메뉴 건너뛰기




Volumn 14, Issue 9, 2014, Pages

What monitor can replace the cathode-ray tube for visual stimulation to elicit multifocal electroretinograms?

Author keywords

Cathode ray tube; Liquid crystal display; Multifocal erg; Organic electroluminescence monitor

Indexed keywords

ARTICLE; CATHODE RAY TUBE; CATHODE-RAY TUBE; COMPARATIVE STUDY; COMPUTER TERMINAL; ELECTRORETINOGRAPHY; EQUIPMENT; FEMALE; HUMAN; LIQUID CRYSTAL DISPLAY; MALE; MULTIFOCAL ERG; ORGANIC ELECTROLUMINESCENCE MONITOR; PHOTOSTIMULATION; PHYSIOLOGY; RETINA; YOUNG ADULT;

EID: 84906097456     PISSN: None     EISSN: 15347362     Source Type: Journal    
DOI: 10.1167/14.9.2     Document Type: Article
Times cited : (8)

References (18)
  • 1
    • 79959762732 scopus 로고    scopus 로고
    • Contemporary LCD monitor parameters: Objective and subjective analysis
    • Retrieved April 1, 2010 from
    • Artamonov, O. (2007). Contemporary LCD monitor parameters: Objective and subjective analysis. Retrieved April 1, 2010 from www.xbitlabs.com/articles/monitors/display/lcd-parameters.html.
    • (2007)
    • Artamonov, O.1
  • 3
    • 84894350641 scopus 로고    scopus 로고
    • Assessment of OLED displays for vision research
    • 16 doi:10.1167/13.12.16. [PubMed] [Article]
    • Cooper, E. A., Jiang, H., Vildavski, V., Farrell, J. E., & Norcia, A. M. (2013). Assessment of OLED displays for vision research. Journal of Vision, 13(12):16, 1-13, http://www.journalofvision.org/ content/13/12/16, doi:10.1167/13.12.16. [PubMed] [Article]
    • (2013) Journal of Vision , vol.13 , Issue.12 , pp. 1-13
    • Cooper, E.A.1    Jiang, H.2    Vildavski, V.3    Farrell, J.E.4    Norcia, A.M.5
  • 5
    • 77955775881 scopus 로고    scopus 로고
    • Achieving precise display timing in visual neuroscience experiments
    • Elze, T. (2010). Achieving precise display timing in visual neuroscience experiments. Journal of Neuroscience Methods, 191, 171-179.
    • (2010) Journal of Neuroscience Methods , vol.191 , pp. 171-179
    • Elze, T.1
  • 6
    • 84883807735 scopus 로고    scopus 로고
    • An evaluation of organic light emitting diode monitors for medical applications: Great timing, but luminance artifacts
    • doi:10.1118/ 1.4818056
    • Elze, T., Taylor, C., & Bex, P. J. (2013). An evaluation of organic light emitting diode monitors for medical applications: Great timing, but luminance artifacts. Medical Physics, 40, 092701, doi:10.1118/ 1.4818056.
    • (2013) Medical Physics , vol.40
    • Elze, T.1    Taylor, C.2    Bex, P.J.3
  • 9
    • 84882595555 scopus 로고    scopus 로고
    • Evaluation of an organic light-emitting diode display for precise visual stimulation
    • 6 doi:10.1167/13.7.6. [PubMed] [Article]
    • Ito, H., Ogawa, M., & Sunaga, S. (2013). Evaluation of an organic light-emitting diode display for precise visual stimulation. Journal of Vision, 13(7):6, 1-21, http://www.journalofvision.org/content/13/7/6, doi:10.1167/13.7.6. [PubMed] [Article]
    • (2013) Journal of Vision , vol.13 , Issue.7 , pp. 1-21
    • Ito, H.1    Ogawa, M.2    Sunaga, S.3
  • 10
    • 67349275330 scopus 로고    scopus 로고
    • A comparison of the suitability of cathode ray tube (CRT) and liquid crystal display (LCD) monitors as visual stimulators in mfERG diagnostics
    • Kaltwasser, C., Horn, F. K., Kremers, J., & Juenemann, A. (2009). A comparison of the suitability of cathode ray tube (CRT) and liquid crystal display (LCD) monitors as visual stimulators in mfERG diagnostics. Documenta Ophthalmologica, 118, 179- 189.
    • (2009) Documenta Ophthalmologica , vol.118 , pp. 179-189
    • Kaltwasser, C.1    Horn, F.K.2    Kremers, J.3    Juenemann, A.4
  • 11
    • 84884825447 scopus 로고    scopus 로고
    • Liquid crystal display screens as stimulators for visually evoked potentials: Flash effect due to delay in luminance changes
    • Matsumoto, C. S., Shinoda, K., Matsumoto, H., Funada, H., Minoda, H., & Mizota, A. (2013). Liquid crystal display screens as stimulators for visually evoked potentials: Flash effect due to delay in luminance changes. Documenta Ophthalmologica, 127, 102-112.
    • (2013) Documenta Ophthalmologica , vol.127 , pp. 102-112
    • Matsumoto, C.S.1    Shinoda, K.2    Matsumoto, H.3    Funada, H.4    Minoda, H.5    Mizota, A.6
  • 12
    • 0004112033 scopus 로고
    • Chicago: University of Chicago Press
    • Michelson, A. (1927). Studies in optics. Chicago: University of Chicago Press.
    • (1927) Studies in optics
    • Michelson, A.1
  • 14
    • 0036483342 scopus 로고    scopus 로고
    • The concept of induced components in multifocal electroretinograms
    • Shimada, Y. (2002). The concept of induced components in multifocal electroretinograms. Nihon Ganka Gakkai Zasshi, 106, 69-76.
    • (2002) Nihon Ganka Gakkai Zasshi , vol.106 , pp. 69-76
    • Shimada, Y.1
  • 15
    • 0033709133 scopus 로고    scopus 로고
    • The interpretation of multifocal binary kernels
    • Sutter, E. (2000). The interpretation of multifocal binary kernels. Documenta Ophthalmologica, 100, 49-75.
    • (2000) Documenta Ophthalmologica , vol.100 , pp. 49-75
    • Sutter, E.1
  • 16
    • 0026541378 scopus 로고
    • The field topography of ERG components in man-I The photopic luminance response
    • Sutter, E. E., & Tran, D. (1992). The field topography of ERG components in man-I. The photopic luminance response. Vision Research, 32, 433-446
    • (1992) Vision Research , vol.32 , pp. 433-446
    • Sutter, E.E.1    Tran, D.2
  • 17
    • 0032897630 scopus 로고    scopus 로고
    • Photostimulation that induces flattening of photopic electroretinograms-first report An apparatus for slope photostimulation
    • Uno, N., Tahara, K., Nakao, Y., & Otori, T. (1999). Photostimulation that induces flattening of photopic electroretinograms-first report. An apparatus for slope photostimulation. Nihon Ganka Gakkai Zasshi, 103, 311-317.
    • (1999) Nihon Ganka Gakkai Zasshi , vol.103 , pp. 311-317
    • Uno, N.1    Tahara, K.2    Nakao, Y.3    Otori, T.4
  • 18
    • 0029410778 scopus 로고
    • A topographic study of oscillatory potentials in man
    • Wu, S., & Sutter, E. E. (1995). A topographic study of oscillatory potentials in man. Visual Neuroscience, 12, 1013-1025.
    • (1995) Visual Neuroscience , vol.12 , pp. 1013-1025
    • Wu, S.1    Sutter, E.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.