메뉴 건너뛰기




Volumn 24, Issue SUPPL.1, 2014, Pages

Comparison of vertebroplasty and kyphoplasty in the treatment of osteoporotic vertebral compression fractures with intravertebral clefts

Author keywords

Intravertebral cleft; Kyphoplasty; Vertebral compression fracture; Vertebroplasty

Indexed keywords

AGED; ANALGESIA; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DISEASE ASSOCIATION; FEMALE; HUMAN; INTERMETHOD COMPARISON; INTRAVERTEBRAL CLEFT; KYPHOPLASTY; MAJOR CLINICAL STUDY; MALE; NUCLEAR MAGNETIC RESONANCE; NUCLEAR MAGNETIC RESONANCE IMAGING; OSTEOPOROTIC VERTEBRAL COMPRESSION FRACTURE; PERCUTANEOUS VERTEBROPLASTY; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SCORING SYSTEM; SPINE FRACTURE; SURGICAL TECHNIQUE; VERTEBRA BODY; VISUAL ANALOG SCALE; ADVERSE EFFECTS; BACK PAIN; COMPARATIVE STUDY; FRACTURES, COMPRESSION; OSTEOPOROTIC FRACTURES; PAIN MEASUREMENT; PROCEDURES; SPINAL FRACTURES; TREATMENT OUTCOME;

EID: 84903724466     PISSN: 16338065     EISSN: 14321068     Source Type: Journal    
DOI: 10.1007/s00590-013-1374-z     Document Type: Article
Times cited : (41)

References (30)
  • 1
    • 0018131722 scopus 로고
    • The intravertebral vacuum cleft: A sign of ischemic vertebral collapse
    • 1:STN:280:DyaE1M%2FhtlWmug%3D%3D 693884
    • Maldague BE, Noel HM, Malghem JJ (1978) The intravertebral vacuum cleft: a sign of ischemic vertebral collapse. Radiology 129(1):23-29
    • (1978) Radiology , vol.129 , Issue.1 , pp. 23-29
    • Maldague, B.E.1    Noel, H.M.2    Malghem, J.J.3
  • 2
    • 0019729193 scopus 로고
    • Kummell disease: Report of a case with serial radiographs
    • 1:STN:280:DyaL38%2FjvVGlsA%3D%3D 7291557
    • Brower AC, Downey EF Jr (1981) Kummell disease: report of a case with serial radiographs. Radiology 141(2):363-364
    • (1981) Radiology , vol.141 , Issue.2 , pp. 363-364
    • Brower, A.C.1    Downey Jr., E.F.2
  • 3
    • 0027203830 scopus 로고
    • Delayed post-traumatic vertebral collapse (Kummell's disease): Case report with serial radiographs, computed tomographic scans, and bone scans
    • 8362333 10.1097/00007632-199307000-00019
    • Van Eenenaam DP, El-khoury GY (1993) Delayed post-traumatic vertebral collapse (Kummell's disease): case report with serial radiographs, computed tomographic scans, and bone scans. Spine 18(9):1236-1241
    • (1993) Spine , vol.18 , Issue.9 , pp. 1236-1241
    • Van Eenenaam, D.P.1    El-Khoury, G.Y.2
  • 4
    • 0036847224 scopus 로고    scopus 로고
    • Intravertebral clefts opacified during vertebroplasty: Pathogenesis, technical implications, and prognostic significance
    • 12427615
    • Lane JI, Maus TP, Wald JT, Thielen KR, Bobra S, Luetmer PH (2002) Intravertebral clefts opacified during vertebroplasty: pathogenesis, technical implications, and prognostic significance. Am J Neuroradiol 23(10):1642-1646
    • (2002) Am J Neuroradiol , vol.23 , Issue.10 , pp. 1642-1646
    • Lane, J.I.1    Maus, T.P.2    Wald, J.T.3    Thielen, K.R.4    Bobra, S.5    Luetmer, P.H.6
  • 5
    • 0032532436 scopus 로고    scopus 로고
    • Vertebral pseudarthrosis in the osteoporotic spine
    • 1:STN:280:DyaK1M%2FhvV2ksg%3D%3D 9802162 10.1097/00007632-199810150-00011
    • Hasegawa K, Homma T, Uchiyama S, Takahashi H (1998) Vertebral pseudarthrosis in the osteoporotic spine. Spine 23(20):2201-2206
    • (1998) Spine , vol.23 , Issue.20 , pp. 2201-2206
    • Hasegawa, K.1    Homma, T.2    Uchiyama, S.3    Takahashi, H.4
  • 6
    • 0022548267 scopus 로고
    • The intravertebral vacuum phenomenon
    • 1:STN:280:DyaL2s%2FhvV2mug%3D%3D 3764471 10.1007/BF00355102
    • Kumpan W, Salomonowitz E, Seidl G, Wittich GR (1986) The intravertebral vacuum phenomenon. Skeletal Radiol 15(6):444-447
    • (1986) Skeletal Radiol , vol.15 , Issue.6 , pp. 444-447
    • Kumpan, W.1    Salomonowitz, E.2    Seidl, G.3    Wittich, G.R.4
  • 7
    • 64049114586 scopus 로고    scopus 로고
    • The intravertebral cleft in acute osteoporotic fractures: Fluid in magnetic resonance imaging-vacuum in computed tomography?
    • 10.1097/BRS.0b013e318193ca06 19139659 10.1097/BRS.0b013e318193ca06
    • Linn J, Birkenmaier C, Hoffmann RT, Reiser M, Baur-Melnyk A (2009) The intravertebral cleft in acute osteoporotic fractures: fluid in magnetic resonance imaging-vacuum in computed tomography? Spine 34(2):E88-E93. doi: 10.1097/BRS.0b013e318193ca06
    • (2009) Spine , vol.34 , Issue.2
    • Linn, J.1    Birkenmaier, C.2    Hoffmann, R.T.3    Reiser, M.4    Baur-Melnyk, A.5
  • 8
    • 35848953165 scopus 로고    scopus 로고
    • Alteration of disc vacuum contents during prolonged supine positioning: Evaluation with MR image
    • 10.1097/BRS.0b013e318158cb49 17978662 10.1097/BRS.0b013e318158cb49
    • Wang HJ, Chen BB, Yu CW, Hsu CY, Shih TT (2007) Alteration of disc vacuum contents during prolonged supine positioning: evaluation with MR image. Spine 32(23):2610-2615. doi: 10.1097/BRS.0b013e318158cb49
    • (2007) Spine , vol.32 , Issue.23 , pp. 2610-2615
    • Wang, H.J.1    Chen, B.B.2    Yu, C.W.3    Hsu, C.Y.4    Shih, T.T.5
  • 9
    • 41049115200 scopus 로고    scopus 로고
    • Kummell's disease: A case report and literature review
    • 10.1097/BRS.0b013e3181657f31 18317183 10.1097/BRS.0b013e3181657f31
    • Swartz K, Fee D (2008) Kummell's disease: a case report and literature review. Spine 33(5):E152-E155. doi: 10.1097/BRS.0b013e3181657f31
    • (2008) Spine , vol.33 , Issue.5
    • Swartz, K.1    Fee, D.2
  • 11
    • 62349121784 scopus 로고    scopus 로고
    • Efficacy and safety of balloon kyphoplasty compared with non-surgical care for vertebral compression fracture (FREE): A randomised controlled trial
    • 10.1016/S0140-6736(09)60010-6 19246088 10.1016/S0140-6736(09)60010-6
    • Wardlaw D, Cummings SR, Van Meirhaeghe J, Bastian L, Tillman JB, Ranstam J, Eastell R, Shabe P, Talmadge K, Boonen S (2009) Efficacy and safety of balloon kyphoplasty compared with non-surgical care for vertebral compression fracture (FREE): a randomised controlled trial. Lancet 373(9668):1016-1024. doi: 10.1016/S0140-6736(09)60010-6
    • (2009) Lancet , vol.373 , Issue.9668 , pp. 1016-1024
    • Wardlaw, D.1    Cummings, S.R.2    Van Meirhaeghe, J.3    Bastian, L.4    Tillman, J.B.5    Ranstam, J.6    Eastell, R.7    Shabe, P.8    Talmadge, K.9    Boonen, S.10
  • 12
    • 84879078105 scopus 로고    scopus 로고
    • A Randomized trial of balloon kyphoplasty and non-surgical management for treating acute vertebral compression fractures: Vertebral body kyphosis correction and surgical parameters
    • 10.1097/BRS.0b013e31828e8e22 3678891 23446769
    • Van Meirhaeghe J, Bastian L, Boonen S, Ranstam J, Tillman JB, Wardlaw D (2013) A Randomized trial of balloon kyphoplasty and non-surgical management for treating acute vertebral compression fractures: vertebral body kyphosis correction and surgical parameters. Spine. doi: 10.1097/BRS.0b013e31828e8e22
    • (2013) Spine
    • Van Meirhaeghe, J.1    Bastian, L.2    Boonen, S.3    Ranstam, J.4    Tillman, J.B.5    Wardlaw, D.6
  • 13
    • 33645756840 scopus 로고    scopus 로고
    • Kyphosis reduction and the rate of cement leaks after vertebroplasty of intravertebral clefts
    • 10.1007/s00330-005-0056-6 16314915 10.1007/s00330-005-0056-6
    • Krauss M, Hirschfelder H, Tomandl B, Lichti G, Bar I (2006) Kyphosis reduction and the rate of cement leaks after vertebroplasty of intravertebral clefts. Eur Radiol 16(5):1015-1021. doi: 10.1007/s00330-005-0056-6
    • (2006) Eur Radiol , vol.16 , Issue.5 , pp. 1015-1021
    • Krauss, M.1    Hirschfelder, H.2    Tomandl, B.3    Lichti, G.4    Bar, I.5
  • 14
    • 33847187044 scopus 로고    scopus 로고
    • Importance of intravertebral fracture clefts in vertebroplasty outcome
    • 10.2214/AJR.06.0542 10.2214/AJR.06.0542
    • Wiggins MC, Sehizadeh M, Pilgram TK, Gilula LA (2007) Importance of intravertebral fracture clefts in vertebroplasty outcome. Am J Roentgenol 188(3):634-640. doi: 10.2214/AJR.06.0542
    • (2007) Am J Roentgenol , vol.188 , Issue.3 , pp. 634-640
    • Wiggins, M.C.1    Sehizadeh, M.2    Pilgram, T.K.3    Gilula, L.A.4
  • 15
    • 33646835942 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for vertebral compression fractures with and without intravertebral clefts
    • 10.1302/0301-620x.88b5.17345 16645109 10.1302/0301-620X.88B5.17345
    • Ha KY, Lee JS, Kim KW, Chon JS (2006) Percutaneous vertebroplasty for vertebral compression fractures with and without intravertebral clefts. J Bone Joint Surg Br 88(5):629-633. doi: 10.1302/0301-620x.88b5.17345
    • (2006) J Bone Joint Surg Br , vol.88 , Issue.5 , pp. 629-633
    • Ha, K.Y.1    Lee, J.S.2    Kim, K.W.3    Chon, J.S.4
  • 16
    • 77955554091 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for intravertebral cleft: Analysis of therapeutic effects and outcome predictors
    • 10.1007/s00256-009-0866-8 20143063 10.1007/s00256-009-0866-8
    • Kim YJ, Lee JW, Kim KJ, Chung SK, Kim HJ, Park JM, Kang HS (2010) Percutaneous vertebroplasty for intravertebral cleft: analysis of therapeutic effects and outcome predictors. Skeletal Radiol 39(8):757-766. doi: 10.1007/s00256-009-0866-8
    • (2010) Skeletal Radiol , vol.39 , Issue.8 , pp. 757-766
    • Kim, Y.J.1    Lee, J.W.2    Kim, K.J.3    Chung, S.K.4    Kim, H.J.5    Park, J.M.6    Kang, H.S.7
  • 17
    • 78649424537 scopus 로고    scopus 로고
    • Osteoporotic vertebral compression fractures with an intravertebral cleft treated by percutaneous balloon kyphoplasty
    • 10.1302/0301-620X.92B11.24671 1:STN:280:DC%2BC3cbjsVymtA%3D%3D 21037351 10.1302/0301-620X.92B11.24671
    • Wang G, Yang H, Chen K (2010) Osteoporotic vertebral compression fractures with an intravertebral cleft treated by percutaneous balloon kyphoplasty. J Bone Joint Surg Br 92(11):1553-1557. doi: 10.1302/0301-620X. 92B11.24671
    • (2010) J Bone Joint Surg Br , vol.92 , Issue.11 , pp. 1553-1557
    • Wang, G.1    Yang, H.2    Chen, K.3
  • 18
    • 84872169167 scopus 로고    scopus 로고
    • Outcomes of percutaneous kyphoplasty in patients with intravertebral vacuum cleft
    • 23409577
    • Wu AM, Ni WF, Weng W, Chi YL, Xu HZ, Wang XY (2012) Outcomes of percutaneous kyphoplasty in patients with intravertebral vacuum cleft. Acta Orthop Belg 78(6):790-795
    • (2012) Acta Orthop Belg , vol.78 , Issue.6 , pp. 790-795
    • Wu, A.M.1    Ni, W.F.2    Weng, W.3    Chi, Y.L.4    Xu, H.Z.5    Wang, X.Y.6
  • 19
    • 75649136881 scopus 로고    scopus 로고
    • Balloon kyphoplasty in the treatment of osteoporotic vertebral compression fracture nonunion
    • 10.3928/01477447-20091124-28 20055352 10.3928/01477447-20091124-28
    • Yang H, Wang G, Liu J, Ebraheim NA, Niu G, Hiltner L, Lee AH, Tang T (2010) Balloon kyphoplasty in the treatment of osteoporotic vertebral compression fracture nonunion. Orthopedics 33(1):24. doi: 10.3928/01477447- 20091124-28
    • (2010) Orthopedics , vol.33 , Issue.1 , pp. 24
    • Yang, H.1    Wang, G.2    Liu, J.3    Ebraheim, N.A.4    Niu, G.5    Hiltner, L.6    Lee, A.H.7    Tang, T.8
  • 20
    • 0035879089 scopus 로고    scopus 로고
    • New technologies in spine: Kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures
    • 1:STN:280:DC%2BD3Mvht1Onsw%3D%3D 11462078 10.1097/00007632-200107150- 00002
    • Garfin SR, Yuan HA, Reiley MA (2001) New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures. Spine 26(14):1511-1515
    • (2001) Spine , vol.26 , Issue.14 , pp. 1511-1515
    • Garfin, S.R.1    Yuan, H.A.2    Reiley, M.A.3
  • 21
    • 0031809099 scopus 로고    scopus 로고
    • The linear intravertebral vacuum: A sign of benign vertebral collapse
    • 10.2214/ajr.170.6.9609175 1:STN:280:DyaK1c3ntVegug%3D%3D 10.2214/ajr.170.6.9609175
    • Bhalla S, Reinus WR (1998) The linear intravertebral vacuum: a sign of benign vertebral collapse. Am J Roentgenol 170(6):1563-1569. doi: 10.2214/ajr.170.6.9609175
    • (1998) Am J Roentgenol , vol.170 , Issue.6 , pp. 1563-1569
    • Bhalla, S.1    Reinus, W.R.2
  • 22
    • 36448946505 scopus 로고    scopus 로고
    • Relationship between cement distribution pattern and new compression fracture after percutaneous vertebroplasty
    • 10.2214/ajr.07.2186 10.2214/AJR.07.2186
    • Tanigawa N, Komemushi A, Kariya S, Kojima H, Shomura Y, Omura N, Sawada S (2007) Relationship between cement distribution pattern and new compression fracture after percutaneous vertebroplasty. Am J Roentgenol 189(6):W348-W352. doi: 10.2214/ajr.07.2186
    • (2007) Am J Roentgenol , vol.189 , Issue.6
    • Tanigawa, N.1    Komemushi, A.2    Kariya, S.3    Kojima, H.4    Shomura, Y.5    Omura, N.6    Sawada, S.7
  • 23
    • 0344286184 scopus 로고    scopus 로고
    • Intravertebral vacuum phenomenon following fractures: CT study on frequency and etiology
    • 1:STN:280:DC%2BD3c%2FlsFCqug%3D%3D 10589581 10.1097/00004728-199911000- 00030
    • Stabler A, Schneider P, Link TM, Schops P, Springer OS, Durr HR, Reiser M (1999) Intravertebral vacuum phenomenon following fractures: CT study on frequency and etiology. J Comput Assist Tomogr 23(6):976-980
    • (1999) J Comput Assist Tomogr , vol.23 , Issue.6 , pp. 976-980
    • Stabler, A.1    Schneider, P.2    Link, T.M.3    Schops, P.4    Springer, O.S.5    Durr, H.R.6    Reiser, M.7
  • 24
    • 84861100251 scopus 로고    scopus 로고
    • The intravertebral cleft in painful long-standing osteoporotic vertebral compression fractures treated with percutaneous vertebroplasty: Diagnostic assessment and clinical significance
    • 10.1097/BRS.0b013e318238bf22 22020580 10.1097/BRS.0b013e318238bf22
    • Nieuwenhuijse MJ, van Rijswijk CS, van Erkel AR, Dijkstra SP (2012) The intravertebral cleft in painful long-standing osteoporotic vertebral compression fractures treated with percutaneous vertebroplasty: diagnostic assessment and clinical significance. Spine 37(11):974-981. doi: 10.1097/BRS.0b013e318238bf22
    • (2012) Spine , vol.37 , Issue.11 , pp. 974-981
    • Nieuwenhuijse, M.J.1    Van Rijswijk, C.S.2    Van Erkel, A.R.3    Dijkstra, S.P.4
  • 25
    • 33644848329 scopus 로고    scopus 로고
    • Kyphoplasty reduction of osteoporotic vertebral compression fractures: Correction of local kyphosis versus overall sagittal alignment
    • 10.1097/01.brs.0000200036.08679.1e 16481954 10.1097/01.brs.0000200036. 08679.1e
    • Pradhan BB, Bae HW, Kropf MA, Patel VV, Delamarter RB (2006) Kyphoplasty reduction of osteoporotic vertebral compression fractures: correction of local kyphosis versus overall sagittal alignment. Spine 31(4):435-441. doi: 10.1097/01.brs.0000200036.08679.1e
    • (2006) Spine , vol.31 , Issue.4 , pp. 435-441
    • Pradhan, B.B.1    Bae, H.W.2    Kropf, M.A.3    Patel, V.V.4    Delamarter, R.B.5
  • 26
    • 84871927700 scopus 로고    scopus 로고
    • Pain reduction following vertebroplasty and kyphoplasty
    • 10.1007/s00264-012-1709-0 3532655 23142863 10.1007/s00264-012-1709-0
    • Dong R, Chen L, Tang T, Gu Y, Luo Z, Shi Q, Li X, Zhou Q, Yang H (2013) Pain reduction following vertebroplasty and kyphoplasty. Int Orthop 37(1):83-87. doi: 10.1007/s00264-012-1709-0
    • (2013) Int Orthop , vol.37 , Issue.1 , pp. 83-87
    • Dong, R.1    Chen, L.2    Tang, T.3    Gu, Y.4    Luo, Z.5    Shi, Q.6    Li, X.7    Zhou, Q.8    Yang, H.9
  • 27
    • 84891886882 scopus 로고    scopus 로고
    • A meta-analysis of balloon kyphoplasty compared to percutaneous vertebroplasty for treating osteoporotic vertebral compression fractures
    • 10.1016/j.jocn.2012.05.038
    • Xing D, Ma JX, Ma XL, Wang J, Xu WG, Chen Y, Song DH (2013) A meta-analysis of balloon kyphoplasty compared to percutaneous vertebroplasty for treating osteoporotic vertebral compression fractures. J Clin Neurosc Off J Neurosurg Soc Australas. doi: 10.1016/j.jocn.2012.05.038
    • (2013) J Clin Neurosc off J Neurosurg Soc Australas
    • Xing, D.1    Ma, J.X.2    Ma, X.L.3    Wang, J.4    Xu, W.G.5    Chen, Y.6    Song, D.H.7
  • 28
    • 33745240935 scopus 로고    scopus 로고
    • Leakage of polymethylmethacrylate in percutaneous vertebroplasty: Comparison of osteoporotic vertebral compression fractures with and without an intravertebral vacuum cleft
    • 16778629 10.1097/00004728-200605000-00025
    • Jung JY, Lee MH, Ahn JM (2006) Leakage of polymethylmethacrylate in percutaneous vertebroplasty: comparison of osteoporotic vertebral compression fractures with and without an intravertebral vacuum cleft. J Comput Assist Tomogr 30(3):501-506
    • (2006) J Comput Assist Tomogr , vol.30 , Issue.3 , pp. 501-506
    • Jung, J.Y.1    Lee, M.H.2    Ahn, J.M.3
  • 29
    • 38149041832 scopus 로고    scopus 로고
    • Intravertebral pressure during vertebroplasty and balloon kyphoplasty: An in vitro study
    • 10.1097/BRS.0b013e3181606139 18197103 10.1097/BRS.0b013e3181606139
    • Weisskopf M, Ohnsorge JA, Niethard FU (2008) Intravertebral pressure during vertebroplasty and balloon kyphoplasty: an in vitro study. Spine 33(2):178-182. doi: 10.1097/BRS.0b013e3181606139
    • (2008) Spine , vol.33 , Issue.2 , pp. 178-182
    • Weisskopf, M.1    Ohnsorge, J.A.2    Niethard, F.U.3
  • 30
    • 0036790721 scopus 로고    scopus 로고
    • An in vivo comparison of the potential for extravertebral cement leak after vertebroplasty and kyphoplasty
    • 10.1097/01.brs.0000025689.39941.26 12394934 10.1097/00007632-200210010- 00018
    • Phillips FM, Todd Wetzel F, Lieberman I, Campbell-Hupp M (2002) An in vivo comparison of the potential for extravertebral cement leak after vertebroplasty and kyphoplasty. Spine 27(19):2173-2178. doi: 10.1097/01.brs.0000025689.39941.26
    • (2002) Spine , vol.27 , Issue.19 , pp. 2173-2178
    • Phillips, F.M.1    Todd Wetzel, F.2    Lieberman, I.3    Campbell-Hupp, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.