메뉴 건너뛰기




Volumn 97, Issue SUPPL. 4, 2014, Pages

Quartz crystal microbalance biosensors: Prospects for point-of-care diagnostics

Author keywords

Biosensor; Point of care testing; Quartz crystal microbalance

Indexed keywords

ALPHA ENOLASE; BIOLOGICAL MARKER; CARBON NANOTUBE; CARCINOEMBRYONIC ANTIGEN; GOLD NANOPARTICLE; MOLECULARLY IMPRINTED POLYMER; PROTEIN P16; PROTEIN P53;

EID: 84902543093     PISSN: 01252208     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (19)

References (45)
  • 1
    • 74449087608 scopus 로고    scopus 로고
    • An overview of foodborne pathogen detection: In the perspective of biosensors
    • Velusamy V, Arshak K, Korostynska O, Oliwa K, Adley C. An overview of foodborne pathogen detection: in the perspective of biosensors. Biotechnol Adv 2010; 28: 232-54.
    • (2010) Biotechnol Adv , vol.28 , pp. 232-254
    • Velusamy, V.1    Arshak, K.2    Korostynska, O.3    Oliwa, K.4    Adley, C.5
  • 2
    • 0000012001 scopus 로고
    • The use of quartz oscillators for weighing thin layers and for microweighing
    • Sauerbrey G. The use of quartz oscillators for weighing thin layers and for microweighing. Zeitschrift Fuer Physik 1959; 115: 206-22.
    • (1959) Zeitschrift Fuer Physik , vol.115 , pp. 206-222
    • Sauerbrey, G.1
  • 3
    • 77949916342 scopus 로고    scopus 로고
    • Novel optimized biofunctional surfaces for Love mode surface acoustic wave based immunosensors
    • Dinh DH, Pascal E, Vellutini L, Bennetau B, Rebire D, Dejous C, et al. Novel optimized biofunctional surfaces for Love mode surface acoustic wave based immunosensors. Sensor Actuator B Chem 2010; 146: 289-96.
    • (2010) Sensor Actuator B Chem , vol.146 , pp. 289-296
    • Dinh, D.H.1    Pascal, E.2    Vellutini, L.3    Bennetau, B.4    Rebire, D.5    Dejous, C.6
  • 4
    • 74449089859 scopus 로고    scopus 로고
    • Hierarchically imprinted polymer substrates for enhanced attachment of Escherichia coli
    • Zhang F, Li H, Wang X, Low HY, Li X. Hierarchically imprinted polymer substrates for enhanced attachment of Escherichia coli. J Colloid Interface Sci 2010; 343: 109-14.
    • (2010) J Colloid Interface Sci , vol.343 , pp. 109-114
    • Zhang, F.1    Li, H.2    Wang, X.3    Low, H.Y.4    Li, X.5
  • 5
    • 77953915540 scopus 로고    scopus 로고
    • Real-time electronic nose based pathogen detection for respiratory intensive care patients
    • Shih C-H, Lin Y-J, Lee K-F, Chien P-Y, Drake P. Real-time electronic nose based pathogen detection for respiratory intensive care patients. Sensor Actuator B Chem 2010; 148: 153-7.
    • (2010) Sensor Actuator B Chem , vol.148 , pp. 153-157
    • Shih, C.-H.1    Lin, Y.-J.2    Lee, K.-F.3    Chien, P.-Y.4    Drake, P.5
  • 6
    • 49849084728 scopus 로고    scopus 로고
    • A new MSPQC for rapid growth and detection of Mycobacterium tuberculosis
    • Ren J, He F, Yi S, Cui X. A new MSPQC for rapid growth and detection of Mycobacterium tuberculosis. Biosens Bioelectron 2008; 24: 403-9.
    • (2008) Biosens Bioelectron , vol.24 , pp. 403-409
    • Ren, J.1    He, F.2    Yi, S.3    Cui, X.4
  • 7
    • 84887098252 scopus 로고    scopus 로고
    • Rapid and multiple detections of staphylococcal enterotoxins by twodimensional molecularly imprinted film-coated QCM sensor
    • Liu N, Li X, Ma X, Ou G, Gao Z. Rapid and multiple detections of staphylococcal enterotoxins by twodimensional molecularly imprinted film-coated QCM sensor. Sensor Actuator B Chem 2014; 194: 326-31.
    • (2014) Sensor Actuator B Chem , vol.194 , pp. 326-331
    • Liu, N.1    Li, X.2    Ma, X.3    Ou, G.4    Gao, Z.5
  • 8
    • 0030865852 scopus 로고    scopus 로고
    • Detection of staphylococcal enterotoxin B employing a piezoelectric crystal immunosensor
    • Harteveld JL, Nieuwenhuizen MS, Wils ER. Detection of staphylococcal enterotoxin B employing a piezoelectric crystal immunosensor. Biosens Bioelectron 1997; 12: 661-7.
    • (1997) Biosens Bioelectron , vol.12 , pp. 661-667
    • Harteveld, J.L.1    Nieuwenhuizen, M.S.2    Wils, E.R.3
  • 9
    • 56449118131 scopus 로고    scopus 로고
    • Carbon nanotubes with enhanced chemiluminescence immunoassay for CCD-based detection of Staphylococcal enterotoxin B in food
    • Yang M, Kostov Y, Bruck HA, Rasooly A. Carbon nanotubes with enhanced chemiluminescence immunoassay for CCD-based detection of Staphylococcal enterotoxin B in food. Anal Chem 2008; 80: 8532-7.
    • (2008) Anal Chem , vol.80 , pp. 8532-8537
    • Yang, M.1    Kostov, Y.2    Bruck, H.A.3    Rasooly, A.4
  • 10
    • 84863050835 scopus 로고    scopus 로고
    • Rapid Detection of Staphylococcal Enterotoxin B by Two-Dimensional Molecularly Imprinted Film-Coated Quartz Crystal Microbalance
    • Liu N, Zhao Z, Chen Y, Gao Z. Rapid Detection of Staphylococcal Enterotoxin B by Two-Dimensional Molecularly Imprinted Film-Coated Quartz Crystal Microbalance. Anal Lett 2012; 45: 283-95.
    • (2012) Anal Lett , vol.45 , pp. 283-295
    • Liu, N.1    Zhao, Z.2    Chen, Y.3    Gao, Z.4
  • 11
    • 67650234213 scopus 로고    scopus 로고
    • Gold nanoparticle-based enhanced chemiluminescence immunosensor for detection of Staphylococcal Enterotoxin B (SEB) in food
    • Yang M, Kostov Y, Bruck HA, Rasooly A. Gold nanoparticle-based enhanced chemiluminescence immunosensor for detection of Staphylococcal Enterotoxin B (SEB) in food. Int J Food Microbiol 2009; 133: 265-71.
    • (2009) Int J Food Microbiol , vol.133 , pp. 265-271
    • Yang, M.1    Kostov, Y.2    Bruck, H.A.3    Rasooly, A.4
  • 12
    • 84867079447 scopus 로고    scopus 로고
    • Elaboration of a reusable immunosensor for the detection of staphylococcal enterotoxin A (SEA) in milk with a quartz crystal microbalance
    • Salmain M, Ghasemi M, Boujday S, Pradier C-M. Elaboration of a reusable immunosensor for the detection of staphylococcal enterotoxin A (SEA) in milk with a quartz crystal microbalance. Sensor Actuator B Chem 2012; 173: 148-56.
    • (2012) Sensor Actuator B Chem , vol.173 , pp. 148-156
    • Salmain, M.1    Ghasemi, M.2    Boujday, S.3    Pradier, C.-M.4
  • 13
    • 84867280611 scopus 로고    scopus 로고
    • Detection of Endotoxin Concentration Using Piezoelectric Based Biosensor System
    • Xiong XL, Wang SM, Zhang Y, Chen LC. Detection of Endotoxin Concentration Using Piezoelectric Based Biosensor System. Appl Mech Mater 2012; 874: 195-6.
    • (2012) Appl Mech Mater , vol.874 , pp. 195-196
    • Xiong, X.L.1    Wang, S.M.2    Zhang, Y.3    Chen, L.C.4
  • 14
    • 18844467253 scopus 로고    scopus 로고
    • Piezoelectric biosensors for real-time monitoring of hybridization and detection of hepatitis C virus
    • Skladal P, dos Santos RC, Yamanaka H, da Costa PI. Piezoelectric biosensors for real-time monitoring of hybridization and detection of hepatitis C virus. J Virol Methods 2004; 117: 145-51.
    • (2004) J Virol Methods , vol.117 , pp. 145-151
    • Skladal, P.1    dos Santos, R.C.2    Yamanaka, H.3    da Costa, P.I.4
  • 15
    • 34347338608 scopus 로고    scopus 로고
    • Development of combined DNA-based piezoelectric biosensors for the simultaneous detection and genotyping of high risk Human Papilloma Virus strains
    • Dell'Atti D, Zavaglia M, Tombelli S, Bertacca G, Cavazzana AO, Bevilacqua G, et al. Development of combined DNA-based piezoelectric biosensors for the simultaneous detection and genotyping of high risk Human Papilloma Virus strains. Clin Chim Acta 2007; 383: 140-6.
    • (2007) Clin Chim Acta , vol.383 , pp. 140-146
    • Dell'Atti, D.1    Zavaglia, M.2    Tombelli, S.3    Bertacca, G.4    Cavazzana, A.O.5    Bevilacqua, G.6
  • 16
    • 37549053310 scopus 로고    scopus 로고
    • Hybridization assay of hepatitis B virus by QCM peptide nucleic acid biosensor
    • Yao C, Zhu T, Tang J, Wu R, Chen Q, Chen M, et al. Hybridization assay of hepatitis B virus by QCM peptide nucleic acid biosensor. Biosens Bioelectron 2008; 23: 879-85.
    • (2008) Biosens Bioelectron , vol.23 , pp. 879-885
    • Yao, C.1    Zhu, T.2    Tang, J.3    Wu, R.4    Chen, Q.5    Chen, M.6
  • 17
    • 84868657618 scopus 로고    scopus 로고
    • The development of DNA-based quartz crystal microbalance integrated with isothermal DNA amplification system for human papillomavirus type 58 detection
    • Prakrankamanant P, Leelayuwat C, Promptmas C, Limpaiboon T, Wanram S, Prasongdee P, et al. The development of DNA-based quartz crystal microbalance integrated with isothermal DNA amplification system for human papillomavirus type 58 detection. Biosens Bioelectron 2013; 40: 252-7.
    • (2013) Biosens Bioelectron , vol.40 , pp. 252-257
    • Prakrankamanant, P.1    Leelayuwat, C.2    Promptmas, C.3    Limpaiboon, T.4    Wanram, S.5    Prasongdee, P.6
  • 18
    • 78650142900 scopus 로고    scopus 로고
    • Ultrasensitive Detection of Cymbidium Mosaic Potexvirus Using a Single-Wall Carbon Nanotube-Functionalized Quartz Crystal Microbalance
    • Chen YS, Hung YC, Chiou JC, Wang HL, Huang HS, Huang LC, et al. Ultrasensitive Detection of Cymbidium Mosaic Potexvirus Using a Single-Wall Carbon Nanotube-Functionalized Quartz Crystal Microbalance. Japanese Journal of Applied Physics 2010; 49: 105103-07.
    • (2010) Japanese Journal of Applied Physics , vol.49 , pp. 105103-105107
    • Chen, Y.S.1    Hung, Y.C.2    Chiou, J.C.3    Wang, H.L.4    Huang, H.S.5    Huang, L.C.6
  • 19
    • 0037430254 scopus 로고    scopus 로고
    • Development of immunochips for the detection of dengue viral antigens
    • Su CC, Wu TZ, Chen LK, Yang HH, Tai DF. Development of immunochips for the detection of dengue viral antigens. Anal Chim Acta 2003; 479: 117-23.
    • (2003) Anal Chim Acta , vol.479 , pp. 117-123
    • Su, C.C.1    Wu, T.Z.2    Chen, L.K.3    Yang, H.H.4    Tai, D.F.5
  • 20
    • 33746622857 scopus 로고    scopus 로고
    • Artificial receptors in serologic tests for the early diagnosis of dengue virus infection
    • Tai DF, Lin CY, Wu TZ, Huang JH, Shu PY. Artificial receptors in serologic tests for the early diagnosis of dengue virus infection. Clin Chem 2006; 52: 1486-91.
    • (2006) Clin Chem , vol.52 , pp. 1486-1491
    • Tai, D.F.1    Lin, C.Y.2    Wu, T.Z.3    Huang, J.H.4    Shu, P.Y.5
  • 21
    • 67649147983 scopus 로고    scopus 로고
    • A method of layer-by-layer gold nanoparticle hybridization in a quartz crystal microbalance DNA sensing system used to detect dengue virus
    • Chen SH, Chuang YC, Lu YC, Lin HC, Yang YL, Lin CS. A method of layer-by-layer gold nanoparticle hybridization in a quartz crystal microbalance DNA sensing system used to detect dengue virus. Nanotechnology 2009; 20: 215501.
    • (2009) Nanotechnology , vol.20 , pp. 215501
    • Chen, S.H.1    Chuang, Y.C.2    Lu, Y.C.3    Lin, H.C.4    Yang, Y.L.5    Lin, C.S.6
  • 22
    • 79952116047 scopus 로고    scopus 로고
    • Detection of label-free cancer biomarkers using nickel nanoislands and quartz crystal microbalance
    • Martinez-Rivas A, Chinestra P, Favre G, Pinaud S, Severac C, Faye JC, et al. Detection of label-free cancer biomarkers using nickel nanoislands and quartz crystal microbalance. Int J Nanomedicine 2010; 5: 661-8.
    • (2010) Int J Nanomedicine , vol.5 , pp. 661-668
    • Martinez-Rivas, A.1    Chinestra, P.2    Favre, G.3    Pinaud, S.4    Severac, C.5    Faye, J.C.6
  • 23
    • 77955665361 scopus 로고    scopus 로고
    • Piezoelectric immunosensor based on gold nanoparticles capped with mixed selfassembled monolayer for detection of carcinoembryonic antigen
    • Shen G, Lu J. Piezoelectric immunosensor based on gold nanoparticles capped with mixed selfassembled monolayer for detection of carcinoembryonic antigen. Thin Solid Films 2010; 518: 5010-3.
    • (2010) Thin Solid Films , vol.518 , pp. 5010-5013
    • Shen, G.1    Lu, J.2
  • 24
    • 84872588147 scopus 로고    scopus 로고
    • Quartz crystal microbalance with dissipation (QCM-D) as tool to exploit antigen-antibody interactions in pancreatic ductal adenocarcinomadetection
    • Bianco M, Aloisi A, Arima V, Capello M, Ferri-Borgogno S, Novelli F, et al. Quartz crystal microbalance with dissipation (QCM-D) as tool to exploit antigen-antibody interactions in pancreatic ductal adenocarcinomadetection. Biosens Bioelectron 2013; 42: 646-52.
    • (2013) Biosens Bioelectron , vol.42 , pp. 646-652
    • Bianco, M.1    Aloisi, A.2    Arima, V.3    Capello, M.4    Ferri-Borgogno, S.5    Novelli, F.6
  • 25
    • 0037307872 scopus 로고    scopus 로고
    • Prognostic prediction of the immunohistochemical expression of p53 and p16 in resected non-small cell lung cancer
    • Cheng YL, Lee SC, Harn HJ, Chen CJ, Chang YC, Chen JC, et al. Prognostic prediction of the immunohistochemical expression of p53 and p16 in resected non-small cell lung cancer. Eur J Cardiothorac Surg 2003; 23: 221-8.
    • (2003) Eur J Cardiothorac Surg , vol.23 , pp. 221-228
    • Cheng, Y.L.1    Lee, S.C.2    Harn, H.J.3    Chen, C.J.4    Chang, Y.C.5    Chen, J.C.6
  • 27
    • 84863889254 scopus 로고    scopus 로고
    • Cancer biomarker detection in serum samples using surface plasmon resonance and quartz crystal microbalance sensors with nanoparticle signal amplification
    • Uludag Y, Tothill IE. Cancer biomarker detection in serum samples using surface plasmon resonance and quartz crystal microbalance sensors with nanoparticle signal amplification. Anal Chem 2012; 84: 5898-904.
    • (2012) Anal Chem , vol.84 , pp. 5898-5904
    • Uludag, Y.1    Tothill, I.E.2
  • 29
    • 22044444009 scopus 로고    scopus 로고
    • Nanotechnology in clinical laboratory diagnostics
    • Jain KK. Nanotechnology in clinical laboratory diagnostics. Clin Chim Acta 2005; 358: 37-54.
    • (2005) Clin Chim Acta , vol.358 , pp. 37-54
    • Jain, K.K.1
  • 30
    • 17944366258 scopus 로고    scopus 로고
    • Nanostructures in biodiagnostics
    • Rosi NL, Mirkin CA. Nanostructures in biodiagnostics. Chem Rev 2005; 105: 1547-62.
    • (2005) Chem Rev , vol.105 , pp. 1547-1562
    • Rosi, N.L.1    Mirkin, C.A.2
  • 31
    • 77649189109 scopus 로고    scopus 로고
    • Nanotechnologies for pathogen detection: Future alternatives?
    • Fournier-Wirth C, Coste J. Nanotechnologies for pathogen detection: Future alternatives? Biologicals 2010; 38: 9-13.
    • (2010) Biologicals , vol.38 , pp. 9-13
    • Fournier-Wirth, C.1    Coste, J.2
  • 32
    • 76849094649 scopus 로고    scopus 로고
    • Emerging nanotechnology-based strategies for the identification of microbial pathogenesis
    • Kaittanis C, Santra S, Perez JM. Emerging nanotechnology-based strategies for the identification of microbial pathogenesis. Adv Drug Deliv Rev 2010; 62: 408-23.
    • (2010) Adv Drug Deliv Rev , vol.62 , pp. 408-423
    • Kaittanis, C.1    Santra, S.2    Perez, J.M.3
  • 33
    • 33947225700 scopus 로고    scopus 로고
    • The present and future of nanotechnology in human health care
    • Sahoo SK, Parveen S, Panda JJ. The present and future of nanotechnology in human health care. Nanomedicine 2007; 3: 20-31.
    • (2007) Nanomedicine , vol.3 , pp. 20-31
    • Sahoo, S.K.1    Parveen, S.2    Panda, J.J.3
  • 34
    • 0034680544 scopus 로고    scopus 로고
    • Piezoelectric Mass-Sensing Devices as Biosensors-An Alternative to Optical Biosensors?
    • Janshoff A, Galla HJ, Steinem C. Piezoelectric Mass-Sensing Devices as Biosensors-An Alternative to Optical Biosensors? Angew Chem Int Ed Engl 2000; 39: 4004-32.
    • (2000) Angew Chem Int Ed Engl , vol.39 , pp. 4004-4032
    • Janshoff, A.1    Galla, H.J.2    Steinem, C.3
  • 35
    • 84880372978 scopus 로고    scopus 로고
    • Real-time and sensitive detection of Salmonella Typhimurium using an automated quartz crystal microbalance (QCM) instrument with nanoparticles amplification
    • Salam F, Uludag Y, Tothill IE. Real-time and sensitive detection of Salmonella Typhimurium using an automated quartz crystal microbalance (QCM) instrument with nanoparticles amplification. Talanta 2013; 115: 761-7.
    • (2013) Talanta , vol.115 , pp. 761-767
    • Salam, F.1    Uludag, Y.2    Tothill, I.E.3
  • 36
    • 0038022631 scopus 로고    scopus 로고
    • Application of a flow-type antibody sensor to the detection of Escherichia coli in various foods
    • Kim N, Park IS. Application of a flow-type antibody sensor to the detection of Escherichia coli in various foods. Biosens Bioelectron 2003; 18: 1101-7.
    • (2003) Biosens Bioelectron , vol.18 , pp. 1101-1107
    • Kim, N.1    Park, I.S.2
  • 37
    • 29144446032 scopus 로고    scopus 로고
    • A nanoparticle amplification based quartz crystal microbalance DNA sensor for detection of Escherichia coli O157:H7
    • Mao X, Yang L, Su XL, Li Y. A nanoparticle amplification based quartz crystal microbalance DNA sensor for detection of Escherichia coli O157:H7. Biosens Bioelectron 2006; 21: 1178-85.
    • (2006) Biosens Bioelectron , vol.21 , pp. 1178-1185
    • Mao, X.1    Yang, L.2    Su, X.L.3    Li, Y.4
  • 38
    • 42449125685 scopus 로고    scopus 로고
    • The Escherichia coli O157:H7 DNA detection on a gold nanoparticle-enhanced piezoelectric biosensor
    • Wang LJ, Wei QS, Wu CS, Hu ZY, Ji J, Wang P. The Escherichia coli O157:H7 DNA detection on a gold nanoparticle-enhanced piezoelectric biosensor. Chin Sci Bull 2008; 53: 1175-84.
    • (2008) Chin Sci Bull , vol.53 , pp. 1175-1184
    • Wang, L.J.1    Wei, Q.S.2    Wu, C.S.3    Hu, Z.Y.4    Ji, J.5    Wang, P.6
  • 39
    • 84861918235 scopus 로고    scopus 로고
    • DNA-based biosensor platforms for the detection of TP53 mutation
    • Altintas Z, Tothill IE. DNA-based biosensor platforms for the detection of TP53 mutation. Sensor Actuator B Chem 2012; 169: 188-94.
    • (2012) Sensor Actuator B Chem , vol.169 , pp. 188-194
    • Altintas, Z.1    Tothill, I.E.2
  • 41
    • 67650085486 scopus 로고    scopus 로고
    • Rapid detection of human papilloma virus using a novel leaky surface acoustic wave peptide nucleic acid biosensor
    • Wang Y, Chen M, Zhang L, Ding Y, Luo Y, Xu Q, et al. Rapid detection of human papilloma virus using a novel leaky surface acoustic wave peptide nucleic acid biosensor. Biosens Bioelectron 2009; 24: 3455-60.
    • (2009) Biosens Bioelectron , vol.24 , pp. 3455-3460
    • Wang, Y.1    Chen, M.2    Zhang, L.3    Ding, Y.4    Luo, Y.5    Xu, Q.6
  • 42
    • 43649089022 scopus 로고    scopus 로고
    • A simple and direct electrochemical detection of interferon-gamma using its RNA and DNA aptamers
    • Min K, Cho M, Han SY, Shim YB, Ku J, Ban C. A simple and direct electrochemical detection of interferon-gamma using its RNA and DNA aptamers. Biosens Bioelectron 2008; 23: 1819-24.
    • (2008) Biosens Bioelectron , vol.23 , pp. 1819-1824
    • Min, K.1    Cho, M.2    Han, S.Y.3    Shim, Y.B.4    Ku, J.5    Ban, C.6
  • 43
    • 77955493608 scopus 로고    scopus 로고
    • Detection of non-amplified Mycobacterium tuberculosis genomic DNA using piezoelectric DNA-based biosensors
    • Kaewphinit T, Santiwatanakul S, Promptmas C, Chansiri K. Detection of non-amplified Mycobacterium tuberculosis genomic DNA using piezoelectric DNA-based biosensors. Sensors (Basel) 2010; 10: 1846-58.
    • (2010) Sensors (Basel) , vol.10 , pp. 1846-1858
    • Kaewphinit, T.1    Santiwatanakul, S.2    Promptmas, C.3    Chansiri, K.4
  • 44
    • 0036011041 scopus 로고    scopus 로고
    • Rapid diagnosis of M. tuberculosis using a piezoelectric immunosensor
    • He F, Zhang L. Rapid diagnosis of M. tuberculosis using a piezoelectric immunosensor. Anal Sci 2002; 18: 397-401.
    • (2002) Anal Sci , vol.18 , pp. 397-401
    • He, F.1    Zhang, L.2
  • 45
    • 77958046234 scopus 로고    scopus 로고
    • Platelet aggregation monitoring with a newly developed quartz crystal microbalance system as an alternative to optical platelet aggregometry
    • Sinn S, Muller L, Drechsel H, Wandel M, Northoff H, Ziemer G, et al. Platelet aggregation monitoring with a newly developed quartz crystal microbalance system as an alternative to optical platelet aggregometry. Analyst 2010; 135: 2930-8.
    • (2010) Analyst , vol.135 , pp. 2930-2938
    • Sinn, S.1    Muller, L.2    Drechsel, H.3    Wandel, M.4    Northoff, H.5    Ziemer, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.