-
1
-
-
0025232716
-
Increased efficacy of radiation therapy by use of proton beam
-
H.D. Suit, M. Goitein, and J. Munzenrider et al. Increased efficacy of radiation therapy by use of proton beam Strahlenther Onkol 166 1990 40 44
-
(1990)
Strahlenther Onkol
, vol.166
, pp. 40-44
-
-
Suit, H.D.1
Goitein, M.2
Munzenrider, J.3
-
2
-
-
34347268050
-
Current status and new developments in ion therapy
-
C.P. Karger, and O. Jakel Current status and new developments in ion therapy Strahlenther Onkol 183 2007 295 300
-
(2007)
Strahlenther Onkol
, vol.183
, pp. 295-300
-
-
Karger, C.P.1
Jakel, O.2
-
4
-
-
0032732178
-
Design and construction of a ripple filter for a smoothed depth dose distribution in conformal particle therapy
-
U. Weber, and G. Kraft Design and construction of a ripple filter for a smoothed depth dose distribution in conformal particle therapy Phys Med Biol 44 1999 2765 2775
-
(1999)
Phys Med Biol
, vol.44
, pp. 2765-2775
-
-
Weber, U.1
Kraft, G.2
-
6
-
-
34347368952
-
Energy deposition stochastics and track structure: What about the target?
-
D.T. Goodhead Energy deposition stochastics and track structure: What about the target? Radiat Prot Dosim 122 2006 3 15
-
(2006)
Radiat Prot Dosim
, vol.122
, pp. 3-15
-
-
Goodhead, D.T.1
-
7
-
-
0033775027
-
Development of radiation therapy optimization
-
A. Brahme Development of radiation therapy optimization Acta Oncol 39 2000 579 595
-
(2000)
Acta Oncol
, vol.39
, pp. 579-595
-
-
Brahme, A.1
-
9
-
-
84858040160
-
The potential impact of relative biological effectiveness uncertainty on charged particle treatment prescriptions
-
B. Jones, T.S.A. Underwood, and R.G. Dale The potential impact of relative biological effectiveness uncertainty on charged particle treatment prescriptions Br J Radiol 84 2011 61 69
-
(2011)
Br J Radiol
, vol.84
, pp. 61-69
-
-
Jones, B.1
Underwood, T.S.A.2
Dale, R.G.3
-
10
-
-
0027436629
-
Relative biological effectiveness of intermediate energy protons. Comparison with 60Co gamma-radiation using two cell lines
-
E. Blomquist, K.R. Russell, and B. Stenerlow et al. Relative biological effectiveness of intermediate energy protons. Comparison with 60Co gamma-radiation using two cell lines Radiother Oncol 28 1993 44 51
-
(1993)
Radiother Oncol
, vol.28
, pp. 44-51
-
-
Blomquist, E.1
Russell, K.R.2
Stenerlow, B.3
-
11
-
-
84890281327
-
New strategies in radiation therapy: Exploiting the full potential of protons
-
R. Mohan, A. Mahajan, and B.D. Minsky New strategies in radiation therapy: Exploiting the full potential of protons Clin Cancer Res 19 2013 6338 6343
-
(2013)
Clin Cancer Res
, vol.19
, pp. 6338-6343
-
-
Mohan, R.1
Mahajan, A.2
Minsky, B.D.3
-
12
-
-
0005391430
-
Inactivation of human normal and tumour cells irradiated with low energy protons
-
M. Belli, D. Bettega, and P. Calzolari et al. Inactivation of human normal and tumour cells irradiated with low energy protons Int J Radiat Biol 76 2000 831 839
-
(2000)
Int J Radiat Biol
, vol.76
, pp. 831-839
-
-
Belli, M.1
Bettega, D.2
Calzolari, P.3
-
13
-
-
0016833839
-
Radiobiological studies of a high-energy modulated proton beam utilizing cultured mammalian cells
-
J.B. Robertson, J.R. Williams, and R.A. Schmidt et al. Radiobiological studies of a high-energy modulated proton beam utilizing cultured mammalian cells Cancer 35 1975 1664 1677
-
(1975)
Cancer
, vol.35
, pp. 1664-1677
-
-
Robertson, J.B.1
Williams, J.R.2
Schmidt, R.A.3
-
14
-
-
0028088360
-
The depth-dependent radiation response of human melanoma cells exposed to 65-MeV protons
-
A. Courdi, N. Brassart, and J. Herault et al. The depth-dependent radiation response of human melanoma cells exposed to 65-MeV protons Br J Radiol 67 1994 800 804
-
(1994)
Br J Radiol
, vol.67
, pp. 800-804
-
-
Courdi, A.1
Brassart, N.2
Herault, J.3
-
15
-
-
0029785770
-
Measurements of relative biological effectiveness of the 70 MeV proton beam at TRIUMF using Chinese hamster V79 cells and the high-precision cell sorter assay
-
B.G. Wouters, G.K. Lam, and U. Oelfke et al. Measurements of relative biological effectiveness of the 70 MeV proton beam at TRIUMF using Chinese hamster V79 cells and the high-precision cell sorter assay Radiat Res 146 1996 159 170
-
(1996)
Radiat Res
, vol.146
, pp. 159-170
-
-
Wouters, B.G.1
Lam, G.K.2
Oelfke, U.3
-
16
-
-
78650016931
-
Application of constant vs variable relative biological effectiveness in treatment planning of intensity-modulated proton therapy
-
M.C. Frese, J.J. Wilkens, and P.E. Huber et al. Application of constant vs. variable relative biological effectiveness in treatment planning of intensity-modulated proton therapy Int J Radiat Oncol Biol Phys 79 2011 80 88
-
(2011)
Int J Radiat Oncol Biol Phys
, vol.79
, pp. 80-88
-
-
Frese, M.C.1
Wilkens, J.J.2
Huber, P.E.3
-
17
-
-
84857514306
-
Range uncertainty in proton therapy due to variable biological effectiveness
-
A. Carabe, M. Moteabbed, and N. Depauw et al. Range uncertainty in proton therapy due to variable biological effectiveness Phys Med Biol 57 2012 1159 1172
-
(2012)
Phys Med Biol
, vol.57
, pp. 1159-1172
-
-
Carabe, A.1
Moteabbed, M.2
Depauw, N.3
-
18
-
-
84872046853
-
Impact of variable RBE on proton fractionation
-
A. Dasu Impact of variable RBE on proton fractionation Med Phys 40 2013 11705 11714
-
(2013)
Med Phys
, vol.40
, pp. 11705-11714
-
-
Dasu, A.1
-
19
-
-
77956606102
-
Dose and LET-painting with particle therapy
-
N. Bassler, O. Jäke, and C.S. Søndergaard et al. Dose and LET-painting with particle therapy Acta Oncol 49 2010 1170 1176
-
(2010)
Acta Oncol
, vol.49
, pp. 1170-1176
-
-
Bassler, N.1
Jäke, O.2
Søndergaard, C.S.3
-
20
-
-
84877766275
-
Systematic analysis of RBE and related quantities using a database of cell survival experiments with ion beam irradiation
-
T. Friedrich, U. Scholz, and T. ElsäSser et al. Systematic analysis of RBE and related quantities using a database of cell survival experiments with ion beam irradiation J Radiat Res 54 2013 494 514
-
(2013)
J Radiat Res
, vol.54
, pp. 494-514
-
-
Friedrich, T.1
Scholz, U.2
Elsässer, T.3
-
21
-
-
77956285946
-
Response of radio resistant human melanoma cell line along the proton spread out Bragg peak
-
I. Petrovic, A. Ristic-Fira, and D. Todrovic et al. Response of radio resistant human melanoma cell line along the proton spread out Bragg peak Int J Radiat Biol 86 2010 742 751
-
(2010)
Int J Radiat Biol
, vol.86
, pp. 742-751
-
-
Petrovic, I.1
Ristic-Fira, A.2
Todrovic, D.3
-
22
-
-
84872119582
-
Variations in the RBE for cell killing along the depth dose profile of a modulated proton therapy beam
-
R.A. Britten, V. Nazaryan, and K.L. Davis et al. Variations in the RBE for cell killing along the depth dose profile of a modulated proton therapy beam Radiat Res 179 2013 21 28
-
(2013)
Radiat Res
, vol.179
, pp. 21-28
-
-
Britten, R.A.1
Nazaryan, V.2
Davis, K.L.3
-
23
-
-
84905911204
-
A 62-MeV proton beam for the treatment of ocular melanoma at Laboratori Nazionali del Sud-INFN
-
Cirrone GAP, Cuttone G, Lojacono PA, et al. A 62-MeV proton beam for the treatment of ocular melanoma at Laboratori Nazionali del Sud-INFN. IEEE Transactions on Nuclear Science, http://dx.doi.org/10.1109/NSSMIC.2003.1352701
-
IEEE Transactions on Nuclear Science
-
-
Cirrone, G.A.P.1
Cuttone, G.2
Lojacono, P.A.3
-
25
-
-
33645544810
-
Rapid calculation of biological effects in ion radiotherapy
-
M. Krämer, and M. Scholz Rapid calculation of biological effects in ion radiotherapy Phys Med Biol 51 2006 1959 1970
-
(2006)
Phys Med Biol
, vol.51
, pp. 1959-1970
-
-
Krämer, M.1
Scholz, M.2
-
26
-
-
0034255597
-
Relative biological effectiveness for cell-killing effect on various human cell lines irradiated with heavy-ion medical accelerator in Chiba (HIMAC) carbon-ion beams
-
M. Suzuki, Y. Kase, and H. Yamaguchi et al. Relative biological effectiveness for cell-killing effect on various human cell lines irradiated with heavy-ion medical accelerator in Chiba (HIMAC) carbon-ion beams Int J Radiat Oncol 48 2000 241 250
-
(2000)
Int J Radiat Oncol
, vol.48
, pp. 241-250
-
-
Suzuki, M.1
Kase, Y.2
Yamaguchi, H.3
-
27
-
-
44449155178
-
Accuracy of the local effect model for the prediction of biologic effects of carbon ion beams in vitro and in vivo
-
T. Elsässer, M. Krämer, and M. Scholz Accuracy of the local effect model for the prediction of biologic effects of carbon ion beams in vitro and in vivo Int J Radiat Oncol Biol Phys 71 2008 866 872
-
(2008)
Int J Radiat Oncol Biol Phys
, vol.71
, pp. 866-872
-
-
Elsässer, T.1
Krämer, M.2
Scholz, M.3
-
28
-
-
1842564091
-
Three-dimensional LET calculations for treatment planning of proton therapy
-
J.J. Wilkens, and U. Oelfke Three-dimensional LET calculations for treatment planning of proton therapy Med Phys 14 2004 41 46
-
(2004)
Med Phys
, vol.14
, pp. 41-46
-
-
Wilkens, J.J.1
Oelfke, U.2
-
29
-
-
0031812136
-
A microdosimetric-kinetic theory of the dependence of the RBE for cell death on LET
-
R.B. Hawkins A microdosimetric-kinetic theory of the dependence of the RBE for cell death on LET Med Phys 25 1998 1157 1170
-
(1998)
Med Phys
, vol.25
, pp. 1157-1170
-
-
Hawkins, R.B.1
-
30
-
-
0033048040
-
The assessment of RBE effects using the concept of biologically effective dose
-
R.G. Dale, and B. Jones The assessment of RBE effects using the concept of biologically effective dose Int J Radiat Oncol Biol Phys 43 1999 639 645
-
(1999)
Int J Radiat Oncol Biol Phys
, vol.43
, pp. 639-645
-
-
Dale, R.G.1
Jones, B.2
-
31
-
-
84858050182
-
Fast neutron relative biological effects and implications for charged particle therapy
-
B. Jones, T.S. Underwood, and A. Carabe-Fernandez et al. Fast neutron relative biological effects and implications for charged particle therapy Br J Radiol 84 2011 S11 S18
-
(2011)
Br J Radiol
, vol.84
-
-
Jones, B.1
Underwood, T.S.2
Carabe-Fernandez, A.3
-
32
-
-
0032945625
-
Relative biological effectiveness of proton beams in clinical therapy
-
L.E. Gerweck, and S.V. Kozin Relative biological effectiveness of proton beams in clinical therapy Radiother Oncol 50 1999 135 142
-
(1999)
Radiother Oncol
, vol.50
, pp. 135-142
-
-
Gerweck, L.E.1
Kozin, S.V.2
|