메뉴 건너뛰기




Volumn 38, Issue , 2013, Pages 837-845

Hot box measurements of pumice aggregate concrete hollow block walls

Author keywords

Concrete block; Hot box; Hygrothermal performance; Measurement; Pumice

Indexed keywords

BLOCK WALLS; HETEROGENEOUS MATERIALS; HOT BOX; HUMIDITY MEASUREMENTS; HYGROTHERMAL; HYGROTHERMAL PERFORMANCE; LOW THERMAL CONDUCTIVITY; MASONRY WALLS; OUTDOOR CLIMATE; PROBLEMATIC ISSUES; PUMICE AGGREGATE CONCRETES; ROUGH SURFACES; SCIENTIFIC KNOWLEDGE; THERMAL TRANSMITTANCE;

EID: 84867899944     PISSN: 09500618     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.conbuildmat.2012.09.053     Document Type: Article
Times cited : (33)

References (18)
  • 2
    • 0031162376 scopus 로고    scopus 로고
    • Environmental chamber for investigation of building performance
    • P. Fazio, A.K. Athienitis, C. Marsh, and J. Rao Environmental chamber for investigation of building performance J Architect Eng 3 2 1997 97 102
    • (1997) J Architect Eng , vol.3 , Issue.2 , pp. 97-102
    • Fazio, P.1    Athienitis, A.K.2    Marsh, C.3    Rao, J.4
  • 3
    • 0037400784 scopus 로고    scopus 로고
    • Hygrothermal calculations and laboratory tests on timber-framed wall structures
    • T. Kalamees, and J. Vinha Hygrothermal calculations and laboratory tests on timber-framed wall structures Build Environ 38 5 2003 689 697
    • (2003) Build Environ , vol.38 , Issue.5 , pp. 689-697
    • Kalamees, T.1    Vinha, J.2
  • 4
    • 34548309007 scopus 로고    scopus 로고
    • Comparison of experimental and numerical results of wood-frame wall assemblies wetted by simulated wind-driven rain infiltration
    • A. Teasdale-St-Hilaire, and D. Derome Comparison of experimental and numerical results of wood-frame wall assemblies wetted by simulated wind-driven rain infiltration Energy Build 39 11 2007 1131 1139
    • (2007) Energy Build , vol.39 , Issue.11 , pp. 1131-1139
    • Teasdale-St-Hilaire, A.1    Derome, D.2
  • 6
    • 4344716399 scopus 로고    scopus 로고
    • Reduced linear state model of hollow blocks walls, validation using hot box measurements
    • Y. Gao, J.J. Roux, C. Teodosiu, and L.H. Zhao Reduced linear state model of hollow blocks walls, validation using hot box measurements Energy Build 36 11 2004 1107 1115
    • (2004) Energy Build , vol.36 , Issue.11 , pp. 1107-1115
    • Gao, Y.1    Roux, J.J.2    Teodosiu, C.3    Zhao, L.H.4
  • 8
    • 0038178390 scopus 로고    scopus 로고
    • U-value of dried wall made of perforated porous clay bricks - Hot box measurement versus numerical analysis
    • K. Ghazi Wakili, and C. Tanner U-value of dried wall made of perforated porous clay bricks - hot box measurement versus numerical analysis Energy Build 35 7 2003 675 680
    • (2003) Energy Build , vol.35 , Issue.7 , pp. 675-680
    • Ghazi Wakili, K.1    Tanner, C.2
  • 9
    • 0035451561 scopus 로고    scopus 로고
    • Hygrothermal performance of hollow bricks and current standards
    • P. Bondi, and P. Stefanizzi Hygrothermal performance of hollow bricks and current standards Energy Build 33 7 2001 731 736
    • (2001) Energy Build , vol.33 , Issue.7 , pp. 731-736
    • Bondi, P.1    Stefanizzi, P.2
  • 10
    • 14544303171 scopus 로고    scopus 로고
    • Simulation of indoor temperature and humidity conditions including hygrothermal interactions with the building envelope
    • H.M. Künzel, A. Holm, D. Zirkelbach, and A.N. Karagiozis Simulation of indoor temperature and humidity conditions including hygrothermal interactions with the building envelope Sol Energy 78 4 2005 554 561
    • (2005) Sol Energy , vol.78 , Issue.4 , pp. 554-561
    • Künzel, H.M.1    Holm, A.2    Zirkelbach, D.3    Karagiozis, A.N.4
  • 11
    • 0029769825 scopus 로고    scopus 로고
    • Hygrothermal performance of a new briquette design
    • M. Özdeniz Hygrothermal performance of a new briquette design Build Environ 31 1 1996 59 65
    • (1996) Build Environ , vol.31 , Issue.1 , pp. 59-65
    • Özdeniz, M.1
  • 12
    • 46249091366 scopus 로고    scopus 로고
    • Integrated methodology for evaluation of energy performance of the building eclosures - Part I: Test program development
    • M. Bomberg, and T. Thorsell Integrated methodology for evaluation of energy performance of the building eclosures - part I: test program development J Build Phys 32 1 2008 33 48
    • (2008) J Build Phys , vol.32 , Issue.1 , pp. 33-48
    • Bomberg, M.1    Thorsell, T.2
  • 13
    • 46249102898 scopus 로고    scopus 로고
    • Integrated methodology for evaluation of energy performance of the building eclosures - Part II: Examples of application to residential walls
    • T. Thorsell, and M. Bomberg Integrated methodology for evaluation of energy performance of the building eclosures - part II: examples of application to residential walls J Build Phys 32 1 2008 49 65
    • (2008) J Build Phys , vol.32 , Issue.1 , pp. 49-65
    • Thorsell, T.1    Bomberg, M.2
  • 14
    • 84870420893 scopus 로고    scopus 로고
    • ORNL Buildings Technology Center, Building Envelopes Program, Hotbox Test R-value Database, Masonry Systems, Concrete masonry unit; (accessed 15.01.09)
    • Kosny J. ORNL Buildings Technology Center, Building Envelopes Program, Hotbox Test R-value Database, Masonry Systems, Concrete masonry unit; < http://www.ornl.gov/sci/roofs%2Bwalls/AWT/HotboxTest/Masonry/StaqableSymmetry/ index.htm > (accessed 15.01.09).
    • Kosny, J.1
  • 16
    • 84870440798 scopus 로고    scopus 로고
    • Standard test method for thermal performance of building materials and envelope assemblies by means of a hot box apparatus
    • Astm C 1363
    • ASTM C 1363 Standard test method for thermal performance of building materials and envelope assemblies by means of a hot box apparatus ASTM C 1363 2005
    • (2005) ASTM C 1363
  • 17
    • 84870434965 scopus 로고
    • Thermal insulation - Determination of steady-state thermal transmission properties - Calibrated and guarded hot box
    • En Iso 8990
    • EN ISO 8990 Thermal insulation - determination of steady-state thermal transmission properties - calibrated and guarded hot box ISO 8990 1994
    • (1994) ISO 8990


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.