메뉴 건너뛰기




Volumn 33, Issue 2, 2012, Pages 573-583

Virtual monochromatic spectral imaging with fast kilovoltage switching: Reduction of metal artifacts at CT

Author keywords

[No Author keywords available]

Indexed keywords


EID: 84875147000     PISSN: 02715333     EISSN: 15271323     Source Type: Journal    
DOI: 10.1148/rg.332125124     Document Type: Article
Times cited : (187)

References (13)
  • 1
    • 68249083055 scopus 로고    scopus 로고
    • Metal artifact reduction image reconstruction algorithm for CT of implanted metal orthopedic devices: A work in progress
    • Liu PT, Pavlicek WP, Peter MB, Spangehl MJ, Roberts CC, Paden RG. Metal artifact reduction image reconstruction algorithm for CT of implanted metal orthopedic devices: a work in progress. Skeletal Radiol 2009;38(8):797-802.
    • (2009) Skeletal Radiol , vol.38 , Issue.8 , pp. 797-802
    • Liu, P.T.1    Pavlicek, W.P.2    Peter, M.B.3    Spangehl, M.J.4    Roberts, C.C.5    Paden, R.G.6
  • 2
    • 19744369868 scopus 로고    scopus 로고
    • Artifacts in CT: Recognition and avoidance
    • Barrett JF, Keat N. Artifacts in CT: recognition and avoidance. RadioGraphics 2004;24(6):1679-1691.
    • (2004) RadioGraphics , vol.24 , Issue.6 , pp. 1679-1691
    • Barrett, J.F.1    Keat, N.2
  • 3
    • 34249857538 scopus 로고    scopus 로고
    • Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multidetector CT
    • Lee MJ, Kim S, Lee SA, et al. Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multidetector CT. RadioGraphics 2007;27(3):791-803.
    • (2007) RadioGraphics , vol.27 , Issue.3 , pp. 791-803
    • Lee, M.J.1    Kim, S.2    Lee, S.A.3
  • 4
    • 79959376217 scopus 로고    scopus 로고
    • Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    • Bamberg F, Dierks A, Nikolaou K, Reiser MF, Becker CR, Johnson TR. Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation. Eur Radiol 2011;21(7): 1424-1429.
    • (2011) Eur Radiol , vol.21 , Issue.7 , pp. 1424-1429
    • Bamberg, F.1    Dierks, A.2    Nikolaou, K.3    Reiser, M.F.4    Becker, C.R.5    Johnson, T.R.6
  • 5
    • 79953011586 scopus 로고    scopus 로고
    • Virtual monochromatic spectral imaging with fast kilovoltage switching: Improved image quality as compared with that obtained with conventional 120-kVp CT
    • Matsumoto K, Jinzaki M, Tanami Y, Ueno A, Yamada M, Kuribayashi S. Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT. Radiology 2011;259(1):257-262.
    • (2011) Radiology , vol.259 , Issue.1 , pp. 257-262
    • Matsumoto, K.1    Jinzaki, M.2    Tanami, Y.3    Ueno, A.4    Yamada, M.5    Kuribayashi, S.6
  • 6
    • 79960509701 scopus 로고    scopus 로고
    • Dual-energy (spectral) CT: Applications in abdominal imaging
    • discussion 1047-1050
    • Silva AC, Morse BG, Hara AK, Paden RG, Hongo N, Pavlicek W. Dual-energy (spectral) CT: applications in abdominal imaging. RadioGraphics 2011;31 (4):1031-1046; discussion 1047-1050.
    • (2011) RadioGraphics , vol.31 , Issue.4 , pp. 1031-1046
    • Silva, A.C.1    Morse, B.G.2    Hara, A.K.3    Paden, R.G.4    Hongo, N.5    Pavlicek, W.6
  • 7
    • 84858124994 scopus 로고    scopus 로고
    • Dual-energy CT with single-and dual-source scanners: Current applications in evaluating the genitourinary tract
    • Kaza RK, Platt JF, Cohan RH, Caoili EM, Al-Hawary MM, Wasnik A. Dual-energy CT with single-and dual-source scanners: current applications in evaluating the genitourinary tract. RadioGraphics 2012;32(2):353-369.
    • (2012) RadioGraphics , vol.32 , Issue.2 , pp. 353-369
    • Kaza, R.K.1    Platt, J.F.2    Cohan, R.H.3    Caoili, E.M.4    Al-Hawary, M.M.5    Wasnik, A.6
  • 9
    • 84862489319 scopus 로고    scopus 로고
    • Spectral CT with metal artifacts reduction software for improvement of tumor visibility in the vicinity of gold fiducial markers
    • Brook OR, Gourtsoyianni S, Brook A, Mahadevan A, Wilcox C, Raptopoulos V. Spectral CT with metal artifacts reduction software for improvement of tumor visibility in the vicinity of gold fiducial markers. Radiology 2012;263(3):696-705.
    • (2012) Radiology , vol.263 , Issue.3 , pp. 696-705
    • Brook, O.R.1    Gourtsoyianni, S.2    Brook, A.3    Mahadevan, A.4    Wilcox, C.5    Raptopoulos, V.6
  • 10
    • 84862816752 scopus 로고    scopus 로고
    • Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software
    • Lee YH, Park KK, Song HT, Kim S, Suh JS. Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software. Eur Radiol 2012;22(6):1331-1340.
    • (2012) Eur Radiol , vol.22 , Issue.6 , pp. 1331-1340
    • Lee, Y.H.1    Park, K.K.2    Song, H.T.3    Kim, S.4    Suh, J.S.5
  • 12
    • 79959563295 scopus 로고    scopus 로고
    • Quantification of head and body CTDI(VOL) of dual-energy x-ray CT with fast-kVp switching
    • Li B, Yadava G, Hsieh J. Quantification of head and body CTDI(VOL) of dual-energy x-ray CT with fast-kVp switching. Med Phys 2011;38(5): 2595-2601.
    • (2011) Med Phys , vol.38 , Issue.5 , pp. 2595-2601
    • Li, B.1    Yadava, G.2    Hsieh, J.3
  • 13
    • 79952149962 scopus 로고    scopus 로고
    • Objective characterization of GE discovery CT750 HD scanner: Gemstone spectral imaging mode
    • Zhang D, Li X, Liu B. Objective characterization of GE discovery CT750 HD scanner: gemstone spectral imaging mode. Med Phys 2011;38(3): 1178-1188.
    • (2011) Med Phys , vol.38 , Issue.3 , pp. 1178-1188
    • Zhang, D.1    Li, X.2    Liu, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.