메뉴 건너뛰기




Volumn 41, Issue 3, 2013, Pages 245-248

Validation of adenosine triphosphate to audit manual cleaning of flexible endoscope channels

Author keywords

Benchmark; Cleaning compliance; Endoscope channel; Relative light units; Simulated use

Indexed keywords

ADENOSINE TRIPHOSPHATE; HEMOGLOBIN; PROTEIN;

EID: 84875368857     PISSN: 01966553     EISSN: 15273296     Source Type: Journal    
DOI: 10.1016/j.ajic.2012.03.018     Document Type: Article
Times cited : (87)

References (15)
  • 1
    • 1942516358 scopus 로고    scopus 로고
    • Reprocessing endoscopes: United States perspective
    • W.A. Rutala, and D.J. Weber Reprocessing endoscopes: United States perspective J Hosp Infect 56 2004 S27 S39
    • (2004) J Hosp Infect , vol.56
    • Rutala, W.A.1    Weber, D.J.2
  • 2
    • 78349290090 scopus 로고    scopus 로고
    • Multidrug-resistant Klebsiella pneumoniae outbreak after endoscopic retrograde cholangiopancreatography
    • C. Aumeran, L. Poincloux, B. Souweine, F. Robin, H. Laurichesse, and O. Baud Multidrug-resistant Klebsiella pneumoniae outbreak after endoscopic retrograde cholangiopancreatography Endoscopy 42 2010 957 959
    • (2010) Endoscopy , vol.42 , pp. 957-959
    • Aumeran, C.1    Poincloux, L.2    Souweine, B.3    Robin, F.4    Laurichesse, H.5    Baud, O.6
  • 3
    • 33947136836 scopus 로고    scopus 로고
    • ESGE-ESGENA guideline for quality assurance in reprocessing: Microbiological surveillance testing in endoscopy
    • U. Bellenhoff, C.S. Neumann, J.F. Rey, H. Biering, R. Blum, and V. Schmidt ESGE-ESGENA guideline for quality assurance in reprocessing: microbiological surveillance testing in endoscopy Endoscopy 39 2007 175 181
    • (2007) Endoscopy , vol.39 , pp. 175-181
    • Bellenhoff, U.1    Neumann, C.S.2    Rey, J.F.3    Biering, H.4    Blum, R.5    Schmidt, V.6
  • 4
    • 16544395381 scopus 로고    scopus 로고
    • Monitoring quality of flexible endoscope disinfection by microbiologic surveillance cultures
    • A. Tunuguntla, and M.J. Sullivan Monitoring quality of flexible endoscope disinfection by microbiologic surveillance cultures Tennessee Med 97 2004 453 456
    • (2004) Tennessee Med , vol.97 , pp. 453-456
    • Tunuguntla, A.1    Sullivan, M.J.2
  • 6
    • 33744810095 scopus 로고    scopus 로고
    • A prospective study of the efficacy of routine decontamination for gastrointestinal endoscopes and the risk factors for failure
    • L. Bisset, Y.E. Cossart, W. Selby, R. West, D. Catterson, and K. O'Hara A prospective study of the efficacy of routine decontamination for gastrointestinal endoscopes and the risk factors for failure Am J Infect Control 34 2006 274 280
    • (2006) Am J Infect Control , vol.34 , pp. 274-280
    • Bisset, L.1    Cossart, Y.E.2    Selby, W.3    West, R.4    Catterson, D.5    O'Hara, K.6
  • 7
    • 34548316269 scopus 로고    scopus 로고
    • Sporicidal activity of disinfectants as one possible cause for bacteria in patient-ready endoscopes
    • N. Miner, V. Harris, T. Ebron, and T.-D. Cao Sporicidal activity of disinfectants as one possible cause for bacteria in patient-ready endoscopes Gastroenterol Nurs 30 2007 285 290
    • (2007) Gastroenterol Nurs , vol.30 , pp. 285-290
    • Miner, N.1    Harris, V.2    Ebron, T.3    Cao, T.-D.4
  • 10
    • 18844426232 scopus 로고    scopus 로고
    • Real-time monitoring in managing the decontamination of flexible gastrointestinal endoscopes
    • P. Obee, C. Griffith, R. Cooper, R. Cooke, N. Bennion, and M. Lewis Real-time monitoring in managing the decontamination of flexible gastrointestinal endoscopes Am J Infect Control 33 2005 202 206
    • (2005) Am J Infect Control , vol.33 , pp. 202-206
    • Obee, P.1    Griffith, C.2    Cooper, R.3    Cooke, R.4    Bennion, N.5    Lewis, M.6
  • 11
    • 79955493649 scopus 로고    scopus 로고
    • Evaluation of ATP bioluminescence assays for potential use in a hospital setting
    • Z.A. Aiken, N. Wilson, and J. Pratten Evaluation of ATP bioluminescence assays for potential use in a hospital setting Infect Control Hosp Epidemiol 32 2011 507 509
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 507-509
    • Aiken, Z.A.1    Wilson, N.2    Pratten, J.3
  • 12
    • 34547662094 scopus 로고    scopus 로고
    • The effectiveness of existing and modified cleaning regimens in a Welsh hospital
    • C.J. Griffith, P. Obee, R.A. Cooper, N.F. Burton, and M. Lewis The effectiveness of existing and modified cleaning regimens in a Welsh hospital J Hosp Infect 66 2007 352 359
    • (2007) J Hosp Infect , vol.66 , pp. 352-359
    • Griffith, C.J.1    Obee, P.2    Cooper, R.A.3    Burton, N.F.4    Lewis, M.5
  • 14
    • 0032862918 scopus 로고    scopus 로고
    • Worse-case soiling levels for patient-used flexible endoscopes before and after cleaning
    • M.J. Alfa, P. DeGagne, and N. Olson Worse-case soiling levels for patient-used flexible endoscopes before and after cleaning Am J Infect Control 27 1999 392 401
    • (1999) Am J Infect Control , vol.27 , pp. 392-401
    • Alfa, M.J.1    Degagne, P.2    Olson, N.3
  • 15
    • 29944435407 scopus 로고    scopus 로고
    • Validation of ATS as an appropriate test soil
    • M.J. Alfa, P. DeGagne, and N. Olson Validation of ATS as an appropriate test soil Zentr Steril 13 2005 387 402
    • (2005) Zentr Steril , vol.13 , pp. 387-402
    • Alfa, M.J.1    Degagne, P.2    Olson, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.