BD rapid serum tubes reduce false positive plasma troponin T results on the Roche Cobas e411 analyzer

Author keywords

Rapid serum tube; Troponin t

Indexed keywords

HEPARIN; LITHIUM; TROPONIN T;

EID: 84862552219     PISSN: 00099120     EISSN: 18732933     Source Type: Journal    
DOI: 10.1016/j.clinbiochem.2012.04.014     Document Type: Article
Times cited : (22)

References (6)
  • 1
    • 77951847805 scopus 로고    scopus 로고
    • Falsely elevated troponin I results due to outliers indicate a lack of analytical robustness
    • Ungerer J., Pretorius C., Dimenski G., O'Rourke P., Tyack S. Falsely elevated troponin I results due to outliers indicate a lack of analytical robustness. Ann Clin Biochem 2010, 47:242-247.
    • (2010) Ann Clin Biochem , vol.47 , pp. 242-247
    • Ungerer, J.1    Pretorius, C.2    Dimenski, G.3    O'Rourke, P.4    Tyack, S.5
  • 2
    • 79958269009 scopus 로고    scopus 로고
    • Evidence on the cause of false positive troponin I results with the Beckman AccuTnI method
    • Dimenski G. Evidence on the cause of false positive troponin I results with the Beckman AccuTnI method. Clin Chem Lab Med 2011, 49:1079-1080.
    • (2011) Clin Chem Lab Med , vol.49 , pp. 1079-1080
    • Dimenski, G.1
  • 3
    • 18144409063 scopus 로고    scopus 로고
    • False-positive troponin I measured with the Abbott Axsym attributed to fibrin interference
    • Kazmierczak S., Sekhon H., Richards C. False-positive troponin I measured with the Abbott Axsym attributed to fibrin interference. Int J Cardiol 2005, 101:27-31.
    • (2005) Int J Cardiol , vol.101 , pp. 27-31
    • Kazmierczak, S.1    Sekhon, H.2    Richards, C.3
  • 4
    • 33847671730 scopus 로고    scopus 로고
    • Results from a multicenter evaluation of the 4th generation elecsys troponin T assay
    • Hermsen D., Apple F., Garcia-Beltran L., Jaffe A., Karon B., Lewandrowski E., et al. Results from a multicenter evaluation of the 4th generation elecsys troponin T assay. Clin Lab 2007, 53:1-9.
    • (2007) Clin Lab , vol.53 , pp. 1-9
    • Hermsen, D.1    Apple, F.2    Garcia-Beltran, L.3    Jaffe, A.4    Karon, B.5    Lewandrowski, E.6
  • 5
    • 77952538807 scopus 로고    scopus 로고
    • Evaluation of the Becton-Dickinson rapid serum tube: Does it provide a suitable alternative to lithium heparin plasma tubes?
    • Dimenski G., Masci P., Trabi M., Lavin M., de Jersey J. Evaluation of the Becton-Dickinson rapid serum tube: Does it provide a suitable alternative to lithium heparin plasma tubes?. Clin Chem Lab Med 2010, 48:651-657.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 651-657
    • Dimenski, G.1    Masci, P.2    Trabi, M.3    Lavin, M.4    de Jersey, J.5
  • 6
    • 79960994838 scopus 로고    scopus 로고
    • Use of BD vacutainer rapid serum tube reduces false-positive results for selected Beckman Coulter Unicel DxI immunoassays
    • Strathmann F., Ka M., Rainey P., Baird G. Use of BD vacutainer rapid serum tube reduces false-positive results for selected Beckman Coulter Unicel DxI immunoassays. Am J Clin Pathol 2011, 136:325-329.
    • (2011) Am J Clin Pathol , vol.136 , pp. 325-329
    • Strathmann, F.1    Ka, M.2    Rainey, P.3    Baird, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.