메뉴 건너뛰기




Volumn 181, Issue 9-10, 2014, Pages 1009-1017

Capacitive sensing of microcystin variants of Microcystis aeruginosa using a gold immunoelectrode modified with antibodies, gold nanoparticles and polytyramine

Author keywords

Adda specific antibodies; Capacitive biosensor; M. aeruginosa; Microcystins; Real time analysis

Indexed keywords


EID: 84903125269     PISSN: 00263672     EISSN: 14365073     Source Type: Journal    
DOI: 10.1007/s00604-014-1199-4     Document Type: Article
Times cited : (29)

References (37)
  • 1
    • 27544443654 scopus 로고    scopus 로고
    • Cyanotoxins: new generation of water contaminants
    • Antoniou MG, de la Cruz AA, Dionysiou DD (2005) Cyanotoxins: new generation of water contaminants. J Environ Eng 13(9): 1239-1243.
    • (2005) J Environ Eng , vol.13 , Issue.9 , pp. 1239-1243
    • Antoniou, M.G.1    de la Cruz, A.A.2    Dionysiou, D.D.3
  • 2
    • 0026480619 scopus 로고
    • Isolation and structures of microcystins from a cyanobacterial water bloom (Finland)
    • Namikoshi M, Sivonen K, Evans WR, Sun F, Carmichael WW, Rinehart KL (1992) Isolation and structures of microcystins from a cyanobacterial water bloom (Finland). Toxicon 30(11): 1473-1479.
    • (1992) Toxicon , vol.30 , Issue.11 , pp. 1473-1479
    • Namikoshi, M.1    Sivonen, K.2    Evans, W.R.3    Sun, F.4    Carmichael, W.W.5    Rinehart, K.L.6
  • 4
    • 84934436178 scopus 로고    scopus 로고
    • Toxin mixture in cyanobacterial blooms-a critical comparison of reality with current procedures employed in human health risk assessment
    • In: Hudnell KH (Ed) Cyanobacterial Harmful Algal Blooms: State of the Science and Research Needs
    • Dietrich DR, Fischer A, Michel C, Hoeger SJ (2008) Toxin mixture in cyanobacterial blooms-a critical comparison of reality with current procedures employed in human health risk assessment. In: Hudnell KH (Ed) Cyanobacterial Harmful Algal Blooms: State of the Science and Research Needs. Adv Exp Med Biol 619: 885-912.
    • (2008) Adv Exp Med Biol , vol.619 , pp. 885-912
    • Dietrich, D.R.1    Fischer, A.2    Michel, C.3    Hoeger, S.J.4
  • 5
    • 0003771862 scopus 로고    scopus 로고
    • World Health Organization (WHO), 2nd edn. World Health Organization, Geneva
    • World Health Organization (WHO) (1998) Guidelines for drinking water quality, addendum to vol. 1, 2nd edn. World Health Organization, Geneva.
    • (1998) Guidelines for drinking water quality, addendum to vol. 1
  • 6
    • 78650295015 scopus 로고    scopus 로고
    • Determination of microcystins in river waters using microsensor arrays on disk
    • Morais S, Tamarit-Lopez J, Puchades R, Maquieira A (2010) Determination of microcystins in river waters using microsensor arrays on disk. Environ Sci Technol 44: 9024-9029.
    • (2010) Environ Sci Technol , vol.44 , pp. 9024-9029
    • Morais, S.1    Tamarit-Lopez, J.2    Puchades, R.3    Maquieira, A.4
  • 7
    • 62649097700 scopus 로고    scopus 로고
    • Portable optical immunosensor for highly sensitive detection of microcystin-LR in water samples
    • Long F, He M, Zhu AN, Shi HC (2009) Portable optical immunosensor for highly sensitive detection of microcystin-LR in water samples. Biosens Bioelectron 24: 2346-2351.
    • (2009) Biosens Bioelectron , vol.24 , pp. 2346-2351
    • Long, F.1    He, M.2    Zhu, A.N.3    Shi, H.C.4
  • 8
    • 84857356057 scopus 로고    scopus 로고
    • Automated portable array biosensor for multisample microcystin analysis in freshwater samples
    • Herranz S, Marazuela MD, Moreno-Bondi MC (2012) Automated portable array biosensor for multisample microcystin analysis in freshwater samples. Biosens Bioelectron 33: 50-55.
    • (2012) Biosens Bioelectron , vol.33 , pp. 50-55
    • Herranz, S.1    Marazuela, M.D.2    Moreno-Bondi, M.C.3
  • 9
    • 0035186921 scopus 로고    scopus 로고
    • Generic microcystin immunoassay based on monoclonal antibodies against Adda
    • Zeck A, Weller MG, Bursill D, Niessner R (2001) Generic microcystin immunoassay based on monoclonal antibodies against Adda. Analyst 126(11): 2002-2007.
    • (2001) Analyst , vol.126 , Issue.11 , pp. 2002-2007
    • Zeck, A.1    Weller, M.G.2    Bursill, D.3    Niessner, R.4
  • 10
    • 84861315228 scopus 로고    scopus 로고
    • Simultaneous quantification of microcystins and nodularin in aerosol samples using high-performance liquid chromatography/negative electrospray ionization tandem mass spectrometry
    • Gambaro A, Barbaro E, Zangrando R, Barbante C (2012) Simultaneous quantification of microcystins and nodularin in aerosol samples using high-performance liquid chromatography/negative electrospray ionization tandem mass spectrometry. Rapid Commun Mass Spectrom 26: 1497-1506.
    • (2012) Rapid Commun Mass Spectrom , vol.26 , pp. 1497-1506
    • Gambaro, A.1    Barbaro, E.2    Zangrando, R.3    Barbante, C.4
  • 12
    • 77958031676 scopus 로고    scopus 로고
    • Ultrasensitive detection of HIV-p24 antigen using nanofunctionalised surfaces in a capacitive immunosensor
    • Teeparuksapun K, Hedström M, Wong EY, Tang S, Hewlett IK, Mattiasson B (2010) Ultrasensitive detection of HIV-p24 antigen using nanofunctionalised surfaces in a capacitive immunosensor. Anal Chem 82(20): 8406-8411.
    • (2010) Anal Chem , vol.82 , Issue.20 , pp. 8406-8411
    • Teeparuksapun, K.1    Hedström, M.2    Wong, E.Y.3    Tang, S.4    Hewlett, I.K.5    Mattiasson, B.6
  • 13
    • 0018409915 scopus 로고
    • Generic assignments, strain histories and properties of pure cultures of cyanobacteria
    • Rippka R, Deruelles J, Waterbury JB, Herdman M, Stanier RY (1979) Generic assignments, strain histories and properties of pure cultures of cyanobacteria. J Gen Microbiol 111: 1-61.
    • (1979) J Gen Microbiol , vol.111 , pp. 1-61
    • Rippka, R.1    Deruelles, J.2    Waterbury, J.B.3    Herdman, M.4    Stanier, R.Y.5
  • 14
    • 4644219879 scopus 로고    scopus 로고
    • Review of the European Microcystis-morphospecies (Cyanoprokaryotes) from nature
    • Komárek J, Komárkova J (2002) Review of the European Microcystis-morphospecies (Cyanoprokaryotes) from nature. Czech Phycol Olomouc 2: 1-24.
    • (2002) Czech Phycol Olomouc , vol.2 , pp. 1-24
    • Komárek, J.1    Komárkova, J.2
  • 15
    • 36048974463 scopus 로고    scopus 로고
    • Optimization of laboratory scale production and purification of microcystin-LR from pure cultures of Microcystis aeruginosa
    • Phelan RR, Downing TG (2007) Optimization of laboratory scale production and purification of microcystin-LR from pure cultures of Microcystis aeruginosa. Afr J Biotechnol 6(21): 2451-2457.
    • (2007) Afr J Biotechnol , vol.6 , Issue.21 , pp. 2451-2457
    • Phelan, R.R.1    Downing, T.G.2
  • 16
    • 84855230342 scopus 로고    scopus 로고
    • Growth and toxin production of Microcystis aeruginosa PCC 7806 (Kutzing) Lemmerman at elevated salt concentrations
    • Black K, Yilmaz M, Phlips EJ (2011) Growth and toxin production of Microcystis aeruginosa PCC 7806 (Kutzing) Lemmerman at elevated salt concentrations. J Environ Prot 2: 669-674.
    • (2011) J Environ Prot , vol.2 , pp. 669-674
    • Black, K.1    Yilmaz, M.2    Phlips, E.J.3
  • 17
    • 58849105024 scopus 로고    scopus 로고
    • A capacitance immunosensor for detection of cholera toxin
    • Labib M, Hedström M, Amin M, Mattiasson B (2009) A capacitance immunosensor for detection of cholera toxin. Anal Chim Acta 634(2): 255-261.
    • (2009) Anal Chim Acta , vol.634 , Issue.2 , pp. 255-261
    • Labib, M.1    Hedström, M.2    Amin, M.3    Mattiasson, B.4
  • 19
    • 20444480914 scopus 로고    scopus 로고
    • Continuous measurements of a binding reaction using a capacitive biosensor
    • Hedström M, Galaev IY, Mattiasson B (2005) Continuous measurements of a binding reaction using a capacitive biosensor. Biosens Bioelectron 21: 41-48.
    • (2005) Biosens Bioelectron , vol.21 , pp. 41-48
    • Hedström, M.1    Galaev, I.Y.2    Mattiasson, B.3
  • 20
    • 71849101052 scopus 로고    scopus 로고
    • Immunochemical binding assays for detection and quantification of trace impurities in biotechnological production
    • Mattiasson B, Teeparuksapun K, Hedström M (2009) Immunochemical binding assays for detection and quantification of trace impurities in biotechnological production. Trends Biotechnol 28(1): 20-27.
    • (2009) Trends Biotechnol , vol.28 , Issue.1 , pp. 20-27
    • Mattiasson, B.1    Teeparuksapun, K.2    Hedström, M.3
  • 21
    • 14644403686 scopus 로고    scopus 로고
    • Guidance values for microcystins in water and cyanobacterial supplement products (blue-green algal supplements): a reasonable or misguided approach?
    • Dietrich DR, Hoeger SJ (2005) Guidance values for microcystins in water and cyanobacterial supplement products (blue-green algal supplements): a reasonable or misguided approach? Toxicol Appl Pharmacol 203: 273-289.
    • (2005) Toxicol Appl Pharmacol , vol.203 , pp. 273-289
    • Dietrich, D.R.1    Hoeger, S.J.2
  • 23
    • 19744374729 scopus 로고    scopus 로고
    • Ultrathin polytyramine films by electropolymerisation on highly doped p-type silicon electrodes
    • Losic D, Martin C, Thissen H, Voelcker NH (2005) Ultrathin polytyramine films by electropolymerisation on highly doped p-type silicon electrodes. Surf Sci 584: 245-257.
    • (2005) Surf Sci , vol.584 , pp. 245-257
    • Losic, D.1    Martin, C.2    Thissen, H.3    Voelcker, N.H.4
  • 24
    • 84864222437 scopus 로고    scopus 로고
    • Determination of microcystin-LR in waters in the subnanomolar range by sol-gel imprinted polymers on solid contact electrodes
    • Queirós RB, Noronha JP, Marques PVS, Fernandes JS, Sales MGF (2012) Determination of microcystin-LR in waters in the subnanomolar range by sol-gel imprinted polymers on solid contact electrodes. Analyst 137(10): 2437-2444.
    • (2012) Analyst , vol.137 , Issue.10 , pp. 2437-2444
    • Queirós, R.B.1    Noronha, J.P.2    Marques, P.V.S.3    Fernandes, J.S.4    Sales, M.G.F.5
  • 25
    • 84866287851 scopus 로고    scopus 로고
    • Photoelectrochemical immunoassay for microcystin-LR based on a fluoride-doped tin oxide glass electrode modified with a Cds-graphene composite
    • Tian J, Zhao H, Zhao H, Quan X (2012) Photoelectrochemical immunoassay for microcystin-LR based on a fluoride-doped tin oxide glass electrode modified with a Cds-graphene composite. Microchim Acta 179: 163-170.
    • (2012) Microchim Acta , vol.179 , pp. 163-170
    • Tian, J.1    Zhao, H.2    Zhao, H.3    Quan, X.4
  • 26
    • 84872048531 scopus 로고    scopus 로고
    • Determination of microcystin-LR with glassy carbon impedimetric immunoelectrode modified with an ionic liquid and multiwalled carbon nanotubes
    • Sun X, Guan L, Shi H, Ji J, Zhang Y, Li Z (2013) Determination of microcystin-LR with glassy carbon impedimetric immunoelectrode modified with an ionic liquid and multiwalled carbon nanotubes. Microchim Acta 180: 75-83.
    • (2013) Microchim Acta , vol.180 , pp. 75-83
    • Sun, X.1    Guan, L.2    Shi, H.3    Ji, J.4    Zhang, Y.5    Li, Z.6
  • 27
    • 79955900944 scopus 로고    scopus 로고
    • Label-free immunosensing of microcystin-LR using gold electrode modified with gold nanoparticles
    • Tong P, Tang S, He Y, Shao Y, Zhang L, Chen G (2011) Label-free immunosensing of microcystin-LR using gold electrode modified with gold nanoparticles. Microchim Acta 173: 299-305.
    • (2011) Microchim Acta , vol.173 , pp. 299-305
    • Tong, P.1    Tang, S.2    He, Y.3    Shao, Y.4    Zhang, L.5    Chen, G.6
  • 28
    • 33745463664 scopus 로고    scopus 로고
    • Evaluation of methods for the isolation, detection and quantification of cyanobacterial hepatotoxins
    • Msagati TAM, Siame BA, Shushu DD (2006) Evaluation of methods for the isolation, detection and quantification of cyanobacterial hepatotoxins. Aquat Toxicol 78: 382-397.
    • (2006) Aquat Toxicol , vol.78 , pp. 382-397
    • Msagati, T.A.M.1    Siame, B.A.2    Shushu, D.D.3
  • 29
    • 77952882593 scopus 로고    scopus 로고
    • Flow based immune/bioassays and trends in micro-immuno/biosensors
    • Hartwell SK, Grudpan K (2010) Flow based immune/bioassays and trends in micro-immuno/biosensors. Microchim Acta 169: 201-220.
    • (2010) Microchim Acta , vol.169 , pp. 201-220
    • Hartwell, S.K.1    Grudpan, K.2
  • 30
    • 0035407727 scopus 로고    scopus 로고
    • Comparison of liquid chromatography/mass spectrometry, ELISA, and phosphatase assay for the determination of microcystins in blue-green algae products
    • Lawrence JF, Niedzwiadek B, Menard C, Lau BP, Lewis D, Kuper-Goodman T, Carbone S, Holmes C (2001) Comparison of liquid chromatography/mass spectrometry, ELISA, and phosphatase assay for the determination of microcystins in blue-green algae products. J AOAC Int 84(4): 1035-1044.
    • (2001) J AOAC Int , vol.84 , Issue.4 , pp. 1035-1044
    • Lawrence, J.F.1    Niedzwiadek, B.2    Menard, C.3    Lau, B.P.4    Lewis, D.5    Kuper-Goodman, T.6    Carbone, S.7    Holmes, C.8
  • 31
    • 34249077676 scopus 로고    scopus 로고
    • An ultra-performance liquid chromatography-tandem mass spectrometry method for determination of microcystins occurrence in surface water in Zhejiang Province, China
    • Wang J, Pang X, Ge F, Ma Z (2007) An ultra-performance liquid chromatography-tandem mass spectrometry method for determination of microcystins occurrence in surface water in Zhejiang Province, China. Toxicon 49: 1120-1128.
    • (2007) Toxicon , vol.49 , pp. 1120-1128
    • Wang, J.1    Pang, X.2    Ge, F.3    Ma, Z.4
  • 33
    • 34248197143 scopus 로고    scopus 로고
    • Liquid chromatography-Tandem mass spectrometry application, for the determination of extracellular hepatotoxins in Irish lake and drinking waters
    • Allis O, Dauphard J, Hamilton B, Shuilleabhain AN, Lehane M, James KJ, Furey A (2007) Liquid chromatography-Tandem mass spectrometry application, for the determination of extracellular hepatotoxins in Irish lake and drinking waters. Anal Chem 79: 3436-3447.
    • (2007) Anal Chem , vol.79 , pp. 3436-3447
    • Allis, O.1    Dauphard, J.2    Hamilton, B.3    Shuilleabhain, A.N.4    Lehane, M.5    James, K.J.6    Furey, A.7
  • 34
    • 77649233502 scopus 로고    scopus 로고
    • Detection of various freshwater cyanobacterial toxins using ultra-performance liquid chromatography tandem mass spectrometry
    • Oehrle SA, Southwell B, Westrick J (2010) Detection of various freshwater cyanobacterial toxins using ultra-performance liquid chromatography tandem mass spectrometry. Toxicon 55: 965-972.
    • (2010) Toxicon , vol.55 , pp. 965-972
    • Oehrle, S.A.1    Southwell, B.2    Westrick, J.3
  • 35
    • 0006724508 scopus 로고    scopus 로고
    • Effect of amino acid side-chain on fragmentation of cyclic peptide ions: differences of electrospray ionization/collision-induced decomposition mass spectra of toxic heptapeptide micorcystin containing ADMAdda instead of Adda
    • Yuan M, Namikoshi M, Otsuki A, Sivonen K (1998) Effect of amino acid side-chain on fragmentation of cyclic peptide ions: differences of electrospray ionization/collision-induced decomposition mass spectra of toxic heptapeptide micorcystin containing ADMAdda instead of Adda. Eur J Mass Spectrom 4: 287-298.
    • (1998) Eur J Mass Spectrom , vol.4 , pp. 287-298
    • Yuan, M.1    Namikoshi, M.2    Otsuki, A.3    Sivonen, K.4
  • 36
    • 84871752751 scopus 로고    scopus 로고
    • Magnetic particle-based enzyme assays and immunoassays for microcystins: from colorimetric to electrochemical detection
    • Reverté L, Garibo D, Flores C, Diogène J, Caixach J, Campàs M (2013) Magnetic particle-based enzyme assays and immunoassays for microcystins: from colorimetric to electrochemical detection. Environ Sci Technol 47: 471-478.
    • (2013) Environ Sci Technol , vol.47 , pp. 471-478
    • Reverté, L.1    Garibo, D.2    Flores, C.3    Diogène, J.4    Caixach, J.5    Campàs, M.6
  • 37
    • 34548657128 scopus 로고    scopus 로고
    • Rapid detection of cyanobacterial toxins in precursor ion mode by liquid chromatography tandem mass spectrometry
    • Hiller S, Krock B, Cembella A, Luckas B (2007) Rapid detection of cyanobacterial toxins in precursor ion mode by liquid chromatography tandem mass spectrometry. J Mass Spectrom 42: 1238-1250.
    • (2007) J Mass Spectrom , vol.42 , pp. 1238-1250
    • Hiller, S.1    Krock, B.2    Cembella, A.3    Luckas, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.