메뉴 건너뛰기




Volumn 34, Issue 5, 2009, Pages 436-440

Low profile pelvic fixation: Anatomic parameters for sacral alar-iliac fixation versus traditional iliac fixation

Author keywords

CT reconstruction; Pelvic obliquity; S2 iliac pathway; Scoliosis

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; CHILD; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FEMALE; FRACTURE FIXATION; HUMAN; ILIAC BONE; INTERMETHOD COMPARISON; MALE; PRIORITY JOURNAL; SCHOOL CHILD; SPINE MALFORMATION; BONE SCREW; COMPARATIVE STUDY; HISTOLOGY; INSTRUMENTATION; LUMBAR VERTEBRA; METHODOLOGY; PATHOLOGY; PREOPERATIVE CARE; RADIOGRAPHY; RETROSPECTIVE STUDY; SACRUM; SPINE; SPINE DISEASE; SPINE FUSION; VERTEBRA;

EID: 65549171537     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e318194128c     Document Type: Article
Times cited : (230)

References (14)
  • 1
    • 0023933559 scopus 로고
    • The Galveston experience with L-rod instrumentation for adolescent idiopathic scoliosis
    • Allen BL Jr, Ferguson RL. The Galveston experience with L-rod instrumentation for adolescent idiopathic scoliosis. Clin Orthop Relat Res 1988;229:59 - 69.
    • (1988) Clin Orthop Relat Res , vol.229 , pp. 59-69
    • Allen Jr, B.L.1    Ferguson, R.L.2
  • 3
    • 0032775257 scopus 로고    scopus 로고
    • Management of neuromuscular scoliosis
    • McCarthy RE. Management of neuromuscular scoliosis. Orthop Clin North Am 1999;30:435-49.
    • (1999) Orthop Clin North Am , vol.30 , pp. 435-449
    • McCarthy, R.E.1
  • 4
    • 0021136386 scopus 로고
    • The Galveston technique of pelvic fixation with L-rod instrumentation of the spine
    • Allen BL Jr, Ferguson RL. The Galveston technique of pelvic fixation with L-rod instrumentation of the spine. Spine 1984;9:388-94.
    • (1984) Spine , vol.9 , pp. 388-394
    • Allen Jr, B.L.1    Ferguson, R.L.2
  • 5
    • 2942637328 scopus 로고    scopus 로고
    • Biomechanical assessment of conventional unit rod fixation versus a unit rod pedicle screw construct. A human cadaver study
    • Erickson MA, Oliver T, Baldini T, et al. Biomechanical assessment of conventional unit rod fixation versus a unit rod pedicle screw construct. A human cadaver study. Spine 2004;29:1314-9.
    • (2004) Spine , vol.29 , pp. 1314-1319
    • Erickson, M.A.1    Oliver, T.2    Baldini, T.3
  • 6
    • 0036843974 scopus 로고    scopus 로고
    • Biomechanical comparison of lumbosacral fixation techniques in a calf spine model
    • Lebwohl NH, Cunningham BW, Dmitriev A, et al. Biomechanical comparison of lumbosacral fixation techniques in a calf spine model. Spine 2002;27: 2312-20.
    • (2002) Spine , vol.27 , pp. 2312-2320
    • Lebwohl, N.H.1    Cunningham, B.W.2    Dmitriev, A.3
  • 7
    • 0035885144 scopus 로고    scopus 로고
    • Minimum 2-year analysis of sacro-pelvic fixation and L5-S1 fusion using S1 and iliac screws
    • Kuklo TR, Bridwell KH, Lewis SJ, et al. Minimum 2-year analysis of sacro-pelvic fixation and L5-S1 fusion using S1 and iliac screws. Spine 2001;26: 1976-83.
    • (2001) Spine , vol.26 , pp. 1976-1983
    • Kuklo, T.R.1    Bridwell, K.H.2    Lewis, S.J.3
  • 8
    • 0037444162 scopus 로고    scopus 로고
    • The pylon concept of pelvic anchorage for spinal instrumentation in the human cadaver
    • Schwend RM, Sluyters R, Najdzionek J. The pylon concept of pelvic anchorage for spinal instrumentation in the human cadaver. Spine 2003;28:542-7.
    • (2003) Spine , vol.28 , pp. 542-547
    • Schwend, R.M.1    Sluyters, R.2    Najdzionek, J.3
  • 9
    • 0024547514 scopus 로고
    • Segmental spinal instrumentation for neuromuscular spinal deformity
    • Stevens DB, Beard C. Segmental spinal instrumentation for neuromuscular spinal deformity. Clin Orthop Relat Res 1989;242:164-8.
    • (1989) Clin Orthop Relat Res , vol.242 , pp. 164-168
    • Stevens, D.B.1    Beard, C.2
  • 10
    • 33748873446 scopus 로고    scopus 로고
    • Comparison of pelvic fixation techniques in neuromuscular spinal deformity correction: Galveston rod versus iliac and lumbosacral screws
    • Peelle MW, Lenke LG, Bridwell KH, et al. Comparison of pelvic fixation techniques in neuromuscular spinal deformity correction: Galveston rod versus iliac and lumbosacral screws. Spine 2006;31:2392-8.
    • (2006) Spine , vol.31 , pp. 2392-2398
    • Peelle, M.W.1    Lenke, L.G.2    Bridwell, K.H.3
  • 11
    • 0026662036 scopus 로고
    • Biomechanical analysis of lumbosacral fixation
    • McCord DH, Cunningham BW, Shono Y, et al. Biomechanical analysis of lumbosacral fixation. Spine 1992;17:S235-S243.
    • (1992) Spine , vol.17
    • McCord, D.H.1    Cunningham, B.W.2    Shono, Y.3
  • 12
    • 0033035333 scopus 로고    scopus 로고
    • The 'MW' sacropelvic construct: An enhanced fixation of the lumbosacral junction in neuromuscular pelvic obliquity
    • Arlet V, Marchesi D, Papin P, et al. The 'MW' sacropelvic construct: an enhanced fixation of the lumbosacral junction in neuromuscular pelvic obliquity. Eur Spine J 1999;8:229-31.
    • (1999) Eur Spine J , vol.8 , pp. 229-231
    • Arlet, V.1    Marchesi, D.2    Papin, P.3
  • 13
    • 33947313318 scopus 로고    scopus 로고
    • MW construct in fusion for neuromuscular scoliosis
    • Carroll EA, Shilt JS, Jacks L. MW construct in fusion for neuromuscular scoliosis. Eur Spine J 2007;16:373-7.
    • (2007) Eur Spine J , vol.16 , pp. 373-377
    • Carroll, E.A.1    Shilt, J.S.2    Jacks, L.3
  • 14
    • 67650307792 scopus 로고    scopus 로고
    • Does iliac crest bone graft harvest affect iliac screw fixation-an in-vitro biomechanical study?
    • Paper presented at: September 7, Buenos Aires, Argentina
    • Linville D II, Cunningham BW, Dmitriev A. Does iliac crest bone graft harvest affect iliac screw fixation-an in-vitro biomechanical study? Paper presented at: The Scoliosis Research Society 39th Annual Meeting; September 7, 2004; Buenos Aires, Argentina.
    • (2004) The Scoliosis Research Society 39th Annual Meeting
    • Linville II, D.1    Cunningham, B.W.2    Dmitriev, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.