Volumn 11, Issue 4, 2014, Pages 375-381

Robotics in invasive cardiac electrophysiology

Author keywords

Ablation; Automation; Cardiac electrophysiology; Efficacy and safety; Electromagnetic; Electromechanical; Magnetic; Mapping

Indexed keywords

ABLATION; AUTOMATION; ELECTRONIC GUIDANCE SYSTEMS; ELECTROPHYSIOLOGY; MAPPING; NAVIGATION SYSTEMS; NEUROLOGY; ROBOTICS;

EID: 84902494216     PISSN: 17434440     EISSN: 17452422     Source Type: Journal    
DOI: 10.1586/17434440.2014.916207     Document Type: Review
Times cited : (13)

References (47)
  • 1
    • 0017352827 scopus 로고
    • Cryosurgical ablation of AV node-his bundle-new method for producing AV block
    • Harrison L, Gallagher JJ, Kasell J, et al. Cryosurgical ablation of AV node-his bundle-new method for producing AV block. Circulation 1977;55(3):463-70
    • (1977) Circulation , vol.55 , Issue.3 , pp. 463-470
    • Harrison, L.1    Gallagher, J.J.2    Kasell, J.3
  • 2
    • 0344873703 scopus 로고    scopus 로고
    • Magnetic guidance system for cardiac electrophysiology-A prospective trial of safety and efficacy in humans
    • Faddis MN, Chen J, Osborn J, et al. Magnetic guidance system for cardiac electrophysiology-A prospective trial of safety and efficacy in humans. J Am Coll Cardiol 2003;42(11):1952-8
    • (2003) J Am Coll Cardiol , vol.42 , Issue.11 , pp. 1952-1958
    • Faddis, M.N.1    Chen, J.2    Osborn, J.3
  • 3
    • 85067776822 scopus 로고    scopus 로고
    • Robotically assisted ablation of atrial fibrillation: A systematic review and meta-analysis
    • Shurrab M, Danon A, Lashevsky I, et al. Robotically assisted ablation of atrial fibrillation: a systematic review and meta-analysis. Int J Cardiol 2013;10(13): 01669-0
    • (2013) Int J Cardiol , vol.10 , Issue.13 , pp. 01669-01670
    • Shurrab, M.1    Danon, A.2    Lashevsky, I.3
  • 4
    • 84875986249 scopus 로고    scopus 로고
    • Safety and feasibility of robotic percutaneous coronary intervention PRECISE (Percutaneous Robotically-Enhanced Coronary Intervention) Study
    • Weisz G, Metzger DC, Caputo RP, et al. Safety and feasibility of robotic percutaneous coronary intervention PRECISE (Percutaneous Robotically-Enhanced Coronary Intervention) Study. J Am Coll Cardiol 2013;61(15): 1596-600
    • (2013) J Am Coll Cardiol , vol.61 , Issue.15 , pp. 1596-1600
    • Weisz, G.1    Metzger, D.C.2    Caputo, R.P.3
  • 5
    • 0037016002 scopus 로고    scopus 로고
    • Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation
    • Faddis MN, Blume W, Finney J, et al. Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation. Circulation 2002;106(23): 2980-5
    • (2002) Circulation , vol.106 , Issue.23 , pp. 2980-2985
    • Faddis, M.N.1    Blume, W.2    Finney, J.3
  • 6
    • 84881097327 scopus 로고    scopus 로고
    • Remote magnetic navigation for catheter ablation of atrioventricular nodal reentrant tachycardia: A systematic review and meta-analysis
    • Shurrab M, Danon A, Crystal A, et al. Remote magnetic navigation for catheter ablation of atrioventricular nodal reentrant tachycardia: a systematic review and meta-analysis. Expert Rev Cardiovasc Ther 2013;11(7):829-36
    • (2013) Expert Rev Cardiovasc Ther , vol.11 , Issue.7 , pp. 829-836
    • Shurrab, M.1    Danon, A.2    Crystal, A.3
  • 7
    • 55249107227 scopus 로고    scopus 로고
    • Remote magnetic navigation-assisted catheter ablation enhances catheter stability and ablation success with lower catheter temperatures
    • Davis DR, Tang ASL, Gollob MH, et al. Remote magnetic navigation-assisted catheter ablation enhances catheter stability and ablation success with lower catheter temperatures. Pacing Clin Electrophysiol 2008;31(7):893-8
    • (2008) Pacing Clin Electrophysiol , vol.31 , Issue.7 , pp. 893-898
    • Davis, D.R.1    Tang, A.S.L.2    Gollob, M.H.3
  • 8
    • 67650383729 scopus 로고    scopus 로고
    • Robotic magnetic navigation for ablation of human arrhythmias: Initial experience
    • Latcu DG, Ricard P, Zarqane N, et al. Robotic magnetic navigation for ablation of human arrhythmias: initial experience. Arch Cardiovasc Dis 2009;102(5):419-25
    • (2009) Arch Cardiovasc Dis , vol.102 , Issue.5 , pp. 419-425
    • Latcu, D.G.1    Ricard, P.2    Zarqane, N.3
  • 9
    • 73649099196 scopus 로고    scopus 로고
    • Slow pathway radiofrequency ablation in patients with AVNRT: Junctional rhythm is less frequent during magnetic navigation ablation than with the conventional technique
    • Ricard P, Latcu DG, Yaici K, et al. Slow pathway radiofrequency ablation in patients with AVNRT: junctional rhythm is less frequent during magnetic navigation ablation than with the conventional technique. Pacing Clin Electrophysiol 2010; 33(1):11-15
    • (2010) Pacing Clin Electrophysiol , vol.33 , Issue.1 , pp. 11-15
    • Ricard, P.1    Latcu, D.G.2    Yaici, K.3
  • 10
    • 80053573766 scopus 로고    scopus 로고
    • Remote magnetic versus manual catheters: Evaluation of ablation effect in atrial fibrillation by myocardial marker levels
    • Solheim E, Off MK, Hoff PI, et al. Remote magnetic versus manual catheters: evaluation of ablation effect in atrial fibrillation by myocardial marker levels. J Interv Card Electrophysiol 2011;32(1):37-43
    • (2011) J Interv Card Electrophysiol , vol.32 , Issue.1 , pp. 37-43
    • Solheim, E.1    Off, M.K.2    Hoff, P.I.3
  • 11
    • 82455194858 scopus 로고    scopus 로고
    • Luminal esophageal temperature rise and esophageal lesion formation following remote-controlled magnetic pulmonary vein isolation
    • Konstantinidou M, Wissner E, Chun JKR, et al. Luminal esophageal temperature rise and esophageal lesion formation following remote-controlled magnetic pulmonary vein isolation. Heart Rhythm 2011;8(12): 1875-80
    • (2011) Heart Rhythm , vol.8 , Issue.12 , pp. 1875-1880
    • Konstantinidou, M.1    Wissner, E.2    Chun, J.K.R.3
  • 13
    • 77950212487 scopus 로고    scopus 로고
    • Atrial fibrillation ablation by aortic retrograde approach using a magnetic navigation system
    • Miyazaki S, Nault I, Haissaguerre M, Hocini M. Atrial fibrillation ablation by aortic retrograde approach using a magnetic navigation system. J Cardiovasc Electrophysiol 2010;21(4):455-7
    • (2010) J Cardiovasc Electrophysiol , vol.21 , Issue.4 , pp. 455-457
    • Miyazaki, S.1    Nault, I.2    Haissaguerre, M.3    Hocini, M.4
  • 14
    • 84865827152 scopus 로고    scopus 로고
    • Ablation of post transplant atrial flutter and pseudo-fibrillation using magnetic navigation via a superior approach
    • Tung R, Shivkumar K, Mandapati R. Ablation of post transplant atrial flutter and pseudo-fibrillation using magnetic navigation via a superior approach. Indian Pacing Electrophysiol J 2012;12(5): 229-32
    • (2012) Indian Pacing Electrophysiol J , vol.12 , Issue.5 , pp. 229-232
    • Tung, R.1    Shivkumar, K.2    Mandapati, R.3
  • 15
    • 84872194970 scopus 로고    scopus 로고
    • Ablation of a resistant right atrial appendage tachycardia using a magnetic navigation system
    • Khan MK, Elmouchi D. Ablation of a resistant right atrial appendage tachycardia using a magnetic navigation system. Pacing Clin Electrophysiol 2013;36(1):E15-18
    • (2013) Pacing Clin Electrophysiol , vol.36 , Issue.1
    • Khan, M.K.1    Elmouchi, D.2
  • 16
    • 79955400144 scopus 로고    scopus 로고
    • Catheter ablation of right ventricular outflow tract tachycardia: A simplified remote-controlled approach
    • Konstantinidou M, Koektuerk B, Wissner E, et al. Catheter ablation of right ventricular outflow tract tachycardia: a simplified remote-controlled approach. Europace 2011; 13(5):696-700
    • (2011) Europace , vol.13 , Issue.5 , pp. 696-700
    • Konstantinidou, M.1    Koektuerk, B.2    Wissner, E.3
  • 18
    • 0032514733 scopus 로고    scopus 로고
    • Risk to patients from radiation associated with radiofrequency ablation for supraventricular tachycardia
    • Kovoor P, Ricciardello M, Collins L, et al. Risk to patients from radiation associated with radiofrequency ablation for supraventricular tachycardia. Circulation 1998;98(15):1534-40
    • (1998) Circulation , vol.98 , Issue.15 , pp. 1534-1540
    • Kovoor, P.1    Ricciardello, M.2    Collins, L.3
  • 19
    • 0035800035 scopus 로고    scopus 로고
    • Accurate assessment of patient effective radiation dose and associated detriment risk from radiofrequency catheter ablation procedures
    • Perisinakis K, Damilakis J, Theocharopoulos N, et al. Accurate assessment of patient effective radiation dose and associated detriment risk from radiofrequency catheter ablation procedures. Circulation 2001;104(1):58-62
    • (2001) Circulation , vol.104 , Issue.1 , pp. 58-62
    • Perisinakis, K.1    Damilakis, J.2    Theocharopoulos, N.3
  • 20
    • 84880396840 scopus 로고    scopus 로고
    • Three-dimensional localization versus fluoroscopically only guided ablations: A meta-analysis
    • Shurrab M, Laish-Farkash A, Lashevsky I, et al. Three-dimensional localization versus fluoroscopically only guided ablations: a meta-analysis. Scand Cardiovasc J 2013; 47(4):200-9
    • (2013) Scand Cardiovasc J , vol.47 , Issue.4 , pp. 200-209
    • Shurrab, M.1    Laish-Farkash, A.2    Lashevsky, I.3
  • 21
    • 33846391950 scopus 로고    scopus 로고
    • Initial clinical experience with cardiac resynchronization therapy utilizing a magnetic navigation system
    • Gallagher P, Martin L, Angel L, Tomassoni G. Initial clinical experience with cardiac resynchronization therapy utilizing a magnetic navigation system. J Cardiovasc Electrophysiol 2007;18(2): 174-80
    • (2007) J Cardiovasc Electrophysiol , vol.18 , Issue.2 , pp. 174-180
    • Gallagher, P.1    Martin, L.2    Angel, L.3    Tomassoni, G.4
  • 22
    • 78049514461 scopus 로고    scopus 로고
    • Interference of remote magnetic catheter navigation and ablation with implanted devices for pacing and defibrillation
    • Luthje L, Vollmann D, Seegers J, et al. Interference of remote magnetic catheter navigation and ablation with implanted devices for pacing and defibrillation. Europace 2010;12(11):1574-80
    • (2010) Europace , vol.12 , Issue.11 , pp. 1574-1580
    • Luthje, L.1    Vollmann, D.2    Seegers, J.3
  • 23
    • 84870208547 scopus 로고    scopus 로고
    • Novel robotic catheter manipulation system integrated with remote magnetic navigation for fully remote ablation of atrial tachyarrhythmias: A two-centre evaluation
    • Nolker G, Gutleben KJ, Muntean B, et al. Novel robotic catheter manipulation system integrated with remote magnetic navigation for fully remote ablation of atrial tachyarrhythmias: a two-centre evaluation. Europace 2012;14(12):1715-18
    • (2012) Europace , vol.14 , Issue.12 , pp. 1715-1718
    • Nolker, G.1    Gutleben, K.J.2    Muntean, B.3
  • 24
    • 78049504921 scopus 로고    scopus 로고
    • Remote-controlled magnetic pulmonary vein isolation using a new irrigated-tip catheter in patients with atrial fibrillation
    • Chun KRJ, Wissner E, Koektuerk B, et al. Remote-controlled magnetic pulmonary vein isolation using a new irrigated-tip catheter in patients with atrial fibrillation. CircArrhythm Electrophysiol 2010;3(5): 458-64
    • (2010) CircArrhythm Electrophysiol , vol.3 , Issue.5 , pp. 458-464
    • Chun, K.R.J.1    Wissner, E.2    Koektuerk, B.3
  • 25
    • 34249664413 scopus 로고    scopus 로고
    • View-synchronized robotic image-guided therapy for atrial fibrillation ablation-experimental validation and clinical feasibility
    • Reddy VY, Neuzil P, Malchano ZJ, et al. View-synchronized robotic image-guided therapy for atrial fibrillation ablation-experimental validation and clinical feasibility. Circulation 2007;115(21): 2705-14
    • (2007) Circulation , vol.115 , Issue.21 , pp. 2705-2714
    • Reddy, V.Y.1    Neuzil, P.2    Malchano, Z.J.3
  • 26
    • 70450216054 scopus 로고    scopus 로고
    • Ablation of atrial fibrillation utilizing robotic catheter navigation in comparison to manual navigation and ablation: Single-center experience
    • Di Biase L, Wang Y, Horton R, et al. Ablation of atrial fibrillation utilizing robotic catheter navigation in comparison to manual navigation and ablation: single-center experience. J Cardiovasc Electrophysiol 2009;20(12):1328-35
    • (2009) J Cardiovasc Electrophysiol , vol.20 , Issue.12 , pp. 1328-1335
    • Di Biase, L.1    Wang, Y.2    Horton, R.3
  • 27
    • 78049421746 scopus 로고    scopus 로고
    • Remote robotic catheter ablation for atrial fibrillation: How fast is it learned and what benefits can be earned?
    • Rillig A, Meyerfeldt U, Birkemeyer R, et al. Remote robotic catheter ablation for atrial fibrillation: how fast is it learned and what benefits can be earned? J Interv Card Electrophysiol 2010;29(2):109-17
    • (2010) J Interv Card Electrophysiol , vol.29 , Issue.2 , pp. 109-117
    • Rillig, A.1    Meyerfeldt, U.2    Birkemeyer, R.3
  • 28
    • 70349446735 scopus 로고    scopus 로고
    • Remote robotic navigation and electroanatomical mapping for ablation of atrial fibrillation considerations for navigation and impact on procedural outcome
    • Schmidt B, Tilz RR, Neven K, et al. Remote robotic navigation and electroanatomical mapping for ablation of atrial fibrillation considerations for navigation and impact on procedural outcome. Circ Arrhythm Electrophysiol 2009;2(2):120-8
    • (2009) Circ Arrhythm Electrophysiol , vol.2 , Issue.2 , pp. 120-128
    • Schmidt, B.1    Tilz, R.R.2    Neven, K.3
  • 29
    • 84861972389 scopus 로고    scopus 로고
    • Improved electrogram attenuation during ablation of paroxysmal atrial fibrillation with the hansen robotic system
    • Duncan ER, Finlay M, Page SP, et al. Improved electrogram attenuation during ablation of paroxysmal atrial fibrillation with the hansen robotic system. Pacing Clin Electrophysiol 2012;35(6):730-8
    • (2012) Pacing Clin Electrophysiol , vol.35 , Issue.6 , pp. 730-738
    • Duncan, E.R.1    Finlay, M.2    Page, S.P.3
  • 31
    • 82455187942 scopus 로고    scopus 로고
    • Robotic catheter ablation of left ventricular tachycardia: Initial experience
    • Valderrabano M, Dave AS, Baez-Escudero JL, Rami T. Robotic catheter ablation of left ventricular tachycardia: initial experience. Heart Rhythm 2011; 8(12):1837-46
    • (2011) Heart Rhythm , vol.8 , Issue.12 , pp. 1837-1846
    • Valderrabano, M.1    Dave, A.S.2    Baez-Escudero, J.L.3    Rami, T.4
  • 32
    • 57149140258 scopus 로고    scopus 로고
    • Robotic versus conventional ablation for common-type atrial flutter: A prospective randomized trial to evaluate the effectiveness of remote catheter navigation
    • Steven D, Rostock T, Servatius H, et al. Robotic versus conventional ablation for common-type atrial flutter: a prospective randomized trial to evaluate the effectiveness of remote catheter navigation. Heart Rhythm 2008;5(11):1556-60
    • (2008) Heart Rhythm , vol.5 , Issue.11 , pp. 1556-1560
    • Steven, D.1    Rostock, T.2    Servatius, H.3
  • 33
    • 84890565932 scopus 로고    scopus 로고
    • Left atrial isthmus line ablation using a remote robotic navigation system: Feasibility, efficacy and long-term outcome
    • Rillig A, Schmidt B, Feige B, et al. Left atrial isthmus line ablation using a remote robotic navigation system: feasibility, efficacy and long-term outcome. Clin Res Cardiol 2013;102(12):885-93
    • (2013) Clin Res Cardiol , vol.102 , Issue.12 , pp. 885-893
    • Rillig, A.1    Schmidt, B.2    Feige, B.3
  • 34
    • 84866083628 scopus 로고    scopus 로고
    • Worldwide experience with the robotic navigation system in catheter ablation of atrial fibrillation: Methodology, efficacy and safety
    • Bai R, Di Biase L, Valderrabano M, et al. Worldwide Experience with the Robotic Navigation System in Catheter Ablation of Atrial Fibrillation: methodology, Efficacy and Safety. J Cardiovasc Electrophysiol 2012;23(8):820-6
    • (2012) J Cardiovasc Electrophysiol , vol.23 , Issue.8 , pp. 820-826
    • Bai, R.1    Di Biase, L.2    Valderrabano, M.3
  • 35
    • 44949220178 scopus 로고    scopus 로고
    • Atrial fibrillation ablation using a robotic catheter remote control system-Initial human experience and long-term follow-up results
    • Saliba W, Reddy VY, Wazni O, et al. Atrial fibrillation ablation using a robotic catheter remote control system-Initial human experience and long-term follow-up results. J Am Coll Cardiol 2008;51(25): 2407-11
    • (2008) J Am Coll Cardiol , vol.51 , Issue.25 , pp. 2407-2411
    • Saliba, W.1    Reddy, V.Y.2    Wazni, O.3
  • 36
    • 84871989398 scopus 로고    scopus 로고
    • Study Design of the man and machine trial: A prospective international controlled noninferiority trial comparing manual with robotic catheter ablation for treatment of atrial fibrillation
    • Rillig A, Schmidt B, Steven D, et al. Study Design of the man and machine trial: a prospective international controlled noninferiority trial comparing manual with robotic catheter ablation for treatment of atrial fibrillation. J Cardiovasc Electrophysiol 2013;24(1):40-6
    • (2013) J Cardiovasc Electrophysiol , vol.24 , Issue.1 , pp. 40-46
    • Rillig, A.1    Schmidt, B.2    Steven, D.3
  • 37
    • 63049135802 scopus 로고    scopus 로고
    • Relationship between catheter forces, lesion characteristics, "Popping," and char formation: Experience with robotic navigation system
    • Di Biase L, Natale A, Barrett C, et al. Relationship between catheter forces, lesion characteristics, "Popping," and char formation: experience with robotic navigation system. J Cardiovasc Electrophysiol 2009;20(4):436-40
    • (2009) J Cardiovasc Electrophysiol , vol.20 , Issue.4 , pp. 436-440
    • Di Biase, L.1    Natale, A.2    Barrett, C.3
  • 38
    • 70350589325 scopus 로고    scopus 로고
    • Experience with the hansen robotic system for atrial fibrillation ablation-lessons learned and techniques modified: Hansen in the real world
    • Wazni OM, Barrett C, Martin DO, et al. Experience with the hansen robotic system for atrial fibrillation ablation-lessons learned and techniques modified: hansen in the real world. J Cardiovasc Electrophysiol 2009; 20(11):1193-6
    • (2009) J Cardiovasc Electrophysiol , vol.20 , Issue.11 , pp. 1193-1196
    • Wazni, O.M.1    Barrett, C.2    Martin, D.O.3
  • 39
    • 77955243893 scopus 로고    scopus 로고
    • Unexpected high incidence of esophageal injury following pulmonary vein isolation using robotic navigation
    • Tilz RR, Chun KRJ, Metzner A, et al. Unexpected high incidence of esophageal injury following pulmonary vein isolation using robotic navigation. J Cardiovasc Electrophysiol 2010;21(8):853-8
    • (2010) J Cardiovasc Electrophysiol , vol.21 , Issue.8 , pp. 853-858
    • Tilz, R.R.1    Chun, K.R.J.2    Metzner, A.3
  • 40
    • 80052016136 scopus 로고    scopus 로고
    • RF ablation of WPW syndrome using ensite array balloon mapping and Hansen-Sensei robotic cool-path catheter
    • Chasan R, Soydan N, Burgazli MK, et al. RF ablation of WPW syndrome using ensite array balloon mapping and Hansen-Sensei robotic cool-path catheter. Anadolu Kardiyol Derg 2011;11(6):567-7
    • (2011) Anadolu Kardiyol Derg , vol.11 , Issue.6 , pp. 567-577
    • Chasan, R.1    Soydan, N.2    Burgazli, M.K.3
  • 41
    • 84902509577 scopus 로고    scopus 로고
    • Cavo-tricuspid isthmus radiofrequency ablation using a novel remote navigation catheter system in patients with typical atrial flutter
    • Lopez-Gil M, Salgado R, Merino JL, et al. Cavo-tricuspid isthmus radiofrequency ablation using a novel remote navigation catheter system in patients with typical atrial flutter. Europace 2013;20:20
    • (2013) Europace , vol.20 , pp. 20
    • Lopez-Gil, M.1    Salgado, R.2    Merino, J.L.3
  • 42
    • 84879984434 scopus 로고    scopus 로고
    • First experience with a novel robotic remote catheter system: AMIGO (TM) mapping trial
    • Khan EM, Frumkin W, Ng GA, et al. First experience with a novel robotic remote catheter system: AMIGO (TM) mapping trial. J Interv Card Electrophysiol 2013; 37(2):121-9
    • (2013) J Interv Card Electrophysiol , vol.37 , Issue.2 , pp. 121-129
    • Khan, E.M.1    Frumkin, W.2    Ng, G.A.3
  • 43
    • 84555203870 scopus 로고    scopus 로고
    • Dynamically shaped magnetic fields initial animal validation of a new remote electrophysiology catheter guidance and control system
    • Gang ES, Nguyen BL, Shachar Y, et al. Dynamically shaped magnetic fields initial animal validation of a new remote electrophysiology catheter guidance and control system. Circ Arrhythm Electrophysiol 2011;4(5):770-U287
    • (2011) Circ Arrhythm Electrophysiol , vol.4 , Issue.5
    • Gang, E.S.1    Nguyen, B.L.2    Shachar, Y.3
  • 44
    • 84884188449 scopus 로고    scopus 로고
    • Physician-controlled costs: The choice of equipment used for atrial fibrillation ablation
    • Winkle RA, Mead RH, Engel G, et al. Physician-controlled costs: the choice of equipment used for atrial fibrillation ablation. J Interv Card Electrophysiol 2013; 36(2):157-65
    • (2013) J Interv Card Electrophysiol , vol.36 , Issue.2 , pp. 157-165
    • Winkle, R.A.1    Mead, R.H.2    Engel, G.3
  • 45
    • 33645409828 scopus 로고    scopus 로고
    • Robotic magnetic navigation for atrial fibrillation ablation
    • Pappone C, Vicedomini G, Manguso F, et al. Robotic magnetic navigation for atrial fibrillation ablation. J Am Coll Cardiol 2006;47(7):1390-400
    • (2006) J Am Coll Cardiol , vol.47 , Issue.7 , pp. 1390-1400
    • Pappone, C.1    Vicedomini, G.2    Manguso, F.3
  • 46
    • 84882697532 scopus 로고    scopus 로고
    • A survey of German centres performing invasive electrophysiology: Structure, procedures, and training positions
    • Neuberger HR, Tilz RR, Bonnemeier H, et al. A survey of German centres performing invasive electrophysiology: structure, procedures, and training positions. Europace 2013;15(12):1741-6
    • (2013) Europace , vol.15 , Issue.12 , pp. 1741-1746
    • Neuberger, H.R.1    Tilz, R.R.2    Bonnemeier, H.3
  • 47
    • 85067743907 scopus 로고    scopus 로고
    • Snapshot of invasive electrophysiology in Canada in 2012: Results from the national survey
    • Shurrab M, Fishman E, Kaoutskaia A, et al. Snapshot of invasive electrophysiology in Canada in 2012: results from the national survey. Can J Cardiol 2013;29(10):S187-8
    • (2013) Can J Cardiol , vol.29 , Issue.10
    • Shurrab, M.1    Fishman, E.2    Kaoutskaia, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.