메뉴 건너뛰기




Volumn 39, Issue 20, 2014, Pages 10613-10626

Diagnostic tools for PEMFCs: From conception to implementation

Author keywords

Comparison; Drying; Fault diagnosis; Flooding; PEM fuel cell; Performances

Indexed keywords

DEGRADATION; DIAGNOSTIC PRODUCTS; DRYING; FAILURE ANALYSIS; FLOODS; OIL WELL FLOODING;

EID: 84902545373     PISSN: 03603199     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijhydene.2014.04.163     Document Type: Article
Times cited : (49)

References (61)
  • 1
    • 0035799631 scopus 로고    scopus 로고
    • Electrochemical impedance study of PEM fuel cells. Experimental diagnostics and modeling of air cathodes
    • M. Ciureanu, and R. Roberge Electrochemical impedance study of PEM fuel cells. Experimental diagnostics and modeling of air cathodes J Phys Chem B 105 2001 3531 3539
    • (2001) J Phys Chem B , vol.105 , pp. 3531-3539
    • Ciureanu, M.1    Roberge, R.2
  • 2
    • 33748077454 scopus 로고    scopus 로고
    • Model based PEM fuel cell state-of-health monitoring via ac impedance measurements
    • Fouquet, C. Doulet, C. Nouillan, G. Dauphin-Tanguy, and B. Ould-Bouamama Model based PEM fuel cell state-of-health monitoring via ac impedance measurements J Power Sourc 159 2006 905 913
    • (2006) J Power Sourc , vol.159 , pp. 905-913
    • Fouquet1    Doulet, C.2    Nouillan, C.3    Dauphin-Tanguy, G.4    Ould-Bouamama, B.5
  • 5
    • 64549143747 scopus 로고    scopus 로고
    • Nonlinear frequency response analysis of PEM fuel cells for diagnosis of dehydration, flooding and CO-poisoning
    • T. Kadyk, R. Hanke-Rauschenbach, and K. Sundmacher Nonlinear frequency response analysis of PEM fuel cells for diagnosis of dehydration, flooding and CO-poisoning J Electroanal Chem 630 2009 19 27
    • (2009) J Electroanal Chem , vol.630 , pp. 19-27
    • Kadyk, T.1    Hanke-Rauschenbach, R.2    Sundmacher, K.3
  • 6
    • 84856697110 scopus 로고    scopus 로고
    • State-of-health diagnosis based on hamming neural network using output voltage pattern recognition for a PEM fuel cell
    • J. Kim, I. Lee, Y. Tak, and B.H. Cho State-of-health diagnosis based on hamming neural network using output voltage pattern recognition for a PEM fuel cell Int J Hydrogen Energy 37 2012 4280 4289
    • (2012) Int J Hydrogen Energy , vol.37 , pp. 4280-4289
    • Kim, J.1    Lee, I.2    Tak, Y.3    Cho, B.H.4
  • 7
    • 33645677018 scopus 로고    scopus 로고
    • Detection of membrane drying, fuel cell flooding, and anode catalyst poisoning on PEMFC stacks by electrochemical impedance spectroscopy
    • J.M. Le Canut, R.M. Abouatallah, and D.A. Harrington Detection of membrane drying, fuel cell flooding, and anode catalyst poisoning on PEMFC stacks by electrochemical impedance spectroscopy J Electrochem Soc 153 5 2006 A857 A864
    • (2006) J Electrochem Soc , vol.153 , Issue.5
    • Le Canut, J.M.1    Abouatallah, R.M.2    Harrington, D.A.3
  • 8
    • 33748974959 scopus 로고    scopus 로고
    • Characterization of proton exchange membrane fuel cell (PEMFC) failures via electrochemical impedance spectroscopy
    • W. Mérida, D.A. Harrington, J.M. Le Canut, and G. McLean Characterization of proton exchange membrane fuel cell (PEMFC) failures via electrochemical impedance spectroscopy J Power Sourc 161 2006 264 274
    • (2006) J Power Sourc , vol.161 , pp. 264-274
    • Mérida, W.1    Harrington, D.A.2    Le Canut, J.M.3    McLean, G.4
  • 9
    • 84859311001 scopus 로고    scopus 로고
    • Diagnosing degradation within PEM fuel cell catalyst layers using electrochemical impedance spectroscopy
    • F.S. Saleh, and E.B. Easton Diagnosing degradation within PEM fuel cell catalyst layers using electrochemical impedance spectroscopy J Electrochem Soc 159 5 2012 B546 B553
    • (2012) J Electrochem Soc , vol.159 , Issue.5
    • Saleh, F.S.1    Easton, E.B.2
  • 10
    • 1542364455 scopus 로고    scopus 로고
    • Change of electrochemical impedance spectra (EIS) with time during CO-poisoning of the Pt-anode in a membrane fuel cell
    • N. Wagner, and E. Gtilzow Change of electrochemical impedance spectra (EIS) with time during CO-poisoning of the Pt-anode in a membrane fuel cell J Power Sourc 127 2004 341 347
    • (2004) J Power Sourc , vol.127 , pp. 341-347
    • Wagner, N.1    Gtilzow, E.2
  • 11
    • 33750946385 scopus 로고    scopus 로고
    • AC impedance diagnosis of a 500 W PEM fuel ceil stack part I: Stack impedance
    • X. Yuan, J.C. Sun, M. Blanco, H. Wang, J. Zhang, and D.P. Wilkinson AC impedance diagnosis of a 500 W PEM fuel ceil stack part I: stack impedance J Power Sourc 161 2006 920 928
    • (2006) J Power Sourc , vol.161 , pp. 920-928
    • Yuan, X.1    Sun, J.C.2    Blanco, M.3    Wang, H.4    Zhang, J.5    Wilkinson, D.P.6
  • 12
    • 33750941554 scopus 로고    scopus 로고
    • AC impedance diagnosis of a 500 W PEM fuel cell stack part II: Individual cell impedance
    • X. Yuan, J.C. Sun, M. Blanco, H. Wang, J. Zhang, and D.P. Wilkinson AC impedance diagnosis of a 500 W PEM fuel cell stack part II: individual cell impedance J Power Sourc 161 2006 929 937
    • (2006) J Power Sourc , vol.161 , pp. 929-937
    • Yuan, X.1    Sun, J.C.2    Blanco, M.3    Wang, H.4    Zhang, J.5    Wilkinson, D.P.6
  • 13
    • 79959738684 scopus 로고    scopus 로고
    • Fault detection and isolation of PEM fuel cell system based on nonlinear analytical redundancy
    • Aitouche, Q. Yang, and B.O. Bouamama Fault detection and isolation of PEM fuel cell system based on nonlinear analytical redundancy Eur Phys J Appl Phys 54 2 2012 23408 23419
    • (2012) Eur Phys J Appl Phys , vol.54 , Issue.2 , pp. 23408-23419
    • Aitouche1    Yang, Q.2    Bouamama, B.O.3
  • 14
    • 12344295481 scopus 로고    scopus 로고
    • Relationship between pressure drop and cell resistance as a diagnostic tool for PEM fuel cells
    • F. Barbir, H. Gorgun, and X. Wang Relationship between pressure drop and cell resistance as a diagnostic tool for PEM fuel cells J Power Sourc 141 2005 96 101
    • (2005) J Power Sourc , vol.141 , pp. 96-101
    • Barbir, F.1    Gorgun, H.2    Wang, X.3
  • 17
    • 77950690387 scopus 로고    scopus 로고
    • Modeling and fault diagnosis of a polymer electrolyte fuel cell using electrical equivalent analysis
    • A. Hernandez, D. Hissel, and R. Outbib Modeling and fault diagnosis of a polymer electrolyte fuel cell using electrical equivalent analysis IEEE Trans Energy Convers 25 2010 148 160
    • (2010) IEEE Trans Energy Convers , vol.25 , pp. 148-160
    • Hernandez, A.1    Hissel, D.2    Outbib, R.3
  • 18
    • 1542273215 scopus 로고    scopus 로고
    • Diagnosis of automotive fuel cell power generators
    • D. Hissel, M.C. Péra, and J.M. Kauffmann Diagnosis of automotive fuel cell power generators J Power Sourc 128 2004 239 246
    • (2004) J Power Sourc , vol.128 , pp. 239-246
    • Hissel, D.1    Péra, M.C.2    Kauffmann, J.M.3
  • 19
    • 78650717339 scopus 로고    scopus 로고
    • Analysis of a fuel cell system by a step response
    • M. Jung, M.D. Ashford, and K.A. Williams Analysis of a fuel cell system by a step response Fuel Cell 11 2 2011 327 338
    • (2011) Fuel Cell , vol.11 , Issue.2 , pp. 327-338
    • Jung, M.1    Ashford, M.D.2    Williams, K.A.3
  • 20
    • 72149128443 scopus 로고    scopus 로고
    • Pressure-voltage oscillations as a diagnostic tool for PEFC cathodes
    • A.M. Niroumand, W. Mérida, M. Eikerling, and M. Saif Pressure-voltage oscillations as a diagnostic tool for PEFC cathodes Electrochem Commun 12 2010 122 124
    • (2010) Electrochem Commun , vol.12 , pp. 122-124
    • Niroumand, A.M.1    Mérida, W.2    Eikerling, M.3    Saif, M.4
  • 22
    • 36348986170 scopus 로고    scopus 로고
    • On-line fault diagnostic system for proton exchange membrane fuel cells
    • L.A.M. Riascos, M.G. Simoes, and P.E. Miyagi On-line fault diagnostic system for proton exchange membrane fuel cells J Power Sourc 175 2008 419 429
    • (2008) J Power Sourc , vol.175 , pp. 419-429
    • Riascos, L.A.M.1    Simoes, M.G.2    Miyagi, P.E.3
  • 23
    • 34548393528 scopus 로고    scopus 로고
    • Diagnosis of PEM fuel cells through current interruption
    • M.A. Rubio, A. Urquia, and S. Dormido Diagnosis of PEM fuel cells through current interruption J Power Sourc 171 2007 670 677
    • (2007) J Power Sourc , vol.171 , pp. 670-677
    • Rubio, M.A.1    Urquia, A.2    Dormido, S.3
  • 24
    • 77951023309 scopus 로고    scopus 로고
    • Diagnosis of performance degradation phenomena in PEM fuel cells
    • M.A. Rubio, A. Urquia, and S. Dormido Diagnosis of performance degradation phenomena in PEM fuel cells Int J Hydrogen Energy 35 2010 2586 2590
    • (2010) Int J Hydrogen Energy , vol.35 , pp. 2586-2590
    • Rubio, M.A.1    Urquia, A.2    Dormido, S.3
  • 25
    • 17644413559 scopus 로고    scopus 로고
    • Diagnostic tools for liquid water in PEM fuel cells
    • J. Stumper, M. Löhr, and S. Hamada Diagnostic tools for liquid water in PEM fuel cells J Power Sourc 143 2005 150 157
    • (2005) J Power Sourc , vol.143 , pp. 150-157
    • Stumper, J.1    Löhr, M.2    Hamada, S.3
  • 26
    • 33749992572 scopus 로고    scopus 로고
    • Model-based condition monitoring of PEM fuel cell using Hotelling 12 control limit
    • X. Xuea, J. Tanga, N. Sammesa, and Y. Ding Model-based condition monitoring of PEM fuel cell using Hotelling 12 control limit J Power Sourc 162 2006 388 399
    • (2006) J Power Sourc , vol.162 , pp. 388-399
    • Xuea, X.1    Tanga, J.2    Sammesa, N.3    Ding, Y.4
  • 27
    • 79951578942 scopus 로고    scopus 로고
    • Diagnosis of polymer electrolyte fuel cells failure modes (flooding & drying out) by neural networks modeling
    • N. Yousfi Steiner, D. Hissel, P. Moçotéguy, and D. Candusso Diagnosis of polymer electrolyte fuel cells failure modes (flooding & drying out) by neural networks modeling Int J Hydrogen Energy 36 2011 3067 3075
    • (2011) Int J Hydrogen Energy , vol.36 , pp. 3067-3075
    • Yousfi Steiner, N.1    Hissel, D.2    Moçotéguy, P.3    Candusso, D.4
  • 29
    • 38049066023 scopus 로고    scopus 로고
    • Diagnosis of PEM fuel cell stack dynamic behaviors
    • J. Chen, and B. Zhou Diagnosis of PEM fuel cell stack dynamic behaviors J Power Sourc 177 2008 83 95
    • (2008) J Power Sourc , vol.177 , pp. 83-95
    • Chen, J.1    Zhou, B.2
  • 31
    • 84861194589 scopus 로고    scopus 로고
    • First results on PEMFC diagnosis by electrochemical noise
    • B. Legros, P.X. Thivel, and R.P. Nogueira First results on PEMFC diagnosis by electrochemical noise Electrochem Commun 13 12 2011 1514 1516
    • (2011) Electrochem Commun , vol.13 , Issue.12 , pp. 1514-1516
    • Legros, B.1    Thivel, P.X.2    Nogueira, R.P.3
  • 32
    • 79251649501 scopus 로고    scopus 로고
    • Non-intrusive diagnosis of polymer electrolyte fuel cells by wavelet packet transform
    • N. Yousfi Steiner, D. Hissel, P. Moçotéguy, and D. Candusso Non-intrusive diagnosis of polymer electrolyte fuel cells by wavelet packet transform Int J Hydrogen Energy 36 2011 740 746
    • (2011) Int J Hydrogen Energy , vol.36 , pp. 740-746
    • Yousfi Steiner, N.1    Hissel, D.2    Moçotéguy, P.3    Candusso, D.4
  • 33
    • 46749085816 scopus 로고    scopus 로고
    • A review on PEM voltage degradation associated with water management: Impact, influent factors and characterization
    • N. Youfi-Steiner, Ph. Moçotéguy, D. Candusso, D. Hissel, A. Hernandez, and A. Aslanides A review on PEM voltage degradation associated with water management: impact, influent factors and characterization J Power Sourc 183 2008 260 274
    • (2008) J Power Sourc , vol.183 , pp. 260-274
    • Youfi-Steiner, N.1    Moçotéguy, Ph.2    Candusso, D.3    Hissel, D.4    Hernandez, A.5    Aslanides, A.6
  • 36
    • 79960900004 scopus 로고    scopus 로고
    • Proton exchange membrane fuel cell system diagnosis based on the multivariate statistical method
    • J. Hua, J. Li, M. Ouyang, L. Lu, and L. Xu Proton exchange membrane fuel cell system diagnosis based on the multivariate statistical method Int J Hydrogen Energy 36 16 2011 9896 9905
    • (2011) Int J Hydrogen Energy , vol.36 , Issue.16 , pp. 9896-9905
    • Hua, J.1    Li, J.2    Ouyang, M.3    Lu, L.4    Xu, L.5
  • 37
    • 77951295497 scopus 로고    scopus 로고
    • Analysis of PEM fuel cell experimental data using principal component analysis and multi linear regression
    • L. Placca, R. Kouta, D. Candusso, J.-F. Blachot, and W. Charon Analysis of PEM fuel cell experimental data using principal component analysis and multi linear regression Int J Hydrogen Energy 35 10 2010 4582 4591
    • (2010) Int J Hydrogen Energy , vol.35 , Issue.10 , pp. 4582-4591
    • Placca, L.1    Kouta, R.2    Candusso, D.3    Blachot, J.-F.4    Charon, W.5
  • 39
    • 79951849537 scopus 로고    scopus 로고
    • LPV observer design for PEM fuel cell system: Application to fault detection
    • S. De Lira, V. Puig, J. Quevedo, and A. Husar LPV observer design for PEM fuel cell system: application to fault detection J Power Sourc 196 2011 4298 4305
    • (2011) J Power Sourc , vol.196 , pp. 4298-4305
    • De Lira, S.1    Puig, V.2    Quevedo, J.3    Husar, A.4
  • 40
    • 84875364524 scopus 로고    scopus 로고
    • An analysis of fluidic voltage statistical correlation for a diagnosis of PEM fuel cell flooding
    • S. Giurgea, R. Tirnovan, D. Hissel, and R. Outbib An analysis of fluidic voltage statistical correlation for a diagnosis of PEM fuel cell flooding Int J Hydrogen Energy 38 2013 4689 4696
    • (2013) Int J Hydrogen Energy , vol.38 , pp. 4689-4696
    • Giurgea, S.1    Tirnovan, R.2    Hissel, D.3    Outbib, R.4
  • 42
    • 33748954405 scopus 로고    scopus 로고
    • Electrical test methods for on-line fuel cell ohmic resistance measurement
    • K.R. Cooper, and M. Smith Electrical test methods for on-line fuel cell ohmic resistance measurement J Power Sourc 160 2006 1088 1095
    • (2006) J Power Sourc , vol.160 , pp. 1088-1095
    • Cooper, K.R.1    Smith, M.2
  • 43
    • 77249111076 scopus 로고    scopus 로고
    • Fuzzy-clustering durability diagnosis of polymer electrolyte fuel cells dedicated to transportation applications
    • D. Hissel, D. Candusso, and F. Harel Fuzzy-clustering durability diagnosis of polymer electrolyte fuel cells dedicated to transportation applications IEEE Trans Veh Technol 56 5 2007 2414 2420
    • (2007) IEEE Trans Veh Technol , vol.56 , Issue.5 , pp. 2414-2420
    • Hissel, D.1    Candusso, D.2    Harel, F.3
  • 44
    • 77955510262 scopus 로고    scopus 로고
    • The estimation of fuel cell operating time for predictive maintenance strategies
    • R. Onanena, L. Oukhellou, D. Candusso, A. Same, D. Hissel, and P. Aknin The estimation of fuel cell operating time for predictive maintenance strategies Int J Hydrogen Energy 35 15 2010 8022 8029
    • (2010) Int J Hydrogen Energy , vol.35 , Issue.15 , pp. 8022-8029
    • Onanena, R.1    Oukhellou, L.2    Candusso, D.3    Same, A.4    Hissel, D.5    Aknin, P.6
  • 45
    • 79551471671 scopus 로고    scopus 로고
    • Fuel cells static and dynamic characterizations as tools for the estimation of their ageing time
    • R. Onanena, L. Oukhellou, D. Candusso, F. Harel, D. Hissel, and P. Aknin Fuel cells static and dynamic characterizations as tools for the estimation of their ageing time Int J Hydrogen Energy 36 2011 1730 1739
    • (2011) Int J Hydrogen Energy , vol.36 , pp. 1730-1739
    • Onanena, R.1    Oukhellou, L.2    Candusso, D.3    Harel, F.4    Hissel, D.5    Aknin, P.6
  • 47
    • 68049131098 scopus 로고    scopus 로고
    • Limit operating temperature in PEM fuel cells
    • M.A. Riascos, and D.D. Pereira Limit operating temperature in PEM fuel cells J Electrochem Soc 156 9 2009 B1051 B1058
    • (2009) J Electrochem Soc , vol.156 , Issue.9
    • Riascos, M.A.1    Pereira, D.D.2
  • 49
    • 73549116750 scopus 로고    scopus 로고
    • A review of water management in polymer electrolyte membrane fuel cells
    • M. Ji, and Z. Wei A review of water management in polymer electrolyte membrane fuel cells Energies 2 2009 1057 1106
    • (2009) Energies , vol.2 , pp. 1057-1106
    • Ji, M.1    Wei, Z.2
  • 50
    • 58149173958 scopus 로고    scopus 로고
    • Visualisation of water accumulation in the flow channels of PEMFC under various operating conditions
    • T. Ous, and C. Arcoumanis Visualisation of water accumulation in the flow channels of PEMFC under various operating conditions J Power Sourc 187 2009 182 189
    • (2009) J Power Sourc , vol.187 , pp. 182-189
    • Ous, T.1    Arcoumanis, C.2
  • 52
    • 80052807143 scopus 로고    scopus 로고
    • Fault tree analysis for PEM fuel cell degradation process modelling
    • L. Placca, and R. Kouta Fault tree analysis for PEM fuel cell degradation process modelling Int J Hydrogen Energy 36 2011 12393 12405
    • (2011) Int J Hydrogen Energy , vol.36 , pp. 12393-12405
    • Placca, L.1    Kouta, R.2
  • 57
    • 33750506476 scopus 로고    scopus 로고
    • Model-based evaluation of clustering validation measures
    • M. Brun, C. Sima, J. Hua, J. Lowey, B. Carroll, and E. Suh et al. Model-based evaluation of clustering validation measures Pattern Recogn 40 2007 807 824
    • (2007) Pattern Recogn , vol.40 , pp. 807-824
    • Brun, M.1    Sima, C.2    Hua, J.3    Lowey, J.4    Carroll, B.5    Suh, E.6
  • 58
    • 35948929058 scopus 로고    scopus 로고
    • Simultaneous fault diagnosis in chemical plants using a MultiLabel approach
    • I. Yélamos, M. Graells, L. Puigjaner, and G. Escudero Simultaneous fault diagnosis in chemical plants using a MultiLabel approach AIChE J 53 11 2007 2871 2884
    • (2007) AIChE J , vol.53 , Issue.11 , pp. 2871-2884
    • Yélamos, I.1    Graells, M.2    Puigjaner, L.3    Escudero, G.4
  • 59
    • 56949099324 scopus 로고    scopus 로고
    • Performance assessment of a novel fault diagnosis system based on support vector machines
    • I. Yélamos, G. Escudero, M. Graells, and L. Puigjaner Performance assessment of a novel fault diagnosis system based on support vector machines Comput Chem Eng 33 2009 244 255
    • (2009) Comput Chem Eng , vol.33 , pp. 244-255
    • Yélamos, I.1    Escudero, G.2    Graells, M.3    Puigjaner, L.4
  • 61
    • 78650032061 scopus 로고    scopus 로고
    • A new high voltage impedance spectrometer for the diagnostic of the fuel cell stacks
    • 6
    • S. Wasterlain, F. Harel, D. Candusso, D. Hissel, and X. François A new high voltage impedance spectrometer for the diagnostic of the fuel cell stacks J Fuel Cell Sci Technol 8 2011 024502 024511 6
    • (2011) J Fuel Cell Sci Technol , vol.8 , pp. 024502-024511
    • Wasterlain, S.1    Harel, F.2    Candusso, D.3    Hissel, D.4    François, X.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.