메뉴 건너뛰기




Volumn 1359, Issue , 2014, Pages 303-308

Capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry for quantitative parallel reaction monitoring of peptide abundance and single-shot proteomic analysis of a human cell line

Author keywords

CZE ESI MS MS; CZE PRM; Human cell lysate digest; Shotgun proteomics; Ultrasensitive electrokinetically pumped sheath flow nanospray interface

Indexed keywords

CAPILLARY ELECTROPHORESIS; CELL CULTURE; MAMMALS; MASS SPECTROMETRY; MOLECULAR BIOLOGY;

EID: 84906060568     PISSN: 00219673     EISSN: 18733778     Source Type: Journal    
DOI: 10.1016/j.chroma.2014.07.024     Document Type: Article
Times cited : (22)

References (45)
  • 2
    • 78650266493 scopus 로고    scopus 로고
    • Capillary electrophoresis-mass spectrometry for the analysis of intact proteins 2007-2010
    • Haselberg R., de Jong G.J., Somsen G.W. Capillary electrophoresis-mass spectrometry for the analysis of intact proteins 2007-2010. Electrophoresis 2011, 32:66-82.
    • (2011) Electrophoresis , vol.32 , pp. 66-82
    • Haselberg, R.1    de Jong, G.J.2    Somsen, G.W.3
  • 3
    • 78149291420 scopus 로고    scopus 로고
    • Naturally occurring human urinary peptides for use in diagnosis of chronic kidney disease
    • Good G.M., et al. Naturally occurring human urinary peptides for use in diagnosis of chronic kidney disease. Mol. Cell. Proteomics 2010, 9:2424-2437.
    • (2010) Mol. Cell. Proteomics , vol.9 , pp. 2424-2437
    • Good, G.M.1
  • 4
    • 84871941512 scopus 로고    scopus 로고
    • CE-MS for metabolomics: developments and applications in the period 2010-2012
    • Ramautar R., Somsen G.W., de Jong G.J. CE-MS for metabolomics: developments and applications in the period 2010-2012. Electrophoresis 2013, 34:86-98.
    • (2013) Electrophoresis , vol.34 , pp. 86-98
    • Ramautar, R.1    Somsen, G.W.2    de Jong, G.J.3
  • 5
    • 51249098520 scopus 로고    scopus 로고
    • Twenty years of interface development for capillary electrophoresis-electrospray ionization-mass spectrometry
    • Maxwell E.J., Chen D.D. Twenty years of interface development for capillary electrophoresis-electrospray ionization-mass spectrometry. Anal. Chim. Acta 2008, 627:25-33.
    • (2008) Anal. Chim. Acta , vol.627 , pp. 25-33
    • Maxwell, E.J.1    Chen, D.D.2
  • 6
    • 84896787429 scopus 로고    scopus 로고
    • Capillary zone electrophoresis for analysis of complex proteomes using an electrokinetically pumped sheath flow nanospray interface
    • Sun L., Zhu G., Yan X., Champion M.M., Dovichi N.J. Capillary zone electrophoresis for analysis of complex proteomes using an electrokinetically pumped sheath flow nanospray interface. Proteomics 2014, 14:622-628.
    • (2014) Proteomics , vol.14 , pp. 622-628
    • Sun, L.1    Zhu, G.2    Yan, X.3    Champion, M.M.4    Dovichi, N.J.5
  • 7
    • 84887199391 scopus 로고    scopus 로고
    • High sensitivity capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry for the rapid analysis of complex proteomes
    • Sun L., Zhu G., Yan X., Dovichi N.J. High sensitivity capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry for the rapid analysis of complex proteomes. Curr. Opin. Chem. Biol. 2013, 17:795-800.
    • (2013) Curr. Opin. Chem. Biol. , vol.17 , pp. 795-800
    • Sun, L.1    Zhu, G.2    Yan, X.3    Dovichi, N.J.4
  • 9
    • 34250185717 scopus 로고    scopus 로고
    • Simplifying CE-MS operation. 2. Interfacing low-flow separation techniques to mass spectrometry using a porous tip
    • Moini M. Simplifying CE-MS operation. 2. Interfacing low-flow separation techniques to mass spectrometry using a porous tip. Anal. Chem. 2007, 79:4241-4246.
    • (2007) Anal. Chem. , vol.79 , pp. 4241-4246
    • Moini, M.1
  • 11
    • 84892972716 scopus 로고    scopus 로고
    • Low-picomolar analysis of peptides by on-line coupling of fritless solid-phase extraction to sheathless capillary electrophoresis-mass spectrometry
    • Medina-Casanellas S., Domínguez-Vega E., Benavente F., Sanz-Nebot V., Somsen G.W., de Jong G.J. Low-picomolar analysis of peptides by on-line coupling of fritless solid-phase extraction to sheathless capillary electrophoresis-mass spectrometry. J. Chromatogr. A 2014, 1328:1-6.
    • (2014) J. Chromatogr. A , vol.1328 , pp. 1-6
    • Medina-Casanellas, S.1    Domínguez-Vega, E.2    Benavente, F.3    Sanz-Nebot, V.4    Somsen, G.W.5    de Jong, G.J.6
  • 12
    • 84855976546 scopus 로고    scopus 로고
    • Optimization and evaluation of a sheathless capillary electrophoresis-electrospray ionization mass spectrometry platform for peptide analysis: comparison to liquid chromatography-electrospray ionization mass spectrometry
    • Faserl K., Sarg B., Kremser L., Lindner H. Optimization and evaluation of a sheathless capillary electrophoresis-electrospray ionization mass spectrometry platform for peptide analysis: comparison to liquid chromatography-electrospray ionization mass spectrometry. Anal. Chem. 2011, 83:7297-7305.
    • (2011) Anal. Chem. , vol.83 , pp. 7297-7305
    • Faserl, K.1    Sarg, B.2    Kremser, L.3    Lindner, H.4
  • 13
    • 84869453324 scopus 로고    scopus 로고
    • rd, Improving the comprehensiveness and sensitivity of sheathless capillary electrophoresis-tandem mass spectrometry for proteomic analysis
    • rd, Improving the comprehensiveness and sensitivity of sheathless capillary electrophoresis-tandem mass spectrometry for proteomic analysis. Anal. Chem. 2012, 84:8505-8513.
    • (2012) Anal. Chem. , vol.84 , pp. 8505-8513
    • Wang, Y.1    Fonslow, B.R.2    Wong, C.C.L.3    Nakorchevsky, A.4
  • 14
    • 84884400938 scopus 로고    scopus 로고
    • Comparing and combining capillary electrophoresis electrospray ionization mass spectrometry and nano-liquid chromatography electrospray ionization mass spectrometry for the characterization of post-translationally modified histones
    • Sarg B., Faserl K., Kremser L., Halfinger B., Sebastiano R., Lindner H.H. Comparing and combining capillary electrophoresis electrospray ionization mass spectrometry and nano-liquid chromatography electrospray ionization mass spectrometry for the characterization of post-translationally modified histones. Mol. Cell. Proteomics 2013, 12:2640-2656.
    • (2013) Mol. Cell. Proteomics , vol.12 , pp. 2640-2656
    • Sarg, B.1    Faserl, K.2    Kremser, L.3    Halfinger, B.4    Sebastiano, R.5    Lindner, H.H.6
  • 15
    • 84874076140 scopus 로고    scopus 로고
    • Low-flow sheathless capillary electrophoresis-mass spectrometry for sensitive glycoform profiling of intact pharmaceutical proteins
    • Haselberg R., de Jong G.J., Somsen G.W. Low-flow sheathless capillary electrophoresis-mass spectrometry for sensitive glycoform profiling of intact pharmaceutical proteins. Anal. Chem. 2013, 85:2289-2296.
    • (2013) Anal. Chem. , vol.85 , pp. 2289-2296
    • Haselberg, R.1    de Jong, G.J.2    Somsen, G.W.3
  • 16
    • 78149357330 scopus 로고    scopus 로고
    • Performance of a sheathless porous tip sprayer for capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins
    • Haselberg R., Ratnayake C.K., de Jong G.J., Somsen G.W. Performance of a sheathless porous tip sprayer for capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins. J. Chromatogr. A 2010, 1217:7605-7611.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 7605-7611
    • Haselberg, R.1    Ratnayake, C.K.2    de Jong, G.J.3    Somsen, G.W.4
  • 17
    • 77955353598 scopus 로고    scopus 로고
    • Simplified capillary electrophoresis nanospray sheath-flow interface for high efficiency and sensitive peptide analysis
    • Wojcik R., Dada O.O., Sadilek M., Dovichi N.J. Simplified capillary electrophoresis nanospray sheath-flow interface for high efficiency and sensitive peptide analysis. Rapid Commun. Mass Spectrom. 2010, 24:2554-2560.
    • (2010) Rapid Commun. Mass Spectrom. , vol.24 , pp. 2554-2560
    • Wojcik, R.1    Dada, O.O.2    Sadilek, M.3    Dovichi, N.J.4
  • 18
    • 84863010988 scopus 로고    scopus 로고
    • Capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry as an alternative proteomics platform to ultraperformance liquid chromatography-electrospray ionization-tandem mass spectrometry for samples of intermediate complexity
    • Li Y., Champion M.M., Sun L., Champion P.A., Wojcik R., Dovichi N.J. Capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry as an alternative proteomics platform to ultraperformance liquid chromatography-electrospray ionization-tandem mass spectrometry for samples of intermediate complexity. Anal. Chem. 2012, 84:1617-1622.
    • (2012) Anal. Chem. , vol.84 , pp. 1617-1622
    • Li, Y.1    Champion, M.M.2    Sun, L.3    Champion, P.A.4    Wojcik, R.5    Dovichi, N.J.6
  • 19
    • 84855939629 scopus 로고    scopus 로고
    • Capillary electrophoresis with Orbitrap-Velos mass spectrometry detection
    • Wojcik R., Li Y., Maccoss M.J., Dovichi N.J. Capillary electrophoresis with Orbitrap-Velos mass spectrometry detection. Talanta 2012, 88:324-329.
    • (2012) Talanta , vol.88 , pp. 324-329
    • Wojcik, R.1    Li, Y.2    Maccoss, M.J.3    Dovichi, N.J.4
  • 20
    • 84874622504 scopus 로고    scopus 로고
    • Single-shot proteomics using capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry with production of more than 1250 Escherichia coli peptide identifications in a 50min separation
    • Zhu G., Sun L., Yan X., Dovichi N.J. Single-shot proteomics using capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry with production of more than 1250 Escherichia coli peptide identifications in a 50min separation. Anal. Chem. 2013, 85:2569-2573.
    • (2013) Anal. Chem. , vol.85 , pp. 2569-2573
    • Zhu, G.1    Sun, L.2    Yan, X.3    Dovichi, N.J.4
  • 21
    • 84883289789 scopus 로고    scopus 로고
    • Bottom-up proteome analysis of E. coli using capillary zone electrophoresis-tandem mass spectrometry with an electrokinetic sheath-flow electrospray interface
    • Yan X., Essaka D.C., Sun L., Zhu G., Dovichi N.J. Bottom-up proteome analysis of E. coli using capillary zone electrophoresis-tandem mass spectrometry with an electrokinetic sheath-flow electrospray interface. Proteomics 2013, 13:2546-2551.
    • (2013) Proteomics , vol.13 , pp. 2546-2551
    • Yan, X.1    Essaka, D.C.2    Sun, L.3    Zhu, G.4    Dovichi, N.J.5
  • 22
    • 84892476612 scopus 로고    scopus 로고
    • Stable, reproducible, and automated capillary zone electrophoresis-tandem mass spectrometry system with an electrokinetically pumped sheath-flow nanospray interface
    • Zhu G., Sun L., Yan X., Dovichi N.J. Stable, reproducible, and automated capillary zone electrophoresis-tandem mass spectrometry system with an electrokinetically pumped sheath-flow nanospray interface. Anal. Chim. Acta 2014, 810:94-98.
    • (2014) Anal. Chim. Acta , vol.810 , pp. 94-98
    • Zhu, G.1    Sun, L.2    Yan, X.3    Dovichi, N.J.4
  • 23
    • 84867792660 scopus 로고    scopus 로고
    • CZE-ESI-MS/MS system for analysis of subnanogram amounts of tryptic digests of a cellular homogenate
    • Sun L., Zhu G., Li Y., Wojcik R., Yang P., Dovichi N.J. CZE-ESI-MS/MS system for analysis of subnanogram amounts of tryptic digests of a cellular homogenate. Proteomics 2012, 12:3013-3019.
    • (2012) Proteomics , vol.12 , pp. 3013-3019
    • Sun, L.1    Zhu, G.2    Li, Y.3    Wojcik, R.4    Yang, P.5    Dovichi, N.J.6
  • 24
    • 84876204347 scopus 로고    scopus 로고
    • Integrated capillary zone electrophoresis-electrospray ionization tandem mass spectrometry system with an immobilized trypsin microreactor for online digestion and analysis of picogram amounts of RAW 264.7 cell lysate
    • Sun L., Zhu G., Dovichi N.J. Integrated capillary zone electrophoresis-electrospray ionization tandem mass spectrometry system with an immobilized trypsin microreactor for online digestion and analysis of picogram amounts of RAW 264.7 cell lysate. Anal. Chem. 2013, 85:4187-4194.
    • (2013) Anal. Chem. , vol.85 , pp. 4187-4194
    • Sun, L.1    Zhu, G.2    Dovichi, N.J.3
  • 25
    • 84877678295 scopus 로고    scopus 로고
    • Capillary zone electrophoresis-multiple reaction monitoring from 100pg of RAW 264.7 cell lysate digest
    • Sun L., Li Y., Champion M.M., Zhu G., Wojcik R., Dovichi N.J. Capillary zone electrophoresis-multiple reaction monitoring from 100pg of RAW 264.7 cell lysate digest. Analyst 2013, 138:3181-3188.
    • (2013) Analyst , vol.138 , pp. 3181-3188
    • Sun, L.1    Li, Y.2    Champion, M.M.3    Zhu, G.4    Wojcik, R.5    Dovichi, N.J.6
  • 26
    • 84881337700 scopus 로고    scopus 로고
    • Capillary isoelectric focusing-tandem mass spectrometry and reversed-phase liquid chromatography-tandem mass spectrometry for quantitative proteomic analysis of differentiating PC12 cells by eight-plex isobaric tags for relative and absolute quantification
    • Zhu G., Sun L., Keithley R.B., Dovichi N.J. Capillary isoelectric focusing-tandem mass spectrometry and reversed-phase liquid chromatography-tandem mass spectrometry for quantitative proteomic analysis of differentiating PC12 cells by eight-plex isobaric tags for relative and absolute quantification. Anal. Chem. 2013, 85:7221-7229.
    • (2013) Anal. Chem. , vol.85 , pp. 7221-7229
    • Zhu, G.1    Sun, L.2    Keithley, R.B.3    Dovichi, N.J.4
  • 27
    • 84879241038 scopus 로고    scopus 로고
    • Fast top-down intact protein characterization with capillary zone electrophoresis-electrospray ionization tandem mass spectrometry
    • Sun L., Knierman M.D., Zhu G., Dovichi N.J. Fast top-down intact protein characterization with capillary zone electrophoresis-electrospray ionization tandem mass spectrometry. Anal. Chem. 2013, 85:5989-5995.
    • (2013) Anal. Chem. , vol.85 , pp. 5989-5995
    • Sun, L.1    Knierman, M.D.2    Zhu, G.3    Dovichi, N.J.4
  • 28
    • 84863922137 scopus 로고    scopus 로고
    • Quantitative multiple reaction monitoring of peptide abundance introduced via a capillary zone electrophoresis-electrospray interface
    • Li Y., Wojcik R., Dovichi N.J., Champion M.M. Quantitative multiple reaction monitoring of peptide abundance introduced via a capillary zone electrophoresis-electrospray interface. Anal. Chem. 2012, 84:6116-6121.
    • (2012) Anal. Chem. , vol.84 , pp. 6116-6121
    • Li, Y.1    Wojcik, R.2    Dovichi, N.J.3    Champion, M.M.4
  • 29
    • 84888309957 scopus 로고    scopus 로고
    • Accurate determination of peptide phosphorylation stoichiometry via automated diagonal capillary electrophoresis coupled with mass spectrometry: proof of principle
    • Mou S., Sun L., Dovichi N.J. Accurate determination of peptide phosphorylation stoichiometry via automated diagonal capillary electrophoresis coupled with mass spectrometry: proof of principle. Anal. Chem. 2013, 85:10692-10696.
    • (2013) Anal. Chem. , vol.85 , pp. 10692-10696
    • Mou, S.1    Sun, L.2    Dovichi, N.J.3
  • 30
    • 84890489834 scopus 로고    scopus 로고
    • Ultrasensitive and fast bottom-up analysis of femtogram amounts of complex proteome digests
    • Sun L., Zhu G., Zhao Y., Yan X., Mou S., Dovichi N.J. Ultrasensitive and fast bottom-up analysis of femtogram amounts of complex proteome digests. Angew. Chem. Int. Ed. Engl. 2013, 52:13661-13664.
    • (2013) Angew. Chem. Int. Ed. Engl. , vol.52 , pp. 13661-13664
    • Sun, L.1    Zhu, G.2    Zhao, Y.3    Yan, X.4    Mou, S.5    Dovichi, N.J.6
  • 31
    • 84898802027 scopus 로고    scopus 로고
    • Capillary electrophoresis-mass spectrometry using a flow-through microvial interface for cationic metabolome analysis
    • Lindenburg P.W., Ramautar R., Jayo R.G., Chen D.D., Hankemeier T. Capillary electrophoresis-mass spectrometry using a flow-through microvial interface for cationic metabolome analysis. Electrophoresis 2014, 35:1308-1314.
    • (2014) Electrophoresis , vol.35 , pp. 1308-1314
    • Lindenburg, P.W.1    Ramautar, R.2    Jayo, R.G.3    Chen, D.D.4    Hankemeier, T.5
  • 33
    • 81255144086 scopus 로고    scopus 로고
    • Flow-through microvial facilitating interface of capillary isoelectric focusing and electrospray ionization mass spectrometry
    • Zhong X., Maxwell E.J., Ratnayake C., Mack S., Chen D.D. Flow-through microvial facilitating interface of capillary isoelectric focusing and electrospray ionization mass spectrometry. Anal. Chem. 2011, 83:8748-8755.
    • (2011) Anal. Chem. , vol.83 , pp. 8748-8755
    • Zhong, X.1    Maxwell, E.J.2    Ratnayake, C.3    Mack, S.4    Chen, D.D.5
  • 34
    • 84881347529 scopus 로고    scopus 로고
    • Capillary isotachophoresis-nanoelectrospray ionization-selected reaction monitoring MS via a novel sheathless interface for high sensitivity sample quantification
    • Wang C., Lee C.S., Smith R.D., Tang K. Capillary isotachophoresis-nanoelectrospray ionization-selected reaction monitoring MS via a novel sheathless interface for high sensitivity sample quantification. Anal. Chem. 2013, 85:7308-7315.
    • (2013) Anal. Chem. , vol.85 , pp. 7308-7315
    • Wang, C.1    Lee, C.S.2    Smith, R.D.3    Tang, K.4
  • 35
    • 0033168122 scopus 로고    scopus 로고
    • Identification of proteins in complexes by solid-phase microextraction/multistep elution/capillary electrophoresis/tandem mass spectrometry
    • Tong W., Link A., Eng J.K., Yates J.R. Identification of proteins in complexes by solid-phase microextraction/multistep elution/capillary electrophoresis/tandem mass spectrometry. Anal. Chem. 1999, 71:2270-2278.
    • (1999) Anal. Chem. , vol.71 , pp. 2270-2278
    • Tong, W.1    Link, A.2    Eng, J.K.3    Yates, J.R.4
  • 36
    • 33645721632 scopus 로고    scopus 로고
    • Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
    • Anderson L., Hunter C.L. Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins. Mol. Cell. Proteomics 2006, 5:573-588.
    • (2006) Mol. Cell. Proteomics , vol.5 , pp. 573-588
    • Anderson, L.1    Hunter, C.L.2
  • 37
    • 84861990380 scopus 로고    scopus 로고
    • Selected reaction monitoring-based proteomics: workflows, potential, pitfalls and future directions
    • Picotti P., Aebersold R. Selected reaction monitoring-based proteomics: workflows, potential, pitfalls and future directions. Nat. Methods 2012, 9:555-566.
    • (2012) Nat. Methods , vol.9 , pp. 555-566
    • Picotti, P.1    Aebersold, R.2
  • 38
    • 1842528125 scopus 로고    scopus 로고
    • Quantification of C-reactive protein in the serum of patients with rheumatoid arthritis using multiple reaction monitoring mass spectrometry and 13C-labeled peptide standards
    • Kuhn E., Wu J., Karl J., Liao H., Zolg W., Guild B. Quantification of C-reactive protein in the serum of patients with rheumatoid arthritis using multiple reaction monitoring mass spectrometry and 13C-labeled peptide standards. Proteomics 2004, 4:1175-1186.
    • (2004) Proteomics , vol.4 , pp. 1175-1186
    • Kuhn, E.1    Wu, J.2    Karl, J.3    Liao, H.4    Zolg, W.5    Guild, B.6
  • 39
    • 54049090766 scopus 로고    scopus 로고
    • Selected reaction monitoring for quantitative proteomics: a tutorial
    • Lange V., Picotti P., Domon B., Aebersold R. Selected reaction monitoring for quantitative proteomics: a tutorial. Mol. Syst. Biol. 2008, 4:222.
    • (2008) Mol. Syst. Biol. , vol.4 , pp. 222
    • Lange, V.1    Picotti, P.2    Domon, B.3    Aebersold, R.4
  • 40
    • 84869233177 scopus 로고    scopus 로고
    • Parallel reaction monitoring for high resolution and high mass accuracy quantitative, targeted proteomics
    • Peterson A.C., Russell J.D., Bailey D.J., Westphall M.S., Coon J.J. Parallel reaction monitoring for high resolution and high mass accuracy quantitative, targeted proteomics. Mol. Cell. Proteomics 2012, 11:1475-1488.
    • (2012) Mol. Cell. Proteomics , vol.11 , pp. 1475-1488
    • Peterson, A.C.1    Russell, J.D.2    Bailey, D.J.3    Westphall, M.S.4    Coon, J.J.5
  • 41
    • 84900640884 scopus 로고    scopus 로고
    • Uncovering immobilized trypsin digestion features from large-scale proteome data generated by high-resolution mass spectrometry
    • Sun L., Zhu G., Yan X., Mou S., Dovichi N.J. Uncovering immobilized trypsin digestion features from large-scale proteome data generated by high-resolution mass spectrometry. J. Chromatogr. A 2014, 1337:40-47.
    • (2014) J. Chromatogr. A , vol.1337 , pp. 40-47
    • Sun, L.1    Zhu, G.2    Yan, X.3    Mou, S.4    Dovichi, N.J.5
  • 42
    • 0037108887 scopus 로고    scopus 로고
    • Empirical statistical model to estimate the accuracy of peptide identifications made by MS/MS and database search
    • Keller A., Nesvizhskii A.L., Kolker E., Aebersold R. Empirical statistical model to estimate the accuracy of peptide identifications made by MS/MS and database search. Anal. Chem. 2002, 74:5383-5392.
    • (2002) Anal. Chem. , vol.74 , pp. 5383-5392
    • Keller, A.1    Nesvizhskii, A.L.2    Kolker, E.3    Aebersold, R.4
  • 43
    • 33847630405 scopus 로고    scopus 로고
    • Target-decoy search strategy for increased confidence in large-scale protein identifications by mass spectrometry
    • Elias J.E., Gygi S.P. Target-decoy search strategy for increased confidence in large-scale protein identifications by mass spectrometry. Nat. Methods 2007, 4:207-214.
    • (2007) Nat. Methods , vol.4 , pp. 207-214
    • Elias, J.E.1    Gygi, S.P.2
  • 44
    • 84892651699 scopus 로고    scopus 로고
    • Picoelectrospray ionization mass spectrometry using narrow-bore chemically etched emitters
    • Marginean I., Tang K., Smith R.D., Kelly R.T. Picoelectrospray ionization mass spectrometry using narrow-bore chemically etched emitters. J. Am. Soc. Mass Spectrom. 2014, 25:30-36.
    • (2014) J. Am. Soc. Mass Spectrom. , vol.25 , pp. 30-36
    • Marginean, I.1    Tang, K.2    Smith, R.D.3    Kelly, R.T.4
  • 45
    • 84906045191 scopus 로고    scopus 로고
    • Improving the sensitivity of mass spectrometry by using a new sheath flow electrospray emitter array at subambient pressures
    • Cox J.T., Marginean I., Kelly R.T., Smith R.D., Tang K. Improving the sensitivity of mass spectrometry by using a new sheath flow electrospray emitter array at subambient pressures. J. Am. Soc. Mass Spectrom. 2014, 10.1007/s13361-014-0856-5.
    • (2014) J. Am. Soc. Mass Spectrom.
    • Cox, J.T.1    Marginean, I.2    Kelly, R.T.3    Smith, R.D.4    Tang, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.