Pump-induced haemolysis: A comparison of short-term ventricular assist devices
-
DOI 10.1191/0267659104pf729oa
-
Bennett M, Horton S, Thuys C, Augustin S, Rosenberg M, Brizard C. Pump-induced haemolysis: a comparison of short-term ventricular assist devices. Perfusion. 2004 ; 19: 107-111 (Pubitemid 38607513)
-
(2004)
Perfusion
, vol.19
, Issue.2
, pp. 107-111
-
-
Bennett, M.1
Horton, S.2
Thuys, C.3
Augustin, S.4
Rosenberg, M.5
Brizard, C.6
-
3
-
-
24944567494
-
Hemolytic characteristics of three commercially available centrifugal blood pumps
-
DOI 10.1097/01.PCC.0000163282.63992.13
-
Lawson S, Ing R, Cheifetz I, et al. Hemolytic characteristics of three commercially available centrifugal blood pumps. Pediatric Critical Care Medicine. 2005 ; 6: 573-577 (Pubitemid 41306761)
-
(2005)
Pediatric Critical Care Medicine
, vol.6
, Issue.5
, pp. 573-577
-
-
Lawson, D.S.1
Ing, R.2
Cheifetz, I.M.3
Walczak, R.4
Craig, D.5
Schulman, S.6
Kern, F.7
Shearer, I.R.8
Lodge, A.9
Jaggers, J.10
-
4
-
-
79960361877
-
Levitronix centrimag third-generation magnetically levitated continuous flow pump as bridge to solution
-
Loforte A, Montalto A, Ranocchi F, et al. Levitronix centrimag third-generation magnetically levitated continuous flow pump as bridge to solution. ASAIO J. 2011 ; 57: 247-253
-
(2011)
ASAIO J
, vol.57
, pp. 247-253
-
-
Loforte, A.1
Montalto, A.2
Ranocchi, F.3
-
5
-
-
0033938026
-
Blood pumps for circulatory support
-
Reul H, Akidis M. Blood pumps for circulatory support. Perfusion. 2000 ; 15: 295-311 (Pubitemid 30438707)
-
(2000)
Perfusion
, vol.15
, Issue.4
, pp. 295-311
-
-
Reul, H.M.1
Akdis, M.2
-
6
-
-
84874439878
-
Hemolysis and free hemoglobin revisited: Exploring hemoglobin and hemin scavengers as a novel class of theraputic proteins
-
Schaer D, Buehler P, Alayash A, et al. Hemolysis and free hemoglobin revisited: exploring hemoglobin and hemin scavengers as a novel class of theraputic proteins. Blood. 2013 ; 121: 1276-1284
-
(2013)
Blood
, vol.121
, pp. 1276-1284
-
-
Schaer, D.1
Buehler, P.2
Alayash, A.3
-
7
-
-
79952985548
-
Outcomes of a multicenter trial of the Levitronix CentriMag ventricular assist system for short-term circulatory support
-
John R, Long J, Massey T, et al. Outcomes of a multicenter trial of the Levitronix CentriMag ventricular assist system for short-term circulatory support. J Thorac Cardiovasc Surg. 2011 ; 141: 932-939
-
(2011)
J Thorac Cardiovasc Surg
, vol.141
, pp. 932-939
-
-
John, R.1
Long, J.2
Massey, T.3
-
8
-
-
34447629868
-
Experience with the Levitronix CentriMag circulatory support system as a bridge to decision in patients with refractory acute cardiogenic shock and multisystem organ failure
-
DOI 10.1016/j.jtcvs.2007.01.085, PII S0022522307006186
-
John R, Liao K, Lietz K, et al. Experience with the Levitronix CentriMag circulatory support system as a bridge to decision in patients with refractory acute cardiogenic shock and multisystem organ failure. J Thorac Cardiovasc Surg. 2007 ; 134: 351-358 (Pubitemid 47088583)
-
(2007)
Journal of Thoracic and Cardiovascular Surgery
, vol.134
, Issue.2
, pp. 351-358
-
-
John, R.1
Liao, K.2
Lietz, K.3
Kamdar, F.4
Colvin-Adams, M.5
Boyle, A.6
Miller, L.7
Joyce, L.8
-
9
-
-
38949212989
-
The Papworth Experience With the Levitronix CentriMag Ventricular Assist Device
-
DOI 10.1016/j.healun.2007.10.015, PII S1053249807008339
-
Shuhaiber JH, Jenkins D, Berman M, et al. The Papworth experience with the Levitronix Centrimag ventricular assist device. J Heart Lung Transplant. 2008 ; 27: 158-164 (Pubitemid 351222639)
-
(2008)
Journal of Heart and Lung Transplantation
, vol.27
, Issue.2
, pp. 158-164
-
-
Shuhaiber, J.H.1
Jenkins, D.2
Berman, M.3
Parameshwar, J.4
Dhital, K.5
Tsui, S.6
Large, S.R.7
-
10
-
-
31544443524
-
Clinical performance with the Levitronix Centrimag short-term ventricular assist device
-
DOI 10.1016/j.healun.2005.08.019, PII S1053249805005656
-
De Robertis F, Birks EJ, Rogers P, et al. Clinical performance with the Levitronix Centrimag short-term ventricular assist device. J Heart Lung Transplant. 2006 ; 25: 181-186 (Pubitemid 43156369)
-
(2006)
Journal of Heart and Lung Transplantation
, vol.25
, Issue.2
, pp. 181-186
-
-
De Robertis, F.1
Birks, E.J.2
Rogers, P.3
Dreyfus, G.4
Pepper, J.R.5
Khaghani, A.6
-
11
-
-
33646124494
-
Levitronix as a short-term salvage treatment for primary graft failure after heart transplantation
-
Santise G, Petrou M, Pepper JR, et al. Levitronix as a short-term salvage treatment for primary graft failure after heart transplantation. J Heart Lung Transplant. 2006 ; 25: 495-498
-
(2006)
J Heart Lung Transplant
, vol.25
, pp. 495-498
-
-
Santise, G.1
Petrou, M.2
Pepper, J.R.3
-
12
-
-
42649142928
-
Bridge to Decision Using the Levitronix CentriMag Short-term Ventricular Assist Device
-
DOI 10.1016/j.healun.2008.01.027, PII S1053249808001083
-
De Robertis F, Rogers P, Amrani M, et al. Bridge to decision using the Levitronix Centrimag short-term ventricular assist device. J Heart Lung Transplant. 2008 ; 27: 474-478 (Pubitemid 351602178)
-
(2008)
Journal of Heart and Lung Transplantation
, vol.27
, Issue.5
, pp. 474-478
-
-
De Robertis, F.1
Rogers, P.2
Amrani, M.3
Petrou, M.4
Pepper, J.R.5
Bahrami, T.6
Dreyfus, G.D.7
Khaghani, A.8
Birks, E.J.9
-
13
-
-
62449193864
-
A hemodynamic evaluation of the Levitronix Pedivas centrifugal pump and Jostra HL-20 roller pump under pulsatile and nonpulsatile perfusion in an infant CPB model
-
Ressler N, Rider A, Kunselman A, et al. A hemodynamic evaluation of the Levitronix Pedivas centrifugal pump and Jostra HL-20 roller pump under pulsatile and nonpulsatile perfusion in an infant CPB model. ASAIO J. 2009 ; 55: 106-110
-
(2009)
ASAIO J
, vol.55
, pp. 106-110
-
-
Ressler, N.1
Rider, A.2
Kunselman, A.3
-
14
-
-
68949214352
-
Clinical experience using the Levitronix Centrimag system for temporary right ventricular mechanical circulatory support
-
Bhama J, Kormos R, Toyoda Y, et al. Clinical experience using the Levitronix Centrimag system for temporary right ventricular mechanical circulatory support. J Heart Lung Transplant. 2009 ; 28: 971-976
-
(2009)
J Heart Lung Transplant
, vol.28
, pp. 971-976
-
-
Bhama, J.1
Kormos, R.2
Toyoda, Y.3
-
15
-
-
33644993283
-
Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the Centrimag blood pump
-
Zhang J, Gellman B, Koert A, et al. Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the Centrimag blood pump. Artificial Organs. 2006 ; 30: 168-177
-
(2006)
Artificial Organs
, vol.30
, pp. 168-177
-
-
Zhang, J.1
Gellman, B.2
Koert, A.3
-
16
-
-
84940310017
-
-
Levitronix Technologies accessed June 2013
-
Levitronix Technologies. Bearingless pump technology. http://www.levitronix.com/en/Bearingless-Pumps.html (2010, accessed June 2013)
-
(2010)
Bearingless Pump Technology
-
-
-
18
-
-
1642407635
-
Experience with the Jostra Rotaflow and QuadroxD oxygenator for ECMO
-
DOI 10.1191/0267659104pf702oa
-
Horton S, Thuys C, Bennett M, Augustin S, Rosenberg M, Brizard C. Experience with the Jostra Rotaflow and QuadroxD oxygenator for ECMO. Perfusion. 2004 ; 19: 17-23 (Pubitemid 38386645)
-
(2004)
Perfusion
, vol.19
, Issue.1
, pp. 17-23
-
-
Horton, S.1
Thuys, C.2
Bennett, M.3
Augustin, S.4
Rosenberg, M.5
Brizard, C.6
-
20
-
-
0034827967
-
Development of the MEDOS/HIA DeltaStream extracorporeal rotary blood pump
-
DOI 10.1046/j.1525-1594.2001.025005358.x
-
Gobel C, Arvand A, Eilers R, et al. Development of the MEDOS/HIA DeltaStream extracorporeal rotary blood pump. Artificial Organs. 2001 ; 25: 358-365 (Pubitemid 32830464)
-
(2001)
Artificial Organs
, vol.25
, Issue.5
, pp. 358-365
-
-
Gobel, C.1
Arvand, A.2
Eilers, R.3
Marseille, O.4
Bals, C.5
Meyns, B.6
Flameng, W.7
Rau, G.8
Reul, H.9
-
22
-
-
73949087368
-
Comparison of two different minimized extracorporeal circulation systems: Hematological effects after coronary surgery
-
Haneya A, Philipp A, Diez C. Comparison of two different minimized extracorporeal circulation systems: hematological effects after coronary surgery. ASAIO J. 2009 ; 55: 592-597
-
(2009)
ASAIO J
, vol.55
, pp. 592-597
-
-
Haneya, A.1
Philipp, A.2
Diez, C.3
-
23
-
-
84871392445
-
Axial and centrifugal continuous-flow rotary pumps: A translation from pump mechanics to clinical practice
-
Moazami N, Fukamachi K, Kobayashi M, et al. Axial and centrifugal continuous-flow rotary pumps: a translation from pump mechanics to clinical practice. J Heart and Lung Transplant. 2013 ; 32: 1-11
-
(2013)
J Heart and Lung Transplant
, vol.32
, pp. 1-11
-
-
Moazami, N.1
Fukamachi, K.2
Kobayashi, M.3
-
26
-
-
69849113902
-
A survey in mathematics for industry. A review of computational fluid dynamics analysis of blood pumps
-
Behbahani M, Behr M, Hormes M, et al. A survey in mathematics for industry. A review of computational fluid dynamics analysis of blood pumps. Euro J Applied Mathematics. 2009 ; 20: 363-397
-
(2009)
Euro J Applied Mathematics
, vol.20
, pp. 363-397
-
-
Behbahani, M.1
Behr, M.2
Hormes, M.3
-
27
-
-
77952203682
-
Computational fluid dynamics analysis of blade tip clearances on hemodynamic performance and blood damage in a centrifugal ventricular assist device
-
Wu J, Paden B, Borovetz H, et al. Computational fluid dynamics analysis of blade tip clearances on hemodynamic performance and blood damage in a centrifugal ventricular assist device. Artificial Organs. 2009 ; 34: 402-411
-
(2009)
Artificial Organs
, vol.34
, pp. 402-411
-
-
Wu, J.1
Paden, B.2
Borovetz, H.3
-
28
-
-
15444375607
-
Comparison of hydraulic and hemolytic properties of different impeller designs of an implantable rotary blood pump by computational fluid dynamics
-
DOI 10.1111/j.1525-1594.2004.07379.x
-
Arvand A, Hahn N, Hormes M, et al. Comparison of hydraulic and hemolytic properties of different impeller designs of an implantable rotary blood pump by computational fluid dynamics. Artificial Organs. 2004 ; 28: 892-898 (Pubitemid 40394470)
-
(2004)
Artificial Organs
, vol.28
, Issue.10
, pp. 892-898
-
-
Arvand, A.1
Hahn, N.2
Hormes, M.3
Akdis, M.4
Martin, M.5
Reul, H.6
-
29
-
-
33646239626
-
Computational fluid dynamics analysis of the pediatric tiny centrifugal blood pump
-
Kido K, Hoshi H, Watanabe N, et al. Computational fluid dynamics analysis of the pediatric tiny centrifugal blood pump. Artificial Organs. 2006 ; 30: 392-399
-
(2006)
Artificial Organs
, vol.30
, pp. 392-399
-
-
Kido, K.1
Hoshi, H.2
Watanabe, N.3
-
30
-
-
34247611066
-
Deformability of red blood cells and its relation to blood trauma in rotary blood pumps
-
DOI 10.1111/j.1525-1594.2007.00392.x
-
Watanabe N, Sakota D, Ohuchi K, et al. Deformability of red blood cells and its relation to blood trauma in rotary blood pumps. Artificial Organs. 2007 ; 31: 352-358 (Pubitemid 46669024)
-
(2007)
Artificial Organs
, vol.31
, Issue.5
, pp. 352-358
-
-
Watanabe, N.1
Sakota, D.2
Ohuchi, K.3
Takatani, S.4
|