메뉴 건너뛰기




Volumn 6, Issue 16, 2014, Pages 6247-6253

Colorimetric detection of mercury based on a strip sensor

Author keywords

[No Author keywords available]

Indexed keywords

ANTIGEN-ANTIBODY REACTIONS; ANTIGENS;

EID: 84905189996     PISSN: 17599660     EISSN: 17599679     Source Type: Journal    
DOI: 10.1039/c3ay42002g     Document Type: Article
Times cited : (48)

References (43)
  • 1
    • 53549109430 scopus 로고    scopus 로고
    • Tools and tactics for the optical detection of mercuric ion
    • E. M. Nolan S. J. Lippard Tools and tactics for the optical detection of mercuric ion Chem. Rev. 2008 108 3443 3480
    • (2008) Chem. Rev. , vol.108 , pp. 3443-3480
    • Nolan, E.M.1    Lippard, S.J.2
  • 3
    • 33745875006 scopus 로고    scopus 로고
    • Overview of the clinical toxicity of mercury
    • L. Magos T. W. Clarkson Overview of the clinical toxicity of mercury Ann. Clin. Biochem. 2006 43 257 268
    • (2006) Ann. Clin. Biochem. , vol.43 , pp. 257-268
    • Magos, L.1    Clarkson, T.W.2
  • 4
    • 84862778934 scopus 로고    scopus 로고
    • Determination and speciation of mercury in environmental and biological samples by analytical atomic spectrometry
    • Y. Gao Z. Shi Z. Long P. Wu C. Zheng X. Hou Determination and speciation of mercury in environmental and biological samples by analytical atomic spectrometry Microchem. J. 2012 103 1 14
    • (2012) Microchem. J. , vol.103 , pp. 1-14
    • Gao, Y.1    Shi, Z.2    Long, Z.3    Wu, P.4    Zheng, C.5    Hou, X.6
  • 5
    • 75749132339 scopus 로고    scopus 로고
    • Evaluation of a new electrolytic cold vapor generation system for mercury determination by AFS
    • W. B. Zhang Z. F. Su X. F. Chu X. A. Yang Evaluation of a new electrolytic cold vapor generation system for mercury determination by AFS Talanta 2010 80 2106 2112
    • (2010) Talanta , vol.80 , pp. 2106-2112
    • Zhang, W.B.1    Su, Z.F.2    Chu, X.F.3    Yang, X.A.4
  • 6
    • 78649297379 scopus 로고    scopus 로고
    • Magnetic solid phase microextraction on a microchip combined with electrothermal vaporization-inductively coupled plasma mass spectrometry for determination of Cd, Hg and Pb in cells
    • B. Chen S. Heng H. Peng B. Hu X. Yu Z. Zhang D. Pang X. Yue Y. Zhu Magnetic solid phase microextraction on a microchip combined with electrothermal vaporization-inductively coupled plasma mass spectrometry for determination of Cd, Hg and Pb in cells J. Anal. At. Spectrom. 2010 25 1931 1938
    • (2010) J. Anal. At. Spectrom. , vol.25 , pp. 1931-1938
    • Chen, B.1    Heng, S.2    Peng, H.3    Hu, B.4    Yu, X.5    Zhang, Z.6    Pang, D.7    Yue, X.8    Zhu, Y.9
  • 7
    • 84878053535 scopus 로고    scopus 로고
    • Colorimetric Detection of Mercury Ion Based on Plasmonic Nanoparticles
    • J. Du L. Jiang Q. Shao X. Liu R. S. Marks J. Ma X. Chen Colorimetric Detection of Mercury Ion Based on Plasmonic Nanoparticles Small 2013 9 1467 1481
    • (2013) Small , vol.9 , pp. 1467-1481
    • Du, J.1    Jiang, L.2    Shao, Q.3    Liu, X.4    Marks, R.S.5    Ma, J.6    Chen, X.7
  • 8
    • 84877673638 scopus 로고    scopus 로고
    • A SERS active gold nanostar dimer for mercury ion detection
    • W. Ma M. Sun L. Xu L. Wang H. Kuang C. Xu A SERS active gold nanostar dimer for mercury ion detection Chem. Commun. 2013 49 4989 4991
    • (2013) Chem. Commun. , vol.49 , pp. 4989-4991
    • Ma, W.1    Sun, M.2    Xu, L.3    Wang, L.4    Kuang, H.5    Xu, C.6
  • 9
    • 84873622552 scopus 로고    scopus 로고
    • Monitoring the presence of ionic mercury in environmental water by plasmon-enhanced infrared spectroscopy
    • C. V. Hoang M. Oyama O. Saito M. Aono T. Nagao Monitoring the presence of ionic mercury in environmental water by plasmon-enhanced infrared spectroscopy Sci. Rep. 2013 3 1175 1180
    • (2013) Sci. Rep. , vol.3 , pp. 1175-1180
    • Hoang, C.V.1    Oyama, M.2    Saito, O.3    Aono, M.4    Nagao, T.5
  • 11
    • 84862266539 scopus 로고    scopus 로고
    • Visual and on-site detection of mercury(ii) ions on lateral flow strips using DNA-functionalized gold nanoparticles
    • F. Yang J. Duan M. Li Z. Wang Z. Guo Visual and on-site detection of mercury(ii) ions on lateral flow strips using DNA-functionalized gold nanoparticles Anal. Sci. 2012 28 333 338
    • (2012) Anal. Sci. , vol.28 , pp. 333-338
    • Yang, F.1    Duan, J.2    Li, M.3    Wang, Z.4    Guo, Z.5
  • 12
    • 35048868774 scopus 로고    scopus 로고
    • Rational design of turn-on allosteric DNAzyme catalytic beacons for aqueous mercury ions with ultrahigh sensitivity and selectivity
    • J. Liu Y. Lu Rational design of "turn-on" allosteric DNAzyme catalytic beacons for aqueous mercury ions with ultrahigh sensitivity and selectivity Angew. Chem., Int. Ed. 2007 46 7587 7590
    • (2007) Angew. Chem., Int. Ed. , vol.46 , pp. 7587-7590
    • Liu, J.1    Lu, Y.2
  • 13
    • 84870931649 scopus 로고    scopus 로고
    • Sub-ppm quantification of Hg(ii) in aqueous media using both the naked eye and digital information from pictures of a colorimetric sensory polymer membrane taken with the digital camera of a conventional mobile phone
    • H. El Kaoutit P. Estévez F. C. García F. Serna J. M. García Sub-ppm quantification of Hg(ii) in aqueous media using both the naked eye and digital information from pictures of a colorimetric sensory polymer membrane taken with the digital camera of a conventional mobile phone Anal. Methods 2013 5 54 58
    • (2013) Anal. Methods , vol.5 , pp. 54-58
    • El Kaoutit, H.1    Estévez, P.2    García, F.C.3    Serna, F.4    García, J.M.5
  • 14
    • 79957798539 scopus 로고    scopus 로고
    • A simple and cost-effective sensing strategy of mercury(ii) based on analyte-inhibited aggregation of gold nanoparticles
    • X. Yang H. Liu J. Xu X. Tang H. Huang D. Tian A simple and cost-effective sensing strategy of mercury(ii) based on analyte-inhibited aggregation of gold nanoparticles Nanotechnology 2011 22 275503 275508
    • (2011) Nanotechnology , vol.22 , pp. 275503-275508
    • Yang, X.1    Liu, H.2    Xu, J.3    Tang, X.4    Huang, H.5    Tian, D.6
  • 15
    • 77953359384 scopus 로고    scopus 로고
    • A competitive immunochromatographic assay based on a novel probe for the detection of mercury(ii) ions in water samples
    • Y. Zhou Y. Zhang F. Pan Y. Li S. Lu H. Ren Q. Shen Z. Li J. Zhang Q. Chen A competitive immunochromatographic assay based on a novel probe for the detection of mercury(ii) ions in water samples Biosens. Bioelectron. 2010 25 2534 2538
    • (2010) Biosens. Bioelectron. , vol.25 , pp. 2534-2538
    • Zhou, Y.1    Zhang, Y.2    Pan, F.3    Li, Y.4    Lu, S.5    Ren, H.6    Shen, Q.7    Li, Z.8    Zhang, J.9    Chen, Q.10
  • 16
    • 84871428478 scopus 로고    scopus 로고
    • Preparation and characterization of monoclonal antibody specific for copper-chelate complex
    • F. Liu Y. Lou X. Shi H. Wang X. Zhu Preparation and characterization of monoclonal antibody specific for copper-chelate complex J. Immunol. Methods 2013 387 228 236
    • (2013) J. Immunol. Methods , vol.387 , pp. 228-236
    • Liu, F.1    Lou, Y.2    Shi, X.3    Wang, H.4    Zhu, X.5
  • 19
    • 66149110791 scopus 로고    scopus 로고
    • Monoclonal antibody to trivalent chromium chelate complex and its application to measurement of the total chromium concentration
    • K. Sasaki S. Oguma Y. Namiki N. Ohmura Monoclonal antibody to trivalent chromium chelate complex and its application to measurement of the total chromium concentration Anal. Chem. 2009 81 4005 4009
    • (2009) Anal. Chem. , vol.81 , pp. 4005-4009
    • Sasaki, K.1    Oguma, S.2    Namiki, Y.3    Ohmura, N.4
  • 20
    • 0028040055 scopus 로고
    • Enzyme Immunoassay to Determine Heavy Metals Using Antibodies to Specific Metal-EDTA Complexes: Optimization and Validation of an Immunoassay for Soluble Indium
    • P. Chakrabarti F. M. Hatcher R. C. Blake P. A. Ladd D. A. Blake Enzyme Immunoassay to Determine Heavy Metals Using Antibodies to Specific Metal-EDTA Complexes: Optimization and Validation of an Immunoassay for Soluble Indium Anal. Biochem. 1994 217 70 75
    • (1994) Anal. Biochem. , vol.217 , pp. 70-75
    • Chakrabarti, P.1    Hatcher, F.M.2    Blake, R.C.3    Ladd, P.A.4    Blake, D.A.5
  • 22
    • 80051681715 scopus 로고    scopus 로고
    • Development and validation of a competitive indirect enzyme-linked immunosorbent assay for the determination of mercury in aqueous solution
    • H. He F. Wu M. Xu S. Yang C. Sun Y. Yang Development and validation of a competitive indirect enzyme-linked immunosorbent assay for the determination of mercury in aqueous solution Anal. Methods 2011 3 1859 1864
    • (2011) Anal. Methods , vol.3 , pp. 1859-1864
    • He, H.1    Wu, F.2    Xu, M.3    Yang, S.4    Sun, C.5    Yang, Y.6
  • 23
    • 84877332085 scopus 로고    scopus 로고
    • Development of an immunochromatographic strip and its application in the simultaneous determination of Hg(ii), Cd(ii) and Pb(ii)
    • Y. Zhou Y. S. Li X. Y. Meng Y. Y. Zhang L. Yang J. H. Zhang X. R. Wang S. Y. Lu H. L. Ren Z. S. Liu Development of an immunochromatographic strip and its application in the simultaneous determination of Hg(ii), Cd(ii) and Pb(ii) Sens. Actuators, B 2013 183 303 309
    • (2013) Sens. Actuators, B , vol.183 , pp. 303-309
    • Zhou, Y.1    Li, Y.S.2    Meng, X.Y.3    Zhang, Y.Y.4    Yang, L.5    Zhang, J.H.6    Wang, X.R.7    Lu, S.Y.8    Ren, H.L.9    Liu, Z.S.10
  • 26
    • 84863777641 scopus 로고    scopus 로고
    • Highly sensitive and specific determination of mercury(ii) ion in water, food and cosmetic samples with an ELISA based on a novel monoclonal antibody
    • Y. Z. Wang H. Yang M. Pschenitza R. Niessner Y. Li D. Knopp A. P. Deng Highly sensitive and specific determination of mercury(ii) ion in water, food and cosmetic samples with an ELISA based on a novel monoclonal antibody Anal. Bioanal. Chem. 2012 403 2519 2528
    • (2012) Anal. Bioanal. Chem. , vol.403 , pp. 2519-2528
    • Wang, Y.Z.1    Yang, H.2    Pschenitza, M.3    Niessner, R.4    Li, Y.5    Knopp, D.6    Deng, A.P.7
  • 27
    • 71549142851 scopus 로고    scopus 로고
    • Hyper Sensitive Strip Test with Chemiluminescence Signal Band
    • H. S. Kim J. C. Pyun Hyper Sensitive Strip Test with Chemiluminescence Signal Band Procedia Chem. 2009 1 1043 1046
    • (2009) Procedia Chem. , vol.1 , pp. 1043-1046
    • Kim, H.S.1    Pyun, J.C.2
  • 28
    • 84455205534 scopus 로고    scopus 로고
    • Visual detection of gene mutations based on isothermal strand-displacement polymerase reaction and lateral flow strip
    • Y. He K. Zeng S. Zhang A. S. Gurung M. Baloda X. Zhang G. Liu Visual detection of gene mutations based on isothermal strand-displacement polymerase reaction and lateral flow strip Biosens. Bioelectron. 2012 31 310 315
    • (2012) Biosens. Bioelectron. , vol.31 , pp. 310-315
    • He, Y.1    Zeng, K.2    Zhang, S.3    Gurung, A.S.4    Baloda, M.5    Zhang, X.6    Liu, G.7
  • 29
    • 84879568825 scopus 로고    scopus 로고
    • Multi-component immunochromatographic assay for simultaneous detection of aflatoxin B1, ochratoxin A and zearalenone in agro-food
    • X. Li P. Li Q. Zhang R. Li W. Zhang Z. Zhang X. Ding X. Tang Multi-component immunochromatographic assay for simultaneous detection of aflatoxin B1, ochratoxin A and zearalenone in agro-food Biosens. Bioelectron. 2013 49 426 432
    • (2013) Biosens. Bioelectron. , vol.49 , pp. 426-432
    • Li, X.1    Li, P.2    Zhang, Q.3    Li, R.4    Zhang, W.5    Zhang, Z.6    Ding, X.7    Tang, X.8
  • 31
    • 0037998212 scopus 로고    scopus 로고
    • Development of an ultrarapid one-step fluorescence immunochromatographic assay system for the quantification of microcystins
    • Y. M. Kim S. W. Oh S. Y. Jeong D. J. Pyo E. Y. Choi Development of an ultrarapid one-step fluorescence immunochromatographic assay system for the quantification of microcystins Environ. Sci. Technol. 2003 37 1899 1904
    • (2003) Environ. Sci. Technol. , vol.37 , pp. 1899-1904
    • Kim, Y.M.1    Oh, S.W.2    Jeong, S.Y.3    Pyo, D.J.4    Choi, E.Y.5
  • 33
    • 84862575508 scopus 로고    scopus 로고
    • Rapid on-site determination of melamine in raw milk by an immunochromatographic strip
    • F. Sun L. Liu W. Ma C. Xu L. Wang H. Kuang Rapid on-site determination of melamine in raw milk by an immunochromatographic strip Int. J. Food Sci. Technol. 2012 47 1505 1510
    • (2012) Int. J. Food Sci. Technol. , vol.47 , pp. 1505-1510
    • Sun, F.1    Liu, L.2    Ma, W.3    Xu, C.4    Wang, L.5    Kuang, H.6
  • 35
    • 84890112046 scopus 로고    scopus 로고
    • Significantly Improved Analytical Sensitivity of Lateral Flow Immunoassays by Using Thermal Contrast
    • Z. Qin W. C. Chan D. R. Boulware T. Akkin E. K. Butler J. C. Bischof Significantly Improved Analytical Sensitivity of Lateral Flow Immunoassays by Using Thermal Contrast Angew. Chem., Int. Ed. 2012 124 4434 4437
    • (2012) Angew. Chem., Int. Ed. , vol.124 , pp. 4434-4437
    • Qin, Z.1    Chan, W.C.2    Boulware, D.R.3    Akkin, T.4    Butler, E.K.5    Bischof, J.C.6
  • 37
    • 84879509841 scopus 로고    scopus 로고
    • A novel fluorescence-quenching immunochromatographic sensor for detection of the heavy metal chromium
    • Q. Fu Y. Tang C. Shi X. Zhang J. Xiang X. Liu A novel fluorescence-quenching immunochromatographic sensor for detection of the heavy metal chromium Biosens. Bioelectron. 2013 49 399 402
    • (2013) Biosens. Bioelectron. , vol.49 , pp. 399-402
    • Fu, Q.1    Tang, Y.2    Shi, C.3    Zhang, X.4    Xiang, J.5    Liu, X.6
  • 38
    • 84862827315 scopus 로고    scopus 로고
    • A test strip platform based on DNA-functionalized gold nanoparticles for on-site detection of mercury(ii) ions
    • Z. Y. Guo J. Duan F. Yang M. Li T. T. Hao S. Wang D. Y. Wei A test strip platform based on DNA-functionalized gold nanoparticles for on-site detection of mercury(ii) ions Talanta 2012 93 49 54
    • (2012) Talanta , vol.93 , pp. 49-54
    • Guo, Z.Y.1    Duan, J.2    Yang, F.3    Li, M.4    Hao, T.T.5    Wang, S.6    Wei, D.Y.7
  • 39
    • 84875978861 scopus 로고    scopus 로고
    • Rapid and Highly Sensitive Detection of Lead Ions in Drinking Water Based on a Strip Immunosensor
    • H. Kuang C. Xing C. Hao L. Liu L. Wang C. Xu Rapid and Highly Sensitive Detection of Lead Ions in Drinking Water Based on a Strip Immunosensor Sensors 2013 13 4214 4224
    • (2013) Sensors , vol.13 , pp. 4214-4224
    • Kuang, H.1    Xing, C.2    Hao, C.3    Liu, L.4    Wang, L.5    Xu, C.6
  • 40
    • 84905192662 scopus 로고    scopus 로고
    • A highly sensitive enzyme-linked immunosorbent assay for copper(ii) determination in drinking water
    • C. Xing H. Kuang C. Hao L. Liu L. Wang C. Xu A highly sensitive enzyme-linked immunosorbent assay for copper(ii) determination in drinking water Food Agric. Immunol. 2013 1 14
    • (2013) Food Agric. Immunol. , pp. 1-14
    • Xing, C.1    Kuang, H.2    Hao, C.3    Liu, L.4    Wang, L.5    Xu, C.6
  • 41
    • 84874923464 scopus 로고    scopus 로고
    • Visual Sensor for the Detection of Trace Cu(ii) Ions using an Immunochromatographic
    • C. Xing M. Feng C. Hao L. Xu L. Wang C. Xu Visual Sensor for the Detection of Trace Cu(ii) Ions using an Immunochromatographic Immunol. Invest. 2013 42 221 234
    • (2013) Immunol. Invest. , vol.42 , pp. 221-234
    • Xing, C.1    Feng, M.2    Hao, C.3    Xu, L.4    Wang, L.5    Xu, C.6
  • 43
    • 84893781010 scopus 로고    scopus 로고
    • A silver enhanced and sensitive strip sensor for Cadmium detection
    • C. Xing H. Kuang C. Hao L. Liu L. Wang C. Xu A silver enhanced and sensitive strip sensor for Cadmium detection Food Agric. Immunol. 2014 25 287 300 Republic of China
    • (2014) Food Agric. Immunol. , vol.25 , pp. 287-300
    • Xing, C.1    Kuang, H.2    Hao, C.3    Liu, L.4    Wang, L.5    Xu, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.