메뉴 건너뛰기




Volumn 119, Issue 3, 2014, Pages 543-549

An evaluation of a zero-heat-flux cutaneous thermometer in cardiac surgical patients

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; CARDIOPULMONARY BYPASS; CORE TEMPERATURE; FEMALE; FOREHEAD; HUMAN; INTENSIVE CARE; MAJOR CLINICAL STUDY; MALE; MEDICAL THERMOMETER; POSTOPERATIVE CARE; PRIORITY JOURNAL; PULMONARY ARTERY CATHETER; SKIN SURFACE; TEMPERATURE MEASUREMENT; THERMISTOR;

EID: 84906940062     PISSN: 00032999     EISSN: 15267598     Source Type: Journal    
DOI: 10.1213/ANE.0000000000000319     Document Type: Article
Times cited : (132)

References (47)
  • 1
    • 0030961861 scopus 로고    scopus 로고
    • Perioperative maintenance of normothermia reduces the incidence of morbid cardiac events A randomized clinical trial
    • Frank SM, Fleisher LA, Breslow MJ, Higgins MS, Olson KF, Kelly S, Beattie C. Perioperative maintenance of normothermia reduces the incidence of morbid cardiac events. A randomized clinical trial. JAMA 1997;277:1127-34
    • (1997) JAMA , vol.277 , pp. 1127-1134
    • Frank, S.M.1    Fleisher, L.A.2    Breslow, M.J.3    Higgins, M.S.4    Olson, K.F.5    Kelly, S.6    Beattie, C.7
  • 2
    • 0029921767 scopus 로고    scopus 로고
    • Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization study of wound infection and temperature group
    • Kurz A, Sessler DI, Lenhardt R. Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization. Study of Wound Infection and Temperature Group. N Engl J Med 1996;334:1209-15
    • (1996) N Engl J Med , vol.334 , pp. 1209-1215
    • Kurz, A.1    Sessler, D.I.2    Lenhardt, R.3
  • 3
    • 0035883865 scopus 로고    scopus 로고
    • Effects of preoperative warming on the incidence of wound infection after clean surgery: A randomised controlled trial
    • Melling AC, Ali B, Scott EM, Leaper DJ. Effects of preoperative warming on the incidence of wound infection after clean surgery: A randomised controlled trial. Lancet 2001;358:876-80
    • (2001) Lancet , vol.358 , pp. 876-880
    • Melling, A.C.1    Ali, B.2    Scott, E.M.3    Leaper, D.J.4
  • 4
    • 37549061416 scopus 로고    scopus 로고
    • The effects of mild perioperative hypothermia on blood loss and transfusion requirement
    • Rajagopalan S, Mascha E, Na J, Sessler DI. The effects of mild perioperative hypothermia on blood loss and transfusion requirement. Anesthesiology 2008;108:71-7
    • (2008) Anesthesiology , vol.108 , pp. 71-77
    • Rajagopalan, S.1    Mascha, E.2    Na, J.3    Sessler, D.I.4
  • 7
    • 0030889304 scopus 로고    scopus 로고
    • Influence of thermoregulatory vasomotion and ambient temperature variation on the accuracy of core-Temperature estimates by cutaneous liquidcrystal thermometers
    • Ikeda T, Sessler DI, Marder D, Xiong J. Influence of thermoregulatory vasomotion and ambient temperature variation on the accuracy of core-Temperature estimates by cutaneous liquidcrystal thermometers. Anesthesiology 1997;86:603-12
    • (1997) Anesthesiology , vol.86 , pp. 603-612
    • Ikeda, T.1    Sessler, D.I.2    Marder, D.3    Xiong, J.4
  • 9
    • 0014987164 scopus 로고
    • A new technique for monitoring the deep body temperature in man from the intact skin surface
    • Fox RH, Solman AJ. A new technique for monitoring the deep body temperature in man from the intact skin surface. J Physiol 1971;212:8P-10P
    • (1971) J Physiol , vol.212
    • Fox, R.H.1    Solman, A.J.2
  • 10
    • 0015677269 scopus 로고
    • New thermometers for deep tissue temperature
    • Solman AJ, Dalton JC. New thermometers for deep tissue temperature. Biomed Eng 1973;8:432-5
    • (1973) Biomed Eng , vol.8 , pp. 432-435
    • Solman, A.J.1    Dalton, J.C.2
  • 11
    • 0015547160 scopus 로고
    • A new method for monitoring deep body temperature from the skin surface
    • Fox RH, Solman AJ, Isaacs R, Fry AJ, MacDonald IC. A new method for monitoring deep body temperature from the skin surface. Clin Sci 1973;44:81-6
    • (1973) Clin Sci , vol.44 , pp. 81-86
    • Fox, R.H.1    Solman, A.J.2    Isaacs, R.3    Fry, A.J.4    MacDonald, I.C.5
  • 14
    • 0024040995 scopus 로고
    • Improved probe for a deep body thermometer
    • Nemoto T, Togawa T. Improved probe for a deep body thermometer. Med Biol Eng Comput 1988;26:456-9
    • (1988) Med Biol Eng Comput , vol.26 , pp. 456-459
    • Nemoto, T.1    Togawa, T.2
  • 15
    • 0038261987 scopus 로고    scopus 로고
    • Deep temperature monitoring using a zero-heat-flow method
    • Yamakage M, Namiki A. Deep temperature monitoring using a zero-heat-flow method. J Anesth 2003;17:108-15
    • (2003) J Anesth , vol.17 , pp. 108-115
    • Yamakage, M.1    Namiki, A.2
  • 16
    • 0017841193 scopus 로고
    • A new method for the transcutaneous measurement of deep body temperature during anaesthesia and intensive care (author's transl)
    • Jost U, Hanf K, Köhler CO, Just OH. [A new method for the transcutaneous measurement of deep body temperature during anaesthesia and intensive care (author's transl)]. Prakt Anaesth 1978;13:144-9
    • (1978) Prakt Anaesth , vol.13 , pp. 144-149
    • Jost, U.1    Hanf, K.2    Köhler, C.O.3    Just, O.H.4
  • 17
    • 22144462818 scopus 로고    scopus 로고
    • Confounding factors in the use of the zero-heat-flow method for non-invasive muscle temperature measurement
    • Brajkovic D, Ducharme MB. Confounding factors in the use of the zero-heat-flow method for non-invasive muscle temperature measurement. Eur J Appl Physiol 2005;94:386-91
    • (2005) Eur J Appl Physiol , vol.94 , pp. 386-391
    • Brajkovic, D.1    Ducharme, M.B.2
  • 18
    • 0034465393 scopus 로고    scopus 로고
    • A new combined deep-body-Temperature/NIRs probe for noninvasive metabolic measurements on human skeletal muscle
    • Binzoni T, Springett R, Dalton JC, Delpy D. A new combined deep-body-Temperature/NIRs probe for noninvasive metabolic measurements on human skeletal muscle. Adv Exp Med Biol 1999;471:623-9
    • (1999) Adv Exp Med Biol , vol.471 , pp. 623-629
    • Binzoni, T.1    Springett, R.2    Dalton, J.C.3    Delpy, D.4
  • 19
    • 0023773212 scopus 로고
    • A tissue heat transfer model for relating dynamic skin temperature changes to physiological parameters
    • Wilson SB, Spence VA. A tissue heat transfer model for relating dynamic skin temperature changes to physiological parameters. Phys Med Biol 1988;33:895-912
    • (1988) Phys Med Biol , vol.33 , pp. 895-912
    • Wilson, S.B.1    Spence, V.A.2
  • 20
    • 0030882363 scopus 로고    scopus 로고
    • Postanesthetic vasoconstriction slows peripheral-To-core transfer of cutaneous heat, thereby isolating the core thermal compartment
    • Plattner O, Ikeda T, Sessler DI, Christensen R, Turakhia M. Postanesthetic vasoconstriction slows peripheral-To-core transfer of cutaneous heat, thereby isolating the core thermal compartment. Anesth Analg 1997;85:899-906
    • (1997) Anesth Analg , vol.85 , pp. 899-906
    • Plattner, O.1    Ikeda, T.2    Sessler, D.I.3    Christensen, R.4    Turakhia, M.5
  • 21
    • 0019276302 scopus 로고
    • Noninvasive determination of core temperature during anesthesia
    • Lees DE, Kim YD, Macnamara TE. Noninvasive determination of core temperature during anesthesia. South Med J 1980;73:1322-4
    • (1980) South Med J , vol.73 , pp. 1322-1324
    • Lees, D.E.1    Kim, Y.D.2    MacNamara, T.E.3
  • 22
    • 0033767823 scopus 로고    scopus 로고
    • Continuous measurement of core body temperature in preterm infants
    • Dollberg S, Rimon A, Atherton HD, Hoath SB. Continuous measurement of core body temperature in preterm infants. Am J Perinatol 2000;17:257-64
    • (2000) Am J Perinatol , vol.17 , pp. 257-264
    • Dollberg, S.1    Rimon, A.2    Atherton, H.D.3    Hoath, S.B.4
  • 23
    • 0027359330 scopus 로고
    • Deep body temperature during the warming phase of cardiopulmonary bypass
    • Sakuragi T, Mukai M, Dan K. Deep body temperature during the warming phase of cardiopulmonary bypass. Br J Anaesth 1993;71:583-5
    • (1993) Br J Anaesth , vol.71 , pp. 583-585
    • Sakuragi, T.1    Mukai, M.2    Dan, K.3
  • 25
    • 0023324425 scopus 로고
    • Twenty-four hour monitoring of deep body temperature with a novel flexible probe
    • Fukuoka M, Yamori Y, Toyoshima T. Twenty-four hour monitoring of deep body temperature with a novel flexible probe. J Biomed Eng 1987;9:173-6
    • (1987) J Biomed Eng , vol.9 , pp. 173-176
    • Fukuoka, M.1    Yamori, Y.2    Toyoshima, T.3
  • 26
    • 0023639893 scopus 로고
    • Patient monitoring during and after open heart surgery by an improved deep body thermometer
    • Tsuji T. Patient monitoring during and after open heart surgery by an improved deep body thermometer. Med Prog Technol 1987;12:25-38
    • (1987) Med Prog Technol , vol.12 , pp. 25-38
    • Tsuji, T.1
  • 27
    • 0030016299 scopus 로고    scopus 로고
    • Temperatures measured by a deep body thermometer (Coretemp) compared with tissue temperatures measured at various depths using needles placed into the sole of the foot
    • Matsukawa T, Kashimoto S, Ozaki M, Shindo S, Kumazawa T. Temperatures measured by a deep body thermometer (Coretemp) compared with tissue temperatures measured at various depths using needles placed into the sole of the foot. Eur J Anaesthesiol 1996;13:340-5
    • (1996) Eur J Anaesthesiol , vol.13 , pp. 340-345
    • Matsukawa, T.1    Kashimoto, S.2    Ozaki, M.3    Shindo, S.4    Kumazawa, T.5
  • 29
    • 0036948211 scopus 로고    scopus 로고
    • Evaluation of a newly developed monitor of deep body temperature
    • Yamakage M, Iwasaki S, Namiki A. Evaluation of a newly developed monitor of deep body temperature. J Anesth 2002;16:354-7
    • (2002) J Anesth , vol.16 , pp. 354-357
    • Yamakage, M.1    Iwasaki, S.2    Namiki, A.3
  • 30
    • 0038511957 scopus 로고    scopus 로고
    • Correlations between interscapular deep temperature and plasma free fatty acid levels in pregnant women with hyperemesis gravidarum
    • Asakura H, Nakai A, Araki T. Correlations between interscapular deep temperature and plasma free fatty acid levels in pregnant women with hyperemesis gravidarum. Arch Gynecol Obstet 2003;268:35-40
    • (2003) Arch Gynecol Obstet , vol.268 , pp. 35-40
    • Asakura, H.1    Nakai, A.2    Araki, T.3
  • 32
    • 0020645371 scopus 로고
    • Deep body thermometry during general anesthesia
    • Muravchick S. Deep body thermometry during general anesthesia. Anesthesiology 1983;58:271-5
    • (1983) Anesthesiology , vol.58 , pp. 271-275
    • Muravchick, S.1
  • 34
    • 34249108111 scopus 로고    scopus 로고
    • Reliability of temperatures measured at standard monitoring sites as an index of brain temperature during deep hypothermic cardiopulmonary bypass conducted for thoracic aortic reconstruction
    • Akata T, Setoguchi H, Shirozu K, Yoshino J. Reliability of temperatures measured at standard monitoring sites as an index of brain temperature during deep hypothermic cardiopulmonary bypass conducted for thoracic aortic reconstruction. J Thorac Cardiovasc Surg 2007;133:1559-65
    • (2007) J Thorac Cardiovasc Surg , vol.133 , pp. 1559-1565
    • Akata, T.1    Setoguchi, H.2    Shirozu, K.3    Yoshino, J.4
  • 35
    • 0003306801 scopus 로고
    • Rolfe P, ed. Non-invasive Physiological Measurements. London: Academic Press
    • Togawa T. Non-invasive deep body temperature measurement. In: Rolfe P, ed. Non-invasive Physiological Measurements. London: Academic Press, 1979:261-77
    • (1979) Non-invasive Deep Body Temperature Measurement , pp. 261-277
    • Togawa, T.1
  • 36
    • 0021824079 scopus 로고
    • Body temperature measurement
    • Togawa T. Body temperature measurement. Clin Phys Physiol Meas 1985;6:83-108
    • (1985) Clin Phys Physiol Meas , vol.6 , pp. 83-108
    • Togawa, T.1
  • 37
    • 48849099141 scopus 로고    scopus 로고
    • Temperature monitoring and perioperative thermoregulation
    • Sessler DI. Temperature monitoring and perioperative thermoregulation. Anesthesiology 2008;109:318-38
    • (2008) Anesthesiology , vol.109 , pp. 318-338
    • Sessler, D.I.1
  • 38
    • 72449123162 scopus 로고    scopus 로고
    • Development of a new method for the noninvasive measurement of deep body temperature without a heater
    • Kitamura K, Zhu X, Chen W, Nemoto T. Development of a new method for the noninvasive measurement of deep body temperature without a heater. Med Eng Phys 2010;32:1-6
    • (2010) Med Eng Phys , vol.32 , pp. 1-6
    • Kitamura, K.1    Zhu, X.2    Chen, W.3    Nemoto, T.4
  • 39
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999;8:135-60
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 40
    • 0036292261 scopus 로고    scopus 로고
    • Insufficiency in a new temporal-Artery thermometer for adult and pediatric patients
    • Suleman MI, Doufas AG, Akça O, Ducharme M, Sessler DI. Insufficiency in a new temporal-Artery thermometer for adult and pediatric patients. Anesth Analg 2002;95:67-71
    • (2002) Anesth Analg , vol.95 , pp. 67-71
    • Suleman, M.I.1    Doufas, A.G.2    Akça, O.3    Ducharme, M.4    Sessler, D.I.5
  • 41
    • 34748886138 scopus 로고    scopus 로고
    • Temporal artery versus bladder thermometry during perioperative and intensive care unit monitoring
    • Kimberger O, Cohen D, Illievich U, Lenhardt R. Temporal artery versus bladder thermometry during perioperative and intensive care unit monitoring. Anesth Analg 2007;105:1042-7
    • (2007) Anesth Analg , vol.105 , pp. 1042-1047
    • Kimberger, O.1    Cohen, D.2    Illievich, U.3    Lenhardt, R.4
  • 43
    • 0026732708 scopus 로고
    • A critical appraisal of 98.6 degrees f, the upper limit of the normal body temperature, and other legacies of carl reinhold august wunderlich
    • Mackowiak PA, Wasserman SS, Levine MM. A critical appraisal of 98.6 degrees F, the upper limit of the normal body temperature, and other legacies of Carl Reinhold August Wunderlich. JAMA 1992;268:1578-80
    • (1992) JAMA , vol.268 , pp. 1578-1580
    • MacKowiak, P.A.1    Wasserman, S.S.2    Levine, M.M.3
  • 44
    • 34347375489 scopus 로고    scopus 로고
    • Agreement between methods of measurement with multiple observations per individual
    • Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 2007;17:571-82
    • (2007) J Biopharm Stat , vol.17 , pp. 571-582
    • Bland, J.M.1    Altman, D.G.2
  • 45
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989;45:255-68
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.I.1
  • 46
    • 0242711619 scopus 로고    scopus 로고
    • Usefulness of monitoring forehead deep-Tissue temperature as an index of core temperature in adult patients undergoing laparotomies under general anesthesia-investigation in operating rooms with air-movement control system using vertical flow
    • Akata T, Machida Y, Yoshino J, Hirai T, Sato M, Takamatsu J, Takahashi S. [Usefulness of monitoring forehead deep-Tissue temperature as an index of core temperature in adult patients undergoing laparotomies under general anesthesia-investigation in operating rooms with air-movement control system using vertical flow]. Masui 2003;52:1066-73
    • (2003) Masui , vol.52 , pp. 1066-1073
    • Akata, T.1    Machida, Y.2    Yoshino, J.3    Hirai, T.4    Sato, M.5    Takamatsu, J.6    Takahashi, S.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.