메뉴 건너뛰기




Volumn 35, Issue 8, 2014, Pages 987-994

The use of rapid indicators for the detection of organic residues on clinically used gastrointestinal endoscopes with and without visually apparent debris

Author keywords

[No Author keywords available]

Indexed keywords

ADENOSINE TRIPHOSPHATE; PROTEIN;

EID: 84904406739     PISSN: 0899823X     EISSN: None     Source Type: Journal    
DOI: 10.1086/677148     Document Type: Article
Times cited : (40)

References (40)
  • 2
    • 79957963760 scopus 로고    scopus 로고
    • Multisociety guideline on reprocessing flexible GI endoscopes: 2011
    • Petersen BT, Chennat J, Cohen J, et al. Multisociety guideline on reprocessing flexible GI endoscopes: 2011. Infect ControlHosp Epidemiol 2011; 32(6): 527-537.
    • (2011) Infect ControlHosp Epidemiol , vol.32 , Issue.6 , pp. 527-537
    • Petersen, B.T.1    Chennat, J.2    Cohen, J.3
  • 3
    • 33746256649 scopus 로고    scopus 로고
    • Current issues in endoscope reprocessing and infection control during gastrointestinal endoscopy
    • Nelson DB, Muscarella LF. Current issues in endoscope reprocessing and infection control during gastrointestinal endoscopy. World J Gastroenterol 2006; 12(25): 3953-3964.
    • (2006) World J Gastroenterol , vol.12 , Issue.25 , pp. 3953-3964
    • Nelson, D.B.1    Muscarella, L.F.2
  • 4
    • 77955449995 scopus 로고    scopus 로고
    • Endoscope reprocessing methods: A prospective study on the impact of human factors and automation
    • Ofstead CL, Wetzler HP, Snyder AK, Horton RA. Endoscope reprocessing methods: a prospective study on the impact of human factors and automation. Gastroenterol Nurs 2010; 33(4): 304-311.
    • (2010) Gastroenterol Nurs , vol.33 , Issue.4 , pp. 304-311
    • Ofstead, C.L.1    Wetzler, H.P.2    Snyder, A.K.3    Horton, R.A.4
  • 5
    • 84875720123 scopus 로고    scopus 로고
    • Better instructions for use to improve reusable medical equipment (RME) sterility
    • Jolly JD, Hildebrand EA, Branaghan RJ. Better instructions for use to improve reusable medical equipment (RME) sterility. Human Factors 2013; 55(2): 397-410.
    • (2013) Human Factors , vol.55 , Issue.2 , pp. 397-410
    • Jolly, J.D.1    Hildebrand, E.A.2    Branaghan, R.J.3
  • 8
    • 0032862918 scopus 로고    scopus 로고
    • Worst-case soiling levels for patient-used flexible endoscopes before and after cleaning
    • Alfa MJ, Degagne P, Olson N. Worst-case soiling levels for patient-used flexible endoscopes before and after cleaning. Am J Infect Control 1999; 27(5): 392-401.
    • (1999) Am J Infect Control , vol.27 , Issue.5 , pp. 392-401
    • Alfa, M.J.1    Degagne, P.2    Olson, N.3
  • 11
    • 84875750271 scopus 로고    scopus 로고
    • Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy
    • Kovaleva J, Peters FT, van der Mei HC, Degener JE. Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy. Clin Microbiol Rev 2013; 26(2): 231-254.
    • (2013) Clin Microbiol Rev , vol.26 , Issue.2 , pp. 231-254
    • Kovaleva, J.1    Peters, F.T.2    van der Mei, H.C.3    Degener, J.E.4
  • 12
    • 0030764517 scopus 로고    scopus 로고
    • Patient-to-patient transmission of hepatitis C virus during colonoscopy
    • Bronowicki JP, Venard V, Botte C, et al. Patient-to-patient transmission of hepatitis C virus during colonoscopy. N Engl J Med 1997; 337(4): 237-240.
    • (1997) N Engl J Med , vol.337 , Issue.4 , pp. 237-240
    • Bronowicki, J.P.1    Venard, V.2    Botte, C.3
  • 13
    • 84875398961 scopus 로고    scopus 로고
    • Gastroscopy-associated transmission of extended-spectrum beta-lactamase-producing Pseudomonas aeruginosa
    • Bajolet O, Ciocan D, Vallet C, et al. Gastroscopy-associated transmission of extended-spectrum beta-lactamase-producing Pseudomonas aeruginosa. J Hosp Infect 2013; 83(4): 341-343.
    • (2013) J Hosp Infect , vol.83 , Issue.4 , pp. 341-343
    • Bajolet, O.1    Ciocan, D.2    Vallet, C.3
  • 14
    • 84888436686 scopus 로고    scopus 로고
    • Vancouver Island Health Authority (VIHA), Vancouver: VIHA
    • Vancouver Island Health Authority (VIHA). Backgrounder: ERCP Scope Reprocessing and Infection Control. http://www. viha. ca/NR/rdonlyres/8E35C250-1841-4ADD-B9F7-353780C29272/0/BG_ercp_scope_disinfection. pdf. Vancouver: VIHA, 2010.
    • (2010) Backgrounder: ERCP Scope Reprocessing and Infection Control
  • 16
    • 84898543210 scopus 로고    scopus 로고
    • Klebsiella spp in endoscopy-associated infections: We may only be seeing the tip of the iceberg
    • Gastmeier P, Vonberg RP. Klebsiella spp. in endoscopy-associated infections: we may only be seeing the tip of the iceberg. Infection 2014; 42(1)15-21.
    • (2014) Infection , vol.42 , Issue.1 , pp. 15-21
    • Gastmeier, P.1    Vonberg, R.P.2
  • 17
    • 78349290090 scopus 로고    scopus 로고
    • Multidrug-resistant Klebsiella pneumoniae outbreak after endoscopic retrograde cholangiopancreatography
    • Aumeran C, Poincloux L, Souweine B, et al. Multidrug-resistant Klebsiella pneumoniae outbreak after endoscopic retrograde cholangiopancreatography. Endoscopy 2010; 42(11): 895-899.
    • (2010) Endoscopy , vol.42 , Issue.11 , pp. 895-899
    • Aumeran, C.1    Poincloux, L.2    Souweine, B.3
  • 18
    • 78649974133 scopus 로고    scopus 로고
    • Control of a multihospital outbreak of KPC-producing Klebsiella pneumoniae type 2 in France, September to October 2009
    • Carbonne A, Thiolet JM, Fournier S, et al. Control of a multihospital outbreak of KPC-producing Klebsiella pneumoniae type 2 in France, September to October 2009. Euro Surveil 2010; 15(48): 1-6.
    • (2010) Euro Surveil , vol.15 , Issue.48 , pp. 1-6
    • Carbonne, A.1    Thiolet, J.M.2    Fournier, S.3
  • 19
    • 84878893539 scopus 로고    scopus 로고
    • Early identification and control of carbapenemase-producing Klebsiella pneumoniae, originating from contaminated endoscopic equipment
    • Alrabaa SF, Nguyen P, Sanderson R, et al. Early identification and control of carbapenemase-producing Klebsiella pneumoniae, originating from contaminated endoscopic equipment. Am J Infect Control 2013; 41(6): 562-564.
    • (2013) Am J Infect Control , vol.41 , Issue.6 , pp. 562-564
    • Alrabaa, S.F.1    Nguyen, P.2    Sanderson, R.3
  • 21
    • 33947136836 scopus 로고    scopus 로고
    • ESG-ESGENA guideline for quality assurance in reprocessing: Microbiological surveillance testing in endoscopy
    • Beilenhoff U, Neumann CS, Rey JF, et al. ESG-ESGENA guideline for quality assurance in reprocessing: microbiological surveillance testing in endoscopy. Endoscopy 2007; 39: 175-181.
    • (2007) Endoscopy , vol.39 , pp. 175-181
    • Beilenhoff, U.1    Neumann, C.S.2    Rey, J.F.3
  • 22
    • 84904398140 scopus 로고    scopus 로고
    • Health Service Executive (HSE) Advisory Group, Accessed December 6, Tipperary, Ireland: HSE, 2012
    • Health Service Executive (HSE) Advisory Group. HSE Standards and Recommended Practices for Endoscope Reprocessing Units. Tipperary, Ireland: HSE, 2012. http://www. hse. ie/eng/about/Who/qualityandpatientsafety/resourcesintelligence/Quality_and_Patient_Safety_Documents/endoscope_reprocessing_version22. pdf. Accessed December 6, 2013.
    • (2013) HSE Standards and Recommended Practices for Endoscope Reprocessing Units
  • 23
    • 84904393175 scopus 로고    scopus 로고
    • Gastoenterological Society of Australia (GESA), Accessed December 6, Victoria, Australia: GESA, 2011
    • Gastoenterological Society of Australia (GESA). Infection Control in Endoscopy. Victoria, Australia: GESA, 2011. http://www. gesa. org. au/professional. asp?cidp9&idp123. Accessed December 6, 2013.
    • (2013) Infection Control in Endoscopy
  • 24
    • 84868210217 scopus 로고    scopus 로고
    • Development and validation of rapid use scope test strips to determine the efficacy of manual cleaning for flexible endoscope channels
    • Alfa MJ, Olson N, Degagne P, Simner PJ. Development and validation of rapid use scope test strips to determine the efficacy of manual cleaning for flexible endoscope channels. Am J Infect Control 2012; 40(9): 860-865.
    • (2012) Am J Infect Control , vol.40 , Issue.9 , pp. 860-865
    • Alfa, M.J.1    Olson, N.2    Degagne, P.3    Simner, P.J.4
  • 25
    • 84875368857 scopus 로고    scopus 로고
    • Validation of adenosine triphosphate to audit manual cleaning of flexible endoscope channels
    • Alfa MJ, Fatima I, Olson N. Validation of adenosine triphosphate to audit manual cleaning of flexible endoscope channels. Am J Infect Control 2013; 41(3): 245-248.
    • (2013) Am J Infect Control , vol.41 , Issue.3 , pp. 245-248
    • Alfa, M.J.1    Fatima, I.2    Olson, N.3
  • 26
    • 84873093229 scopus 로고    scopus 로고
    • Comparison of adenosine triphosphate, microbiological load, and residual protein as indicators for assessing the cleanliness of flexible gastrointestinal endoscopes
    • Fushimi R, Takashina M, Yoshikawa H, et al. Comparison of adenosine triphosphate, microbiological load, and residual protein as indicators for assessing the cleanliness of flexible gastrointestinal endoscopes. Am J Infect Control 2013; 41(2): 161-164.
    • (2013) Am J Infect Control , vol.41 , Issue.2 , pp. 161-164
    • Fushimi, R.1    Takashina, M.2    Yoshikawa, H.3
  • 27
  • 28
    • 79955493649 scopus 로고    scopus 로고
    • Evaluation of ATP bioluminescence assays for potential use in a hospital setting
    • Aiken ZA, Wilson M, Pratten J. Evaluation of ATP bioluminescence assays for potential use in a hospital setting. Infect Control Hosp Epidemiol 2011; 32(5): 507-509.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , Issue.5 , pp. 507-509
    • Aiken, Z.A.1    Wilson, M.2    Pratten, J.3
  • 34
    • 84875371276 scopus 로고    scopus 로고
    • The adenosine triphosphate test is a rapid and reliable audit tool to assess manual cleaning adequacy of flexible endoscope channels
    • Alfa MJ, Fatima I, Olson N. The adenosine triphosphate test is a rapid and reliable audit tool to assess manual cleaning adequacy of flexible endoscope channels. Am J Infect Control 2013; 41(3): 249-253.
    • (2013) Am J Infect Control , vol.41 , Issue.3 , pp. 249-253
    • Alfa, M.J.1    Fatima, I.2    Olson, N.3
  • 35
    • 66949164844 scopus 로고    scopus 로고
    • Modeling microbial survival in buildup biofilm for complex medical devices
    • Alfa MJ, Howie R. Modeling microbial survival in buildup biofilm for complex medical devices. BMC Infect Dis 2009; 9: 56.
    • (2009) BMC Infect Dis , vol.9 , pp. 56
    • Alfa, M.J.1    Howie, R.2
  • 36
    • 84863000599 scopus 로고    scopus 로고
    • Doubt and proof: The need to verify the cleaning process
    • Azizi J, Basile RJ. Doubt and proof: the need to verify the cleaning process. Biomed Instrum Technol 2012; 46: 49-54.
    • (2012) Biomed Instrum Technol , vol.46 , pp. 49-54
    • Azizi, J.1    Basile, R.J.2
  • 37
    • 84871007102 scopus 로고    scopus 로고
    • Current limitations about the cleaning of luminal endoscopes
    • Herve R, Keevil CW. Current limitations about the cleaning of luminal endoscopes. J Hosp Infect 2013; 83(1): 22-29.
    • (2013) J Hosp Infect , vol.83 , Issue.1 , pp. 22-29
    • Herve, R.1    Keevil, C.W.2
  • 38
    • 1942484351 scopus 로고    scopus 로고
    • The importance of cleaning for the overall results of processing endoscopes
    • Martiny H, Floss H, Zuhlsdorf B. The importance of cleaning for the overall results of processing endoscopes. J Hosp Infect 2004; 56(suppl 2): S16-S22.
    • (2004) J Hosp Infect , vol.56 , Issue.SUPPL. 2
    • Martiny, H.1    Floss, H.2    Zuhlsdorf, B.3
  • 39
    • 84876912735 scopus 로고    scopus 로고
    • New developments in reprocessing semicritical items
    • Rutala WA, Weber DJ. New developments in reprocessing semicritical items. Am J Infect Control 2013; 41(5 suppl): S60-S66.
    • (2013) Am J Infect Control , vol.41 , Issue.5 SUPPL.
    • Rutala, W.A.1    Weber, D.J.2
  • 40
    • 84904398142 scopus 로고    scopus 로고
    • Department of Health and Human Services, Healthcare Financing Administration, Monroeville, PA: Forbes Regional Hospital, April 7, State License 311101
    • Department of Health and Human Services, Healthcare Financing Administration. Statement of Deficiencies and Plan of Correction. Monroeville, PA: Forbes Regional Hospital, April 7, 2005. State License 311101.
    • (2005) Statement of Deficiencies and Plan of Correction


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.