-
1
-
-
0029866646
-
The galvanization of biology: A growing appreciation for the roles of zinc
-
J.M. Berg, and Y. Shi The galvanization of biology: a growing appreciation for the roles of zinc Science 271 1996 1081 1085 (Pubitemid 26075222)
-
(1996)
Science
, vol.271
, Issue.5252
, pp. 1081-1085
-
-
Berg, J.M.1
Shi, Y.2
-
2
-
-
0035696107
-
Zinc biochemistry, physiology, and homeostasis - Recent insights and current trends
-
DOI 10.1023/A:1012945110820
-
W. Maret Zinc biochemistry, physiology, and homeostasis - recent insights and current trends Biometals 14 2001 187 190 (Pubitemid 34066628)
-
(2001)
BioMetals
, vol.14
, Issue.3-4
, pp. 187-190
-
-
Maret, W.1
-
3
-
-
0022458347
-
Kinetic analysis of zinc metabolism and its regulation in normal humans
-
M.E. Wastney, R.L. Aamodt, W.F. Rumble, and R.I. Henkin Kinetic analysis of zinc metabolism and its regulation in normal humans Am. J. Physiol. 251 1986 398 408
-
(1986)
Am. J. Physiol.
, vol.251
, pp. 398-408
-
-
Wastney, M.E.1
Aamodt, R.L.2
Rumble, W.F.3
Henkin, R.I.4
-
4
-
-
0027394031
-
The biochemical basis of zinc physiology
-
B.L. Vallee, and K.H. Falchuk The biochemical basis of zinc physiology Physiol. Rev. 73 1993 79 118 (Pubitemid 23065434)
-
(1993)
Physiological Reviews
, vol.73
, Issue.1
, pp. 79-118
-
-
Vallee, B.L.1
Falchuk, K.H.2
-
7
-
-
0036804354
-
Induction of apoptosis in mammalian cells by cadmium and zinc
-
W. Watjen, H. Haase, M. Biagioli, and D. Beyersmann Induction of apoptosis in mammalian cells by cadmium and zinc Environ. Health Perspect. 110 2002 865 867 (Pubitemid 35276883)
-
(2002)
Environmental Health Perspectives
, vol.110
, Issue.SUPPL. 5
, pp. 865-867
-
-
Watjen, W.1
Haase, H.2
Biagioli, M.3
Beyersmann, D.4
-
8
-
-
0023491126
-
Pulmonary involvement in zinc fume fever
-
C. Vogelmeier, G. Konig, K. Bencze, and G. Fruhmann Pulmonary involvement in zinc fume fever Chest 92 1987 946 948 (Pubitemid 18008645)
-
(1987)
Chest
, vol.92
, Issue.5
, pp. 946-948
-
-
Vogelmeier, C.1
Konig, G.2
Bencze, K.3
Fruhmann, G.4
-
9
-
-
33751129896
-
Metal-fume fever from inhaling zinc oxide
-
L.C. Rohrs Metal-fume fever from inhaling zinc oxide AMA Arch. Ind. Health 16 1957 42 47
-
(1957)
AMA Arch. Ind. Health
, vol.16
, pp. 42-47
-
-
Rohrs, L.C.1
-
10
-
-
0026567049
-
Pulmonary vascular lesions in the adult respiratory distress syndrome caused by inhalation of zinc chloride smoke: A morphometric study
-
S. Homma, R. Jones, J. Qvist, W.M. Zapol, and L. Reid Pulmonary vascular lesions in the adult respiratory distress syndrome caused by inhalation of zinc chloride smoke: a morphometric study Hum. Pathol. 23 1992 45 50
-
(1992)
Hum. Pathol.
, vol.23
, pp. 45-50
-
-
Homma, S.1
Jones, R.2
Qvist, J.3
Zapol, W.M.4
Reid, L.5
-
13
-
-
0023195782
-
The effect of zinc supplements on plasma zinc and copper levels and the reported symptoms in healthy volunteers
-
S. Samman, and D.C. Roberts The effect of zinc supplements on plasma zinc and copper levels and the reported symptoms in healthy volunteers Med. J. Aust. 146 1987 246 249 (Pubitemid 17117302)
-
(1987)
Medical Journal of Australia
, vol.146
, Issue.5
, pp. 246-249
-
-
Samman, S.1
Robert, D.C.K.2
-
14
-
-
0037686489
-
Detection and characterization of zinc- and cadmium-binding proteins in Escherichia coli by gel electrophoresis and laser ablation-inductively coupled plasma-mass spectrometry
-
DOI 10.1016/S0003-2697(03)00190-8
-
M.R.B. Binet, R. Ma, C.W. McLeod, and R.K. Poole Detection and characterization of zinc- and cadmium-binding proteins in Escherichia coli by gel electrophoresis and laser ablation-inductively coupled plasma-mass spectrometry Anal. Biochem. 318 2003 30 38 (Pubitemid 36627480)
-
(2003)
Analytical Biochemistry
, vol.318
, Issue.1
, pp. 30-38
-
-
Binet, M.R.B.1
Ma, R.2
McLeod, C.W.3
Poole, R.K.4
-
15
-
-
73449099594
-
Cerebral Bioimaging of Cu, Fe, Zn and Mn in the MPTP Mouse Model of Parkinson's Disease Using Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS)
-
A. Matusch, C. Depboylu, C. palm, B. Wu, G.U. Hogliner, M.K.H. Schafer, and J.S. Becker Cerebral Bioimaging of Cu, Fe, Zn and Mn in the MPTP Mouse Model of Parkinson's Disease Using Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) J. Am. Soc. Mass Spectrom. 21 2010 161 171
-
(2010)
J. Am. Soc. Mass Spectrom.
, vol.21
, pp. 161-171
-
-
Matusch, A.1
Depboylu, C.2
Palm, C.3
Wu, B.4
Hogliner, G.U.5
Schafer, M.K.H.6
Becker, J.S.7
-
16
-
-
0035387928
-
A Schiff base complex of Zn(II) as a neutral carrier for highly selective PVC membrane sensors for the sulfate ion
-
DOI 10.1021/ac001449d
-
M. Shamsipur, M. Yousefi, M. Hosseini, M.R. Ganjali, H. Sharghi, and H. Naeimi A Schiff Base Complex of Zn(II) as a neutral carrier for highly selective pvc membrane sensors for the sulfate ion Anal. Chem. 73 2001 2869 2874 (Pubitemid 32868141)
-
(2001)
Analytical Chemistry
, vol.73
, Issue.13
, pp. 2869-2874
-
-
Shamsipur, M.1
Yousefi, M.2
Hosseini, M.3
Ganjali, M.R.4
Sharghi, H.5
Naeimi, H.6
-
17
-
-
33745727650
-
Copper (II)-selective potentiometric sensor based on Porphyrins in PVC matrix
-
V.K. Gupta, A.K. Jain, G. Maheshwari, and H. Lang Copper (II)-selective potentiometric sensor based on Porphyrins in PVC matrix Sens. Actuator B 117 2006 99 106
-
(2006)
Sens. Actuator B
, vol.117
, pp. 99-106
-
-
Gupta, V.K.1
Jain, A.K.2
Maheshwari, G.3
Lang, H.4
-
18
-
-
33646041279
-
A Cobalt (II) selective PVC membrane based on a schiff base complex of N, N'-bis (salicylidene)-3,4-diaminotoluene
-
V.K. Gupta, A.K. Singh, S. Mehtab, and B. Gupta A Cobalt (II) selective PVC membrane based on a schiff base complex of N, N'-bis (salicylidene)-3,4- diaminotoluene Anal. Chim. Acta 566 2006 5 10
-
(2006)
Anal. Chim. Acta
, vol.566
, pp. 5-10
-
-
Gupta, V.K.1
Singh, A.K.2
Mehtab, S.3
Gupta, B.4
-
19
-
-
33749254455
-
PVC-based membranes of N,N′-dibenzyl-1,4,10,13-tetraoxa-7,16- diazacyclooctadecane as Pb(II)-selective sensor
-
DOI 10.1016/j.snb.2006.02.019, PII S0925400506000980
-
V.K. Gupta, A.K. Jain, and P. Kumar PVC-based membranes of N, N'-dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclooctadecane as Pb (II)-selective sensor Sens. Actuator B 120 2006 259 265 (Pubitemid 44486698)
-
(2006)
Sensors and Actuators, B: Chemical
, vol.120
, Issue.1
, pp. 259-265
-
-
Gupta, V.K.1
Jain, A.K.2
Kumar, P.3
-
20
-
-
29244459114
-
Chromium(III)-selective sensor based on tri-o-thymotide in PVC matrix
-
DOI 10.1016/j.snb.2005.02.046, PII S0925400505002297
-
V.K. Gupta, A.K. Jain, P. Kumar, S. Agarwal, and G. Maheshwari Chromium (III)-selective sensor based on tri-o-thymotide in PVC matrix Sens. Actuator B 113 2006 182 186 (Pubitemid 41831285)
-
(2006)
Sensors and Actuators, B: Chemical
, vol.113
, Issue.1
, pp. 182-186
-
-
Gupta, V.K.1
Jain, A.K.2
Kumar, P.3
Agarwal, S.4
Maheshwari, G.5
-
21
-
-
32644434569
-
2+ selective sensors based on derivatized tetrapyrazole and calix[4]arene receptors
-
DOI 10.1016/j.electacta.2005.07.040, PII S0013468605008480
-
2+ sensors based on derivatized tetrapyrazole and calix[4] arene receptors Electrochim. Acta 51 2006 2547 2553 (Pubitemid 43243734)
-
(2006)
Electrochimica Acta
, vol.51
, Issue.12
, pp. 2547-2553
-
-
Jain, A.K.1
Gupta, V.K.2
Singh, L.P.3
Raisoni, J.R.4
-
22
-
-
34047129318
-
Neutral carriers based polymeric membrane electrodes for selective determination of mercury (II)
-
DOI 10.1016/j.aca.2007.03.014, PII S0003267007004965
-
V.K. Gupta, A.K. Singh, M. Al Khayat, and B. Gupta Neutral carriers based polymeric membrane electrodes for selective determination of Mercury (II) Anal. Chim. Acta 590 2007 81 90 (Pubitemid 46528388)
-
(2007)
Analytica Chimica Acta
, vol.590
, Issue.1
, pp. 81-90
-
-
Gupta, V.K.1
Singh, A.K.2
Al Khayat, M.3
Gupta, B.4
-
23
-
-
33846178200
-
Schiff bases as cadmium(II) selective ionophores in polymeric membrane electrodes
-
DOI 10.1016/j.aca.2006.10.039, PII S0003267006021167
-
V.K. Gupta, A.K. Singh, and B. Gupta Schiff Bases as Cadmium (II) selective ionophores in polymeric membrane electrodes Anal. Chim. Acta 583 2007 340 348 (Pubitemid 46080373)
-
(2007)
Analytica Chimica Acta
, vol.583
, Issue.2
, pp. 340-348
-
-
Gupta, V.K.1
Singh, A.K.2
Gupta, B.3
-
24
-
-
0037569436
-
Preparation of ethambutol-copper (II) complex and fabrication of PVC based membrane potentiometric sensor for copper
-
V.K. Gupta, R. Prasad, and A. Kumar Preparation of ethambutol-copper (II) complex and fabrication of PVC based membrane potentiometric sensor for copper Talanta 60 2003 149 160
-
(2003)
Talanta
, vol.60
, pp. 149-160
-
-
Gupta, V.K.1
Prasad, R.2
Kumar, A.3
-
25
-
-
0036499849
-
Dicyclohexano-18-crown-6 as active material in PVC matrix membrane for the fabrication of cadmium selective potentiometric sensor
-
DOI 10.1016/S0013-4686(01)00895-7, PII S0013468601008957
-
V.K. Gupta, S. Chandra, R. Mangla, Dicyclohexano-18-crown-6 as active material in PVC matrix membrane for the fabrication of cadmium selective potentiometric sensor, Electrochim. Acta 47 (2002) 1579-1586. (Pubitemid 34182451)
-
(2002)
Electrochimica Acta
, vol.47
, Issue.10
, pp. 1579-1586
-
-
Gupta, V.K.1
Chandra, S.2
Mangla, R.3
-
26
-
-
0000000504
-
Determination of uranyl Ions using Poly (Vinyl Chloride) based 4-tert-butylcalix[6]-arene membrane sensor
-
V.K. Gupta, R. Mangla, U. Khurana, and P. Kumar Determination of uranyl Ions using Poly (Vinyl Chloride) based 4-tert-butylcalix[6]-arene membrane sensor Electroanalysis 11 1999 573 576
-
(1999)
Electroanalysis
, vol.11
, pp. 573-576
-
-
Gupta, V.K.1
Mangla, R.2
Khurana, U.3
Kumar, P.4
-
27
-
-
0001101267
-
A PVC-Based Pentathia-15-Crown-5 Membrane Potentiometric Sensor for Mercury(II)
-
V.K. Gupta, S. Jain, and U. Khurana A PVC based pentathia-15-crown-5 membrane potentiometric sensor for mercury (II) Electroanalysis 9 1997 478 480 (Pubitemid 127444109)
-
(1997)
Electroanalysis
, vol.9
, Issue.6
, pp. 478-480
-
-
Gupta, V.K.1
Jain, S.2
Khurana, U.3
-
28
-
-
0012264013
-
Pyrogallol immobilized Amberlite XAD-2: A newly designed collector for enrichment of metal ions prior to their determination by flame atomic absorption spectrometry
-
M. Kumar, D.P.S. Rathore, and A.K. Singh Pyrogallol immobilized amberlite XAD-2: a newly designed collector for enrichment of metal ions prior to their determination by flame atomic absorption spectrometry Microchim. Acta 137 2001 127 134 (Pubitemid 33752062)
-
(2001)
Mikrochimica Acta
, vol.137
, Issue.3-4
, pp. 127-134
-
-
Kumar, M.1
Rathore, D.P.S.2
Singh, A.K.3
-
29
-
-
0034534859
-
Thiosalicylic acid-immobilized Amberlite XAD-2: Metal sorption behaviour and applications in estimation of metal ions by flame atomic absorption spectrometry
-
DOI 10.1039/b006788l
-
P.K. Tewari, and A.K. Singh Thiosalicylic acid-immobilized amberlite XAD-2: metal sorption behaviour and applications in estimation of metal ions by flame atomic absorption spectrometry Analyst 125 2000 2350 2355 (Pubitemid 32015117)
-
(2000)
Analyst
, vol.125
, Issue.12
, pp. 2350-2355
-
-
Tewari, P.K.1
Singh, A.K.2
-
30
-
-
84883472003
-
Real-time electrochemical monitoring of adenosine triphosphate in the picomolar to micromolar range using graphene-modified electrodes
-
B.J. Sanghavi, S. Sitaula, M.H. Griep, S.P. Karna, M.F. Ali, and N.S. Swami Real-time electrochemical monitoring of adenosine triphosphate in the picomolar to micromolar range using graphene-modified electrodes Anal. Chem. 85 2013 8158 8165
-
(2013)
Anal. Chem.
, vol.85
, pp. 8158-8165
-
-
Sanghavi, B.J.1
Sitaula, S.2
Griep, M.H.3
Karna, S.P.4
Ali, M.F.5
Swami, N.S.6
-
31
-
-
84899788551
-
Electrokinetic preconcentration and detection of neuropeptides at patterned graphene-modified electrodes in a nanochannel
-
B.J. Sanghavi, W. Harhue, J.L. Chávez, C.F. Chou, and N.S. Swami Electrokinetic preconcentration and detection of neuropeptides at patterned graphene-modified electrodes in a nanochannel Anal. Chem. 85 2014 4120 4125
-
(2014)
Anal. Chem.
, vol.85
, pp. 4120-4125
-
-
Sanghavi, B.J.1
Harhue, W.2
Chávez, J.L.3
Chou, C.F.4
Swami, N.S.5
-
32
-
-
84865754591
-
Biomimetic sensor for certain catecholamines employing copper(II) complex and silver nanoparticle modified glassy carbon paste electrode Biosens
-
B.J. Sanghavi, M.S. Mobin, P. Mathur, G.K. Lahiri, and A.K. Srivastava Biomimetic sensor for certain catecholamines employing copper(II) complex and silver nanoparticle modified glassy carbon paste electrode Biosens Bioelectronic 39 2013 124 132
-
(2013)
Bioelectronic
, vol.39
, pp. 124-132
-
-
Sanghavi, B.J.1
Mobin, M.S.2
Mathur, P.3
Lahiri, G.K.4
Srivastava, A.K.5
-
33
-
-
78049244463
-
Simultaneous voltammetric determination of acetaminophen, aspirin and caffeine using an in situ surfactant-modified multiwalled carbon nanotube paste electrode
-
B.J. Sanghavi, A.K. Srivastava, Simultaneous voltammetric determination of acetaminophen, aspirin and caffeine using an in situ surfactant-modified multiwalled carbon nanotube paste electrode, Electrochim. Acta 55 (2010) 8638-8648.
-
(2010)
Electrochim. Acta
, vol.55
, pp. 8638-8648
-
-
Sanghavi, B.J.1
Srivastava, A.K.2
-
34
-
-
79954583931
-
Adsorptive stripping differential pulse voltammetric determination of venlafaxine and desvenlafaxine employing Nafion-carbon nanotube composite glassy carbon electrode
-
B.J. Sanghavi, and A.K. Srivastava Adsorptive stripping differential pulse voltammetric determination of venlafaxine and desvenlafaxine employing Nafion-carbon nanotube composite glassy carbon electrode Electrochim. Acta 56 2011 4188 4196
-
(2011)
Electrochim. Acta
, vol.56
, pp. 4188-4196
-
-
Sanghavi, B.J.1
Srivastava, A.K.2
-
35
-
-
12844288686
-
Quantitative determination of zinc in milkvetch by anodic stripping voltammetry with bismuth film electrodes
-
DOI 10.1016/j.talanta.2004.08.060, PII S0039914004005077
-
Z. Guo, F. Feng, Y. Hou, and N.J. Renault Quantitative determination of zinc in milkvetch by anodic stripping voltammetry with bismuth film electrodes Talanta 65 2005 1052 1055 (Pubitemid 40170398)
-
(2005)
Talanta
, vol.65
, Issue.4
, pp. 1052-1055
-
-
Guo, Z.1
Feng, F.2
Hou, Y.3
Jaffrezic-Renault, N.4
-
36
-
-
1142303789
-
Fluorescent detection of zinc in biological systems: Recent development on the disgn of chemosensors and biosensors
-
P. Jiang, and Z. Guo Fluorescent detection of zinc in biological systems: recent development on the disgn of chemosensors and biosensors Coord. Chem. Rev. 248 2004 205 209
-
(2004)
Coord. Chem. Rev.
, vol.248
, pp. 205-209
-
-
Jiang, P.1
Guo, Z.2
-
37
-
-
35148838050
-
Calixarene-derived fluorescent probes
-
DOI 10.1021/cr068046j
-
J.S. Kim, and D.T. Quang Calixarene-derived fluorescent probes Chem. Rev. 107 2007 3780 3799 (Pubitemid 47541850)
-
(2007)
Chemical Reviews
, vol.107
, Issue.9
, pp. 3780-3799
-
-
Kim, J.S.1
Quang, D.T.2
-
39
-
-
0031191655
-
Signaling recognition events with fluorescent sensors and switches
-
A.P. de Silva, H.Q.N. Gunaratne, T. Gunnlaugsson, A.J.M. Huxley, C.P. McCoy, J.T. Rademacher, and T.E. Rice Signaling recognition events with fluorescent sensors and switches Chem. Rev. 97 1997 1515 1566 (Pubitemid 127659605)
-
(1997)
Chemical Reviews
, vol.97
, Issue.5
, pp. 1515-1566
-
-
De Silva, A.P.1
Gunaratne, H.Q.N.2
Gunnlaugsson, T.3
Huxley, A.J.M.4
McCoy, C.P.5
Rademacher, J.T.6
Rice, T.E.7
-
40
-
-
31644436289
-
Light-emitting molecular devices based on transition metals
-
V. Amendola, L. Fabbrizzi, F. Foti, M. Licchelli, C. Mangano, P. Pallavicini, A. Poggi, D. Sacchi, and A. Taglietti Light-emitting molecular devices based on transition metals Coord. Chem. Rev. 250 2006 273 299
-
(2006)
Coord. Chem. Rev.
, vol.250
, pp. 273-299
-
-
Amendola, V.1
Fabbrizzi, L.2
Foti, F.3
Licchelli, M.4
Mangano, C.5
Pallavicini, P.6
Poggi, A.7
Sacchi, D.8
Taglietti, A.9
-
42
-
-
84891593072
-
Antipyrine based Schiff bases as Turn-on Fluorescent sensors for Al(III) ion
-
V.K. Gupta, A.K. Singh, and N. Mergu Antipyrine based Schiff bases as Turn-on Fluorescent sensors for Al(III) ion Electrochim. Acta 117 2014 405 412
-
(2014)
Electrochim. Acta
, vol.117
, pp. 405-412
-
-
Gupta, V.K.1
Singh, A.K.2
Mergu, N.3
-
43
-
-
84961983878
-
A highly selective and sensitive in vivo fluorosensor for zinc(II) without cytotoxicity
-
T. Mistri, M. Dolai, D. Chakraborty, A.R. Khuda-Bukhsh, K.K. Das, and M. Ali A highly selective and sensitive in vivo fluorosensor for zinc(II) without cytotoxicity Org. Biomol. Chem. 10 2012 2380 2384
-
(2012)
Org. Biomol. Chem.
, vol.10
, pp. 2380-2384
-
-
Mistri, T.1
Dolai, M.2
Chakraborty, D.3
Khuda-Bukhsh, A.R.4
Das, K.K.5
Ali, M.6
-
45
-
-
1642494634
-
Emission Ratiometric Imaging of Intracellular Zinc: Design of a Benzoxazole Fluorescent Sensor and Its Application in Two-Photon Microscopy
-
DOI 10.1021/ja039073j
-
M. Taki, J.L. Wolford, and T.V. O'Halloran Emission ratiometric imaging of intracellular zinc: design of a benzoxazole fluorescent sensor and its application in two-photon microscopy J. Am. Chem. Soc. 126 2004 712 713 (Pubitemid 38114344)
-
(2004)
Journal of the American Chemical Society
, vol.126
, Issue.3
, pp. 712-713
-
-
Taki, M.1
Wolford, J.L.2
O'Halloran, T.V.3
-
46
-
-
84872873717
-
A quinoline based fluorescent probe that can distinguish zinc(II) from cadmium(II) in water
-
Y. Cai, X. Meng, S. Wanga, M. Zhu, Z. Pan, and Q.X. Guo A quinoline based fluorescent probe that can distinguish zinc(II) from cadmium(II) in water Tetrahedron Lett. 54 2013 1125 1128
-
(2013)
Tetrahedron Lett.
, vol.54
, pp. 1125-1128
-
-
Cai, Y.1
Meng, X.2
Wanga, S.3
Zhu, M.4
Pan, Z.5
Guo, Q.X.6
-
47
-
-
67649654477
-
High sensitive determination of zinc with novel water-soluble small molecular fluorescent sensor
-
Y. Weng, Z. Chen, F. Wang, L. Xue, and H. Jiang High sensitive determination of zinc with novel water-soluble small molecular fluorescent sensor Anal. Chim. Acta 647 2009 215 218
-
(2009)
Anal. Chim. Acta
, vol.647
, pp. 215-218
-
-
Weng, Y.1
Chen, Z.2
Wang, F.3
Xue, L.4
Jiang, H.5
-
48
-
-
78751569561
-
A novel small molecule fluorescent sensor for Zn2+ based on pyridine-pyridone scaffold
-
M. Hagimori, N. Mizuyama, Y. Yamaguchi, H. Saji, and Y. Tominaga A novel small molecule fluorescent sensor for Zn2+ based on pyridine-pyridone scaffold Talanta 83 2011 1730 1735
-
(2011)
Talanta
, vol.83
, pp. 1730-1735
-
-
Hagimori, M.1
Mizuyama, N.2
Yamaguchi, Y.3
Saji, H.4
Tominaga, Y.5
-
49
-
-
3242752339
-
Synthesis and characterization of zinc sensors based on a monosubstituted fluorescein platform
-
E.M. Nolan, S.C. Burdette, J.H. Hervey, S.A. Hilderbrand, and S.J. Lippard Synthesis and characterization of zinc sensors based on a monosubstituted fluorescein platform Inorg. Chem. 43 2004 2624 2635
-
(2004)
Inorg. Chem.
, vol.43
, pp. 2624-2635
-
-
Nolan, E.M.1
Burdette, S.C.2
Hervey, J.H.3
Hilderbrand, S.A.4
Lippard, S.J.5
-
50
-
-
6044257947
-
Metal chelation-controlled twisted intramolecular charge transfer and its application to fluorescent sensing of metal ions and anions
-
DOI 10.1021/ja040095v
-
S. Aoki, D. Kagata, M. Shiro, K. Takeda, and E. Kimura Metal chelation-controlled twisted intramolecular charge transfer and its application to fluorescent sensing of metal ions and anions J. Am. Chem. Soc. 126 2004 13377 13390 (Pubitemid 39382766)
-
(2004)
Journal of the American Chemical Society
, vol.126
, Issue.41
, pp. 13377-13390
-
-
Aoki, S.1
Kagata, D.2
Shiro, M.3
Takeda, K.4
Kimura, E.5
-
51
-
-
84862225474
-
Synthesis of novel Schiff base analogues of 4-amino-1, 5-dimethyl-2-phenylpyrazol-3-one and their evaluation for antioxidant and anti-inflammatory activity
-
M.S. Alam, J.H. Choi, and D.U. Lee Synthesis of novel Schiff base analogues of 4-amino-1, 5-dimethyl-2-phenylpyrazol-3-one and their evaluation for antioxidant and anti-inflammatory activity Bioorg. Med. Chem. 20 2012 4103 4108
-
(2012)
Bioorg. Med. Chem.
, vol.20
, pp. 4103-4108
-
-
Alam, M.S.1
Choi, J.H.2
Lee, D.U.3
-
53
-
-
34248395111
-
Aluminum(III) selective potentiometric sensor based on morin in poly(vinyl chloride) matrix
-
DOI 10.1016/j.talanta.2007.01.064, PII S0039914007001105
-
V.K. Gupta, A.K. Jain, and G. Maheshwari Novel Aluminum (III) selective potentiometric sensor based on morin in poly (vinyl chloride) matrix Talanta 72 2007 1469 1473 (Pubitemid 46734135)
-
(2007)
Talanta
, vol.72
, Issue.4
, pp. 1469-1473
-
-
Gupta, V.K.1
Jain, A.K.2
Maheshwari, G.3
-
54
-
-
80052880041
-
Electrochemical analysis of some toxic metals and drugs by ion selective electrodes
-
V.K. Gupta, M.R. Ganjali, P. Norouzi, H. Khani, A. Nayak, and S. Agarwal Electrochemical analysis of some toxic metals and drugs by ion selective electrodes Crit. Rev. Anal. Chem. 41 2011 282 313
-
(2011)
Crit. Rev. Anal. Chem.
, vol.41
, pp. 282-313
-
-
Gupta, V.K.1
Ganjali, M.R.2
Norouzi, P.3
Khani, H.4
Nayak, A.5
Agarwal, S.6
-
55
-
-
77955473978
-
Voltammetric biosensors for the determination of paracetamol at carbon nanotube modified pyrolytic graphite electrode
-
R.N. Goyal, V.K. Gupta, and S. Chatterjee Voltammetric biosensors for the determination of paracetamol at carbon nanotube modified pyrolytic graphite electrode Sens. Actuators B. Chem. 149 2010 252 258
-
(2010)
Sens. Actuators B. Chem.
, vol.149
, pp. 252-258
-
-
Goyal, R.N.1
Gupta, V.K.2
Chatterjee, S.3
-
56
-
-
33847743022
-
An iron(III) ion-selective sensor based on a μ-bis(tridentate) ligand
-
DOI 10.1016/j.talanta.2006.08.038, PII S0039914006006035
-
V.K. Gupta, A.K. Jain, S. Agarwal, and G. Maheshwari An iron (III) ion-selective sensor based on a m bis (tridentate) ligand Talanta 71 2007 1964 1968 (Pubitemid 46386180)
-
(2007)
Talanta
, vol.71
, Issue.5
, pp. 1964-1968
-
-
Gupta, V.K.1
Jain, A.K.2
Agarwal, S.3
Maheshwari, G.4
-
57
-
-
77956876969
-
Voltammetric determination of cefixime in pharmaceuticals and biological fluids
-
R. Jain, V.K. Gupta, N. Jadon, and K. Radhapyari Voltammetric determination of cefixime in pharmaceuticals and biological fluids Anal. Biochem. 407 2010 79 88
-
(2010)
Anal. Biochem.
, vol.407
, pp. 79-88
-
-
Jain, R.1
Gupta, V.K.2
Jadon, N.3
Radhapyari, K.4
-
58
-
-
43049142679
-
Electrochemical oxidation of 2', 3'-dideoxyadenosine at pyrolytic graphite electrode
-
R.N. Goyal, V.K. Gupta, and S. Chatterjee Electrochemical oxidation of 2', 3'-dideoxyadenosine at pyrolytic graphite electrode Electrochim. Acta 53 2008 5354 5360
-
(2008)
Electrochim. Acta
, vol.53
, pp. 5354-5360
-
-
Goyal, R.N.1
Gupta, V.K.2
Chatterjee, S.3
-
59
-
-
0034618790
-
New nickel (II) selective poten434tiometric sensor based on 5, 7, 12, 14-tetramethyldibenzotetraazaannulene in apoly (vinyl chloride) matrix
-
V.K. Gupta, R. Prasad, R. Mangla, and P. Kumar New nickel (II) selective poten434tiometric sensor based on 5, 7, 12, 14- tetramethyldibenzotetraazaannulene in apoly (vinyl chloride) matrix Anal. Chim. Acta 420 2000 19 27
-
(2000)
Anal. Chim. Acta
, vol.420
, pp. 19-27
-
-
Gupta, V.K.1
Prasad, R.2
Mangla, R.3
Kumar, P.4
-
60
-
-
44949166393
-
Simultaneous determination of adenosine and inosine using single-wall carbon nanotubes modified pyrolytic graphite electrode
-
R.N. Goal, V.K. Gupta, and S. Chatterjee Simultaneous determination of adenosine and inosine using single-wall carbon nanotubes modified pyrolytic graphite electrode Talanta 76 2008 662 668
-
(2008)
Talanta
, vol.76
, pp. 662-668
-
-
Goal, R.N.1
Gupta, V.K.2
Chatterjee, S.3
|