메뉴 건너뛰기




Volumn 67, Issue 9, 2014, Pages 807-810

Suitability of Becton Dickinson Vacutainer rapid serum tube for collecting and storing blood samples for antibiotic and anticonvulsant drug monitoring

Author keywords

[No Author keywords available]

Indexed keywords

ANTIBIOTIC AGENT; ANTICONVULSIVE AGENT; CARBAMAZEPINE; GENTAMICIN; LAMOTRIGINE; PHENYTOIN; VANCOMYCIN; ANTIINFECTIVE AGENT;

EID: 84906940169     PISSN: 00219746     EISSN: 14724146     Source Type: Journal    
DOI: 10.1136/jclinpath-2014-202466     Document Type: Article
Times cited : (12)

References (23)
  • 1
    • 84906939369 scopus 로고    scopus 로고
    • National Committee for Clinical Laboratories Standards (NCCLS) document H18-A2
    • Wayne, PA: NCCLS
    • National Committee for Clinical Laboratories Standards (NCCLS) document H18-A2. Procedures of the handling and processing of blood specimens. Wayne, PA: NCCLS, 1999.
    • (1999) Procedures of the Handling and Processing of Blood Specimens
  • 2
    • 0021403122 scopus 로고
    • Effect of use of gel-barrier sampling tubes on determination of some antiepileptic drugs in serum
    • Bergqvist Y, Eckerbom S, Funding L. Effect of use of gel-barrier sampling tubes on determination of some antiepileptic drugs in serum. Clin Chem 1984;30:465-6.
    • (1984) Clin Chem , vol.30 , pp. 465-466
    • Bergqvist, Y.1    Eckerbom, S.2    Funding, L.3
  • 3
    • 0025089944 scopus 로고
    • Stability of phenytoin in blood collected in vacuum blood collection tubes
    • Parish RC, Alexander T. Stability of phenytoin in blood collected in vacuum blood collection tubes. Ther Drug Monit 1990;12:85-9. (Pubitemid 20034694)
    • (1990) Therapeutic Drug Monitoring , vol.12 , Issue.1 , pp. 85-89
    • Parish, R.C.1    Alexander, T.2
  • 4
    • 0027179154 scopus 로고
    • Evaluation of evacuated blood-collection tubes: Effects of three types of polymeric separators on therapeutic drug-monitoring specimens
    • Landt M, Smith CH, Hortin GL. Evaluation of evacuated blood-collection tubes: effects of three types of polymeric separators on therapeutic drug-monitoring specimens. Clin Chem 1993;39:1712-17. (Pubitemid 23246007)
    • (1993) Clinical Chemistry , vol.39 , Issue.8 , pp. 1712-1717
    • Landt, M.1    Smith, C.H.2    Hortin, G.L.3
  • 5
    • 0028205320 scopus 로고
    • Absorption of therapeutic drugs by barrier gels in serum separator blood collection tubes: Volume- and time-dependent reduction in total and free drug concentrations
    • Dasgupta A, Dean R, Saldana S, et al. Absorption of therapeutic drugs by barrier gels in serum separator blood collection tubes. Volume- and time-dependent reduction in total and free drug concentrations. Am J Clin Pathol 1994;101:456-61. (Pubitemid 24123236)
    • (1994) American Journal of Clinical Pathology , vol.101 , Issue.4 , pp. 456-461
    • Dasgupta, A.1    Dean, R.2    Saldana, S.3    Kinnaman, G.4    McLawhon, R.W.5
  • 6
    • 0029996763 scopus 로고    scopus 로고
    • Stability of therapeutic drug measurement in specimens collected in VACUTAINER plastic blood-collection tubes
    • DOI 10.1097/00007691-199606000-00016
    • Dasgupta A, Blackwell W, Bard D. Stability of therapeutic drug measurement in specimens collected in VACUTAINER plastic blood-collection tubes. Ther Drug Monit 1996;18:306-9. (Pubitemid 26159585)
    • (1996) Therapeutic Drug Monitoring , vol.18 , Issue.3 , pp. 306-309
    • Dasgupta, A.1    Blackwell, W.2    Bard, D.3
  • 7
    • 0035023630 scopus 로고    scopus 로고
    • Stability of therapeutic drugs in serum collected in vacutainer serum separator tubes containing a new gel (SST II)
    • DOI 10.1097/00007691-200106000-00013
    • Bush V, Blennerhasset J, Wells A, et al. Stability of therapeutic drugs in serum collected in vacutainer serum separator tubes containing a new gel (SST II). Ther Drug Monit 2001;23:259-62. Erratum in: Ther Drug Monit 2001;23:738. (Pubitemid 32476554)
    • (2001) Therapeutic Drug Monitoring , vol.23 , Issue.3 , pp. 259-262
    • Bush, V.1    Blennerhasset, J.2    Wells, A.3    Dasgupta, A.4
  • 8
    • 0033934632 scopus 로고    scopus 로고
    • Suitability of collection tubes with separator gels for collecting and storing blood samples for therapeutic drug monitoring (TDM)
    • Karppi J, Akerman KK, Parviainen M. Suitability of collection tubes with separator gels for collecting and storing blood samples for therapeutic drug monitoring. Clin Chem Lab Med 2000;38:313-20. (Pubitemid 30444958)
    • (2000) Clinical Chemistry and Laboratory Medicine , vol.38 , Issue.4 , pp. 313-320
    • Karppi, J.1    Akerman, K.K.2    Parviainen, M.3
  • 11
    • 77952538807 scopus 로고    scopus 로고
    • Evaluation of the Becton-Dickinson rapid serum tube: Does it provide a suitable alternative to lithium heparin plasma tubes?
    • Dimeski G, Masci PP, Trabi M, et al. Evaluation of the Becton-Dickinson rapid serum tube: does it provide a suitable alternative to lithium heparin plasma tubes? Clin Chem Lab Med 2010;48:651-7.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 651-657
    • Dimeski, G.1    Masci, P.P.2    Trabi, M.3
  • 12
    • 79960994838 scopus 로고    scopus 로고
    • Use of the BD vacutainer rapid serum tube reduces false-positive results for selected beckman coulter Unicel DxI immunoassays
    • Strathmann FG, Ka MM, Rainey PM, et al. Use of the BD vacutainer rapid serum tube reduces false-positive results for selected beckman coulter Unicel DxI immunoassays. Am J Clin Pathol 2011;136:325-9.
    • (2011) Am J Clin Pathol , vol.136 , pp. 325-329
    • Strathmann, F.G.1    Ka, M.M.2    Rainey, P.M.3
  • 13
    • 84862552219 scopus 로고    scopus 로고
    • BD rapid serum tubes reduce false positive plasma troponin T results on the Roche Cobas e411 analyzer
    • Koch CD, Wockenfus AM, Saenger AK, et al. BD rapid serum tubes reduce false positive plasma troponin T results on the Roche Cobas e411 analyzer. Clin Biochem 2012;45:842-4.
    • (2012) Clin Biochem , vol.45 , pp. 842-844
    • Koch, C.D.1    Wockenfus, A.M.2    Saenger, A.K.3
  • 14
    • 84899534084 scopus 로고    scopus 로고
    • Studies on the use of BD Vacutainer(R) SST II™ and RST™ in general practice: Investigation of artefactual hyperkalaemia
    • Huyghe T, Buntinx F, Bruyninckx R, et al. Studies on the use of BD Vacutainer(R) SST II™ and RST™ in general practice: investigation of artefactual hyperkalaemia. Ann Clin Biochem 2014;51:30-7.
    • (2014) Ann Clin Biochem , vol.51 , pp. 30-37
    • Huyghe, T.1    Buntinx, F.2    Bruyninckx, R.3
  • 15
    • 84904353619 scopus 로고    scopus 로고
    • Comparison of Becton Dickinson Vacutainer rapid serum tube with the serum separator tube for routine chemistry and immunoassay tests
    • Yan R, Lou A, Watts G, et al. Comparison of Becton Dickinson Vacutainer rapid serum tube with the serum separator tube for routine chemistry and immunoassay tests. J Clin Pathol 2014;67:599-604.
    • (2014) J Clin Pathol , vol.67 , pp. 599-604
    • Yan, R.1    Lou, A.2    Watts, G.3
  • 17
    • 4043135924 scopus 로고    scopus 로고
    • The use of recalcified citrated whole blood - A pragmatic approach for thromboelastography in children
    • DOI 10.1111/j.1460-9592.2004.01275.x
    • Rajwal S, Richards M, O'Meara M. The use of recalcified citrated whole blood - a pragmatic approach for thromboelastography in children. Pediatri Anesth 2004;14:656-60. (Pubitemid 39070560)
    • (2004) Paediatric Anaesthesia , vol.14 , Issue.8 , pp. 656-660
    • Rajwal, S.1    Richards, M.2    O'Meara, M.3
  • 20
    • 84906939815 scopus 로고    scopus 로고
    • Evaluation of the BD Vacutainer® rapid serum tube for routine chemistry analytes on the Roche Cobas Integra® 800
    • BD. September
    • Becton Dickinson white paper. Evaluation of the BD Vacutainer® rapid serum tube for routine chemistry analytes on the Roche Cobas Integra® 800. BD. September 2009.
    • (2009) Becton Dickinson White Paper
  • 21
    • 63849310153 scopus 로고    scopus 로고
    • Evaluation of the BD Vacutainer PST II blood collection tube for special chemistry analytes
    • Chance J, Berube J, Vandersmissen M, et al. Evaluation of the BD Vacutainer PST II blood collection tube for special chemistry analytes. Clin Chem Lab Med 2009;47:358-61.
    • (2009) Clin Chem Lab Med , vol.47 , pp. 358-361
    • Chance, J.1    Berube, J.2    Vandersmissen, M.3
  • 22
    • 0035490558 scopus 로고    scopus 로고
    • Complications of critical care: Lab testing and iatrogenic anemia
    • Woodhouse S. Complications of critical care: lab testing and iatrogenic anemia. MLO Med Lab Obs 2001;33:28-31.
    • (2001) MLO Med Lab Obs , vol.33 , pp. 28-31
    • Woodhouse, S.1
  • 23
    • 84872605318 scopus 로고    scopus 로고
    • Simulation of repetitive diagnostic blood loss and onset of iatrogenic anemia in critical care patients with a mathematical model
    • Lyon AW, Chin AC, Slotsve GA, et al. Simulation of repetitive diagnostic blood loss and onset of iatrogenic anemia in critical care patients with a mathematical model. Comput Biol Med 2013;43:84-90.
    • (2013) Comput Biol Med , vol.43 , pp. 84-90
    • Lyon, A.W.1    Chin, A.C.2    Slotsve, G.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.