메뉴 건너뛰기




Volumn 32, Issue 7, 2011, Pages 628-634

The importance of scatter correction for the assessment of lung shunting prior to yttrium-90 radioembolization therapy

Author keywords

lung shunt; microspheres; scatter correction

Indexed keywords

MACROSALB TC 99M; MICROSPHERE; YTTRIUM 90;

EID: 79958766330     PISSN: 01433636     EISSN: 14735628     Source Type: Journal    
DOI: 10.1097/MNM.0b013e3283463255     Document Type: Article
Times cited : (7)

References (31)
  • 1
    • 34247548022 scopus 로고    scopus 로고
    • Nuclear Medicine Imaging
    • Sharp PF, Gemmell HG, Murray AD, editors. Singapore: Springer
    • Sharp PF, Goatman KA. Nuclear Medicine Imaging. In: Sharp PF, Gemmell HG, Murray AD, editors. Practical nuclear medicine. Singapore: Springer; 2005. pp. 1-19.
    • (2005) Practical Nuclear Medicine , pp. 1-19
    • Sharp, P.F.1    Goatman, K.A.2
  • 2
    • 40649100263 scopus 로고    scopus 로고
    • FOXFIRE: A phase iii clinical trial of chemo-radio-embolisation as first-line treatment of liver metastases in patients with colorectal cancer
    • Sharma RA,Wasan HS, Love SB, Dutton S, Stokes JC, Smith JL. FOXFIRE: a phase iii clinical trial of chemo-radio-embolisation as first-line treatment of liver metastases in patients with colorectal cancer. Clin Oncol 2008; 20:261-263.
    • (2008) Clin Oncol , vol.20 , pp. 261-263
    • Sharma, R.A.1    Wasan, H.S.2    Love, S.B.3    Dutton, S.4    Stokes, J.C.5    Smith, J.L.6
  • 3
    • 0035700227 scopus 로고    scopus 로고
    • Randomised trial of SIR-Spheres plus chemotherapy vs. chemotherapy alone for treating patients with liver metastases from primary large bowel cancer
    • DOI 10.1023/A:1013569329846
    • Gray B, Van Hazel G, Hope M, Burton M, Moroz P, Anderson J, Gebski V. Randomised trial of SIR-Spheres plus chemotherapy vs. chemotherapy alone for treating patients with liver metastases from primary large bowel cancer. Ann Oncol 2001; 12:1711-1720. (Pubitemid 34105661)
    • (2001) Annals of Oncology , vol.12 , Issue.12 , pp. 1711-1720
    • Gray, B.1    Van Hazel, G.2    Hope, M.3    Burton, M.4    Moroz, P.5    Anderson, J.6    Gebski, V.7
  • 4
    • 0033825046 scopus 로고    scopus 로고
    • Treatment of colorectal liver metastases with SIR-Spheres plus chemotherapy
    • Gray B, Van Hazel G, Buck M. Treatment of colorectal liver metastases with SIR-Spheres plus chemotherapy. Gastrointest Cancer 2000; 3:249-257.
    • (2000) Gastrointest Cancer , vol.3 , pp. 249-257
    • Gray, B.1    Van Hazel, G.2    Buck, M.3
  • 7
    • 77951478799 scopus 로고    scopus 로고
    • Radioembolization (yttrium-90 microspheres) for primary and metastatic hepatic malignancies
    • Kennedy AS. Radioembolization (yttrium-90 microspheres) for primary and metastatic hepatic malignancies. Cancer J 2010; 16:163-175.
    • (2010) Cancer J , vol.16 , pp. 163-175
    • Kennedy, A.S.1
  • 8
    • 33750156243 scopus 로고    scopus 로고
    • Radioembolization with yttrium-90 microspheres: A state-of-the-art brachytherapy treatment for primary and secondary liver malignancies - Part 3: Comprehensive literature review and future direction
    • DOI 10.1097/01.RVI.0000236744.34720.73, PII 0000251820061000000002
    • Salem R, Thurston KG. Radioembolization with yttrium-90 microspheres: a state-of-the-art brachytherapy treatment for primary and secondary liver malignancies: part 3: comprehensive literature review and future direction. J Vasc Interv Radiol 2006; 17:1571-1593. (Pubitemid 44596135)
    • (2006) Journal of Vascular and Interventional Radiology , vol.17 , Issue.10 , pp. 1571-1593
    • Salem, R.1    Thurston, K.G.2
  • 9
    • 77950341103 scopus 로고    scopus 로고
    • Radiofrequency ablation after selective internal radiation therapy with yttrium90 microspheres in metastatic liver disease-is it feasible?
    • Hoffmann RT, Jakobs TF, Kubisch CH, Stemmler HJ, Trumm C, Tatsch K, et al. Radiofrequency ablation after selective internal radiation therapy with yttrium90 microspheres in metastatic liver disease-is it feasible? Eur J Radiol 2010; 74:199-205.
    • (2010) Eur J Radiol , vol.74 , pp. 199-205
    • Hoffmann, R.T.1    Jakobs, T.F.2    Kubisch, C.H.3    Stemmler, H.J.4    Trumm, C.5    Tatsch, K.6
  • 10
    • 34147111866 scopus 로고    scopus 로고
    • Coil embolization prevents GI ulcers during yttrium-90 hepatic radioembolization
    • Nutting CK, Coldwell D, Jones B. Coil embolization prevents GI ulcers during yttrium-90 hepatic radioembolization. J Vasc Interv Radiol Suppl 2004; 15:2.
    • (2004) J Vasc Interv Radiol Suppl , vol.15 , pp. 2
    • Nutting, C.K.1    Coldwell, D.2    Jones, B.3
  • 11
    • 0028783988 scopus 로고
    • Radiation pneumonitis after selective internal radiation treatment with intraarterial 90-yttrium-microspheres for inoperable hepatic tumors
    • Leung T, Lau W, Ho S. Radiation pneumonitis after selective internal radiation treatment with intraarterial 90-yttrium-microspheres for inoperable hepatic tumors. Int J Radiat Oncol Biol Phys 1995; 33:919-924.
    • (1995) Int J Radiat Oncol Biol Phys , vol.33 , pp. 919-924
    • Leung, T.1    Lau, W.2    Ho, S.3
  • 12
    • 42149093640 scopus 로고    scopus 로고
    • Trans-arterial hepatic radioembolisation for yttrium-90 microspheres
    • Murthy R, Habbu A, Salem R. Trans-arterial hepatic radioembolisation for yttrium-90 microspheres. Biomed Imaging Interv J 2006; 2:e43.
    • (2006) Biomed Imaging Interv J , vol.2
    • Murthy, R.1    Habbu, A.2    Salem, R.3
  • 13
    • 0031002101 scopus 로고    scopus 로고
    • Clinical evaluation of the partition model for estimating radiation doses from yttrium-90 microspheres in the treatment of hepatic cancer
    • DOI 10.1007/s002590050055
    • Ho S, Lau WY, Leung TW, Chan M, Johnson PJ, Li AK. Clinical evaluation of the partition model for estimating radiation doses from yttrium-90 microspheres in the treatment of hepatic cancer. Eur J Nuclear Med 1997; 24:293-298. (Pubitemid 27165858)
    • (1997) European Journal of Nuclear Medicine , vol.24 , Issue.3 , pp. 293-298
    • Ho, S.1    Lau, W.Y.2    Leung, T.W.T.3    Chan, M.4    Johnson, P.J.5    Li, A.K.C.6
  • 16
    • 74949105499 scopus 로고    scopus 로고
    • Radiation pneumonitis after radiotherapy for breast cancer
    • Bolke E, Matuschek C. Radiation pneumonitis after radiotherapy for breast cancer. N Engl J Med 2009; 361:e65.
    • (2009) N Engl J Med , vol.361
    • Bolke, E.1    Matuschek, C.2
  • 17
    • 26944449737 scopus 로고    scopus 로고
    • Radiation pneumonitis and pulmonary fibrosis in non-small-cell lung cancer: Pulmonary function, prediction, and prevention
    • DOI 10.1016/j.ijrobp.2005.03.047
    • Mehta V. Radiation pneumonitis and pulmonary fibrosis in non-small-cell lung cancer: pulmonary function, prediction, and prevention. Int J Oncol Biol Phys 2005; 63:5-24. (Pubitemid 41583538)
    • (2005) International Journal of Radiation Oncology Biology Physics , vol.63 , Issue.1 , pp. 5-24
    • Mehta, V.1
  • 19
    • 0025752507 scopus 로고
    • Activity quantitation in SPECT: A study of prereconstruction Metz filtering and use of the scatter degradation factor
    • King MA, Coleman M, Penney BC, Glick SJ. Activity quantitation in SPECT: a study of prereconstruction Metz filtering and use of the scatter degradation factor. Med Phys 1991; 18:184-189.
    • (1991) Med Phys , vol.18 , pp. 184-189
    • King, M.A.1    Coleman, M.2    Penney, B.C.3    Glick, S.J.4
  • 20
    • 0027955827 scopus 로고
    • A transmission-dependent method for scatter correction in SPECT
    • Meilke SR, Hutton SF, Bailey DL. A transmission-dependent method for scatter correction in SPECT. J Nucl Med 1994; 35:360-367. (Pubitemid 24048328)
    • (1994) Journal of Nuclear Medicine , vol.35 , Issue.2 , pp. 360-367
    • Meikle, S.R.1    Hutton, B.F.2    Bailey, D.L.3
  • 21
    • 0027644795 scopus 로고
    • A practical method for incorporating scatter in a projectorbackprojector for accurate scatter compensation in SPECT
    • Frey EC, Tsui BM. A practical method for incorporating scatter in a projectorbackprojector for accurate scatter compensation in SPECT. IEEE Trans Nucl Sci 1993; 40:1107-1116.
    • (1993) IEEE Trans Nucl Sci , vol.40 , pp. 1107-1116
    • Frey, E.C.1    Tsui, B.M.2
  • 23
    • 34047234576 scopus 로고    scopus 로고
    • Quantitative analysis in nuclear medicine imaging
    • Zaidi H, editor. New York, USA: Springer
    • Zaidi H, Koral KF. Quantitative analysis in nuclear medicine imaging. In: Zaidi H, editor. Scatter correction strategies in emission tomography. New York, USA: Springer; 2006. pp. 205-235.
    • (2006) Scatter Correction Strategies in Emission Tomography , pp. 205-235
    • Zaidi, H.1    Koral, K.F.2
  • 24
    • 0032916211 scopus 로고    scopus 로고
    • Relevance of accurate Monte Carlo modeling in nuclear medical imaging
    • DOI 10.1118/1.598559
    • Zaidi H. Relevance of accurate Monte Carlo modeling in nuclear medical imaging. Med Phys 1999; 26:574-608. (Pubitemid 29186278)
    • (1999) Medical Physics , vol.26 , Issue.4 , pp. 574-608
    • Zaidi, H.1
  • 25
    • 0027993152 scopus 로고
    • Simulation study of triple-energy-window scatter correction in combined Tl-201, Tc-99m SPECT
    • Ogawa K. Simulation study of triple-energy-window scatter correction in combined Tl-201, Tc-99m SPECT. Ann Nuc Med 1994; 8:277-281. (Pubitemid 24374358)
    • (1994) Annals of Nuclear Medicine , vol.8 , Issue.4 , pp. 277-281
    • Ogawa, K.1
  • 26
    • 79958772942 scopus 로고    scopus 로고
    • Use of scatter correction in quantitative I-123 MIBG scintigraphy for differentiating patients with parkinsonism: Results from phantom experiment and clinical study
    • Bai J, Hashimoto J, Suzuki T, Nakahara T, Kubo A, Ohira M, et al. Use of scatter correction in quantitative I-123 MIBG scintigraphy for differentiating patients with parkinsonism: results from phantom experiment and clinical study. World J Nucl Med 2007; 6:12-18.
    • (2007) World J Nucl Med , vol.6 , pp. 12-18
    • Bai, J.1    Hashimoto, J.2    Suzuki, T.3    Nakahara, T.4    Kubo, A.5    Ohira, M.6
  • 27
    • 0027142492 scopus 로고
    • Compton scatter compensation using the triple energy window method for single- and dualisotope SPECT
    • Ichihara T, Ogawa K, Motomura N, Kubo A, Hashimoto S. Compton scatter compensation using the triple energy window method for single- and dualisotope SPECT. J Nucl Med 1993; 34:2216-2220.
    • (1993) J Nucl Med , vol.34 , pp. 2216-2220
    • Ichihara, T.1    Ogawa, K.2    Motomura, N.3    Kubo, A.4    Hashimoto, S.5
  • 28
    • 0028058070 scopus 로고
    • Comparison of four scatter correction methods using Monte Carlo simulated source distributions
    • Ljungberg M, King MA, Hademenos GJ, Strand SE. Comparison of four scatter correction methods using Monte Carlo simulated source distributions. J Nucl Med 1994; 35:143-151. (Pubitemid 24018458)
    • (1994) Journal of Nuclear Medicine , vol.35 , Issue.1 , pp. 143-151
    • Ljungberg, M.1    King, M.A.2    Hademenos, G.J.3    Strand, S.-E.4
  • 29
    • 0029084607 scopus 로고
    • Comparative assessment of nine scatter correction methods based on spectral analysis using Monte Carlo simulations
    • Buvat I, Villafuerte M, Pokropek AT, Benali H, Di Paola R. Comparative assessment of nine scatter correction methods based on spectral analysis using Monte Carlo simulations. J Nucl Med 1995; 36:1476-1488.
    • (1995) J Nucl Med , vol.36 , pp. 1476-1488
    • Buvat, I.1    Villafuerte, M.2    Pokropek, A.T.3    Benali, H.4    Di Paola, R.5
  • 30
    • 0021166670 scopus 로고
    • Improved SPECT quantification using compensation for scattered photons
    • Jaszczak RJ, Greer KL, Floyd CE. Improved SPECT quantification using compensation for scattered photons. J Nucl Med 1984; 25:893-900. (Pubitemid 14057523)
    • (1984) Journal of Nuclear Medicine , vol.25 , Issue.8 , pp. 893-900
    • Jaszczak, R.J.1    Greer, K.L.2    Floyd Jr., C.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.