메뉴 건너뛰기




Volumn 69, Issue 9, 2014, Pages 945-951

Achieving consistent image quality and overall radiation dose reduction for coronary CT angiography with body mass index-dependent tube voltage and tube current selection

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ALGORITHM; ANGIOCARDIOGRAPHY; ARTICLE; BODY MASS; CARDIAC PATIENT; CLINICAL ASSESSMENT; CLINICAL EVALUATION; CLINICAL PROTOCOL; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY; CONTROLLED STUDY; DOSE RESPONSE; DRUG DOSE REDUCTION; ELECTRIC POTENTIAL; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; NOISE MEASUREMENT; QUANTITATIVE ANALYSIS; RADIATION DOSE REDUCTION; RADIATION EXPOSURE; RADIOLOGICAL PARAMETERS; RETROSPECTIVE STUDY; SIGNAL NOISE RATIO;

EID: 84905111171     PISSN: 00099260     EISSN: 1365229X     Source Type: Journal    
DOI: 10.1016/j.crad.2014.04.016     Document Type: Article
Times cited : (8)

References (23)
  • 1
    • 0034117652 scopus 로고    scopus 로고
    • High temporal resolution for multislice helical computed tomography
    • K. Taguchi, and H. Anno High temporal resolution for multislice helical computed tomography Med Phys 27 2000 861 872
    • (2000) Med Phys , vol.27 , pp. 861-872
    • Taguchi, K.1    Anno, H.2
  • 2
    • 0036834823 scopus 로고    scopus 로고
    • Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: Influence of physiological and technical prerequisite on image quality
    • C. Herzog, N. Abolmaali, and J.O. Balzer et al. Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality Eur Radiol 12 2002 2670 2678
    • (2002) Eur Radiol , vol.12 , pp. 2670-2678
    • Herzog, C.1    Abolmaali, N.2    Balzer, J.O.3
  • 3
    • 2542596891 scopus 로고    scopus 로고
    • Pitfalls, artifacts, and remedies in multi-detector row CT coronary angiography
    • H.S. Choi, B.W. Choi, and K.O. Choe et al. Pitfalls, artifacts, and remedies in multi-detector row CT coronary angiography RadioGraphics 24 2004 787 800
    • (2004) RadioGraphics , vol.24 , pp. 787-800
    • Choi, H.S.1    Choi, B.W.2    Choe, K.O.3
  • 4
    • 33750547401 scopus 로고    scopus 로고
    • Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography
    • J. Hsieh, J. Londt, and M. Vass et al. Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography Med Phys 33 2006 4236 4248
    • (2006) Med Phys , vol.33 , pp. 4236-4248
    • Hsieh, J.1    Londt, J.2    Vass, M.3
  • 5
    • 36249002355 scopus 로고    scopus 로고
    • Radiation dose from contemporary cardiothoracic multidetector CT protocols with an anthropomorphic female phantom: Implications for cancer induction
    • L.M. Hurwitz, R.E. Reiman, and T.T. Yoshizumi et al. Radiation dose from contemporary cardiothoracic multidetector CT protocols with an anthropomorphic female phantom: implications for cancer induction Radiology 245 2007 742 750
    • (2007) Radiology , vol.245 , pp. 742-750
    • Hurwitz, L.M.1    Reiman, R.E.2    Yoshizumi, T.T.3
  • 7
    • 0036580665 scopus 로고    scopus 로고
    • Multislice helical CT of the heart with retrospective ECG gating: Reduction of radiation exposure by ECG-controlled tube current modulation
    • T.F. Jakobs, C.R. Becker, and B. Ohnesorge et al. Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation Eur Radiol 12 2002 1081 1086
    • (2002) Eur Radiol , vol.12 , pp. 1081-1086
    • Jakobs, T.F.1    Becker, C.R.2    Ohnesorge, B.3
  • 8
    • 33645562681 scopus 로고    scopus 로고
    • CT dose reduction and dose management tools: Overview of available options
    • C. McCollough, M. Bruesewitz, and J. Kofler Jr. CT dose reduction and dose management tools: overview of available options RadioGraphics 26 2006 503 512
    • (2006) RadioGraphics , vol.26 , pp. 503-512
    • McCollough, C.1    Bruesewitz, M.2    Kofler, Jr.J.3
  • 9
    • 77956825812 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction: Assessment of image noise and image quality in coronary CT angiography
    • J. Leipsic, T.M. Labounty, and B. Heilbron et al. Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography AJR Am J Roentgenol 195 2010 649 654
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 649-654
    • Leipsic, J.1    Labounty, T.M.2    Heilbron, B.3
  • 10
    • 40949165279 scopus 로고    scopus 로고
    • Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose
    • J.P. Earls, E.L. Berman, and B.A. Urban et al. Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose Radiology 246 2008 742 753
    • (2008) Radiology , vol.246 , pp. 742-753
    • Earls, J.P.1    Berman, E.L.2    Urban, B.A.3
  • 11
    • 0041343230 scopus 로고    scopus 로고
    • Detection of coronary calcifications: Feasibility of dose reduction with a body weight-adapted examination protocol
    • A.H. Mahnken, J.E. Wildberger, and J. Simon et al. Detection of coronary calcifications: feasibility of dose reduction with a body weight-adapted examination protocol AJR Am J Roentgenol 181 2003 533 538
    • (2003) AJR Am J Roentgenol , vol.181 , pp. 533-538
    • Mahnken, A.H.1    Wildberger, J.E.2    Simon, J.3
  • 12
    • 67849126794 scopus 로고    scopus 로고
    • Determinants of vessel contrast in BMI-adapted low dose CT coronary angiography with prospective ECG-triggering
    • B.A. Herzog, L. Husmann, and I. Valenta et al. Determinants of vessel contrast in BMI-adapted low dose CT coronary angiography with prospective ECG-triggering Int J Cardiovasc Imaging 25 2009 625 630
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 625-630
    • Herzog, B.A.1    Husmann, L.2    Valenta, I.3
  • 13
    • 19844367120 scopus 로고    scopus 로고
    • Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations
    • M. Das, A. Mahnken, and G. Muhlenbruch et al. Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations AJR Am J Roentgenol 184 2005 1437 1443
    • (2005) AJR Am J Roentgenol , vol.184 , pp. 1437-1443
    • Das, M.1    Mahnken, A.2    Muhlenbruch, G.3
  • 14
    • 34347226381 scopus 로고    scopus 로고
    • Uniform image quality achieved by tube current modulation using SD of attenuation in coronary CT angiography
    • G. Hur, S. Hong, and S. Kim et al. Uniform image quality achieved by tube current modulation using SD of attenuation in coronary CT angiography AJR Am J Roentgenol 189 2007 188 198
    • (2007) AJR Am J Roentgenol , vol.189 , pp. 188-198
    • Hur, G.1    Hong, S.2    Kim, S.3
  • 15
    • 73449113287 scopus 로고    scopus 로고
    • Method for automatic tube current selection for obtaining a consistent image quality and dose optimization in a cardiac multidetector CT
    • W. Qi, J. Li, and X. Du Method for automatic tube current selection for obtaining a consistent image quality and dose optimization in a cardiac multidetector CT Korean J Radiol 10 2009 568 574
    • (2009) Korean J Radiol , vol.10 , pp. 568-574
    • Qi, W.1    Li, J.2    Du, X.3
  • 16
    • 80052175729 scopus 로고    scopus 로고
    • Individualized tube current selection for 64-row cardiac CTA based on analysis of the scout view
    • J. Gao, J. Li, and J. Earls et al. Individualized tube current selection for 64-row cardiac CTA based on analysis of the scout view Eur J Radiol 79 2011 266 271
    • (2011) Eur J Radiol , vol.79 , pp. 266-271
    • Gao, J.1    Li, J.2    Earls, J.3
  • 17
    • 75349092506 scopus 로고    scopus 로고
    • Low-tube-voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm - Initial clinical experience
    • D. Marin, R.C. Nelson, and S.T. Schindera et al. Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm - initial clinical experience Radiology 254 2010 145 153
    • (2010) Radiology , vol.254 , pp. 145-153
    • Marin, D.1    Nelson, R.C.2    Schindera, S.T.3
  • 18
    • 77953872454 scopus 로고    scopus 로고
    • Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: A comparative study
    • G.M. Feuchtner, D. Jodocy, and A. Klauser et al. Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: a comparative study Eur J Radiol 75 2010 e51 e56
    • (2010) Eur J Radiol , vol.75
    • Feuchtner, G.M.1    Jodocy, D.2    Klauser, A.3
  • 19
    • 78249233337 scopus 로고    scopus 로고
    • Cardiac CT: Are we underestimating the dose? A radiation dose study utilizing the 2007 ICRP tissue weighting factors and a cardiac specific scan volume
    • O. Gosling, R. Loader, and P. Venables et al. Cardiac CT: are we underestimating the dose? A radiation dose study utilizing the 2007 ICRP tissue weighting factors and a cardiac specific scan volume Clin Radiol 65 2010 1013 1017
    • (2010) Clin Radiol , vol.65 , pp. 1013-1017
    • Gosling, O.1    Loader, R.2    Venables, P.3
  • 20
    • 67049116139 scopus 로고    scopus 로고
    • Radiation dose from cardiac computed tomography before and after implementation of radiation dose-reduction techniques
    • G.L. Raff, K.M. Chinnaiyan, and D.A. Share et al. Radiation dose from cardiac computed tomography before and after implementation of radiation dose-reduction techniques JAMA 301 2009 2340 2348
    • (2009) JAMA , vol.301 , pp. 2340-2348
    • Raff, G.L.1    Chinnaiyan, K.M.2    Share, D.A.3
  • 21
    • 0037254248 scopus 로고    scopus 로고
    • Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT
    • P. Hunold, F.M. Vogt, and A. Schmermund et al. Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT Radiology 226 2003 145 152
    • (2003) Radiology , vol.226 , pp. 145-152
    • Hunold, P.1    Vogt, F.M.2    Schmermund, A.3
  • 22
    • 24044448219 scopus 로고    scopus 로고
    • Multislice spiral computed tomography of the heart: Technique, current applications and perspective
    • A.H. Mahnken, J.E. Wildberger, and R. Koos et al. Multislice spiral computed tomography of the heart: technique, current applications and perspective Cardiovasc Intervent Radiol 28 2005 388 399
    • (2005) Cardiovasc Intervent Radiol , vol.28 , pp. 388-399
    • Mahnken, A.H.1    Wildberger, J.E.2    Koos, R.3
  • 23
    • 0036068722 scopus 로고    scopus 로고
    • Standard-dose and 50%-reduced-dose chest CT: Comparing the effect on image quality
    • S.R. Prasad, C. Wittram, and J.A. Shepard et al. Standard-dose and 50%-reduced-dose chest CT: comparing the effect on image quality AJR Am J Roentgenol 179 2002 461 465
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 461-465
    • Prasad, S.R.1    Wittram, C.2    Shepard, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.