메뉴 건너뛰기




Volumn 1, Issue , 2014, Pages 53-59

Evaluating in situ thermal transmittance of green buildings masonries: A case study

Author keywords

Green buildings; Heat flux measurements; Infrared thermography; Masonry; Performance gap; U value

Indexed keywords


EID: 84906547790     PISSN: 22145095     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cscm.2014.04.004     Document Type: Article
Times cited : (147)

References (22)
  • 1
    • 77956174538 scopus 로고    scopus 로고
    • Infrared thermovision technique for the assessment of thermal transmittance value of opaque building elements on site
    • Albatici R., Tonelli A.M. Infrared thermovision technique for the assessment of thermal transmittance value of opaque building elements on site. Energy Build 2010, 42:2177-2183.
    • (2010) Energy Build , vol.42 , pp. 2177-2183
    • Albatici, R.1    Tonelli, A.M.2
  • 2
    • 79956373113 scopus 로고    scopus 로고
    • Thermal transmittance measurements with the hot box method: calibration, experimental procedures, and uncertainty analyses of three different approaches
    • Asdrubali F., Baldinelli G. Thermal transmittance measurements with the hot box method: calibration, experimental procedures, and uncertainty analyses of three different approaches. Energy Build 2011, 43(7):1618-1626.
    • (2011) Energy Build , vol.43 , Issue.7 , pp. 1618-1626
    • Asdrubali, F.1    Baldinelli, G.2
  • 4
    • 84862309498 scopus 로고    scopus 로고
    • A quantitative methodology to evaluate thermal bridges in buildings
    • Asdrubali F., Baldinelli G., Bianchi F. A quantitative methodology to evaluate thermal bridges in buildings. Appl Energy 2012, 97:365-373.
    • (2012) Appl Energy , vol.97 , pp. 365-373
    • Asdrubali, F.1    Baldinelli, G.2    Bianchi, F.3
  • 5
    • 84878466048 scopus 로고    scopus 로고
    • Life cycle analysis in the construction sector: guiding the optimization of conventional Italian buildings
    • Asdrubali F., Baldassarri C., Fthenakis V. Life cycle analysis in the construction sector: guiding the optimization of conventional Italian buildings. Energy Build 2013, 64:73-89.
    • (2013) Energy Build , vol.64 , pp. 73-89
    • Asdrubali, F.1    Baldassarri, C.2    Fthenakis, V.3
  • 7
    • 84876035447 scopus 로고    scopus 로고
    • Clarifying the new interpretations of the concept of sustainable building
    • Berardi U. Clarifying the new interpretations of the concept of sustainable building. Sustain Cities Soc 2013, 8:72-78.
    • (2013) Sustain Cities Soc , vol.8 , pp. 72-78
    • Berardi, U.1
  • 9
    • 80054812125 scopus 로고    scopus 로고
    • Comparing different approaches to in situ measurement of building components thermal resistance
    • Desogus G., Mura S., Ricciu R. Comparing different approaches to in situ measurement of building components thermal resistance. Energy Build 2011, 43:2613-2620.
    • (2011) Energy Build , vol.43 , pp. 2613-2620
    • Desogus, G.1    Mura, S.2    Ricciu, R.3
  • 13
    • 80052260341 scopus 로고    scopus 로고
    • Application of infrared thermography for the determination of the overall heat transfer coefficient (U-value) in building envelopes
    • Fokaides P.A., Kalogirou S.A. Application of infrared thermography for the determination of the overall heat transfer coefficient (U-value) in building envelopes. Appl Energy 2011, 88:4358-4365.
    • (2011) Appl Energy , vol.88 , pp. 4358-4365
    • Fokaides, P.A.1    Kalogirou, S.A.2
  • 18
    • 84867899944 scopus 로고    scopus 로고
    • Hot box measurements of pumice aggregate concrete hollow block walls
    • Kus H., Özkan E., Göcer Ö., Edis E. Hot box measurements of pumice aggregate concrete hollow block walls. Construct Build Mater 2013, 38:837-845.
    • (2013) Construct Build Mater , vol.38 , pp. 837-845
    • Kus, H.1    Özkan, E.2    Göcer, Ö.3    Edis, E.4
  • 19
    • 79955471390 scopus 로고    scopus 로고
    • Study of the geometry of a voided clay brick using rectangular perforations to optimize its thermal properties
    • Morales M.P., Juárez M.C., López-Ochoa L.M., Doménech J. Study of the geometry of a voided clay brick using rectangular perforations to optimize its thermal properties. Appl Therm Eng 2011, 31:2063-2065.
    • (2011) Appl Therm Eng , vol.31 , pp. 2063-2065
    • Morales, M.P.1    Juárez, M.C.2    López-Ochoa, L.M.3    Doménech, J.4
  • 20
    • 50349092493 scopus 로고    scopus 로고
    • In situ measuring and evaluating the thermal resistance of building construction
    • Peng C., Wu Z. In situ measuring and evaluating the thermal resistance of building construction. Energy Build 2008, 40:2076-2082.
    • (2008) Energy Build , vol.40 , pp. 2076-2082
    • Peng, C.1    Wu, Z.2
  • 21
    • 0022563645 scopus 로고
    • Measurement errors with surface-mounted heat flux sensors
    • Trethowen H. Measurement errors with surface-mounted heat flux sensors. Build Environ 1986, 21(1):41-56.
    • (1986) Build Environ , vol.21 , Issue.1 , pp. 41-56
    • Trethowen, H.1
  • 22
    • 0038178390 scopus 로고    scopus 로고
    • U-value of a dried wall made of perforated porous clay bricks: Hot box measurement versus numerical analysis
    • Wakili K.G., Tanner C. U-value of a dried wall made of perforated porous clay bricks: Hot box measurement versus numerical analysis. Energy Build 2003, 35:675-680.
    • (2003) Energy Build , vol.35 , pp. 675-680
    • Wakili, K.G.1    Tanner, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.