메뉴 건너뛰기




Volumn 117, Issue 4, 2013, Pages 813-823

Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADULT; ARTERIAL OXYGEN SATURATION; ARTERIAL PRESSURE; ARTICLE; BLOOD OXYGEN TENSION; BLOOD OXYGENATION; BLOOD SAMPLING; BRAIN BLOOD FLOW; CEREBRAL OXIMETER; CEREBRAL OXIMETRY; FEMALE; FOOD AND DRUG ADMINISTRATION; HEMOGLOBIN BLOOD LEVEL; HUMAN; HYPOXIA; MALE; NORMAL HUMAN; OXIMETER; OXIMETRY; OXYGEN SATURATION; PERFORMANCE; PRESSURE; PRIORITY JOURNAL; PULSE OXIMETER; RADIAL ARTERY; REBREATHING; SEX DIFFERENCE; SKIN COLOR; SKIN PIGMENTATION; STEADY STATE; VENOUS BLOOD;

EID: 84885019374     PISSN: 00032999     EISSN: 15267598     Source Type: Journal    
DOI: 10.1213/ANE.0b013e318297d763     Document Type: Article
Times cited : (180)

References (25)
  • 1
    • 0039390359 scopus 로고
    • Spectrophotometry of intracellular respiratory pigments
    • Chance B. Spectrophotometry of intracellular respiratory pigments. Science 1954;120:767-75
    • (1954) Science , vol.120 , pp. 767-775
    • Chance, B.1
  • 2
    • 0017571334 scopus 로고
    • Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters
    • Jöbsis FF. Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science 1977;198:1264-7 (Pubitemid 8308546)
    • (1977) Science , vol.198 , Issue.4323 , pp. 1264-1267
    • Jobsis, F.F.1
  • 3
    • 82255167209 scopus 로고    scopus 로고
    • Haemoglobin oxygen saturation as a biomarker: The problem and a solution
    • Boas DA, Franceschini MA. Haemoglobin oxygen saturation as a biomarker: the problem and a solution. Philos Trans A Math Phys Eng Sci 2011;369:4407-24
    • (2011) Philos Trans A Math Phys Eng Sci , vol.369 , pp. 4407-4424
    • Boas, D.A.1    Franceschini, M.A.2
  • 5
    • 5644257026 scopus 로고    scopus 로고
    • Cerebral oxygen desaturation is associated with early postoperative neuropsychological dysfunction in patients undergoing cardiac surgery
    • DOI 10.1053/j.jvca.2004.07.007, PII S1053077004001570
    • Yao FS, Tseng CC, Ho CY, Levin SK, Illner P. Cerebral oxygen desaturation is associated with early postoperative neuropsychological dysfunction in patients undergoing cardiac surgery. J Cardiothorac Vasc Anesth 2004;18:552-8 (Pubitemid 39369952)
    • (2004) Journal of Cardiothoracic and Vascular Anesthesia , vol.18 , Issue.5 , pp. 552-558
    • Yao, F.-S.F.1    Tseng, C.-C.A.2    Ho, C.-Y.A.3    Levin, S.K.4    Illner, P.5
  • 6
    • 3342916811 scopus 로고    scopus 로고
    • Optimizing intraoperative cerebral oxygen delivery using noninvasive cerebral oximetry decreases the incidence of stroke for cardiac surgical patients
    • Goldman S, Sutter F, Ferdinand F, Trace C. Optimizing intraoperative cerebral oxygen delivery using noninvasive cerebral oximetry decreases the incidence of stroke for cardiac surgical patients. Heart Surg Forum 2004;7:E376-81
    • (2004) Heart Surg Forum , vol.7
    • Goldman, S.1    Sutter, F.2    Ferdinand, F.3    Trace, C.4
  • 11
    • 70449715508 scopus 로고    scopus 로고
    • The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention
    • Pennekamp CW, Bots ML, Kappelle LJ, Moll FL, de Borst GJ. The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention. A review. Eur J Vasc Endovasc Surg 2009;38:539-45
    • (2009) A Review. Eur J Vasc Endovasc Surg , vol.38 , pp. 539-545
    • Pennekamp, C.W.1    Bots, M.L.2    Kappelle, L.J.3    Moll, F.L.4    De Borst, G.J.5
  • 12
    • 0029829966 scopus 로고    scopus 로고
    • Cerebral oxygenation monitoring by near-infrared spectroscopy is not clinically useful in patients with severe closed-head injury: A comparison with jugular venous bulb oximetry
    • Lewis SB, Myburgh JA, Thornton EL, Reilly PL. Cerebral oxygenation monitoring by near-infrared spectroscopy is not clinically useful in patients with severe closed-head injury: a comparison with jugular venous bulb oximetry. Crit Care Med 1996;24:1334-8 (Pubitemid 26262407)
    • (1996) Critical Care Medicine , vol.24 , Issue.8 , pp. 1334-1338
    • Lewis, S.B.1    Myburgh, J.A.2    Thornton, E.L.3    Reilly, P.L.4
  • 13
    • 77952003542 scopus 로고    scopus 로고
    • Near infrared spectroscopy in children at high risk of low perfusion
    • Mittnacht AJ. Near infrared spectroscopy in children at high risk of low perfusion. Curr Opin Anaesthesiol 2010;23:342-7
    • (2010) Curr Opin Anaesthesiol , vol.23 , pp. 342-347
    • Mittnacht, A.J.1
  • 14
    • 84859111411 scopus 로고    scopus 로고
    • Impact of extracranial contamination on regional cerebral oxygen saturation: A comparison of three cerebral oximetry technologies
    • Davie SN, Grocott HP. Impact of extracranial contamination on regional cerebral oxygen saturation: a comparison of three cerebral oximetry technologies. Anesthesiology 2012;116:834-40
    • (2012) Anesthesiology , vol.116 , pp. 834-840
    • Davie, S.N.1    Grocott, H.P.2
  • 15
    • 84864279167 scopus 로고    scopus 로고
    • Cutaneous vasoconstriction affects near-infrared spectroscopy determined cerebral oxygen saturation during administration of norepinephrine
    • Sørensen H, Secher NH, Siebenmann C, Nielsen HB, Kohl-Bareis M, Lundby C, Rasmussen P. Cutaneous vasoconstriction affects near-infrared spectroscopy determined cerebral oxygen saturation during administration of norepinephrine. Anesthesiology 2012;117:263-70
    • (2012) Anesthesiology , vol.117 , pp. 263-270
    • Sørensen, H.1    Secher, N.H.2    Siebenmann, C.3    Nielsen, H.B.4    Kohl-Bareis, M.5    Lundby, C.6    Rasmussen, P.7
  • 17
    • 44349104866 scopus 로고    scopus 로고
    • Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: The effects of oximeter probe type and gender
    • Feiner JR, Severinghaus JW, Bickler PE. Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: the effects of oximeter probe type and gender. Anesth Analg 2007;105:S18-23
    • (2007) Anesth Analg , vol.105
    • Feiner, J.R.1    Severinghaus, J.W.2    Bickler, P.E.3
  • 18
    • 0031002310 scopus 로고    scopus 로고
    • The rate of blood withdrawal affects the accuracy of jugular venous bulb Oxygen saturation measurements
    • Matta BF, Lam AM. The rate of blood withdrawal affects the accuracy of jugular venous bulb. Oxygen saturation measurements. Anesthesiology 1997;86:806-8
    • (1997) Anesthesiology , vol.86 , pp. 806-808
    • Matta, B.F.1    Lam, A.M.2
  • 19
    • 34347375489 scopus 로고    scopus 로고
    • Agreement between methods of measurement with multiple observations per individual
    • DOI 10.1080/10543400701329422, PII 780214319
    • Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 2007;17:571-82 (Pubitemid 47027010)
    • (2007) Journal of Biopharmaceutical Statistics , vol.17 , Issue.4 , pp. 571-582
    • Bland, J.M.1    Altman, D.G.2
  • 20
    • 16244406223 scopus 로고    scopus 로고
    • Effects of skin pigmentation on pulse oximeter accuracy at low saturation
    • DOI 10.1097/00000542-200504000-00004
    • Bickler PE, Feiner JR, Severinghaus JW. Effects of skin pigmentation on pulse oximeter accuracy at low saturation. Anesthesiology 2005;102:715-9 (Pubitemid 40462849)
    • (2005) Anesthesiology , vol.102 , Issue.4 , pp. 715-719
    • Bickler, P.E.1    Feiner, J.R.2    Severinghaus, J.W.3
  • 21
    • 0031973127 scopus 로고    scopus 로고
    • Accuracy of a cerebral oximeter in healthy volunteers under conditions of isocapnic hypoxia
    • DOI 10.1097/00000542-199801000-00011
    • Henson LC, Calalang C, Temp JA, Ward DS. Accuracy of a cerebral oximeter in healthy volunteers under conditions of isocapnic hypoxia. Anesthesiology 1998;88:58-65 (Pubitemid 28053254)
    • (1998) Anesthesiology , vol.88 , Issue.1 , pp. 58-65
    • Henson, L.C.1    Temp, J.A.2    Ward, D.S.3
  • 22
    • 19744379569 scopus 로고    scopus 로고
    • Changes in the arterial fraction of human cerebral blood volume during hypercapnia and hypocapnia measured by positron emission tomography
    • DOI 10.1038/sj.jcbfm.9600076
    • Ito H, Ibaraki M, Kanno I, Fukuda H, Miura S. Changes in the arterial fraction of human cerebral blood volume during hypercapnia and hypocapnia measured by positron emission tomography. J Cereb Blood Flow Metab 2005;25:852-7 (Pubitemid 40905612)
    • (2005) Journal of Cerebral Blood Flow and Metabolism , vol.25 , Issue.7 , pp. 852-857
    • Ito, H.1    Ibaraki, M.2    Kanno, I.3    Fukuda, H.4    Miura, S.5
  • 23
    • 19744367632 scopus 로고    scopus 로고
    • Human cerebral circulation: Positron emission tomography studies
    • Ito H, Kanno I, Fukuda H. Human cerebral circulation: positron emission tomography studies. Ann Nucl Med 2005;19:65-74 (Pubitemid 40745687)
    • (2005) Annals of Nuclear Medicine , vol.19 , Issue.2 , pp. 65-74
    • Ito, H.1    Kanno, I.2    Fukuda, H.3
  • 25
    • 84856281460 scopus 로고    scopus 로고
    • Non-invasive haemoglobin measurement in patients undergoing elective Caesarean section
    • Butwick A, Hilton G, Carvalho B. Non-invasive haemoglobin measurement in patients undergoing elective Caesarean section. Br J Anaesth 2012;108:271-7
    • (2012) Br J Anaesth , vol.108 , pp. 271-277
    • Butwick, A.1    Hilton, G.2    Carvalho, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.