-
1
-
-
0001418140
-
Synthesis of substrate-selective polymers by host-guest polymerization
-
R. Arshady, and K. Mosbach Synthesis of substrate-selective polymers by host-guest polymerization Macromol. Chem. 182 1981 687 692
-
(1981)
Macromol. Chem.
, vol.182
, pp. 687-692
-
-
Arshady, R.1
Mosbach, K.2
-
2
-
-
0000146718
-
Enzyme-analogue built polymers and their use for the resolution of racemates
-
G. Wulff, A. Sarhan, and K. Zabrocki Enzyme-analogue built polymers and their use for the resolution of racemates Tetrahedron Lett. 14 1973 4329 4332
-
(1973)
Tetrahedron Lett.
, vol.14
, pp. 4329-4332
-
-
Wulff, G.1
Sarhan, A.2
Zabrocki, K.3
-
3
-
-
0036025402
-
Enzyme-like catalysis by molecularly imprinted polymers
-
G. Wulff Enzyme-like catalysis by molecularly imprinted polymers Chem. Rev. 102 2002 1 27
-
(2002)
Chem. Rev.
, vol.102
, pp. 1-27
-
-
Wulff, G.1
-
4
-
-
0041336780
-
Molecularly imprinted polymers, the next generation
-
K. Haupt Molecularly imprinted polymers, the next generation Anal. Chem. 1 2003 376 383
-
(2003)
Anal. Chem.
, vol.1
, pp. 376-383
-
-
Haupt, K.1
-
5
-
-
0034604830
-
Molecular imprinting: Developments and applications in the analytical chemistry field
-
L.I. Andersson Molecular imprinting: developments and applications in the analytical chemistry field J. Chromatogr. B Biomed. Sci. Appl. 745 2000 3 13
-
(2000)
J. Chromatogr. B Biomed. Sci. Appl.
, vol.745
, pp. 3-13
-
-
Andersson, L.I.1
-
6
-
-
0037450936
-
Imprinted polymers: Artificial molecular recognition materials with applications in synthesis and catalysis
-
C. Alexander, L. Davidson, and W. Hayes Imprinted polymers: artificial molecular recognition materials with applications in synthesis and catalysis Tetrahedron 59 2003 2025 2057
-
(2003)
Tetrahedron
, vol.59
, pp. 2025-2057
-
-
Alexander, C.1
Davidson, L.2
Hayes, W.3
-
7
-
-
34547280157
-
Two-dimensional molecular imprinting approach to produce optical biosensor recognition elements
-
X. Li, and S.M. Husson Two-dimensional molecular imprinting approach to produce optical biosensor recognition elements Langmuir 22 2006 9658 9663
-
(2006)
Langmuir
, vol.22
, pp. 9658-9663
-
-
Li, X.1
Husson, S.M.2
-
9
-
-
0034224826
-
Molecularly imprinted polymers and their use in biomimetic sensors
-
K. Haupt, and K. Mosbach Molecularly imprinted polymers and their use in biomimetic sensors Chem. Rev. 100 2000 2495 2504
-
(2000)
Chem. Rev.
, vol.100
, pp. 2495-2504
-
-
Haupt, K.1
Mosbach, K.2
-
10
-
-
0034949249
-
Molecularly imprinted polymers in analytical chemistry
-
K. Haupt Molecularly imprinted polymers in analytical chemistry Analyst 126 2001 747 756
-
(2001)
Analyst
, vol.126
, pp. 747-756
-
-
Haupt, K.1
-
11
-
-
64449087409
-
Production of surface plasmon resonance based assay kit for hepatitis diagnosis
-
L. Uzun, R. Say, S. Ünal, and A. Denizli Production of surface plasmon resonance based assay kit for hepatitis diagnosis Biosens. Bioelectron. 24 2009 2878 2884
-
(2009)
Biosens. Bioelectron.
, vol.24
, pp. 2878-2884
-
-
Uzun, L.1
Say, R.2
Ünal, S.3
Denizli, A.4
-
12
-
-
84856499271
-
Surface imprinted thin polymer film systems with selective recognition for bovine serum albumin
-
D.R. Kryscio, and N.A. Peppas Surface imprinted thin polymer film systems with selective recognition for bovine serum albumin Anal. Chim. Acta 718 2012 109 115
-
(2012)
Anal. Chim. Acta
, vol.718
, pp. 109-115
-
-
Kryscio, D.R.1
Peppas, N.A.2
-
13
-
-
43049083390
-
Molecularly imprinted polymers with specific recognition for macromolecules and proteins
-
N. Bergmann, and N.A. Peppas Molecularly imprinted polymers with specific recognition for macromolecules and proteins Prog. Polym. Sci. 33 2008 271 288
-
(2008)
Prog. Polym. Sci.
, vol.33
, pp. 271-288
-
-
Bergmann, N.1
Peppas, N.A.2
-
14
-
-
0037173268
-
Multiprotein immunoassay arrays fabricated by microcontact imprinting
-
H.D. Inerowicz, S. Howell, F.E. Regnier, and R. Reifenberger Multiprotein immunoassay arrays fabricated by microcontact imprinting Langmuir 18 2002 5263 5268
-
(2002)
Langmuir
, vol.18
, pp. 5263-5268
-
-
Inerowicz, H.D.1
Howell, S.2
Regnier, F.E.3
Reifenberger, R.4
-
15
-
-
58849137909
-
A systematic approach to forming micro-contact imprints of creatine kinase
-
Y.W. Chen, J. Rick, and T.C. Chou A systematic approach to forming micro-contact imprints of creatine kinase Org. Biomol. Chem. 7 2009 488 494
-
(2009)
Org. Biomol. Chem.
, vol.7
, pp. 488-494
-
-
Chen, Y.W.1
Rick, J.2
Chou, T.C.3
-
16
-
-
20344369263
-
C-reactive protein thin-film molecularly imprinted polymers formed using a micro-contact approach
-
P.C. Chou C-reactive protein thin-film molecularly imprinted polymers formed using a micro-contact approach Anal. Chim. Acta 542 2005 20 25
-
(2005)
Anal. Chim. Acta
, vol.542
, pp. 20-25
-
-
Chou, P.C.1
-
17
-
-
70349453912
-
Assessing the binding selectivity of molecularly imprinted polymer artificial antibodies by mass spectrometry-based profiling system
-
P.C. Liao, Y.C. Tyan, C.Y. Wang, J.F. Hsu, T.C. Chou, and H.Y. Lin Assessing the binding selectivity of molecularly imprinted polymer artificial antibodies by mass spectrometry-based profiling system J. Biomed. Mater. Res. A 91A 2009 597 604
-
(2009)
J. Biomed. Mater. Res. A
, vol.91 A
, pp. 597-604
-
-
Liao, P.C.1
Tyan, Y.C.2
Wang, C.Y.3
Hsu, J.F.4
Chou, T.C.5
Lin, H.Y.6
-
18
-
-
33749242388
-
The microcontact imprinting of proteins: The effect of cross-linking monomers for lysozyme, ribonuclease A and myoglobin
-
H.Y. Lin, C.Y. Hsu, J.L. Thomas, S.E. Wang, H.C. Chen, and T.C. Chou The microcontact imprinting of proteins: the effect of cross-linking monomers for lysozyme, ribonuclease A and myoglobin Biosens. Bioelectron. 22 2006 534 543
-
(2006)
Biosens. Bioelectron.
, vol.22
, pp. 534-543
-
-
Lin, H.Y.1
Hsu, C.Y.2
Thomas, J.L.3
Wang, S.E.4
Chen, H.C.5
Chou, T.C.6
-
19
-
-
42249116087
-
Microcontact printed antibodies on gold surfaces: Function, uniformity and silicone contamination
-
J.O. Foley, E. Fu, L.J. Gamble, and P. Yager Microcontact printed antibodies on gold surfaces: function, uniformity and silicone contamination Langmuir 24 2008 3628 3635
-
(2008)
Langmuir
, vol.24
, pp. 3628-3635
-
-
Foley, J.O.1
Fu, E.2
Gamble, L.J.3
Yager, P.4
-
20
-
-
79954579317
-
Recent advances in molecular imprinting technology: Current status, challenges and highlighted applications
-
L. Chen, S. Xu, and J. Li Recent advances in molecular imprinting technology: current status, challenges and highlighted applications Chem. Soc. Rev. 40 2011 2922 2942
-
(2011)
Chem. Soc. Rev.
, vol.40
, pp. 2922-2942
-
-
Chen, L.1
Xu, S.2
Li, J.3
-
21
-
-
84885010701
-
Rapid real-time detection of procalcitonin using a microcontact imprinted surface plasmon resonance biosensor
-
G. Şener, E. Özgür, A.Y. Rad, L. Uzun, R. Say, and A. Denizli Rapid real-time detection of procalcitonin using a microcontact imprinted surface plasmon resonance biosensor Analyst 138 2013 6422 6428
-
(2013)
Analyst
, vol.138
, pp. 6422-6428
-
-
Şener, G.1
Özgür, E.2
Rad, A.Y.3
Uzun, L.4
Say, R.5
Denizli, A.6
-
22
-
-
84881173162
-
Microcontact imprinted surface plasmon resonance sensor for myoglobin detection
-
B. Osman, L. Uzun, N. Beşirli, and A. Denizli Microcontact imprinted surface plasmon resonance sensor for myoglobin detection Mat. Sci. Eng. C 33 2013 3609 3614
-
(2013)
Mat. Sci. Eng. C
, vol.33
, pp. 3609-3614
-
-
Osman, B.1
Uzun, L.2
Beşirli, N.3
Denizli, A.4
-
23
-
-
34248532342
-
Optimizing the formulation of a myoglobin molecularly imprinted thin-film polymer formed using a micro-contact imprinting method
-
H.Y. Lin, J. Rick, and T.C. Chou Optimizing the formulation of a myoglobin molecularly imprinted thin-film polymer formed using a micro-contact imprinting method Biosens. Bioelectron. 22 2007 3293 3301
-
(2007)
Biosens. Bioelectron.
, vol.22
, pp. 3293-3301
-
-
Lin, H.Y.1
Rick, J.2
Chou, T.C.3
-
24
-
-
31944447287
-
Synthesis of and recognition by ribonuclease A imprinted polymers
-
C.Y. Hsu, H.Y. Lin, J.L. Thomas, and T.C. Chou Synthesis of and recognition by ribonuclease A imprinted polymers Nanotechnology 17 2006 77 83
-
(2006)
Nanotechnology
, vol.17
, pp. 77-83
-
-
Hsu, C.Y.1
Lin, H.Y.2
Thomas, J.L.3
Chou, T.C.4
-
25
-
-
9244242087
-
Unconventional patterning with a modulus-tunable mold: From imprinting to microcontact imprinting
-
P.J. Yoo, S.J. Choi, J.H. Kim, D. Suh, S.J. Baek, T.W. Kim, and H.H. Lee Unconventional patterning with a modulus-tunable mold: from imprinting to microcontact imprinting Chem. Mater. 16 2004 5000 5005
-
(2004)
Chem. Mater.
, vol.16
, pp. 5000-5005
-
-
Yoo, P.J.1
Choi, S.J.2
Kim, J.H.3
Suh, D.4
Baek, S.J.5
Kim, T.W.6
Lee, H.H.7
-
27
-
-
84865447740
-
Fabrication of tunable micropatterned substrates for cell patterning via microcontact printing of polydopamine with poly (ethylene imine)-grafted copolymers
-
H.W. Chien, and W.B. Tsai Fabrication of tunable micropatterned substrates for cell patterning via microcontact printing of polydopamine with poly (ethylene imine)-grafted copolymers Acta Biomater. 8 2012 3678 3686
-
(2012)
Acta Biomater.
, vol.8
, pp. 3678-3686
-
-
Chien, H.W.1
Tsai, W.B.2
-
28
-
-
77956896559
-
Molecularly imprinted polymeric microspheres for determination of bovine serum albumin based on flow injection chemiluminescence sensor
-
Y. Jinghua, W. Fuwei, Z. Congcong, Y. Mei, Z. Xiaona, and W. Shaowei Molecularly imprinted polymeric microspheres for determination of bovine serum albumin based on flow injection chemiluminescence sensor Biosens. Bioelectron. 26 2010 632 637
-
(2010)
Biosens. Bioelectron.
, vol.26
, pp. 632-637
-
-
Jinghua, Y.1
Fuwei, W.2
Congcong, Z.3
Mei, Y.4
Xiaona, Z.5
Shaowei, W.6
-
29
-
-
76249105826
-
Complexes of dendrimers with bovine serum albumin
-
J.S. Mandeville, and H.A. Tajmir-Riahi Complexes of dendrimers with bovine serum albumin Biomacromolecules 11 2010 465 472
-
(2010)
Biomacromolecules
, vol.11
, pp. 465-472
-
-
Mandeville, J.S.1
Tajmir-Riahi, H.A.2
-
30
-
-
2342498241
-
Determination of albumin concentration by MIP-QCM sensor
-
T.-Y. Lin, C.-H. Hu, and T.-C. Chou Determination of albumin concentration by MIP-QCM sensor Biosens. Bioelectron. 20 2004 75 81
-
(2004)
Biosens. Bioelectron.
, vol.20
, pp. 75-81
-
-
Lin, T.-Y.1
Hu, C.-H.2
Chou, T.-C.3
-
31
-
-
0242401900
-
Polarographic behaviour of Co(II)-BSA or HSA complex in the presence of a guanidine modifier
-
D.B. Luo, J.G. Lan, C. Zhou, and C.X. Luo Polarographic behaviour of Co(II)-BSA or HSA complex in the presence of a guanidine modifier Anal. Chem. 75 2003 6346 6350
-
(2003)
Anal. Chem.
, vol.75
, pp. 6346-6350
-
-
Luo, D.B.1
Lan, J.G.2
Zhou, C.3
Luo, C.X.4
-
32
-
-
2442665517
-
Secondary structure analysis of proteins embedded in spherical polyelectrolyte brushes by FT-IR spectroscopy
-
A. Wittemann, and M. Ballauf Secondary structure analysis of proteins embedded in spherical polyelectrolyte brushes by FT-IR spectroscopy Anal. Chem. 76 2004 2813 2819
-
(2004)
Anal. Chem.
, vol.76
, pp. 2813-2819
-
-
Wittemann, A.1
Ballauf, M.2
-
34
-
-
71849101052
-
Immunochemical binding assays for detection and quantification of trace impurities in biotechnological production
-
B. Mattiasson, K. Teeparuksapun, and M. Hedström Immunochemical binding assays for detection and quantification of trace impurities in biotechnological production Trends Biotechnol. 28 2009 20 27
-
(2009)
Trends Biotechnol.
, vol.28
, pp. 20-27
-
-
Mattiasson, B.1
Teeparuksapun, K.2
Hedström, M.3
-
36
-
-
34548257739
-
Capacitive biosensor for detection of endotoxin
-
W. Limbut, M. Hedström, P. Thavarungkul, P. Kanatharana, and B. Mattiasson Capacitive biosensor for detection of endotoxin Anal. Bioanal. Chem. 389 2007 517 525
-
(2007)
Anal. Bioanal. Chem.
, vol.389
, pp. 517-525
-
-
Limbut, W.1
Hedström, M.2
Thavarungkul, P.3
Kanatharana, P.4
Mattiasson, B.5
-
37
-
-
0024514067
-
Sensitive detection of protein adsorption to supported lipid bilayers by frequency-dependent capacitance measurements and microelectrophoresis
-
M. Stelzle, and E. Sackmann Sensitive detection of protein adsorption to supported lipid bilayers by frequency-dependent capacitance measurements and microelectrophoresis Biochim. Biophys. Acta 981 1989 135 142
-
(1989)
Biochim. Biophys. Acta
, vol.981
, pp. 135-142
-
-
Stelzle, M.1
Sackmann, E.2
-
38
-
-
0025862232
-
Toxin detection using capacitance measurements on immunospecies grafted onto a semiconductor substrate
-
V. Billard, C. Martelet, P. Binder, and J. Therasse Toxin detection using capacitance measurements on immunospecies grafted onto a semiconductor substrate Anal. Chim. Acta 249 1991 367 372
-
(1991)
Anal. Chim. Acta
, vol.249
, pp. 367-372
-
-
Billard, V.1
Martelet, C.2
Binder, P.3
Therasse, J.4
-
39
-
-
72549098660
-
A novel competitive capacitive glucose biosensor based on concanavalin A-labeled nanogold colloids assembled on a polytyramine-modified gold electrode
-
M. Labib, M. Hedström, M. Amin, and B. Mattiasson A novel competitive capacitive glucose biosensor based on concanavalin A-labeled nanogold colloids assembled on a polytyramine-modified gold electrode Anal. Chim. Acta 659 2010 194 200
-
(2010)
Anal. Chim. Acta
, vol.659
, pp. 194-200
-
-
Labib, M.1
Hedström, M.2
Amin, M.3
Mattiasson, B.4
-
41
-
-
20444480914
-
Continuous measurements of a binding reaction using a capacitive biosensor
-
M. Hedström, I.Y. Galaev, and B. Mattiasson Continuous measurements of a binding reaction using a capacitive biosensor Biosens. Bioelectron. 21 2005 41 48
-
(2005)
Biosens. Bioelectron.
, vol.21
, pp. 41-48
-
-
Hedström, M.1
Galaev, I.Y.2
Mattiasson, B.3
-
42
-
-
70349329559
-
A multipurpose capacitive biosensor for assay and quality control of human immunoglobulin G
-
M. Labib, M. Hedström, M. Amin, and B. Mattiasson A multipurpose capacitive biosensor for assay and quality control of human immunoglobulin G Biotechnol. Bioeng. 104 2009 312 320
-
(2009)
Biotechnol. Bioeng.
, vol.104
, pp. 312-320
-
-
Labib, M.1
Hedström, M.2
Amin, M.3
Mattiasson, B.4
-
43
-
-
84884678128
-
Automated flow-injection immunosensor based on current pulse capacitive measurements
-
D. Erlandsson, K. Teeparuksapun, B. Mattiasson, and M. Hedström Automated flow-injection immunosensor based on current pulse capacitive measurements Sens. Actuat. B 190 2014 295 304
-
(2014)
Sens. Actuat. B
, vol.190
, pp. 295-304
-
-
Erlandsson, D.1
Teeparuksapun, K.2
Mattiasson, B.3
Hedström, M.4
-
45
-
-
77958031676
-
Ultrasensitive detection of HIV-1 p24 antigen using nano-functionalized surfaces in a capacitive immunosensor
-
K. Teeparuksapun, M. Hedström, E.Y. Wong, S. Tang, I.K. Hewlett, and B. Mattiasson Ultrasensitive detection of HIV-1 p24 antigen using nano-functionalized surfaces in a capacitive immunosensor Anal. Chem. 82 2010 8406 8411
-
(2010)
Anal. Chem.
, vol.82
, pp. 8406-8411
-
-
Teeparuksapun, K.1
Hedström, M.2
Wong, E.Y.3
Tang, S.4
Hewlett, I.K.5
Mattiasson, B.6
-
46
-
-
84855220149
-
Capacitive immunosensor for detection of host cell proteins
-
K. Teeparuksapun, M. Hedström, P. Kanatharana, P. Thavarungkul, and B. Mattiasson Capacitive immunosensor for detection of host cell proteins J. Biotechnol. 157 2012 207 213
-
(2012)
J. Biotechnol.
, vol.157
, pp. 207-213
-
-
Teeparuksapun, K.1
Hedström, M.2
Kanatharana, P.3
Thavarungkul, P.4
Mattiasson, B.5
-
47
-
-
60749110917
-
A capacitive immunosensor for detection of staphylococcal enterotoxin B
-
M. Labib, Hedström M, Amin M, and Mattiasson B A capacitive immunosensor for detection of staphylococcal enterotoxin B Anal. Bioanal. Chem. 393 2009 1539 1544
-
(2009)
Anal. Bioanal. Chem.
, vol.393
, pp. 1539-1544
-
-
Labib, M.1
Hedström, M.2
Amin, M.3
Mattiasson, B.4
-
48
-
-
84904902933
-
Sub-attomolar detection of cholera toxin using a label-free capacitive biosensor
-
S. Loyprasert, M. Hedström, P. Kanatharana, P. Thavarungkul, and B. Mattiasson Sub-attomolar detection of cholera toxin using a label-free capacitive biosensor Biosens. Bioelectron. 27 2010 41 48
-
(2010)
Biosens. Bioelectron.
, vol.27
, pp. 41-48
-
-
Loyprasert, S.1
Hedström, M.2
Kanatharana, P.3
Thavarungkul, P.4
Mattiasson, B.5
|