메뉴 건너뛰기




Volumn 22, Issue 1 II, 1999, Pages 179-182

A new defibrillator discrimination algorithm utilizing electrogram morphology analysis

Author keywords

Atrial fibrillation implantable cardioverter defibrillator; Detection

Indexed keywords

ALGORITHM; ARTICLE; CLINICAL ARTICLE; DEFIBRILLATOR; ELECTROGRAPHY; HEART SUPRAVENTRICULAR ARRHYTHMIA; HUMAN;

EID: 0032953057     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1999.tb00328.x     Document Type: Article
Times cited : (39)

References (9)
  • 1
    • 0028941056 scopus 로고
    • Programmable VT detection enhancements in implantable cardioverter defibrillator therapy
    • Neuzner J, Pitschner HF, Schlepper M. Programmable VT detection enhancements in implantable cardioverter defibrillator therapy. PACE 1995; 18:539-547.
    • (1995) PACE , vol.18 , pp. 539-547
    • Neuzner, J.1    Pitschner, H.F.2    Schlepper, M.3
  • 2
    • 0028074708 scopus 로고
    • Underdetection of ventricular tachycardia by algorithms to enhance specificity in a tiered therapy cardioverter defibrillator
    • Swerdlow C, Ahern T, Chen PS, et al. Underdetection of ventricular tachycardia by algorithms to enhance specificity in a tiered therapy cardioverter defibrillator. J Am Coll Cardiol 1994; 24:416-24.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 416-424
    • Swerdlow, C.1    Ahern, T.2    Chen, P.S.3
  • 3
    • 0031916560 scopus 로고    scopus 로고
    • Enhanced detection criteria in implantable defibrillators
    • Brugada J, Mont L, Figueriedo M, et al. Enhanced detection criteria in implantable defibrillators. J Cardiovasc Electrophysiol 1998; 9:261-268.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 261-268
    • Brugada, J.1    Mont, L.2    Figueriedo, M.3
  • 4
    • 0030581450 scopus 로고    scopus 로고
    • Enhanced detection criteria in implantable cardioverter-defibrillators to avoid inappropriate therapy
    • Schaumann A, Muhlen F, Gonska BD, et al. Enhanced Detection criteria in implantable cardioverter-defibrillators to avoid inappropriate therapy. Am J Cardiol 1996; 78:42-50.
    • (1996) Am J Cardiol , vol.78 , pp. 42-50
    • Schaumann, A.1    Muhlen, F.2    Gonska, B.D.3
  • 5
    • 0029620281 scopus 로고
    • Stability: An ICD detection criterion for discriminating atrial fibrillation from ventricular tachycardia
    • Higgins SL, Lee RS, Kramer R. Stability: An ICD detection criterion for discriminating atrial fibrillation from ventricular tachycardia. J Cardiovasc Electrophysiol 1995; 6:1081-1088.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 1081-1088
    • Higgins, S.L.1    Lee, R.S.2    Kramer, R.3
  • 6
    • 0345608959 scopus 로고    scopus 로고
    • New detection enhancement for arrhythmia classification with a pectoral dual-chamber implantable cardioverter defibrillator
    • Jung W, Spehl S, Esmailzadeb B, et al. New detection enhancement for arrhythmia classification with a pectoral dual-chamber implantable cardioverter defibrillator. (abstract) PACE 1997; 20:1168.
    • (1997) PACE , vol.20 , pp. 1168
    • Jung, W.1    Spehl, S.2    Esmailzadeb, B.3
  • 7
    • 0028806445 scopus 로고
    • Benefits and lessons learned from stored electrogram information in implantable defibrillators
    • Marchlinski FE, Callans DJ, Gottlieb CD, et al. Benefits and lessons learned from stored electrogram information in implantable defibrillators. J Cardiovasc Electrophysiol 1995; 6:832-851.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 832-851
    • Marchlinski, F.E.1    Callans, D.J.2    Gottlieb, C.D.3
  • 8
    • 0030717468 scopus 로고    scopus 로고
    • Lead system optimization for transvenous defibrillation
    • Gold MR, Foster AH, Shorofsky SR. Lead system optimization for transvenous defibrillation. Am J Cardiol 1997; 80:1163-1167
    • (1997) Am J Cardiol , vol.80 , pp. 1163-1167
    • Gold, M.R.1    Foster, A.H.2    Shorofsky, S.R.3
  • 9
    • 0025788298 scopus 로고
    • Accuracy of rhythm classification using a data log system in implantable cardioverter defibrillators
    • Wang PJ, Mandalakas N, Clyne C. Accuracy of rhythm classification using a data log system in implantable cardioverter defibrillators. PACE 1991; 14:1911-1916.
    • (1991) PACE , vol.14 , pp. 1911-1916
    • Wang, P.J.1    Mandalakas, N.2    Clyne, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.