메뉴 건너뛰기




Volumn 4, Issue 1, 2014, Pages 1-12

Personalized predictive lung dosimetry by technetium-99m macroaggregated albumin SPECT/CT for yttrium-90 radioembolization

Author keywords

CT lung densitovolumetry; Lung mass; Partition model; Selective internal radiation therapy; Technetium 99m macroaggregated albumin SPECT CT; Yttrium 90 radioembolization

Indexed keywords

TECHNETIUM 99M; YTTRIUM 90;

EID: 84903806186     PISSN: None     EISSN: 2191219X     Source Type: Journal    
DOI: 10.1186/s13550-014-0033-7     Document Type: Article
Times cited : (61)

References (27)
  • 1
    • 0028307124 scopus 로고
    • Radiation pneumonitis caused by yttrium-90 microspheres: radiologic findings
    • COI: 1:STN:280:DyaK2c3kvFGisg%3D%3D, PID: 8191985
    • Lin M: Radiation pneumonitis caused by yttrium-90 microspheres: radiologic findings.AJR Am J Roentgenol 1994, 162:1300–1302.
    • (1994) AJR Am J Roentgenol , vol.162 , pp. 1300-1302
    • Lin, M.1
  • 2
    • 0028783988 scopus 로고
    • Radiation pneumonitis after selective internal radiation treatment with intraarterial 90yttrium microspheres for inoperable hepatic tumors
    • COI: 1:STN:280:DyaK28%2FmslWrsA%3D%3D, PID: 7591903
    • Leung TW, Lau WY, Ho SK, Ward SC, Chow JH, Chan MS, Metreweli C, Johnson PJ, Li AK: Radiation pneumonitis after selective internal radiation treatment with intraarterial 90yttrium microspheres for inoperable hepatic tumors.Int J Radiat Oncol Biol Phys 1995, 33:919–924.
    • (1995) Int J Radiat Oncol Biol Phys , vol.33 , pp. 919-924
    • Leung, T.W.1    Lau, W.Y.2    Ho, S.K.3    Ward, S.C.4    Chow, J.H.5    Chan, M.S.6    Metreweli, C.7    Johnson, P.J.8    Li, A.K.9
  • 3
  • 6
    • 0029737746 scopus 로고    scopus 로고
    • Partition model for estimating radiation doses from yttrium-90 microspheres in treating hepatic tumours
    • COI: 1:STN:280:DyaK28zisVChtA%3D%3D, PID: 8753684
    • Ho S, Lau WY, Leung TW, Chan M, Ngar YK, Johnson PJ, Li AK: Partition model for estimating radiation doses from yttrium-90 microspheres in treating hepatic tumours.Eur J Nucl Med 1996, 23:947–952.
    • (1996) Eur J Nucl Med , vol.23 , pp. 947-952
    • Ho, S.1    Lau, W.Y.2    Leung, T.W.3    Chan, M.4    Ngar, Y.K.5    Johnson, P.J.6    Li, A.K.7
  • 7
    • 0031002101 scopus 로고    scopus 로고
    • Clinical evaluation of the partition model for estimating radiation doses from yttrium-90 microspheres in the treatment of hepatic cancer
    • COI: 1:STN:280:DyaK2s3ovVCruw%3D%3D, PID: 9143467
    • Ho S, Lau WY, Leung TW, Chan M, Johnson PJ, Li AK: Clinical evaluation of the partition model for estimating radiation doses from yttrium-90 microspheres in the treatment of hepatic cancer.Eur J Nucl Med 1997, 24:293–298.
    • (1997) Eur J Nucl Med , vol.24 , pp. 293-298
    • Ho, S.1    Lau, W.Y.2    Leung, T.W.3    Chan, M.4    Johnson, P.J.5    Li, A.K.6
  • 8
    • 84893605905 scopus 로고    scopus 로고
    • SIR-Spheres package insert (CR1507)
    • Sirtex Medical Limited, North Sydney, NSW, Australia
    • Sirtex Medical Limited: SIR-Spheres package insert (CR1507). In ᅟ. North Sydney, NSW, Australia: Sirtex Medical Limited; 2012.
    • (2012)
    • Sirtex Medical Limited1
  • 9
    • 0026623403 scopus 로고
    • Lung density and lung mass in emphysema
    • COI: 1:STN:280:DyaK38zitl2ntQ%3D%3D, PID: 1623752
    • Guenard H, Diallo MH, Laurent F, Vergeret J: Lung density and lung mass in emphysema.Chest 1992, 102:198–203.
    • (1992) Chest , vol.102 , pp. 198-203
    • Guenard, H.1    Diallo, M.H.2    Laurent, F.3    Vergeret, J.4
  • 10
    • 0021678656 scopus 로고
    • Mass estimates by computed tomography: physical density from CT numbers
    • COI: 1:STN:280:DyaL2M%2FhvFyjuw%3D%3D, PID: 6333158
    • Mull RT: Mass estimates by computed tomography: physical density from CT numbers.AJR Am J Roentgenol 1984, 143:1101–1104.
    • (1984) AJR Am J Roentgenol , vol.143 , pp. 1101-1104
    • Mull, R.T.1
  • 13
    • 23844557643 scopus 로고    scopus 로고
    • Determination of CT-to-density conversion relationship for image-based treatment planning systems
    • PID: 16112465
    • Saw CB, Loper A, Komanduri K, Combine T, Huq S, Scicutella C: Determination of CT-to-density conversion relationship for image-based treatment planning systems.Med Dosim 2005, 30:145–148.
    • (2005) Med Dosim , vol.30 , pp. 145-148
    • Saw, C.B.1    Loper, A.2    Komanduri, K.3    Combine, T.4    Huq, S.5    Scicutella, C.6
  • 15
    • 0031956279 scopus 로고    scopus 로고
    • Computed tomography and pulmonary measurements
    • COI: 1:STN:280:DyaK1czls12jsQ%3D%3D, PID: 9691874
    • Drummond GB: Computed tomography and pulmonary measurements.Br J Anaesth 1998, 80:665–671.
    • (1998) Br J Anaesth , vol.80 , pp. 665-671
    • Drummond, G.B.1
  • 17
    • 84859432761 scopus 로고    scopus 로고
    • Comparative analysis of hepatopulmonary shunt obtained from pretherapy 99mTc MAA scintigraphy and post-therapy 90Y Bremsstrahlung imaging in 90Y microsphere therapy
    • PID: 22395029
    • Jha AK, Zade AA, Rangarajan V, Purandare N, Shah SA, Agrawal A, Kulkarni SS, Shetty N: Comparative analysis of hepatopulmonary shunt obtained from pretherapy 99mTc MAA scintigraphy and post-therapy 90Y Bremsstrahlung imaging in 90Y microsphere therapy.Nucl Med Commun 2012, 33:486–490.
    • (2012) Nucl Med Commun , vol.33 , pp. 486-490
    • Jha, A.K.1    Zade, A.A.2    Rangarajan, V.3    Purandare, N.4    Shah, S.A.5    Agrawal, A.6    Kulkarni, S.S.7    Shetty, N.8
  • 19
    • 68649089947 scopus 로고    scopus 로고
    • Analysis of diaphragm movement during tidal breathing and during its activation while breath holding using MRI synchronized with spirometry
    • COI: 1:STN:280:DC%2BD1Mrgt1OmtQ%3D%3D, PID: 18637703
    • Kolar P, Neuwirth J, Sanda J, Suchanek V, Svata Z, Volejnik J, Pivec M: Analysis of diaphragm movement during tidal breathing and during its activation while breath holding using MRI synchronized with spirometry.Physiol Res 2009, 58:383–392.
    • (2009) Physiol Res , vol.58 , pp. 383-392
    • Kolar, P.1    Neuwirth, J.2    Sanda, J.3    Suchanek, V.4    Svata, Z.5    Volejnik, J.6    Pivec, M.7
  • 21
    • 79958766330 scopus 로고    scopus 로고
    • The importance of scatter correction for the assessment of lung shunting prior to yttrium-90 radioembolization therapy
    • PID: 21540757
    • O'Doherty J, Scuffham J, Hinton P: The importance of scatter correction for the assessment of lung shunting prior to yttrium-90 radioembolization therapy.Nucl Med Commun 2011, 32:628–634.
    • (2011) Nucl Med Commun , vol.32 , pp. 628-634
    • O'Doherty, J.1    Scuffham, J.2    Hinton, P.3
  • 23
    • 84947046842 scopus 로고    scopus 로고
    • Effect of CT acquisition parameters on a lung-mass estimation algorithm
    • Busse N, Erwin W, Pan T: Effect of CT acquisition parameters on a lung-mass estimation algorithm.J Nucl Med 2013, 54(Suppl 2):214.
    • (2013) J Nucl Med , vol.54 , pp. 214
    • Busse, N.1    Erwin, W.2    Pan, T.3
  • 25
    • 36949005413 scopus 로고    scopus 로고
    • 18 F-labeled resin microspheres as surrogates for 90Y resin microspheres used in the treatment of hepatic tumors: a radiolabeling and PET validation study
    • COI: 1:STN:280:DC%2BD2sjjtVOquw%3D%3D, PID: 18065846
    • Selwyn RG, Avila-Rodriguez MA, Converse AK, Hampel JA, Jaskowiak CJ, McDermott JC, Warner TF, Nickles RJ, Thomadsen BR: 18 F-labeled resin microspheres as surrogates for 90Y resin microspheres used in the treatment of hepatic tumors: a radiolabeling and PET validation study.Phys Med Biol 2007, 52:7397–7408.
    • (2007) Phys Med Biol , vol.52 , pp. 7397-7408
    • Selwyn, R.G.1    Avila-Rodriguez, M.A.2    Converse, A.K.3    Hampel, J.A.4    Jaskowiak, C.J.5    McDermott, J.C.6    Warner, T.F.7    Nickles, R.J.8    Thomadsen, B.R.9
  • 26
    • 84875003102 scopus 로고    scopus 로고
    • Post-90Y radioembolization PET/CT scan with respiratory gating using time-of-flight reconstruction
    • PID: 23370544
    • Mamawan MD, Ong SC, Senupe JM: Post-90Y radioembolization PET/CT scan with respiratory gating using time-of-flight reconstruction.J Nucl Med Technol 2013, 41:42.
    • (2013) J Nucl Med Technol , vol.41 , pp. 42
    • Mamawan, M.D.1    Ong, S.C.2    Senupe, J.M.3
  • 27
    • 84893428008 scopus 로고    scopus 로고
    • 90Y resin microsphere radioembolization
    • COI: 1:CAS:528:DC%2BC2cXit1Whuw%3D%3D, PID: 24198389
    • 90Y resin microsphere radioembolization.J Nucl Med 2013, 54:2191–2192.
    • (2013) J Nucl Med , vol.54 , pp. 2191-2192
    • Kao, Y.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.