메뉴 건너뛰기




Volumn 357 CCIS, Issue , 2013, Pages 23-40

Dry and Water-Based EEG Electrodes in SSVEP-Based BCI Applications

Author keywords

BCI; Brain computer interface; Dry electrodes; EEG; Signal quality; SSVEP; Steady state visual evoked potential; Water based electrodes

Indexed keywords

BIOMEDICAL ENGINEERING; BRAIN COMPUTER INTERFACE; ELECTROENCEPHALOGRAPHY;

EID: 84904611539     PISSN: 18650929     EISSN: None     Source Type: Book Series    
DOI: 10.1007/978-3-642-38256-7_2     Document Type: Conference Paper
Times cited : (11)

References (45)
  • 1
    • 54149091772 scopus 로고    scopus 로고
    • Brain-Computer Interfaces and Communication in Paralysis: Extinction of Goal Directed Thinking in Completerly Paralysed Patients
    • Kübler, A., Birbaumer, N.: Brain-Computer Interfaces and Communication in Paralysis: Extinction of Goal Directed Thinking in Completerly Paralysed Patients. Clinical Neurophysiology 119, 2658-2666 (2008).
    • (2008) Clinical Neurophysiology , vol.119 , pp. 2658-2666
    • Kübler, A.1    Birbaumer, N.2
  • 2
    • 0036785277 scopus 로고    scopus 로고
    • Design and Implementation of a Brain-Ccomputer Interface with High Transfer Rates
    • Cheng, M., Gao, X., Gao, S.: Design and Implementation of a Brain-Ccomputer Interface with High Transfer Rates. IEEE Transactions on Biomedical Engineering 49, 1181-1186 (2002).
    • (2002) IEEE Transactions on Biomedical Engineering , vol.49 , pp. 1181-1186
    • Cheng, M.1    Gao, X.2    Gao, S.3
  • 8
    • 77953280087 scopus 로고    scopus 로고
    • Spatial Filters to Detect Steady-State Visual Evoked Potentials Elicited by High Frequency Stimulation: BCI Application
    • Garcia-Molina, G., Mihajlović, V.: Spatial Filters to Detect Steady-State Visual Evoked Potentials Elicited by High Frequency Stimulation: BCI Application. Biomedical Engineering 55, 173-182 (2010).
    • (2010) Biomedical Engineering , vol.55 , pp. 173-182
    • Garcia-Molina, G.1    Mihajlović, V.2
  • 10
    • 26944468742 scopus 로고    scopus 로고
    • Photic-and Pattern-Induced Seizures: A Review for the Epilepsy Foundation of America Working Group
    • Fisher, R. S., Harding, G., Erba, G., Barkley, G. L., Wilkins, A.: Photic-and Pattern-Induced Seizures: a Review for the Epilepsy Foundation of America Working Group. Epilepsia 46, 1426-1441 (2005).
    • (2005) Epilepsia , vol.46 , pp. 1426-1441
    • Fisher, R.S.1    Harding, G.2    Erba, G.3    Barkley, G.L.4    Wilkins, A.5
  • 14
    • 79956006562 scopus 로고    scopus 로고
    • Remote Detection of Human Electroencephalograms using Ultrahigh Input Impedance Electric Potential Sensors
    • Harland, C. J., Clark, T. D., Prance, R. J.: Remote Detection of Human Electroencephalograms using Ultrahigh Input Impedance Electric Potential Sensors. Applied Physics Letters 81, 3284-3286 (2002).
    • (2002) Applied Physics Letters , vol.81 , pp. 3284-3286
    • Harland, C.J.1    Clark, T.D.2    Prance, R.J.3
  • 28
    • 78249262601 scopus 로고    scopus 로고
    • New Dry Electrodes Based on Iridium Oxide (IrO) for Non-Invasive Biopotential Recordings and Stimulation
    • Dias, N., Carmo, J., da Silva, A. F., Mendes, P. M., Correia, J.: New Dry Electrodes Based on Iridium Oxide (IrO) for Non-Invasive Biopotential Recordings and Stimulation. Sensors and Actuators A: Physical 164, 28-34 (2010).
    • (2010) Sensors and Actuators A: Physical , vol.164 , pp. 28-34
    • Dias, N.1    Carmo, J.2    da Silva, A.F.3    Mendes, P.M.4    Correia, J.5
  • 32
    • 79954498413 scopus 로고    scopus 로고
    • Bristle-Sensors-Low-Cost Flexible Passive Dry EEG Electrodes for Neurofeedback and BCI Applications
    • Grozea, C., Voinescu, C. D., Fazli, S.: Bristle-Sensors-Low-Cost Flexible Passive Dry EEG Electrodes for Neurofeedback and BCI Applications. Journal of Neural Engineering 8 (2011).
    • (2011) Journal of Neural Engineering , vol.8
    • Grozea, C.1    Voinescu, C.D.2    Fazli, S.3
  • 34
    • 0035109061 scopus 로고    scopus 로고
    • Scalp Electrode Impedance, Infection Risk, and EEG Data Quality
    • Ferree, T. C., Luu, P., Russell, G. S., Tucker, D. M.: Scalp Electrode Impedance, Infection Risk, and EEG Data Quality. Clinical Neurophysiology 112, 536-544 (2001).
    • (2001) Clinical Neurophysiology , vol.112 , pp. 536-544
    • Ferree, T.C.1    Luu, P.2    Russell, G.S.3    Tucker, D.M.4
  • 38
    • 39849099081 scopus 로고    scopus 로고
    • Single Trial Classification of Motor Imagination Using 6 Dry EEG Electrodes
    • Popescu, F., Fazli, S., Badower, Y., Blankertz, B., Müller, K. R.: Single Trial Classification of Motor Imagination Using 6 Dry EEG Electrodes. PloS One 2, e637 (2007).
    • (2007) PloS One , vol.2
    • Popescu, F.1    Fazli, S.2    Badower, Y.3    Blankertz, B.4    Müller, K.R.5
  • 40
    • 77949879765 scopus 로고    scopus 로고
    • A User-Friendly SSVEP-Based Brain-Computer Interface using a Time-Domain Classifier
    • Luo, A., Sullivan, T. J.: A User-Friendly SSVEP-Based Brain-Computer Interface using a Time-Domain Classifier. Journal of Neural Engineering 7, 1-10 (2010).
    • (2010) Journal of Neural Engineering , vol.7 , pp. 1-10
    • Luo, A.1    Sullivan, T.J.2
  • 42
    • 84908144695 scopus 로고
    • The Use of Fast Fourier Transform for the Estimation of Power Spectra: A Method Based on Time Averaging over Short, Modified Periodograms
    • Welch, P. D.: The Use of Fast Fourier Transform for the Estimation of Power Spectra: A Method Based on Time Averaging over Short, Modified Periodograms. IEEE Transactions of Audio and Electroacoustics 15, 70-73 (1967).
    • (1967) IEEE Transactions of Audio and Electroacoustics , vol.15 , pp. 70-73
    • Welch, P.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.