메뉴 건너뛰기




Volumn 96 B, Issue 6, 2014, Pages 765-771

Autologous wound drains have no effect on allogeneic blood transfusions in primary total hip and knee replacement: A three-arm randomised trial

Author keywords

[No Author keywords available]

Indexed keywords

CEPHALOSPORIN; HEMOGLOBIN; LOW MOLECULAR WEIGHT HEPARIN; RECOMBINANT ERYTHROPOIETIN;

EID: 84902593571     PISSN: 20494394     EISSN: 20494408     Source Type: Journal    
DOI: 10.1302/0301-620X.96B6.33021     Document Type: Article
Times cited : (22)

References (22)
  • 2
    • 79960949355 scopus 로고    scopus 로고
    • Nonanemic patients do not benefit from autologous blood donation before total knee replacement
    • Kim S, Altneu E, Monsef JB, et al. Nonanemic patients do not benefit from autologous blood donation before total knee replacement. HSS J 2011;7:141-144.
    • (2011) HSS J , vol.7 , pp. 141-144
    • Kim, S.1    Altneu, E.2    Monsef, J.B.3
  • 3
    • 77955174943 scopus 로고    scopus 로고
    • Anemia and patient blood management in hip and knee surgery: A systematic review of the literature
    • Spahn DR. Anemia and patient blood management in hip and knee surgery: a systematic review of the literature. Anesthesiology 2010;113:482-495.
    • (2010) Anesthesiology , vol.113 , pp. 482-495
    • Spahn, D.R.1
  • 5
    • 73649132288 scopus 로고    scopus 로고
    • A randomized comparison of transfusion triggers in elective orthopaedic surgery using leucocyte-depleted red blood cells
    • So-Osman C, Nelissen R, Te Slaa R, et al. A randomized comparison of transfusion triggers in elective orthopaedic surgery using leucocyte-depleted red blood cells. Vox Sang 2010;98:56-64.
    • (2010) Vox Sang , vol.98 , pp. 56-64
    • So-Osman, C.1    Nelissen, R.2    Te Slaa, R.3
  • 6
    • 84866422717 scopus 로고    scopus 로고
    • Limit allogeneic blood use with routine re-use of patient's own blood: A prospective, randomized, controlled trial in total hip surgery
    • Thomassen BJ, Pilot P, Scholtes VA, et al. Limit allogeneic blood use with routine re-use of patient's own blood: a prospective, randomized, controlled trial in total hip surgery. PLoS One 2012;7:44503.
    • (2012) PLoS One , vol.7 , pp. 44503
    • Thomassen, B.J.1    Pilot, P.2    Scholtes, V.A.3
  • 7
    • 84864042696 scopus 로고    scopus 로고
    • Transfusion thresholds and other strategies for guiding allogeneic red blood cell transfusion
    • Carson JL, Carless PA, Hebert PC. Transfusion thresholds and other strategies for guiding allogeneic red blood cell transfusion. Cochrane Database Syst Rev 2012;4:CD002042.
    • (2012) Cochrane Database Syst Rev , vol.4
    • Carson, J.L.1    Carless, P.A.2    Hebert, P.C.3
  • 9
    • 42149140650 scopus 로고    scopus 로고
    • A prospective randomised controlled trial of autologous retransfusion in total knee replacement
    • Amin A, Watson A, Mangwani J, et al. A prospective randomised controlled trial of autologous retransfusion in total knee replacement. J Bone Joint Surg [Br] 2008;90-B:451-454.
    • (2008) J Bone Joint Surg [Br] , vol.90 B , pp. 451-454
    • Amin, A.1    Watson, A.2    Mangwani, J.3
  • 12
    • 33644804218 scopus 로고    scopus 로고
    • Investigation of the use of drained blood reinfusion after total knee arthroplasty: A prospective randomised controlled study
    • Cheng SC, Hung TS, Tse PY. Investigation of the use of drained blood reinfusion after total knee arthroplasty: a prospective randomised controlled study. J Orthop Surg (Hong Kong) 2005;13:120-124.
    • (2005) J Orthop Surg (Hong Kong) , vol.13 , pp. 120-124
    • Cheng, S.C.1    Hung, T.S.2    Tse, P.Y.3
  • 13
    • 49549098132 scopus 로고    scopus 로고
    • Autologous drains in arthroplasty a randomized control trial
    • Wood GC, Kapoor A, Javed A. Autologous drains in arthroplasty a randomized control trial. J Arthroplasty 2008;23:808-813.
    • (2008) J Arthroplasty , vol.23 , pp. 808-813
    • Wood, G.C.1    Kapoor, A.2    Javed, A.3
  • 15
    • 85020157500 scopus 로고    scopus 로고
    • No authors listed. nvic.nl/sites/default/files/ CBO%20Richtlijn%20Bloedtransfusie.pdf (date last accessed 23 April 2014) [article in Dutch]
    • No authors listed. Dutch guidelines blood transfusion. nvic.nl/sites/default/files/ CBO%20Richtlijn%20Bloedtransfusie.pdf page 191. (date last accessed 23 April 2014) [article in Dutch].
    • Dutch Guidelines Blood Transfusion , pp. 191
  • 16
    • 33847025968 scopus 로고    scopus 로고
    • Retransfusion of filtered shed blood in primary total hip and knee arthroplasty: A prospective randomized clinical trial
    • Moonen AF, Knoors NT, van Os JJ, Verburg AD, Pilot P. Retransfusion of filtered shed blood in primary total hip and knee arthroplasty: a prospective randomized clinical trial. Transfusion 2007;47:379-384.
    • (2007) Transfusion , vol.47 , pp. 379-384
    • Moonen, A.F.1    Knoors, N.T.2    Van Os, J.J.3    Verburg, A.D.4    Pilot, P.5
  • 18
    • 0018183102 scopus 로고
    • ASA physical status classifications: A study of consistency of ratings
    • Owens WD, Felts JA, Spitznagel EL Jr. ASA physical status classifications: a study of consistency of ratings. Anesthesiology. 1978;49:239-243. (Pubitemid 9032534)
    • (1978) Anesthesiology , vol.49 , Issue.4 , pp. 239-243
    • Owens, W.D.1    Felts, J.A.2    Spitznagel Jr., E.L.3
  • 19
    • 27244446039 scopus 로고    scopus 로고
    • A prospective, randomised, controlled trial of the use of drains in total hip arthroplasty
    • DOI 10.1302/0301-620X.87B10.16221
    • Walmsley PJ, Kelly MB, Hill RM, Brenkel I. A prospective, randomised, controlled trial of the use of drains in total hip arthroplasty. J Bone Joint Surg [Br] 2005;87-B:1397-1401. (Pubitemid 41511806)
    • (2005) Journal of Bone and Joint Surgery - Series B , vol.87 , Issue.10 , pp. 1397-1401
    • Walmsley, P.J.1    Kelly, M.B.2    Hill, R.M.F.3    Brenkel, I.4
  • 20
    • 84857629001 scopus 로고    scopus 로고
    • Closed suction drainage with or without re-transfusion of filtered shed blood does not offer advantages in primary non-cemented total hip replacement using a direct anterior approach
    • Kleinert K, Werner C, Mamisch-Saupe N, Kalberer F, Dora C. Closed suction drainage with or without re-transfusion of filtered shed blood does not offer advantages in primary non-cemented total hip replacement using a direct anterior approach. Arch Orthop Trauma Surg 2012;132:131-136.
    • (2012) Arch Orthop Trauma Surg , vol.132 , pp. 131-136
    • Kleinert, K.1    Werner, C.2    Mamisch-Saupe, N.3    Kalberer, F.4    Dora, C.5
  • 21
    • 79955963699 scopus 로고    scopus 로고
    • No clear advantage to use of wound drains after unilateral total knee arthroplasty: A prospective randomized, controlled trial
    • Li C, Nijat A, Askar M. No clear advantage to use of wound drains after unilateral total knee arthroplasty: a prospective randomized, controlled trial. J Arthroplasty 2011;26:519-522.
    • (2011) J Arthroplasty , vol.26 , pp. 519-522
    • Li, C.1    Nijat, A.2    Askar, M.3
  • 22
    • 0036483174 scopus 로고    scopus 로고
    • Preoperative hemoglobin levels and the need for transfusion after prosthetic hip and knee surgery: Analysis of predictive factors
    • Salido JA, Marín LA, Gómez LA, Zorrilla P, Martínez C. Preoperative hemoglobin levels and the need for transfusion after prosthetic hip and knee surgery: analysis of predictive factors. J Bone Joint Surg [Am] 2002;84-A:216-220.
    • (2002) J Bone Joint Surg [Am] , vol.84 A , pp. 216-220