Volumn 11, Issue 8, 2014, Pages 1352-1358

Use of a discrimination algorithm to reduce inappropriate shocks with a subcutaneous implantable cardioverter-defibrillator

Author keywords

Inappropriate shock; Inappropriate therapy; Oversensing; Rhythm discrimination; Subcutaneous implantable defibrillator; Supraventricular tachyarrhythmia

Indexed keywords

ADULT; ALGORITHM; ARTICLE; ELECTROCARDIOGRAM; FAINTNESS; FEMALE; FOLLOW UP; HEART VENTRICLE TACHYCARDIA; HUMAN; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; IMPLANTATION; MAJOR CLINICAL STUDY; MALE; MIDDLE AGED; PRIORITY JOURNAL; SHOCK; SUPRAVENTRICULAR TACHYCARDIA; CARDIOVERSION; CLINICAL TRIAL; DEVICE FAILURE; ELECTROCARDIOGRAPHY; MULTICENTER STUDY; PATHOPHYSIOLOGY; PROCEDURES; PROSPECTIVE STUDY; STANDARDS; TACHYCARDIA, VENTRICULAR; TREATMENT OUTCOME;

EID: 84904992991     PISSN: 15475271     EISSN: 15563871     Source Type: Journal    
DOI: 10.1016/j.hrthm.2014.04.012     Document Type: Article
Times cited : (77)

References (22)
  • 1
    • 9844224486 scopus 로고    scopus 로고
    • A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias
    • The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators
    • The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias N Engl J Med 337 1997 1576 1583
    • (1997) N Engl J Med , vol.337 , pp. 1576-1583
  • 3
    • 0037149716 scopus 로고    scopus 로고
    • Multicenter Automatic Defibrillator Implantation Trial II Investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction
    • A.J. Moss, W. Zareba, W.J. Hall, H. Klein, D.J. Wilber, D.S. Cannom, J.P. Daubert, S.L. Higgins, M.W. Brown, and M.L. Andrews Multicenter Automatic Defibrillator Implantation Trial II Investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction N Engl J Med 346 2002 877 883
    • (2002) N Engl J Med , vol.346 , pp. 877-883
    • Moss, A.J.1    Zareba, W.2    Hall, W.J.3    Klein, H.4    Wilber, D.J.5    Cannom, D.S.6    Daubert, J.P.7    Higgins, S.L.8    Brown, M.W.9    Andrews, M.L.10
  • 4
    • 19944429413 scopus 로고    scopus 로고
    • Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure
    • G.H. Bardy, K.L. Lee, and D.B. Mark et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure N Engl J Med 352 2005 225 237
    • (2005) N Engl J Med , vol.352 , pp. 225-237
    • Bardy, G.H.1    Lee, K.L.2    Mark, D.B.3
  • 5
    • 76449116531 scopus 로고    scopus 로고
    • Evaluation of early complications related to de Novo cardioverter defibrillator implantation: Insights from the Ontario ICD database
    • D.S. Lee, A.D. Krahn, and J.S. Healey et al. Evaluation of early complications related to De Novo cardioverter defibrillator implantation: insights from the Ontario ICD database J Am Coll Cardiol 55 2010 774 782
    • (2010) J Am Coll Cardiol , vol.55 , pp. 774-782
    • Lee, D.S.1    Krahn, A.D.2    Healey, J.S.3
  • 6
    • 79952113281 scopus 로고    scopus 로고
    • Acute lead dislodgements and in-hospital mortality in patients enrolled in the National Cardiovascular Data Registry Implantable Cardioverter Defibrillator Registry
    • A. Cheng, Y. Wang, J.P. Curtis, and P.D. Varosy Acute lead dislodgements and in-hospital mortality in patients enrolled in the National Cardiovascular Data Registry Implantable Cardioverter Defibrillator Registry J Am Coll Cardiol 56 2010 1651 1656
    • (2010) J Am Coll Cardiol , vol.56 , pp. 1651-1656
    • Cheng, A.1    Wang, Y.2    Curtis, J.P.3    Varosy, P.D.4
  • 7
    • 78049506986 scopus 로고    scopus 로고
    • Complication rates associated with pacemaker or implantable cardioverter-defibrillator generator replacements and upgrade procedures: Results from the REPLACE registry
    • J.E. Poole, M.J. Gleva, and T. Mela et al. Complication rates associated with pacemaker or implantable cardioverter-defibrillator generator replacements and upgrade procedures: results from the REPLACE registry Circulation 122 2010 1553 1561
    • (2010) Circulation , vol.122 , pp. 1553-1561
    • Poole, J.E.1    Gleva, M.J.2    Mela, T.3
  • 8
    • 34248579318 scopus 로고    scopus 로고
    • Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years
    • T. Kleemann, T. Becker, K. Doenges, M. Vater, J. Senges, S. Schneider, W. Saggau, U. Weisse, and K. Seidl Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years Circulation 115 2007 2474 2480
    • (2007) Circulation , vol.115 , pp. 2474-2480
    • Kleemann, T.1    Becker, T.2    Doenges, K.3    Vater, M.4    Senges, J.5    Schneider, S.6    Saggau, W.7    Weisse, U.8    Seidl, K.9
  • 9
    • 77954191108 scopus 로고    scopus 로고
    • An entirely subcutaneous implantable cardioverter-defibrillator
    • G.H. Bardy, W.M. Smith, and M.A. Hood et al. An entirely subcutaneous implantable cardioverter-defibrillator N Engl J Med 363 2010 36 44
    • (2010) N Engl J Med , vol.363 , pp. 36-44
    • Bardy, G.H.1    Smith, W.M.2    Hood, M.A.3
  • 10
    • 84863654279 scopus 로고    scopus 로고
    • Subcutaneous implantable cardioverter defibrillator
    • C.P. Rowley, and M.R. Gold Subcutaneous implantable cardioverter defibrillator Circ Arrhythm Electrophysiol 5 2012 587 593
    • (2012) Circ Arrhythm Electrophysiol , vol.5 , pp. 587-593
    • Rowley, C.P.1    Gold, M.R.2
  • 12
    • 84860128833 scopus 로고    scopus 로고
    • Head-to-head comparison of arrhythmia discrimination performance of subcutaneous and transvenous ICD arrhythmia detection algorithms: The START study
    • M.R. Gold, D.A. Theuns, B.P. Knight, J.L. Sturdivant, R. Sanghera, K.A. Ellenbogen, M.A. Wood, and M.C. Burke Head-to-head comparison of arrhythmia discrimination performance of subcutaneous and transvenous ICD arrhythmia detection algorithms: the START study J Cardiovasc Electrophysiol 23 2011 359 366
    • (2011) J Cardiovasc Electrophysiol , vol.23 , pp. 359-366
    • Gold, M.R.1    Theuns, D.A.2    Knight, B.P.3    Sturdivant, J.L.4    Sanghera, R.5    Ellenbogen, K.A.6    Wood, M.A.7    Burke, M.C.8
  • 14
    • 7744220529 scopus 로고    scopus 로고
    • ASTRID Investigators. Randomized controlled study of detection enhancements versus rate-only detection to prevent inappropriate therapy in a dual-chamber implantable cardioverter-defibrillator
    • P. Dorian, F. Philippon, B. Thibault, S. Kimber, L. Sterns, M. Greene, D. Newman, R. Gelaznikas, and A. Barr ASTRID Investigators. Randomized controlled study of detection enhancements versus rate-only detection to prevent inappropriate therapy in a dual-chamber implantable cardioverter-defibrillator Heart Rhythm 1 2004 540 547
    • (2004) Heart Rhythm , vol.1 , pp. 540-547
    • Dorian, P.1    Philippon, F.2    Thibault, B.3    Kimber, S.4    Sterns, L.5    Greene, M.6    Newman, D.7    Gelaznikas, R.8    Barr, A.9
  • 15
    • 7544220287 scopus 로고    scopus 로고
    • PainFREE Rx II Investigators. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter- defibrillators: Acing fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) Trial results
    • M.S. Wathen, P.J. DeGroot, M.O. Sweeney, A.J. Stark, M.F. Otterness, W.O. Adkisson, R.C. Canby, K. Khalighi, C. Machado, D.S. Rubenstein, and K.J. Volosin PainFREE Rx II Investigators. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter- defibrillators: acing fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) Trial results Circulation 110 2004 2591 2596
    • (2004) Circulation , vol.110 , pp. 2591-2596
    • Wathen, M.S.1    Degroot, P.J.2    Sweeney, M.O.3    Stark, A.J.4    Otterness, M.F.5    Adkisson, W.O.6    Canby, R.C.7    Khalighi, K.8    MacHado, C.9    Rubenstein, D.S.10    Volosin, K.J.11
  • 16
    • 48449088263 scopus 로고    scopus 로고
    • Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: Results from the PREPARE (Primary Prevention Parameters Evaluation) study
    • B.L. Wilkoff, B.D. Williamson, and R.S. Stern et al. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study J Am Coll Cardiol 52 2008 541 550
    • (2008) J Am Coll Cardiol , vol.52 , pp. 541-550
    • Wilkoff, B.L.1    Williamson, B.D.2    Stern, R.S.3
  • 17
    • 66649134745 scopus 로고    scopus 로고
    • Avoid delivering therapies for nonsustained fast ventricular tachyarrhythmia in patients with implantable cardioverter/defibrillator: The ADVANCE III Trial
    • J.O.M. Schwab, M. Gasparini, and M. Lunati et al. Avoid delivering therapies for nonsustained fast ventricular tachyarrhythmia in patients with implantable cardioverter/defibrillator: the ADVANCE III Trial J Cardiovasc Electrophysiol 20 2009 663 666
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 663-666
    • Schwab, J.O.M.1    Gasparini, M.2    Lunati, M.3
  • 18
    • 84871065661 scopus 로고    scopus 로고
    • Reduction in inappropriate therapy and mortality through ICD programming
    • A.J. Moss, C. Schuger, and C.A. Beck et al. Reduction in inappropriate therapy and mortality through ICD programming N Engl J Med 367 2012 2275 2283
    • (2012) N Engl J Med , vol.367 , pp. 2275-2283
    • Moss, A.J.1    Schuger, C.2    Beck, C.A.3
  • 19
    • 84877289895 scopus 로고    scopus 로고
    • Effect of long-detection interval vs standard-detection interval for implantable cardioverter-defibrillators on antitachycardia pacing and shock delivery:: The ADVANCE III randomized clinical trial
    • M. Gasparini, A. Proclemer, C. Klersy, A. Kloppe, M. Lunati, J.B. Ferrer, A. Hersi, M. Gulaj, M.C. Wijfels, E. Santi, L. Manotta, and A. Arenal Effect of long-detection interval vs standard-detection interval for implantable cardioverter-defibrillators on antitachycardia pacing and shock delivery:: the ADVANCE III randomized clinical trial JAMA 309 2013 1903 1911
    • (2013) JAMA , vol.309 , pp. 1903-1911
    • Gasparini, M.1    Proclemer, A.2    Klersy, C.3    Kloppe, A.4    Lunati, M.5    Ferrer, J.B.6    Hersi, A.7    Gulaj, M.8    Wijfels, M.C.9    Santi, E.10    Manotta, L.11    Arenal, A.12
  • 20
    • 84881176560 scopus 로고    scopus 로고
    • Optimal programming of implantable cardiac-defibrillators
    • M. Madhan, and P.A. Friedman Optimal programming of implantable cardiac-defibrillators Circulation 128 2013 659 672
    • (2013) Circulation , vol.128 , pp. 659-672
    • Madhan, M.1    Friedman, P.A.2
  • 21
    • 84880949197 scopus 로고    scopus 로고
    • United Kingdom national experience of entirely subcutaneous implantable cardioverter defibrillator technology: Important lessons to learn
    • J.W.E. Jarman, and D.W. Todd United Kingdom national experience of entirely subcutaneous implantable cardioverter defibrillator technology: important lessons to learn Europace 15 2013 1158 1165
    • (2013) Europace , vol.15 , pp. 1158-1165
    • Jarman, J.W.E.1    Todd, D.W.2
  • 22
    • 84903955123 scopus 로고    scopus 로고
    • Worldwide experience with a totally subcutaneous implantable defibrillator: Early results from the EFFORTLESS S-ICD Registry
    • Mar 26[Epub ahead of print]
    • P.D. Lambiase, C. Barr, and D.A.M.J. Theuns et al. Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD Registry Eur Heart J 2014 Mar 26[Epub ahead of print]
    • (2014) Eur Heart J
    • Lambiase, P.D.1    Barr, C.2    Theuns, D.A.M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.