-
1
-
-
0030961861
-
Perioperative maintenance of normothermia reduces the incidence of morbid cardiac events A randomized clinical trial
-
Frank SM, Fleisher LA, Breslow MJ, Higgins MS, Olson KF, Kelly S, Beattie C. Perioperative maintenance of normothermia reduces the incidence of morbid cardiac events. A randomized clinical trial. JAMA 1997;277:1127-34
-
(1997)
JAMA
, vol.277
, pp. 1127-1134
-
-
Frank, S.M.1
Fleisher, L.A.2
Breslow, M.J.3
Higgins, M.S.4
Olson, K.F.5
Kelly, S.6
Beattie, C.7
-
2
-
-
0029921767
-
Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization study of wound infection and temperature group
-
Kurz A, Sessler DI, Lenhardt R. Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization. Study of Wound Infection and Temperature Group. N Engl J Med 1996;334:1209-15
-
(1996)
N Engl J Med
, vol.334
, pp. 1209-1215
-
-
Kurz, A.1
Sessler, D.I.2
Lenhardt, R.3
-
3
-
-
0035883865
-
Effects of preoperative warming on the incidence of wound infection after clean surgery: A randomised controlled trial
-
Melling AC, Ali B, Scott EM, Leaper DJ. Effects of preoperative warming on the incidence of wound infection after clean surgery: A randomised controlled trial. Lancet 2001;358:876-80
-
(2001)
Lancet
, vol.358
, pp. 876-880
-
-
Melling, A.C.1
Ali, B.2
Scott, E.M.3
Leaper, D.J.4
-
4
-
-
37549061416
-
The effects of mild perioperative hypothermia on blood loss and transfusion requirement
-
Rajagopalan S, Mascha E, Na J, Sessler DI. The effects of mild perioperative hypothermia on blood loss and transfusion requirement. Anesthesiology 2008;108:71-7
-
(2008)
Anesthesiology
, vol.108
, pp. 71-77
-
-
Rajagopalan, S.1
Mascha, E.2
Na, J.3
Sessler, D.I.4
-
5
-
-
0031469106
-
Mild intraoperative hypothermia prolongs postanesthetic recovery
-
Lenhardt R, Marker E, Goll V, Tschernich H, Kurz A, Sessler DI, Narzt E, Lackner F. Mild intraoperative hypothermia prolongs postanesthetic recovery. Anesthesiology 1997;87:1318-23
-
(1997)
Anesthesiology
, vol.87
, pp. 1318-1323
-
-
Lenhardt, R.1
Marker, E.2
Goll, V.3
Tschernich, H.4
Kurz, A.5
Sessler, D.I.6
Narzt, E.7
Lackner, F.8
-
6
-
-
67650067621
-
Noninvasive temperature monitoring in postanesthesia care units
-
Langham GE, Maheshwari A, Contrera K, You J, Mascha E, Sessler DI. Noninvasive temperature monitoring in postanesthesia care units. Anesthesiology 2009;111:90-6
-
(2009)
Anesthesiology
, vol.111
, pp. 90-96
-
-
Langham, G.E.1
Maheshwari, A.2
Contrera, K.3
You, J.4
Mascha, E.5
Sessler, D.I.6
-
7
-
-
0030889304
-
Influence of thermoregulatory vasomotion and ambient temperature variation on the accuracy of core-Temperature estimates by cutaneous liquidcrystal thermometers
-
Ikeda T, Sessler DI, Marder D, Xiong J. Influence of thermoregulatory vasomotion and ambient temperature variation on the accuracy of core-Temperature estimates by cutaneous liquidcrystal thermometers. Anesthesiology 1997;86:603-12
-
(1997)
Anesthesiology
, vol.86
, pp. 603-612
-
-
Ikeda, T.1
Sessler, D.I.2
Marder, D.3
Xiong, J.4
-
8
-
-
0029998804
-
Thermal response in acute porcine malignant hyperthermia
-
Iaizzo PA, Kehler CH, Zink RS, Belani KG, Sessler DI. Thermal response in acute porcine malignant hyperthermia. Anesth Analg 1996;82:782-9
-
(1996)
Anesth Analg
, vol.82
, pp. 782-789
-
-
Iaizzo, P.A.1
Kehler, C.H.2
Zink, R.S.3
Belani, K.G.4
Sessler, D.I.5
-
9
-
-
0014987164
-
A new technique for monitoring the deep body temperature in man from the intact skin surface
-
Fox RH, Solman AJ. A new technique for monitoring the deep body temperature in man from the intact skin surface. J Physiol 1971;212:8P-10P
-
(1971)
J Physiol
, vol.212
-
-
Fox, R.H.1
Solman, A.J.2
-
10
-
-
0015677269
-
New thermometers for deep tissue temperature
-
Solman AJ, Dalton JC. New thermometers for deep tissue temperature. Biomed Eng 1973;8:432-5
-
(1973)
Biomed Eng
, vol.8
, pp. 432-435
-
-
Solman, A.J.1
Dalton, J.C.2
-
11
-
-
0015547160
-
A new method for monitoring deep body temperature from the skin surface
-
Fox RH, Solman AJ, Isaacs R, Fry AJ, MacDonald IC. A new method for monitoring deep body temperature from the skin surface. Clin Sci 1973;44:81-6
-
(1973)
Clin Sci
, vol.44
, pp. 81-86
-
-
Fox, R.H.1
Solman, A.J.2
Isaacs, R.3
Fry, A.J.4
MacDonald, I.C.5
-
14
-
-
0024040995
-
Improved probe for a deep body thermometer
-
Nemoto T, Togawa T. Improved probe for a deep body thermometer. Med Biol Eng Comput 1988;26:456-9
-
(1988)
Med Biol Eng Comput
, vol.26
, pp. 456-459
-
-
Nemoto, T.1
Togawa, T.2
-
15
-
-
0038261987
-
Deep temperature monitoring using a zero-heat-flow method
-
Yamakage M, Namiki A. Deep temperature monitoring using a zero-heat-flow method. J Anesth 2003;17:108-15
-
(2003)
J Anesth
, vol.17
, pp. 108-115
-
-
Yamakage, M.1
Namiki, A.2
-
16
-
-
0017841193
-
A new method for the transcutaneous measurement of deep body temperature during anaesthesia and intensive care (author's transl)
-
Jost U, Hanf K, Köhler CO, Just OH. [A new method for the transcutaneous measurement of deep body temperature during anaesthesia and intensive care (author's transl)]. Prakt Anaesth 1978;13:144-9
-
(1978)
Prakt Anaesth
, vol.13
, pp. 144-149
-
-
Jost, U.1
Hanf, K.2
Köhler, C.O.3
Just, O.H.4
-
17
-
-
22144462818
-
Confounding factors in the use of the zero-heat-flow method for non-invasive muscle temperature measurement
-
Brajkovic D, Ducharme MB. Confounding factors in the use of the zero-heat-flow method for non-invasive muscle temperature measurement. Eur J Appl Physiol 2005;94:386-91
-
(2005)
Eur J Appl Physiol
, vol.94
, pp. 386-391
-
-
Brajkovic, D.1
Ducharme, M.B.2
-
18
-
-
0034465393
-
A new combined deep-body-Temperature/NIRs probe for noninvasive metabolic measurements on human skeletal muscle
-
Binzoni T, Springett R, Dalton JC, Delpy D. A new combined deep-body-Temperature/NIRs probe for noninvasive metabolic measurements on human skeletal muscle. Adv Exp Med Biol 1999;471:623-9
-
(1999)
Adv Exp Med Biol
, vol.471
, pp. 623-629
-
-
Binzoni, T.1
Springett, R.2
Dalton, J.C.3
Delpy, D.4
-
19
-
-
0023773212
-
A tissue heat transfer model for relating dynamic skin temperature changes to physiological parameters
-
Wilson SB, Spence VA. A tissue heat transfer model for relating dynamic skin temperature changes to physiological parameters. Phys Med Biol 1988;33:895-912
-
(1988)
Phys Med Biol
, vol.33
, pp. 895-912
-
-
Wilson, S.B.1
Spence, V.A.2
-
20
-
-
0030882363
-
Postanesthetic vasoconstriction slows peripheral-To-core transfer of cutaneous heat, thereby isolating the core thermal compartment
-
Plattner O, Ikeda T, Sessler DI, Christensen R, Turakhia M. Postanesthetic vasoconstriction slows peripheral-To-core transfer of cutaneous heat, thereby isolating the core thermal compartment. Anesth Analg 1997;85:899-906
-
(1997)
Anesth Analg
, vol.85
, pp. 899-906
-
-
Plattner, O.1
Ikeda, T.2
Sessler, D.I.3
Christensen, R.4
Turakhia, M.5
-
21
-
-
0019276302
-
Noninvasive determination of core temperature during anesthesia
-
Lees DE, Kim YD, Macnamara TE. Noninvasive determination of core temperature during anesthesia. South Med J 1980;73:1322-4
-
(1980)
South Med J
, vol.73
, pp. 1322-1324
-
-
Lees, D.E.1
Kim, Y.D.2
MacNamara, T.E.3
-
23
-
-
0027359330
-
Deep body temperature during the warming phase of cardiopulmonary bypass
-
Sakuragi T, Mukai M, Dan K. Deep body temperature during the warming phase of cardiopulmonary bypass. Br J Anaesth 1993;71:583-5
-
(1993)
Br J Anaesth
, vol.71
, pp. 583-585
-
-
Sakuragi, T.1
Mukai, M.2
Dan, K.3
-
24
-
-
0015648920
-
A clinical apraisal of transcutaneous deep body temperature
-
Ball SG, Chalmers DM, Morgan AG, Solman AJ, Losowsky MS. A clinical apraisal of transcutaneous deep body temperature. Biomedicine 1973;18:190-4
-
(1973)
Biomedicine
, vol.18
, pp. 190-194
-
-
Ball, S.G.1
Chalmers, D.M.2
Morgan, A.G.3
Solman, A.J.4
Losowsky, M.S.5
-
25
-
-
0023324425
-
Twenty-four hour monitoring of deep body temperature with a novel flexible probe
-
Fukuoka M, Yamori Y, Toyoshima T. Twenty-four hour monitoring of deep body temperature with a novel flexible probe. J Biomed Eng 1987;9:173-6
-
(1987)
J Biomed Eng
, vol.9
, pp. 173-176
-
-
Fukuoka, M.1
Yamori, Y.2
Toyoshima, T.3
-
26
-
-
0023639893
-
Patient monitoring during and after open heart surgery by an improved deep body thermometer
-
Tsuji T. Patient monitoring during and after open heart surgery by an improved deep body thermometer. Med Prog Technol 1987;12:25-38
-
(1987)
Med Prog Technol
, vol.12
, pp. 25-38
-
-
Tsuji, T.1
-
27
-
-
0030016299
-
Temperatures measured by a deep body thermometer (Coretemp) compared with tissue temperatures measured at various depths using needles placed into the sole of the foot
-
Matsukawa T, Kashimoto S, Ozaki M, Shindo S, Kumazawa T. Temperatures measured by a deep body thermometer (Coretemp) compared with tissue temperatures measured at various depths using needles placed into the sole of the foot. Eur J Anaesthesiol 1996;13:340-5
-
(1996)
Eur J Anaesthesiol
, vol.13
, pp. 340-345
-
-
Matsukawa, T.1
Kashimoto, S.2
Ozaki, M.3
Shindo, S.4
Kumazawa, T.5
-
28
-
-
0030615254
-
Comparison of distal oesophageal temperature with 'deep' and tracheal temperatures
-
Matsukawa T, Sessler DI, Ozaki M, Hanagata K, Iwashita H, Kumazawa T. Comparison of distal oesophageal temperature with 'deep' and tracheal temperatures. Can J Anaesth 1997;44:433-8
-
(1997)
Can J Anaesth
, vol.44
, pp. 433-438
-
-
Matsukawa, T.1
Sessler, D.I.2
Ozaki, M.3
Hanagata, K.4
Iwashita, H.5
Kumazawa, T.6
-
29
-
-
0036948211
-
Evaluation of a newly developed monitor of deep body temperature
-
Yamakage M, Iwasaki S, Namiki A. Evaluation of a newly developed monitor of deep body temperature. J Anesth 2002;16:354-7
-
(2002)
J Anesth
, vol.16
, pp. 354-357
-
-
Yamakage, M.1
Iwasaki, S.2
Namiki, A.3
-
30
-
-
0038511957
-
Correlations between interscapular deep temperature and plasma free fatty acid levels in pregnant women with hyperemesis gravidarum
-
Asakura H, Nakai A, Araki T. Correlations between interscapular deep temperature and plasma free fatty acid levels in pregnant women with hyperemesis gravidarum. Arch Gynecol Obstet 2003;268:35-40
-
(2003)
Arch Gynecol Obstet
, vol.268
, pp. 35-40
-
-
Asakura, H.1
Nakai, A.2
Araki, T.3
-
31
-
-
68049137907
-
Accuracy and precision of a novel non-invasive core thermometer
-
Kimberger O, Thell R, Schuh M, Koch J, Sessler DI, Kurz A. Accuracy and precision of a novel non-invasive core thermometer. Br J Anaesth 2009;103:226-31
-
(2009)
Br J Anaesth
, vol.103
, pp. 226-231
-
-
Kimberger, O.1
Thell, R.2
Schuh, M.3
Koch, J.4
Sessler, D.I.5
Kurz, A.6
-
32
-
-
0020645371
-
Deep body thermometry during general anesthesia
-
Muravchick S. Deep body thermometry during general anesthesia. Anesthesiology 1983;58:271-5
-
(1983)
Anesthesiology
, vol.58
, pp. 271-275
-
-
Muravchick, S.1
-
33
-
-
0033751668
-
Deep-forehead temperature correlates well with blood temperature
-
Harioka T, Matsukawa T, Ozaki M, Nomura K, Sone T, Kakuyama M, Toda H. 'Deep-forehead' temperature correlates well with blood temperature. Can J Anaesth 2000;47:980-3
-
(2000)
Can J Anaesth
, vol.47
, pp. 980-983
-
-
Harioka, T.1
Matsukawa, T.2
Ozaki, M.3
Nomura, K.4
Sone, T.5
Kakuyama, M.6
Toda, H.7
-
34
-
-
34249108111
-
Reliability of temperatures measured at standard monitoring sites as an index of brain temperature during deep hypothermic cardiopulmonary bypass conducted for thoracic aortic reconstruction
-
Akata T, Setoguchi H, Shirozu K, Yoshino J. Reliability of temperatures measured at standard monitoring sites as an index of brain temperature during deep hypothermic cardiopulmonary bypass conducted for thoracic aortic reconstruction. J Thorac Cardiovasc Surg 2007;133:1559-65
-
(2007)
J Thorac Cardiovasc Surg
, vol.133
, pp. 1559-1565
-
-
Akata, T.1
Setoguchi, H.2
Shirozu, K.3
Yoshino, J.4
-
35
-
-
0003306801
-
-
Rolfe P, ed. Non-invasive Physiological Measurements. London: Academic Press
-
Togawa T. Non-invasive deep body temperature measurement. In: Rolfe P, ed. Non-invasive Physiological Measurements. London: Academic Press, 1979:261-77
-
(1979)
Non-invasive Deep Body Temperature Measurement
, pp. 261-277
-
-
Togawa, T.1
-
36
-
-
0021824079
-
Body temperature measurement
-
Togawa T. Body temperature measurement. Clin Phys Physiol Meas 1985;6:83-108
-
(1985)
Clin Phys Physiol Meas
, vol.6
, pp. 83-108
-
-
Togawa, T.1
-
37
-
-
48849099141
-
Temperature monitoring and perioperative thermoregulation
-
Sessler DI. Temperature monitoring and perioperative thermoregulation. Anesthesiology 2008;109:318-38
-
(2008)
Anesthesiology
, vol.109
, pp. 318-338
-
-
Sessler, D.I.1
-
38
-
-
72449123162
-
Development of a new method for the noninvasive measurement of deep body temperature without a heater
-
Kitamura K, Zhu X, Chen W, Nemoto T. Development of a new method for the noninvasive measurement of deep body temperature without a heater. Med Eng Phys 2010;32:1-6
-
(2010)
Med Eng Phys
, vol.32
, pp. 1-6
-
-
Kitamura, K.1
Zhu, X.2
Chen, W.3
Nemoto, T.4
-
39
-
-
0032884749
-
Measuring agreement in method comparison studies
-
Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999;8:135-60
-
(1999)
Stat Methods Med Res
, vol.8
, pp. 135-160
-
-
Bland, J.M.1
Altman, D.G.2
-
40
-
-
0036292261
-
Insufficiency in a new temporal-Artery thermometer for adult and pediatric patients
-
Suleman MI, Doufas AG, Akça O, Ducharme M, Sessler DI. Insufficiency in a new temporal-Artery thermometer for adult and pediatric patients. Anesth Analg 2002;95:67-71
-
(2002)
Anesth Analg
, vol.95
, pp. 67-71
-
-
Suleman, M.I.1
Doufas, A.G.2
Akça, O.3
Ducharme, M.4
Sessler, D.I.5
-
41
-
-
34748886138
-
Temporal artery versus bladder thermometry during perioperative and intensive care unit monitoring
-
Kimberger O, Cohen D, Illievich U, Lenhardt R. Temporal artery versus bladder thermometry during perioperative and intensive care unit monitoring. Anesth Analg 2007;105:1042-7
-
(2007)
Anesth Analg
, vol.105
, pp. 1042-1047
-
-
Kimberger, O.1
Cohen, D.2
Illievich, U.3
Lenhardt, R.4
-
42
-
-
33845937103
-
Tympanic temperature measurements: Are they reliable in the critically ill? A clinical study of measures of agreement
-
Moran JL, Peter JV, Solomon PJ, Grealy B, Smith T, Ashforth W, Wake M, Peake SL, Peisach AR. Tympanic temperature measurements: Are they reliable in the critically ill? A clinical study of measures of agreement. Crit Care Med 2007;35:155-64
-
(2007)
Crit Care Med
, vol.35
, pp. 155-164
-
-
Moran, J.L.1
Peter, J.V.2
Solomon, P.J.3
Grealy, B.4
Smith, T.5
Ashforth, W.6
Wake, M.7
Peake, S.L.8
Peisach, A.R.9
-
43
-
-
0026732708
-
A critical appraisal of 98.6 degrees f, the upper limit of the normal body temperature, and other legacies of carl reinhold august wunderlich
-
Mackowiak PA, Wasserman SS, Levine MM. A critical appraisal of 98.6 degrees F, the upper limit of the normal body temperature, and other legacies of Carl Reinhold August Wunderlich. JAMA 1992;268:1578-80
-
(1992)
JAMA
, vol.268
, pp. 1578-1580
-
-
MacKowiak, P.A.1
Wasserman, S.S.2
Levine, M.M.3
-
44
-
-
34347375489
-
Agreement between methods of measurement with multiple observations per individual
-
Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 2007;17:571-82
-
(2007)
J Biopharm Stat
, vol.17
, pp. 571-582
-
-
Bland, J.M.1
Altman, D.G.2
-
45
-
-
0024521543
-
A concordance correlation coefficient to evaluate reproducibility
-
Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989;45:255-68
-
(1989)
Biometrics
, vol.45
, pp. 255-268
-
-
Lin, L.I.1
-
46
-
-
0242711619
-
Usefulness of monitoring forehead deep-Tissue temperature as an index of core temperature in adult patients undergoing laparotomies under general anesthesia-investigation in operating rooms with air-movement control system using vertical flow
-
Akata T, Machida Y, Yoshino J, Hirai T, Sato M, Takamatsu J, Takahashi S. [Usefulness of monitoring forehead deep-Tissue temperature as an index of core temperature in adult patients undergoing laparotomies under general anesthesia-investigation in operating rooms with air-movement control system using vertical flow]. Masui 2003;52:1066-73
-
(2003)
Masui
, vol.52
, pp. 1066-1073
-
-
Akata, T.1
Machida, Y.2
Yoshino, J.3
Hirai, T.4
Sato, M.5
Takamatsu, J.6
Takahashi, S.7
-
47
-
-
0028924352
-
Thermoregulatory vasoconstriction impairs active core cooling
-
Kurz A, Sessler DI, Birnbauer F, Illievich UM, Spiss CK. Thermoregulatory vasoconstriction impairs active core cooling. Anesthesiology 1995;82:870-6.
-
(1995)
Anesthesiology
, vol.82
, pp. 870-876
-
-
Kurz, A.1
Sessler, D.I.2
Birnbauer, F.3
Illievich, U.M.4
Spiss, C.K.5
|