메뉴 건너뛰기




Volumn 60, Issue 7, 2014, Pages 945-953

Harmonization of measurement results of the alcohol biomarker carbohydrate-deficient transferrin by use of the toolbox of technical procedures of the international Consortium for harmonization of Clinical Laboratory results

Author keywords

[No Author keywords available]

Indexed keywords

ALCOHOL; BIOLOGICAL MARKER; CARBOHYDRATE DEFICIENT TRANSFERRIN; PROTEIN; TRISIALOTRANSFERRIN; UNCLASSIFIED DRUG;

EID: 84903728370     PISSN: 00099147     EISSN: 15308561     Source Type: Journal    
DOI: 10.1373/clinchem.2014.221531     Document Type: Article
Times cited : (30)

References (23)
  • 1
    • 0026331891 scopus 로고
    • Carbohydrate-deficient transferrin in serum: A new marker of potentially harmful alcohol consumption reviewed
    • Stibler H. Carbohydrate-deficient transferrin in serum: a new marker of potentially harmful alcohol consumption reviewed. Clin Chem 1991;37:2029-37.
    • (1991) Clin Chem , vol.37 , pp. 2029-2037
    • Stibler, H.1
  • 2
    • 0028670369 scopus 로고
    • Purification of isotransferrins by concanavalin a sepharose chromatography and preparative isoelectric focusing
    • Van Noort WL, de Jong G, Van Eijk HG. Purification of isotransferrins by concanavalin a sepharose chromatography and preparative isoelectric focusing. Eur J Clin Chem Clin Biochem 1994;32:885-92.
    • (1994) Eur J Clin Chem Clin Biochem , vol.32 , pp. 885-892
    • Van Noort, W.L.1    De Jong, G.2    Van Eijk, H.G.3
  • 4
    • 47649095038 scopus 로고    scopus 로고
    • HPLC and mass spectrometric characterization of a candidate reference material for the alcohol biomarker carbohydrate-deficient transferrin
    • Oberrauch W, Bergman A-C, Helander A. HPLC and mass spectrometric characterization of a candidate reference material for the alcohol biomarker carbohydrate-deficient transferrin. Clin Chim Acta 2008;395:142-5.
    • (2008) Clin Chim Acta , vol.395 , pp. 142-145
    • Oberrauch, W.1    Bergman, A.-C.2    Helander, A.3
  • 5
    • 37249068563 scopus 로고    scopus 로고
    • Influence of alcohol use, ethnicity, age, gender, BMI and smoking on the serum transferrin glycoform pattern: Implications for use of carbohydrate-deficient transferrin (CDT) as alcohol biomarker
    • Bergström JP, Helander A. Influence of alcohol use, ethnicity, age, gender, BMI and smoking on the serum transferrin glycoform pattern: implications for use of carbohydrate-deficient transferrin (CDT) as alcohol biomarker. Clin Chim Acta 2008;388:59-67.
    • (2008) Clin Chim Acta , vol.388 , pp. 59-67
    • Bergström, J.P.1    Helander, A.2
  • 6
    • 0034960523 scopus 로고    scopus 로고
    • Interference of transferrin isoforms types with carbohydrate-deficient transferrin quantification in the identification of alcohol abuse
    • Helander A, Eriksson G, Stibler H, Jeppsson J-O. Interference of transferrin isoforms types with carbohydrate-deficient transferrin quantification in the identification of alcohol abuse. Clin Chem 2001;47:1225-33.
    • (2001) Clin Chem , vol.47 , pp. 1225-1233
    • Helander, A.1    Eriksson, G.2    Stibler, H.3    Jeppsson, J.-O.4
  • 7
    • 0027429940 scopus 로고
    • Carbohydrate-deficient transferrin quantified by HPLC to determine heavy consumption of alcohol
    • Jeppsson J-O, Kristensson H, Fimiani C. Carbohydrate-deficient transferrin quantified by HPLC to determine heavy consumption of alcohol. Clin Chem 1993;39:2115-20.
    • (1993) Clin Chem , vol.39 , pp. 2115-2120
    • Jeppsson, J.-O.1    Kristensson, H.2    Fimiani, C.3
  • 8
    • 0029858953 scopus 로고    scopus 로고
    • Carbohydrate-deficient transferrin and gamma-glutamyl transferase levels during disulfiram therapy
    • Helander A, Carlsson S. Carbohydrate-deficient transferrin and gamma-glutamyl transferase levels during disulfiram therapy. Alcohol Clin Exp Res 1996;20:1202-5.
    • (1996) Alcohol Clin Exp Res , vol.20 , pp. 1202-1205
    • Helander, A.1    Carlsson, S.2
  • 9
    • 34249909809 scopus 로고    scopus 로고
    • Development and multicenter evaluation of the N Latex CDT direct immunonephelometric assay for serum carbohydrate-deficient transferrin
    • Delanghe JR, Helander A, Wielders JP, Pekelharing JM, Roth HJ, Schellenberg F, et al. Development and multicenter evaluation of the N Latex CDT direct immunonephelometric assay for serum carbohydrate-deficient transferrin. Clin Chem 2007;53:115-21.
    • (2007) Clin Chem , vol.53 , pp. 115-121
    • Delanghe, J.R.1    Helander, A.2    Wielders, J.P.3    Pekelharing, J.M.4    Roth, H.J.5    Schellenberg, F.6
  • 10
    • 34247380374 scopus 로고    scopus 로고
    • Toward standardization of carbohydrate-deficient transferrin (CDT) measurements: I. Analyte definition and proposal of a candidate reference method
    • Jeppsson J-O, Arndt T, Schellenberg F, Wielders J P M, Anton RF, Whitfield JB, Helander A. Toward standardization of carbohydrate-deficient transferrin (CDT) measurements: I. Analyte definition and proposal of a candidate reference method. Clin Chem Lab Med 2007;45:558-62.
    • (2007) Clin Chem Lab Med , vol.45 , pp. 558-562
    • Jeppsson, J.-O.1    Arndt, T.2    Schellenberg, F.3    Wielders, J.P.M.4    Anton, R.F.5    Whitfield, J.B.6    Helander, A.7
  • 11
    • 0242267940 scopus 로고    scopus 로고
    • Improved HPLC method for carbohydrate-deficient transferrin in serum
    • Helander A, Husa A, Jeppsson J-O. Improved HPLC method for carbohydrate-deficient transferrin in serum. Clin Chem 2003;49:1881-90.
    • (2003) Clin Chem , vol.49 , pp. 1881-1890
    • Helander, A.1    Husa, A.2    Jeppsson, J.-O.3
  • 12
    • 78751630075 scopus 로고    scopus 로고
    • Toward standardization of carbohydrate-deficient transferrin (CDT) measurements: II. Performance of a laboratory network running the HPLC candidate reference measurement procedure and evaluation of a candidate reference material
    • Helander A, Wielders JP, Jeppsson J-O, Weykamp C, Siebelder C, Anton RF, et al. Toward standardization of carbohydrate-deficient transferrin (CDT) measurements: II. Performance of a laboratory network running the HPLC candidate reference measurement procedure and evaluation of a candidate reference material. Clin Chem Lab Med 2010;48:1585-92.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 1585-1592
    • Helander, A.1    Wielders, J.P.2    Jeppsson, J.-O.3    Weykamp, C.4    Siebelder, C.5    Anton, R.F.6
  • 13
    • 84882268474 scopus 로고    scopus 로고
    • Toward standardization of carbohydrate-deficient transferrin (CDT) measurements: III. Performance of native serum and serum spiked with disialotransferrin proves that harmonization of CDT assays is possible
    • Weykamp C, Wielders JP, Helander A, Anton RF, Bianchi V, Jeppsson J-O, et al. Toward standardization of carbohydrate-deficient transferrin (CDT) measurements: III. Performance of native serum and serum spiked with disialotransferrin proves that harmonization of CDT assays is possible. Clin Chem Lab Med 2013;51:991-6.
    • (2013) Clin Chem Lab Med , vol.51 , pp. 991-996
    • Weykamp, C.1    Wielders, J.P.2    Helander, A.3    Anton, R.F.4    Bianchi, V.5    Jeppsson, J.-O.6
  • 15
    • 84901624063 scopus 로고    scopus 로고
    • Accessed March 2014; reaccessed May 2014
    • AACC. Clinical Laboratory Test Harmonization. www.harmonization. net (Accessed March 2014; reaccessed May 2014). See "Toolbox of technical procedures to be considered when developing a process to achieve harmonization for a measurand."
    • Clinical Laboratory Test Harmonization
  • 16
    • 33748952248 scopus 로고    scopus 로고
    • Capillary zone electrophoresis determination of carbohydratedeficient transferrin using the new CEofix reagents under high resolution conditions
    • Joneli J, Lanz C, Thormann W. Capillary zone electrophoresis determination of carbohydratedeficient transferrin using the new CEofix reagents under high resolution conditions. J Chromatogr A 2006;1130:272-80.
    • (2006) J Chromatogr A , vol.1130 , pp. 272-280
    • Joneli, J.1    Lanz, C.2    Thormann, W.3
  • 17
    • 77957754962 scopus 로고    scopus 로고
    • Evaluation of capillary electrophoresis assay for CDT on Sebia's Capillarys System: Intra and inter laboratory precision, reference interval and cut-off
    • Schellenberg F, Wielders JP. Evaluation of capillary electrophoresis assay for CDT on Sebia's Capillarys System: intra and inter laboratory precision, reference interval and cut-off. Clin Chim Acta 2010;411:1883-93.
    • (2010) Clin Chim Acta , vol.411 , pp. 1883-1893
    • Schellenberg, F.1    Wielders, J.P.2
  • 18
    • 33746736849 scopus 로고    scopus 로고
    • Determination of carbohydrate-deficient transferrin in human serum using the Bio-Rad %CDT by HPLC test
    • Helander A, Bergström JP. Determination of carbohydrate-deficient transferrin in human serum using the Bio-Rad %CDT by HPLC test. Clin Chim Acta 2006;371:187-90.
    • (2006) Clin Chim Acta , vol.371 , pp. 187-190
    • Helander, A.1    Bergström, J.P.2
  • 19
    • 80054881494 scopus 로고    scopus 로고
    • Comparative evaluation of capillary zone electrophoresis and HPLC in the determination of carbohydrate-deficient transferrin
    • Daves M, Cemini R, Floreani M, Pusceddu I, Cosio G, Lippi G. Comparative evaluation of capillary zone electrophoresis and HPLC in the determination of carbohydrate-deficient transferrin. Clin Chem Lab Med 2011;49:1677-80.
    • (2011) Clin Chem Lab Med , vol.49 , pp. 1677-1680
    • Daves, M.1    Cemini, R.2    Floreani, M.3    Pusceddu, I.4    Cosio, G.5    Lippi, G.6
  • 20
    • 0021045350 scopus 로고
    • A new biometrical procedure for testing the equality of measurements from two different analytical methods: Application of linear regression procedures for method comparison studies in clinical chemistry
    • Passing H, Bablok W. A new biometrical procedure for testing the equality of measurements from two different analytical methods: application of linear regression procedures for method comparison studies in clinical chemistry. J Clin Chem Clin Biochem 1983;21:709-20.
    • (1983) J Clin Chem Clin Biochem , vol.21 , pp. 709-720
    • Passing, H.1    Bablok, W.2
  • 21
    • 0031970811 scopus 로고    scopus 로고
    • Characterization and evaluation of external quality assessment scheme serum
    • Middle JG, Libeer J-C, Malakhov V, Penttila I. Characterization and evaluation of external quality assessment scheme serum. Clin Chem Lab Med 1998;36:119-30.
    • (1998) Clin Chem Lab Med , vol.36 , pp. 119-130
    • Middle, J.G.1    Libeer, J.-C.2    Malakhov, V.3    Penttila, I.4
  • 22
    • 0031031761 scopus 로고    scopus 로고
    • Proposal for setting generally applicable quality goals solely based on biology
    • Fraser CG, Hyltoft Peterson P, Libeer JC, Ricos C. Proposal for setting generally applicable quality goals solely based on biology. Ann Clin Biochem 1997;34:8-12.
    • (1997) Ann Clin Biochem , vol.34 , pp. 8-12
    • Fraser, C.G.1    Peterson, P.H.2    Libeer, J.C.3    Ricos, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.