Volumn 103, Issue 2, 2009, Pages 226-231

Accuracy and precision of a novel non-invasive core thermometer

Author keywords

Monitoring, temperature; Temperature, body; Temperature, monitoring

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; CORE TEMPERATURE; DIAGNOSTIC VALUE; FEMALE; HUMAN; HYPOTHERMIA; INTENSIVE CARE; MAJOR CLINICAL STUDY; MALE; PERIOPERATIVE PERIOD; PRIORITY JOURNAL; REGIONAL ANESTHESIA; SENSITIVITY AND SPECIFICITY; SENSOR; TEMPERATURE MEASUREMENT; THERMOMETER;

EID: 68049137907     PISSN: 00070912     EISSN: 14716771     Source Type: Journal    
DOI: 10.1093/bja/aep134     Document Type: Article
Times cited : (91)

References (30)
  • 1
    • 0029921767 scopus 로고    scopus 로고
    • Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization
    • Study of Wound Infection and Temperature Group
    • Kurz A, Sessler DI, Lenhardt R. Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization. Study of Wound Infection and Temperature Group. N Engl J Med 1996; 334: 1209-1215
    • (1996) N Engl J Med , vol.334 , pp. 1209-1215
    • Kurz, A.1    Sessler, D.I.2    Lenhardt, R.3
  • 2
    • 0030031773 scopus 로고    scopus 로고
    • Mild hypothermia increases blood loss and transfusion requirements during total hip arthroplasty
    • DOI 10.1016/S0140-6736(96)90466-3
    • Schmied H, Kurz A, Sessler DI, Kozek S, Reiter A. Mild hypothermia increases blood loss and transfusion requirements during total hip arthroplasty. Lancet 1996; 347: 289-292 (Pubitemid 26041040)
    • (1996) Lancet , vol.347 , Issue.8997 , pp. 289-292
    • Schmied, H.1    Kurz, A.2    Sessler, D.I.3    Kozek, S.4    Reiter, A.5
  • 4
    • 48949119301 scopus 로고    scopus 로고
    • Brain hyperthermia after traumatic brain injury does not reduce brain oxygen
    • Spiotta AM, Stiefel MF, Heuer GG, et al. Brain hyperthermia after traumatic brain injury does not reduce brain oxygen. Neurosurgery 2008; 62: 864-872
    • (2008) Neurosurgery , vol.62 , pp. 864-872
    • Spiotta, A.M.1    Stiefel, M.F.2    Heuer, G.G.3
  • 5
    • 0030752162 scopus 로고    scopus 로고
    • A rapid increase in foot tissue temperature predicts cardiovascular collapse during anaphylactic and anaphylactoid reactions
    • DOI 10.1097/00000542-199709000-00016
    • Kotani N, Kushikata T, Matsukawa T, et al. A rapid increase in foot tissue temperature predicts cardiovascular collapse during anaphylactic and anaphylactoid reactions. Anesthesiology 1997; 87: 559-568 (Pubitemid 27433005)
    • (1997) Anesthesiology , vol.87 , Issue.3 , pp. 559-568
    • Kotani, N.1    Kushikata, T.2    Matsukawa, T.3    Sessler, D.I.4    Muraoka, M.5    Hashimoto, H.6    Ishihara, H.7    Matsuki, A.8
  • 7
    • 0032938896 scopus 로고    scopus 로고
    • Temperature monitoring practices during regional anesthesia
    • DOI 10.1097/00000539-199902000-00028
    • Frank SM, Nguyen JM, Garcia CM, Barnes RA. Temperature monitoring practices during regional anesthesia. Anesth Analg 1999; 88: 373-377 (Pubitemid 29070201)
    • (1999) Anesthesia and Analgesia , vol.88 , Issue.2 , pp. 373-377
    • Frank, S.M.1    Nguyen, J.M.2    Garcia, C.M.3    Barnes, R.A.4
  • 8
    • 56449127460 scopus 로고    scopus 로고
    • Perioperative hypothermia (inadvertent): The management of inadvertent perioperative hypothermia in adults
    • NICE National Institute for Health and Clinical Excellence
    • NICE. Perioperative hypothermia (inadvertent): the management of inadvertent perioperative hypothermia in adults. NICE Clinical Guideline 29. National Institute for Health and Clinical Excellence, 2008
    • (2008) NICE Clinical Guideline 29
  • 11
    • 0029893030 scopus 로고    scopus 로고
    • Reduction in the shivering threshold is proportional to spinal block height
    • Leslie K, Sessler DI. Reduction in the shivering threshold is proportional to spinal block height. Anesthesiology 1996; 84: 1327-1331
    • (1996) Anesthesiology , vol.84 , pp. 1327-1331
    • Leslie, K.1    Sessler, D.I.2
  • 12
    • 0041968520 scopus 로고    scopus 로고
    • Detecting fever in young infants: Reliability of perceived, pacifier, and temporal artery temperatures in infants younger than 3 months of age
    • DOI 10.1097/01.pec.0000086231.54586.15
    • Callanan D. Detecting fever in young infants: reliability of perceived, pacifier, and temporal artery temperatures in infants younger than 3 months of age. Pediatr Emerg Care 2003; 19: 240-243 (Pubitemid 37013173)
    • (2003) Pediatric Emergency Care , vol.19 , Issue.4 , pp. 240-243
    • Callanan, D.1
  • 13
    • 0021247499 scopus 로고
    • Axillary temperature as a screening test for fever in children
    • Kresch MJ. Axillary temperature as a screening test for fever in children. J Pediatr 1984; 104: 596-599
    • (1984) J Pediatr , vol.104 , pp. 596-599
    • Kresch, M.J.1
  • 15
    • 0025977593 scopus 로고
    • Comparison of rectal, axillary, and tympanic membrane temperatures in infants and young children
    • Muma BK, Treloar DJ, Wurmlinger K, Peterson E, Vitae A. Comparison of rectal, axillary, and tympanic membrane temperatures in infants and young children. Ann Emerg Med 1991; 20: 41-44
    • (1991) Ann Emerg Med , vol.20 , pp. 41-44
    • Muma, B.K.1    Treloar, D.J.2    Wurmlinger, K.3    Peterson, E.4    Vitae, A.5
  • 16
    • 0033111525 scopus 로고    scopus 로고
    • A comparison of the use of tympanic, axillary, and rectal thermometers in infants
    • Wilshaw R, Beckstrand R, Waid D, Schaalje GB. A comparison of the use of tympanic, axillary, and rectal thermometers in infants. J Pediatr Nurs 1999; 14: 88-93
    • (1999) J Pediatr Nurs , vol.14 , pp. 88-93
    • Wilshaw, R.1    Beckstrand, R.2    Waid, D.3    Schaalje, G.B.4
  • 17
    • 0034108727 scopus 로고    scopus 로고
    • The accuracy and precision of body temperature monitoring methods during regional and general anesthesia
    • Cattaneo CG, Frank SM, Hesel TW, El-Rahmany HK, Kim LJ, Tran KM. The accuracy and precision of body temperature monitoring methods during regional and general anesthesia. Anesth Analg 2000; 90: 938-945
    • (2000) Anesth Analg , vol.90 , pp. 938-945
    • Cattaneo, C.G.1    Frank, S.M.2    Hesel, T.W.3    El-Rahmany, H.K.4    Kim, L.J.5    Tran, K.M.6
  • 18
    • 0036842372 scopus 로고    scopus 로고
    • Limited accuracy and reliability of infrared axillary and aural thermometers in a pediatric outpatient population
    • DOI 10.1067/mpd.2002.127664
    • Jean-Mary MB, Dicanzio J, Shaw J, Bernstein HH. Limited accuracy and reliability of infrared axillary and aural thermometers in a pediatric outpatient population. J Pediatr 2002; 141: 671-676 (Pubitemid 35292766)
    • (2002) Journal of Pediatrics , vol.141 , Issue.5 , pp. 671-676
    • Jean-Mary, M.B.1    Dicanzio, J.2    Shaw, J.3    Bernstein, H.H.4
  • 19
    • 0036292261 scopus 로고    scopus 로고
    • Insufficiency in a new temporal-artery thermometer for adult and pediatric patients
    • Suleman MI, Doufas AG, Akca O, Ducharme M, Sessler DI. Insufficiency in a new temporal-artery thermometer for adult and pediatric patients. Anesth Analg 2002; 95: 67-71
    • (2002) Anesth Analg , vol.95 , pp. 67-71
    • Suleman, M.I.1    Doufas, A.G.2    Akca, O.3    Ducharme, M.4    Sessler, D.I.5
  • 20
    • 34748886138 scopus 로고    scopus 로고
    • Temporal artery versus bladder thermometry during perioperative and intensive care unit monitoring
    • DOI 10.1213/01.ane.0000281927.88935.e0, PII 0000053920071000000024
    • Kimberger O, Cohen D, Illievich U, Lenhardt R. Temporal artery versus bladder thermometry during perioperative and intensive care unit monitoring. Anesth Analg 2007; 105: 1042-1047 (Pubitemid 47479319)
    • (2007) Anesthesia and Analgesia , vol.105 , Issue.4 , pp. 1042-1047
    • Kimberger, O.1    Cohen, D.2    Illievich, U.3    Lenhardt, R.4
  • 22
    • 0030889304 scopus 로고    scopus 로고
    • Influence of thermoregulatory vasomotion and ambient temperature variation on the accuracy of core-temperature estimates by cutaneous liquid- Crystal thermometers
    • DOI 10.1097/00000542-199703000-00012
    • Ikeda T, Sessler DI, Marder D, Xiong J. Influence of thermoregulatory vasomotion and ambient temperature variation on the accuracy of core-temperature estimates by cutaneous liquid-crystal thermometers. Anesthesiology 1997; 86: 603-612 (Pubitemid 27118343)
    • (1997) Anesthesiology , vol.86 , Issue.3 , pp. 603-612
    • Ikeda, T.1    Sessler, D.I.2    Marder, D.3    Xiong, J.4
  • 23
    • 0028121093 scopus 로고
    • Clinical evaluation of liquid crystal skin thermometers
    • MacKenzie R, Asbury AJ. Clinical evaluation of liquid crystal skin thermometers. Br J Anaesth 1994; 72: 246-249 (Pubitemid 24054355)
    • (1994) British Journal of Anaesthesia , vol.72 , Issue.2 , pp. 246-249
    • MacKenzie, R.1    Asbury, A.J.2
  • 24
    • 33845937103 scopus 로고    scopus 로고
    • Tympanic temperature measurements: Are they reliable in the critically ill? a clinical study of measures of agreement
    • Moran JL, Peter JV, Solomon PJ, et al. Tympanic temperature measurements: are they reliable in the critically ill? A clinical study of measures of agreement. Crit Care Med 2007; 35: 155-164
    • (2007) Crit Care Med , vol.35 , pp. 155-164
    • Moran, J.L.1    Peter, J.V.2    Solomon, P.J.3
  • 25
    • 0026356816 scopus 로고
    • Isoflurane anesthesia and circadian temperature cycles in humans
    • Sessler DI, Lee KA, McGuire J. Isoflurane anesthesia and circadian temperature cycles in humans. Anesthesiology 1991; 75: 985-989
    • (1991) Anesthesiology , vol.75 , pp. 985-989
    • Sessler, D.I.1    Lee, K.A.2    McGuire, J.3
  • 27
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 28
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989; 45: 255-268
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.I.1
  • 29
    • 0014987164 scopus 로고
    • A new technique for monitoring the deep body temperature in man from the intact skin surface
    • Fox RH, Solman AJ. A new technique for monitoring the deep body temperature in man from the intact skin surface. J Physiol 1971; 212: 8-10
    • (1971) J Physiol , vol.212 , pp. 8-10
    • Fox, R.H.1    Solman, A.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.