메뉴 건너뛰기




Volumn 121, Issue 2, 2014, Pages 260-271

Intubation biomechanics: Laryngoscope force and cervical spine motion during intubation with macintosh and airtraq laryngoscopes

Author keywords

[No Author keywords available]

Indexed keywords

FENTANYL; LIDOCAINE; MIDAZOLAM; PROPOFOL; ROCURONIUM; SEVOFLURANE;

EID: 84905024039     PISSN: 00033022     EISSN: 15281175     Source Type: Journal    
DOI: 10.1097/ALN.0000000000000263     Document Type: Article
Times cited : (59)

References (34)
  • 1
    • 33744959276 scopus 로고    scopus 로고
    • Airway management in adults after cervical spine trauma
    • Crosby ET: Airway management in adults after cervical spine trauma. Anesthesiology 2006; 104:1293-318
    • (2006) Anesthesiology , vol.104 , pp. 1293-1318
    • Crosby, E.T.1
  • 2
    • 30344456681 scopus 로고    scopus 로고
    • Potential cervical spine injury and difficult airway management for emergency intubation of trauma adults in the emergency department-A systematic review
    • Ollerton JE, Parr MJ, Harrison K, Hanrahan B, Sugrue M: Potential cervical spine injury and difficult airway management for emergency intubation of trauma adults in the emergency department-A systematic review. Emerg Med J 2006; 23:3-11
    • (2006) Emerg Med J , vol.23 , pp. 3-11
    • Ollerton, J.E.1    Parr, M.J.2    Harrison, K.3    Hanrahan, B.4    Sugrue, M.5
  • 3
    • 84869839618 scopus 로고    scopus 로고
    • Eastern Association for the Surgery of Trauma: Emergency tracheal intubation immediately following traumatic injury: An Eastern Association for the Surgery of Trauma practice management guideline
    • Mayglothling J, Duane TM, Gibbs M, McCunn M, Legome E, Eastman AL, Whelan J, Shah KH; Eastern Association for the Surgery of Trauma: Emergency tracheal intubation immediately following traumatic injury: An Eastern Association for the Surgery of Trauma practice management guideline. J Trauma Acute Care Surg 2012; 73(5 suppl 4):S333-40
    • (2012) J Trauma Acute Care Surg , vol.73 SUPPL 4 , Issue.5
    • Mayglothling, J.1    Duane, T.M.2    Gibbs, M.3    McCunn, M.4    Legome, E.5    Eastman, A.L.6    Whelan, J.7    Shah, K.H.8
  • 4
    • 0030031661 scopus 로고    scopus 로고
    • Force and torque vary between laryngoscopists and laryngoscope blades
    • Hastings RH, Hon ED, Nghiem C, Wahrenbrock EA: Force and torque vary between laryngoscopists and laryngoscope blades. Anesth Analg 1996; 82:462-8
    • (1996) Anesth Analg , vol.82 , pp. 462-468
    • Hastings, R.H.1    Hon, E.D.2    Nghiem, C.3    Wahrenbrock, E.A.4
  • 5
    • 34548602041 scopus 로고    scopus 로고
    • Cervical spine movement during laryngoscopy using the Airway Scope compared with the Macintosh laryngoscope
    • Hirabayashi Y, Fujita A, Seo N, Sugimoto H: Cervical spine movement during laryngoscopy using the Airway Scope compared with the Macintosh laryngoscope. Anaesthesia 2007; 62:1050-5
    • (2007) Anaesthesia , vol.62 , pp. 1050-1055
    • Hirabayashi, Y.1    Fujita, A.2    Seo, N.3    Sugimoto, H.4
  • 6
    • 38449091187 scopus 로고    scopus 로고
    • Upper cervical spine movement during intubation: Fluoroscopic comparison of the AirWay Scope, McCoy laryngoscope, and Macintosh laryngoscope
    • Maruyama K, Yamada T, Kawakami R, Kamata T, Yokochi M, Hara K: Upper cervical spine movement during intubation: Fluoroscopic comparison of the AirWay Scope, McCoy laryngoscope, and Macintosh laryngoscope. Br J Anaesth 2008; 100:120-4
    • (2008) Br J Anaesth , vol.100 , pp. 120-124
    • Maruyama, K.1    Yamada, T.2    Kawakami, R.3    Kamata, T.4    Yokochi, M.5    Hara, K.6
  • 7
    • 43549100627 scopus 로고    scopus 로고
    • A comparison of cervical spine movement during laryngoscopy using the Airtraq or Macintosh laryngoscopes
    • Hirabayashi Y, Fujita A, Seo N, Sugimoto H: A comparison of cervical spine movement during laryngoscopy using the Airtraq or Macintosh laryngoscopes. Anaesthesia 2008; 63:635-40
    • (2008) Anaesthesia , vol.63 , pp. 635-640
    • Hirabayashi, Y.1    Fujita, A.2    Seo, N.3    Sugimoto, H.4
  • 8
    • 67650092016 scopus 로고    scopus 로고
    • Cervical spine motion: A fluoroscopic comparison of the AirTraq Laryngoscope versus the Macintosh laryngoscope
    • Turkstra TP, Pelz DM, Jones PM: Cervical spine motion: A fluoroscopic comparison of the AirTraq Laryngoscope versus the Macintosh laryngoscope. Anesthesiology 2009; 111:97-101
    • (2009) Anesthesiology , vol.111 , pp. 97-101
    • Turkstra, T.P.1    Pelz, D.M.2    Jones, P.M.3
  • 9
    • 58749108338 scopus 로고    scopus 로고
    • Manual in-line stabilization increases pressures applied by the laryngoscope blade during direct laryngoscopy and orotracheal intubation
    • Santoni BG, Hindman BJ, Puttlitz CM, Weeks JB, Johnson N, Maktabi MA, Todd MM: Manual in-line stabilization increases pressures applied by the laryngoscope blade during direct laryngoscopy and orotracheal intubation. Anesthesiology 2009; 110:24-31
    • (2009) Anesthesiology , vol.110 , pp. 24-31
    • Santoni, B.G.1    Hindman, B.J.2    Puttlitz, C.M.3    Weeks, J.B.4    Johnson, N.5    Maktabi, M.A.6    Todd, M.M.7
  • 10
    • 36448941273 scopus 로고    scopus 로고
    • Craniocervical motion during direct laryngoscopy and orotracheal intubation with the Macintosh and Miller blades: An in vivo cinefluoroscopic study
    • LeGrand SA, Hindman BJ, Dexter F, Weeks JB, Todd MM: Craniocervical motion during direct laryngoscopy and orotracheal intubation with the Macintosh and Miller blades: An in vivo cinefluoroscopic study. Anesthesiology 2007; 107:884-91
    • (2007) Anesthesiology , vol.107 , pp. 884-891
    • Legrand, S.A.1    Hindman, B.J.2    Dexter, F.3    Weeks, J.B.4    Todd, M.M.5
  • 11
    • 0028301118 scopus 로고
    • What is the best way to determine oropharyngeal classification and mandibular space length to predict difficult laryngoscopy
    • Lewis M, Keramati S, Benumof JL, Berry CC: What is the best way to determine oropharyngeal classification and mandibular space length to predict difficult laryngoscopy? Anesthesiology 1994; 81:69-75
    • (1994) Anesthesiology , vol.81 , pp. 69-75
    • Lewis, M.1    Keramati, S.2    Benumof, J.L.3    Berry, C.C.4
  • 13
    • 23044480473 scopus 로고    scopus 로고
    • Predicting difficult intubation in apparently normal patients: A meta-analysis of bedside screening test performance
    • Shiga T, Wajima Z, Inoue T, Sakamoto A: Predicting difficult intubation in apparently normal patients: A meta-analysis of bedside screening test performance. Anesthesiology 2005; 103:429-37
    • (2005) Anesthesiology , vol.103 , pp. 429-437
    • Shiga, T.1    Wajima, Z.2    Inoue, T.3    Sakamoto, A.4
  • 14
    • 0023238545 scopus 로고
    • Difficult tracheal intubation: A retrospective study
    • Samsoon GL , Young JR: Difficult tracheal intubation: A retrospective study. Anaesthesia 1987; 42:487-90
    • (1987) Anaesthesia , vol.42 , pp. 487-490
    • Samsoon, G.L.1    Young, J.R.2
  • 15
    • 0025856797 scopus 로고
    • Spinal immobilization on a flat backboard: Does it result in neutral position of the cervical spine?
    • Schriger DL, Larmon B, LeGassick T, Blinman T: Spinal immobilization on a flat backboard: Does it result in neutral position of the cervical spine? Ann Emerg Med 1991; 20:878-81
    • (1991) Ann Emerg Med , vol.20 , pp. 878-881
    • Schriger, D.L.1    Larmon, B.2    Legassick, T.3    Blinman, T.4
  • 16
    • 38349019433 scopus 로고    scopus 로고
    • Evaluation of the Airtraq and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation
    • Maharaj CH, Costello JF, Harte BH, Laffey JG: Evaluation of the Airtraq and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation. Anaesthesia 2008; 63:182-8
    • (2008) Anaesthesia , vol.63 , pp. 182-188
    • Maharaj, C.H.1    Costello, J.F.2    Harte, B.H.3    Laffey, J.G.4
  • 17
    • 61749095100 scopus 로고    scopus 로고
    • Optimising tracheal intubation success rate using the Airtraq laryngoscope
    • Dhonneur G, Abdi W, Amathieu R, Ndoko S, Tual L: Optimising tracheal intubation success rate using the Airtraq laryngoscope. Anaesthesia 2009; 64:315-9
    • (2009) Anaesthesia , vol.64 , pp. 315-319
    • Dhonneur, G.1    Abdi, W.2    Amathieu, R.3    Ndoko, S.4    Tual, L.5
  • 18
    • 0032739013 scopus 로고    scopus 로고
    • Assessment of laryngeal view: Percentage of glottic opening score vs Cormack and Lehane grading
    • Ochroch EA, Hollander JE, Kush S, Shofer FS, Levitan RM: Assessment of laryngeal view: Percentage of glottic opening score vs Cormack and Lehane grading. Can J Anaesth 1999; 46:987-90
    • (1999) Can J Anaesth , vol.46 , pp. 987-990
    • Ochroch, E.A.1    Hollander, J.E.2    Kush, S.3    Shofer, F.S.4    Levitan, R.M.5
  • 19
    • 0030018509 scopus 로고    scopus 로고
    • Cervical spine motion with direct laryngoscopy and orotracheal intubation An in vivo cinefluoroscopic study of subjects without cervical abnormality
    • Sawin PD, Todd MM, Traynelis VC, Farrell SB, Nader A, Sato Y, Clausen JD, Goel VK: Cervical spine motion with direct laryngoscopy and orotracheal intubation. An in vivo cinefluoroscopic study of subjects without cervical abnormality. Anesthesiology 1996; 85:26-36
    • (1996) Anesthesiology , vol.85 , pp. 26-36
    • Sawin, P.D.1    Todd, M.M.2    Traynelis, V.C.3    Farrell, S.B.4    Nader, A.5    Sato, Y.6    Clausen, J.D.7    Goel, V.K.8
  • 20
    • 33745803618 scopus 로고    scopus 로고
    • Laryngoscopic evaluation with the Airway Cam
    • George RB, McKeen D, Law JA: Laryngoscopic evaluation with the Airway Cam. Can J Anaesth 2006; 53:512-5
    • (2006) Can J Anaesth , vol.53 , pp. 512-515
    • George, R.B.1    McKeen, D.2    Law, J.A.3
  • 23
    • 33947102675 scopus 로고    scopus 로고
    • A simple univariate outlier identification procedure designed for large samples
    • Banerjee S, Iglewicz B: A simple univariate outlier identification procedure designed for large samples. Commun Stat Simulat 2007; 36:249-63
    • (2007) Commun Stat Simulat , vol.36 , pp. 249-263
    • Banerjee, S.1    Iglewicz, B.2
  • 24
    • 0026750659 scopus 로고
    • Forces applied during laryngoscopy and their relationship with patient characteristics Influence of height, weight, age, sex and presence of maxillary incisors
    • Bucx MJ, van Geel RT, Scheck PA, Stijnen T, Erdmann W: Forces applied during laryngoscopy and their relationship with patient characteristics. Influence of height, weight, age, sex and presence of maxillary incisors. Anaesthesia 1992; 47:601-3
    • (1992) Anaesthesia , vol.47 , pp. 601-603
    • Bucx, M.J.1    Van Geel, R.T.2    Scheck, P.A.3    Stijnen, T.4    Erdmann, W.5
  • 25
    • 0028908308 scopus 로고
    • A new device for measuring and recording the forces applied during laryngoscopy
    • McCoy EP, Austin BA, Mirakhur RK, Wong KC: A new device for measuring and recording the forces applied during laryngoscopy. Anaesthesia 1995; 50:139-43
    • (1995) Anaesthesia , vol.50 , pp. 139-143
    • McCoy, E.P.1    Austin, B.A.2    Mirakhur, R.K.3    Wong, K.C.4
  • 27
    • 38349068477 scopus 로고    scopus 로고
    • A proposed model for direct laryngoscopy and tracheal intubation
    • G reenland KB: A proposed model for direct laryngoscopy and tracheal intubation. Anaesthesia 2008; 63:156-61
    • (2008) Anaesthesia , vol.63 , pp. 156-161
    • Greenland, K.B.1
  • 28
    • 77958183534 scopus 로고    scopus 로고
    • Changes in airway configuration with different head and neck positions using magnetic resonance imaging of normal airways: A new concept with possible clinical applications
    • Greenland KB, Edwards MJ, Hutton NJ, Challis VJ, Irwin MG, Sleigh JW: Changes in airway configuration with different head and neck positions using magnetic resonance imaging of normal airways: A new concept with possible clinical applications. Br J Anaesth 2010; 105:683-90
    • (2010) Br J Anaesth , vol.105 , pp. 683-690
    • Greenland, K.B.1    Edwards, M.J.2    Hutton, N.J.3    Challis, V.J.4    Irwin, M.G.5    Sleigh, J.W.6
  • 29
    • 81255160778 scopus 로고    scopus 로고
    • Thiel-fixation preserves the non-linear load-deformation characteristic of spinal motion segments, but increases their flexibility
    • Wilke HJ, Werner K, Hussler K, Reinehr M, Böckers TM: Thiel-fixation preserves the non-linear load-deformation characteristic of spinal motion segments, but increases their flexibility. J Mech Behav Biomed Mater 2011; 4:2133-7
    • (2011) J Mech Behav Biomed Mater , vol.4 , pp. 2133-2137
    • Wilke, H.J.1    Werner, K.2    Hussler, K.3    Reinehr, M.4    Böckers, T.M.5
  • 30
    • 68849088548 scopus 로고    scopus 로고
    • Situ measurement and modeling of biomechanical response of human cadaveric soft tissues for physics-based surgical simulation
    • L im YJ, Deo D, Singh TP, Jones DB, De S: In situ measurement and modeling of biomechanical response of human cadaveric soft tissues for physics-based surgical simulation. Surg Endosc 2009; 23:1298-307
    • (2009) Surg Endosc , vol.23 , pp. 1298-1307
    • Lim, Y.J.1    Deo, D.2    Singh, T.P.3    Jones, D.B.4    De, S.5
  • 31
  • 32
    • 84880571127 scopus 로고    scopus 로고
    • A comparison of 4 airway devices on cervical spine alignment in cadaver models of global ligamentous instability at c1-2
    • Wendling AL, Tighe PJ, Conrad BP, Baslanti TO , Horodyski M, Rechtine GR: A comparison of 4 airway devices on cervical spine alignment in cadaver models of global ligamentous instability at c1-2. Anesth Analg 2013; 117:126-32
    • (2013) Anesth Analg , vol.117 , pp. 126-132
    • Wendling, A.L.1    Tighe, P.J.2    Conrad, B.P.3    Baslanti, T.O.4    Horodyski, M.5    Rechtine, G.R.6
  • 33
    • 13244271956 scopus 로고    scopus 로고
    • Three-dimensional cervical spine movement during intubation using the Macintosh and Bullard laryngoscopes, the bonfils fibrescope and the intubating laryngeal mask airway
    • Wahlen BM, Gercek E: Three-dimensional cervical spine movement during intubation using the Macintosh and Bullard laryngoscopes, the bonfils fibrescope and the intubating laryngeal mask airway. Eur J Anaesthesiol 2004; 21:907-13
    • (2004) Eur J Anaesthesiol , vol.21 , pp. 907-913
    • Wahlen, B.M.1    Gercek, E.2
  • 34
    • 0033830767 scopus 로고    scopus 로고
    • Load-displacement properties of the normal and injured lower cervical spine in vitro
    • Richter M, Wilke HJ, Kluger P, Claes L, Puhl W: L oad-displacement properties of the normal and injured lower cervical spine in vitro. Eur Spine J 2000; 9:104-8
    • (2000) Eur Spine J , vol.9 , pp. 104-108
    • Richter, M.1    Wilke, H.J.2    Kluger, P.3    Claes, L.4    Puhl, W.5