug monitoring. Clin Chem Lab Med 2000;38:313-20. (Pubitemid 30444958)
-
(2000)
Clinical Chemistry and Laboratory Medicine
, vol.38
, Issue.4
, pp. 313-320
-
-
Karppi, J.1
Akerman, K.K.2
Parviainen, M.3
-
9
-
-
1642484493
-
Evaluation of a new generation of plastic evacuated blood-collection tubes in clinical chemistry, therapeutic drug monitoring, hormone and trace metal analysis
-
DOI 10.1515/CCLM.2004.013
-
Boeynaems JM, De Leener A, Dessars B, et al. Evaluation of a new generation of plastic evacuated blood-collection tubes in clinical chemistry, therapeutic drug monitoring, hormone and trace metal analysis. Clin Chem Lab Med 2004;42:67-71. (Pubitemid 38401471)
-
(2004)
Clinical Chemistry and Laboratory Medicine
, vol.42
, Issue.1
, pp. 67-71
-
-
Boeynaems, J.-M.1
De Leener, A.2
Dessars, B.3
Villa-Lobos, H.R.4
Aubry, J.-C.5
Cotton, F.6
Thiry, P.7
-
11
-
-
77952538807
-
Evaluation of the Becton-Dickinson rapid serum tube: Does it provide a suitable alternative to lithium heparin plasma tubes?
-
Dimeski G, Masci PP, Trabi M, et al. Evaluation of the Becton-Dickinson rapid serum tube: does it provide a suitable alternative to lithium heparin plasma tubes? Clin Chem Lab Med 2010;48:651-7.
-
(2010)
Clin Chem Lab Med
, vol.48
, pp. 651-657
-
-
Dimeski, G.1
Masci, P.P.2
Trabi, M.3
-
12
-
-
79960994838
-
Use of the BD vacutainer rapid serum tube reduces false-positive results for selected beckman coulter Unicel DxI immunoassays
-
Strathmann FG, Ka MM, Rainey PM, et al. Use of the BD vacutainer rapid serum tube reduces false-positive results for selected beckman coulter Unicel DxI immunoassays. Am J Clin Pathol 2011;136:325-9.
-
(2011)
Am J Clin Pathol
, vol.136
, pp. 325-329
-
-
Strathmann, F.G.1
Ka, M.M.2
Rainey, P.M.3
-
13
-
-
84862552219
-
BD rapid serum tubes reduce false positive plasma troponin T results on the Roche Cobas e411 analyzer
-
Koch CD, Wockenfus AM, Saenger AK, et al. BD rapid serum tubes reduce false positive plasma troponin T results on the Roche Cobas e411 analyzer. Clin Biochem 2012;45:842-4.
-
(2012)
Clin Biochem
, vol.45
, pp. 842-844
-
-
Koch, C.D.1
Wockenfus, A.M.2
Saenger, A.K.3
-
14
-
-
84899534084
-
Studies on the use of BD Vacutainer(R) SST II™ and RST™ in general practice: Investigation of artefactual hyperkalaemia
-
Huyghe T, Buntinx F, Bruyninckx R, et al. Studies on the use of BD Vacutainer(R) SST II™ and RST™ in general practice: investigation of artefactual hyperkalaemia. Ann Clin Biochem 2014;51:30-7.
-
(2014)
Ann Clin Biochem
, vol.51
, pp. 30-37
-
-
Huyghe, T.1
Buntinx, F.2
Bruyninckx, R.3
-
15
-
-
84904353619
-
Comparison of Becton Dickinson Vacutainer rapid serum tube with the serum separator tube for routine chemistry and immunoassay tests
-
Yan R, Lou A, Watts G, et al. Comparison of Becton Dickinson Vacutainer rapid serum tube with the serum separator tube for routine chemistry and immunoassay tests. J Clin Pathol 2014;67:599-604.
-
(2014)
J Clin Pathol
, vol.67
, pp. 599-604
-
-
Yan, R.1
Lou, A.2
Watts, G.3
-
16
-
-
12944293053
-
Effect of blood collection tubes on total triiodothyronine and other laboratory assays
-
DOI 10.1373/clinchem.2004.043349
-
Bowen RA, Chan Y, Cohen J, et al. Effect of blood collection tubes on total triiodothyronine and other laboratory assays. Clin Chem 2005;51:424-33. (Pubitemid 40175814)
-
(2005)
Clinical Chemistry
, vol.51
, Issue.2
, pp. 424-433
-
-
Bowen, R.A.R.1
Chan, Y.2
Cohen, J.3
Rehak, N.N.4
Hortin, G.L.5
Csako, G.6
Remaley, A.T.7
-
17
-
-
4043135924
-
The use of recalcified citrated whole blood - A pragmatic approach for thromboelastography in children
-
DOI 10.1111/j.1460-9592.2004.01275.x
-
Rajwal S, Richards M, O'Meara M. The use of recalcified citrated whole blood - a pragmatic approach for thromboelastography in children. Pediatri Anesth 2004;14:656-60. (Pubitemid 39070560)
-
(2004)
Paediatric Anaesthesia
, vol.14
, Issue.8
, pp. 656-660
-
-
Rajwal, S.1
Richards, M.2
O'Meara, M.3
-
18
-
-
34548840835
-
Citrate anticoagulation and the dynamics of thrombin generation
-
DOI 10.1111/j.1538-7836.2007.02710.x
-
Mann KG, Whelihan MF, Butenas S, et al. Citrate anticoagulation and the dynamics of thrombin generation. J Thromb Haemost 2007;5:2055-61. (Pubitemid 47450024)
-
(2007)
Journal of Thrombosis and Haemostasis
, vol.5
, Issue.10
, pp. 2055-2061
-
-
Mann, K.G.1
Whelihan, M.F.2
Butenas, S.3
Orfeo, T.4
-
20
-
-
84906939815
-
Evaluation of the BD Vacutainer® rapid serum tube for routine chemistry analytes on the Roche Cobas Integra® 800
-
BD. September
-
Becton Dickinson white paper. Evaluation of the BD Vacutainer® rapid serum tube for routine chemistry analytes on the Roche Cobas Integra® 800. BD. September 2009.
-
(2009)
Becton Dickinson White Paper
-
-
-
21
-
-
63849310153
-
Evaluation of the BD Vacutainer PST II blood collection tube for special chemistry analytes
-
Chance J, Berube J, Vandersmissen M, et al. Evaluation of the BD Vacutainer PST II blood collection tube for special chemistry analytes. Clin Chem Lab Med 2009;47:358-61.
-
(2009)
Clin Chem Lab Med
, vol.47
, pp. 358-361
-
-
Chance, J.1
Berube, J.2
Vandersmissen, M.3
-
22
-
-
0035490558
-
Complications of critical care: Lab testing and iatrogenic anemia
-
Woodhouse S. Complications of critical care: lab testing and iatrogenic anemia. MLO Med Lab Obs 2001;33:28-31.
-
(2001)
MLO Med Lab Obs
, vol.33
, pp. 28-31
-
-
Woodhouse, S.1
-
23
-
-
84872605318
-
Simulation of repetitive diagnostic blood loss and onset of iatrogenic anemia in critical care patients with a mathematical model
-
Lyon AW, Chin AC, Slotsve GA, et al. Simulation of repetitive diagnostic blood loss and onset of iatrogenic anemia in critical care patients with a mathematical model. Comput Biol Med 2013;43:84-90.
-
(2013)
Comput Biol Med
, vol.43
, pp. 84-90
-
-
Lyon, A.W.1
Chin, A.C.2
Slotsve, G.A.3
|