메뉴 건너뛰기




Volumn 2, Issue 4, 2014, Pages 323-330

Body Position and Activity, But Not Heart Rate, Affect Pump Flows in Patients With Continuous-Flow Left Ventricular Assist Devices

Author keywords

Exercise; Heart rate; LVAD; Posture; Tilt table

Indexed keywords

ADULT; AGED; AORTA VALVE; ARTICLE; BODY POSITION; BODY SIZE; CARDIOVASCULAR PARAMETERS; CLINICAL ARTICLE; CONTINUOUS FLOW LEFT VENTRICULAR ASSIST DEVICE; FEMALE; HEART EJECTION FRACTION; HEART PACING; HEART PRELOAD; HEART RATE; HUMAN; MALE; MEAN ARTERIAL PRESSURE; MIDDLE AGED; PHYSICAL ACTIVITY; PRIORITY JOURNAL; PROSPECTIVE STUDY; PUMP FLOW; TILT TABLE TEST; VENOUS RETURN; ARTERIAL PRESSURE; BLOOD FLOW VELOCITY; BODY POSTURE; CARDIOMYOPATHIES; EXERCISE; HEART ASSIST DEVICE; HEART RIGHT VENTRICLE FUNCTION; PATHOPHYSIOLOGY; PHYSIOLOGY; PROCEDURES;

EID: 84905494561     PISSN: 22131779     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jchf.2014.02.008     Document Type: Article
Times cited : (37)

References (24)
  • 2
    • 84863195802 scopus 로고    scopus 로고
    • Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation
    • Aaronson K.D., Slaughter M.S., Miller L.W., et al. Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation. Circulation 2012, 125:3191-3200.
    • (2012) Circulation , vol.125 , pp. 3191-3200
    • Aaronson, K.D.1    Slaughter, M.S.2    Miller, L.W.3
  • 3
    • 84860820973 scopus 로고    scopus 로고
    • Outcomes in advanced heart failure patients with left ventricular assist devices for destination therapy
    • Park S.J., Milano C.A., Tatooles A.J., et al. Outcomes in advanced heart failure patients with left ventricular assist devices for destination therapy. Circ Heart Fail 2012, 5:241-248.
    • (2012) Circ Heart Fail , vol.5 , pp. 241-248
    • Park, S.J.1    Milano, C.A.2    Tatooles, A.J.3
  • 4
    • 67650093608 scopus 로고    scopus 로고
    • Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device
    • Pagani F.D., Miller L.W., Russell S.D., et al. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol 2009, 54:312-321.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 312-321
    • Pagani, F.D.1    Miller, L.W.2    Russell, S.D.3
  • 5
    • 73349129701 scopus 로고    scopus 로고
    • Advanced heart failure treated with continuous-flow left ventricular assist device
    • Slaughter M.S., Rogers J.G., Milano C.A., et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 2009, 361:2241-2251.
    • (2009) N Engl J Med , vol.361 , pp. 2241-2251
    • Slaughter, M.S.1    Rogers, J.G.2    Milano, C.A.3
  • 6
    • 84871981956 scopus 로고    scopus 로고
    • The evolution of ventricular assist devices and the HeartWare ventricular assist system
    • Hayward C.S., Swartz M. The evolution of ventricular assist devices and the HeartWare ventricular assist system. Eur Cardiol 2012, 8:32-35.
    • (2012) Eur Cardiol , vol.8 , pp. 32-35
    • Hayward, C.S.1    Swartz, M.2
  • 7
    • 80455176895 scopus 로고    scopus 로고
    • Effect of alteration in pump speed on pump output and left ventricular filling with continuous-flow left ventricular assist device
    • Hayward C.S., Salamonsen R., Keogh A.M., et al. Effect of alteration in pump speed on pump output and left ventricular filling with continuous-flow left ventricular assist device. ASAIO J 2011, 57:495-500.
    • (2011) ASAIO J , vol.57 , pp. 495-500
    • Hayward, C.S.1    Salamonsen, R.2    Keogh, A.M.3
  • 8
    • 77949491740 scopus 로고    scopus 로고
    • Clinical management of continuous-flow left ventricular assist devices in advanced heart failure
    • Slaughter M.S., Pagani F.D., Rogers J.G., et al. Clinical management of continuous-flow left ventricular assist devices in advanced heart failure. J Heart Lung Transplant 2010, 29(Suppl):S1-S39.
    • (2010) J Heart Lung Transplant , vol.29 , Issue.SUPPL.
    • Slaughter, M.S.1    Pagani, F.D.2    Rogers, J.G.3
  • 10
    • 84856379721 scopus 로고    scopus 로고
    • Central and peripheral blood flow during exercise with a continuous-flow left ventricular assist device: constant versus increasing pump speed: a pilot study
    • Brassard P., Jensen A.S., Nordsborg N., et al. Central and peripheral blood flow during exercise with a continuous-flow left ventricular assist device: constant versus increasing pump speed: a pilot study. Circ Heart Fail 2011, 4:554-560.
    • (2011) Circ Heart Fail , vol.4 , pp. 554-560
    • Brassard, P.1    Jensen, A.S.2    Nordsborg, N.3
  • 11
    • 77956623472 scopus 로고    scopus 로고
    • Hemodynamic stress echocardiography in patients supported with a continuous-flow left ventricular assist device
    • Andersen M., Gustafsson F., Madsen P.L., et al. Hemodynamic stress echocardiography in patients supported with a continuous-flow left ventricular assist device. J Am Coll Cardiol Img 2010, 3:854-859.
    • (2010) J Am Coll Cardiol Img , vol.3 , pp. 854-859
    • Andersen, M.1    Gustafsson, F.2    Madsen, P.L.3
  • 12
    • 77953120950 scopus 로고    scopus 로고
    • Comparison of cardiac power output and exercise performance in patients with left ventricular assist devices, explanted (recovered) patients, and those with moderate to severe heart failure
    • Jakovljevic D.G., George R.S., Donovan G., et al. Comparison of cardiac power output and exercise performance in patients with left ventricular assist devices, explanted (recovered) patients, and those with moderate to severe heart failure. Am J Cardiol 2010, 105:1780-1785.
    • (2010) Am J Cardiol , vol.105 , pp. 1780-1785
    • Jakovljevic, D.G.1    George, R.S.2    Donovan, G.3
  • 13
    • 0032838992 scopus 로고    scopus 로고
    • Rotary blood pump flow spontaneously increases during exercise under constant pump speed: results of a chronic study
    • Akimoto T., Yamazaki K., Litwak P., et al. Rotary blood pump flow spontaneously increases during exercise under constant pump speed: results of a chronic study. Artif Organs 1999, 23:797-801.
    • (1999) Artif Organs , vol.23 , pp. 797-801
    • Akimoto, T.1    Yamazaki, K.2    Litwak, P.3
  • 14
    • 84881613573 scopus 로고    scopus 로고
    • Exercise studies in patients with rotary blood pumps: cause, effects, and implications for starling-like control of changes in pump flow
    • Salamonsen R.F., Pellegrino V., Fraser J.F., et al. Exercise studies in patients with rotary blood pumps: cause, effects, and implications for starling-like control of changes in pump flow. Artif Organs 2013, 37:695-703.
    • (2013) Artif Organs , vol.37 , pp. 695-703
    • Salamonsen, R.F.1    Pellegrino, V.2    Fraser, J.F.3
  • 15
    • 84905485065 scopus 로고    scopus 로고
    • Effect of concomitant speed increase with exercise on invasively measured haemodynamics in patients with continuous flow left ventricular assist devices (LVADs)
    • Muthiah K., Robson D., Pritchard R., et al. Effect of concomitant speed increase with exercise on invasively measured haemodynamics in patients with continuous flow left ventricular assist devices (LVADs). Heart Lung Circ 2012, 21(Suppl 1):S79.
    • (2012) Heart Lung Circ , vol.21 , Issue.SUPPL. 1
    • Muthiah, K.1    Robson, D.2    Pritchard, R.3
  • 16
    • 84875124249 scopus 로고    scopus 로고
    • Interaction between physical activity and continuous-flow left ventricular assist device function in outpatients
    • Hu S.X., Keogh A.M., Macdonald P.S., et al. Interaction between physical activity and continuous-flow left ventricular assist device function in outpatients. J Card Fail 2013, 19:169-175.
    • (2013) J Card Fail , vol.19 , pp. 169-175
    • Hu, S.X.1    Keogh, A.M.2    Macdonald, P.S.3
  • 17
    • 0019982539 scopus 로고
    • Decreased catecholamine sensitivity and beta-adrenergic-receptor density in failing human hearts
    • Bristow M.R., Ginsburg R., Minobe W., et al. Decreased catecholamine sensitivity and beta-adrenergic-receptor density in failing human hearts. N Engl J Med 1982, 307:205-211.
    • (1982) N Engl J Med , vol.307 , pp. 205-211
    • Bristow, M.R.1    Ginsburg, R.2    Minobe, W.3
  • 18
    • 33845542345 scopus 로고    scopus 로고
    • Mechanisms of sympathetic activation in heart failure
    • Watson A.M., Hood S.G., May C.N. Mechanisms of sympathetic activation in heart failure. Clin Exp Pharmacol Physiol 2006, 33:1269-1274.
    • (2006) Clin Exp Pharmacol Physiol , vol.33 , pp. 1269-1274
    • Watson, A.M.1    Hood, S.G.2    May, C.N.3
  • 19
    • 0033535129 scopus 로고    scopus 로고
    • Sympathetic activation in heart failure and its treatment with beta-blockade
    • Pepper G.S., Lee R.W. Sympathetic activation in heart failure and its treatment with beta-blockade. Arch Intern Med 1999, 159:225-234.
    • (1999) Arch Intern Med , vol.159 , pp. 225-234
    • Pepper, G.S.1    Lee, R.W.2
  • 20
    • 0028114888 scopus 로고
    • Vagally mediated heart rate recovery after exercise is accelerated in athletes but blunted in patients with chronic heart failure
    • Imai K., Sato H., Hori M., et al. Vagally mediated heart rate recovery after exercise is accelerated in athletes but blunted in patients with chronic heart failure. J Am Coll Cardiol 1994, 24:1529-1535.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 1529-1535
    • Imai, K.1    Sato, H.2    Hori, M.3
  • 21
    • 0024347775 scopus 로고
    • Impaired chronotropic response to exercise in patients with congestive heart failure. Role of postsynaptic beta-adrenergic desensitization
    • Colucci W.S., Ribeiro J.P., Rocco M.B., et al. Impaired chronotropic response to exercise in patients with congestive heart failure. Role of postsynaptic beta-adrenergic desensitization. Circulation 1989, 80:314-323.
    • (1989) Circulation , vol.80 , pp. 314-323
    • Colucci, W.S.1    Ribeiro, J.P.2    Rocco, M.B.3
  • 22
    • 84858177090 scopus 로고    scopus 로고
    • Chronotropic incompetence and functional capacity in chronic heart failure: no role of beta-blockers and beta-blocker dose
    • Magri D., Palermo P., Cauti F.M., et al. Chronotropic incompetence and functional capacity in chronic heart failure: no role of beta-blockers and beta-blocker dose. Cardiovasc Ther 2012, 30:100-108.
    • (2012) Cardiovasc Ther , vol.30 , pp. 100-108
    • Magri, D.1    Palermo, P.2    Cauti, F.M.3
  • 23
    • 83555172432 scopus 로고    scopus 로고
    • Chronotropic incompetence and abnormal heart rate recovery early after left ventricular assist device implantation
    • Dimopoulos S., Diakos N., Tseliou E., et al. Chronotropic incompetence and abnormal heart rate recovery early after left ventricular assist device implantation. Pacing Clin Electrophysiol 2011, 34:1607-1614.
    • (2011) Pacing Clin Electrophysiol , vol.34 , pp. 1607-1614
    • Dimopoulos, S.1    Diakos, N.2    Tseliou, E.3
  • 24
    • 84877271579 scopus 로고    scopus 로고
    • Magnitude and time course of changes induced by continuous-flow left ventricular assist device unloading in chronic heart failure: insights into cardiac recovery
    • Drakos S.G., Wever-Pinzon O., Selzman C.H., et al. Magnitude and time course of changes induced by continuous-flow left ventricular assist device unloading in chronic heart failure: insights into cardiac recovery. J Am Coll Cardiol 2013, 61:1985-1994.
    • (2013) J Am Coll Cardiol , vol.61 , pp. 1985-1994
    • Drakos, S.G.1    Wever-Pinzon, O.2    Selzman, C.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.