메뉴 건너뛰기




Volumn 51, Issue 25, 2008, Pages 2407-2411

Atrial Fibrillation Ablation Using a Robotic Catheter Remote Control System. Initial Human Experience and Long-Term Follow-Up Results

(16)  Saliba, Walid a   Reddy, Vivek Y b   Wazni, Oussama a   Cummings, Jennifer E a   Burkhardt, J David a   Haissaguerre, Michel c   Kautzner, Josef d   Peichl, Petr d   Neuzil, Petr g   Schibgilla, Volker e   Noelker, Georg e   Brachmann, Johannes e   Di Biase, Luigi a,f   Barrett, Conor a   Jais, Pierre c   Natale, Andrea h,i,j  


Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AMBULATORY MONITORING; ARTICLE; CATHETER ABLATION; CLINICAL ARTICLE; DISEASE DURATION; FEASIBILITY STUDY; FEMALE; FOLLOW UP; HEART ARRHYTHMIA; HEART ATRIUM ARRHYTHMIA; HEART ATRIUM FIBRILLATION; HEART ATRIUM FLUTTER; HEART CATHETER; HEART LEFT ATRIUM; HEART RIGHT ATRIUM; HOLTER MONITORING; HUMAN; MALE; PRIORITY JOURNAL; PULMONARY VEIN; RADIOFREQUENCY ABLATION; RECURRENT DISEASE; ROBOTICS; SUPERIOR CAVA VEIN; THREE DIMENSIONAL IMAGING; TRICUSPID VALVE;

EID: 44949220178     PISSN: 07351097     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jacc.2008.03.027     Document Type: Article
Times cited : (226)

References (14)
  • 1
    • 0033580207 scopus 로고    scopus 로고
    • Radio-frequency ablation as treatment for cardiac arrhythmias
    • Morady F. Radio-frequency ablation as treatment for cardiac arrhythmias. N Engl J Med 340 (1999) 534-544
    • (1999) N Engl J Med , vol.340 , pp. 534-544
    • Morady, F.1
  • 2
    • 4544384291 scopus 로고    scopus 로고
    • Catheter ablation for cardiac arrhythmias
    • Wellens H.J. Catheter ablation for cardiac arrhythmias. N Engl J Med 351 (2004) 1172-1174
    • (2004) N Engl J Med , vol.351 , pp. 1172-1174
    • Wellens, H.J.1
  • 3
    • 0036221985 scopus 로고    scopus 로고
    • Ablation therapy for atrial fibrillation (AF): past, present and future
    • Jais P., Weerasooriya R., Shah D.C., et al. Ablation therapy for atrial fibrillation (AF): past, present and future. Cardiovasc Res 54 (2002) 337-346
    • (2002) Cardiovasc Res , vol.54 , pp. 337-346
    • Jais, P.1    Weerasooriya, R.2    Shah, D.C.3
  • 4
    • 0033517860 scopus 로고    scopus 로고
    • Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation
    • Chen S.A., Hsieh M.H., Tai C.T., et al. Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation. Circulation 100 (1999) 1879-1886
    • (1999) Circulation , vol.100 , pp. 1879-1886
    • Chen, S.A.1    Hsieh, M.H.2    Tai, C.T.3
  • 5
    • 0037036848 scopus 로고    scopus 로고
    • Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation: impact of different catheter technologies
    • Marrouche N.F., Dresing T., Cole C., et al. Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation: impact of different catheter technologies. J Am Coll Cardiol 40 (2002) 464-474
    • (2002) J Am Coll Cardiol , vol.40 , pp. 464-474
    • Marrouche, N.F.1    Dresing, T.2    Cole, C.3
  • 6
    • 0035923561 scopus 로고    scopus 로고
    • Atrial electroanatomical remodeling after circumferential radiofrequency pulmonary vein ablation: efficacy of an anatomic approach in a large cohort of patients with atrial fibrillation
    • Pappone C., Oreto G., Rosanio S., et al. Atrial electroanatomical remodeling after circumferential radiofrequency pulmonary vein ablation: efficacy of an anatomic approach in a large cohort of patients with atrial fibrillation. Circulation 104 (2001) 2539-2544
    • (2001) Circulation , vol.104 , pp. 2539-2544
    • Pappone, C.1    Oreto, G.2    Rosanio, S.3
  • 7
    • 2542488122 scopus 로고    scopus 로고
    • A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate
    • Nademanee K., McKenzie J., Kosar E., et al. A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate. J Am Coll Cardiol 43 (2004) 2044-2053
    • (2004) J Am Coll Cardiol , vol.43 , pp. 2044-2053
    • Nademanee, K.1    McKenzie, J.2    Kosar, E.3
  • 8
    • 33748741361 scopus 로고    scopus 로고
    • Novel robotic catheter remote control system: feasibility and safety of transseptal puncture and endocardial catheter navigation
    • Saliba, Cummings J.e., Oh S., et al. Novel robotic catheter remote control system: feasibility and safety of transseptal puncture and endocardial catheter navigation. J Cardiovasc Electrophysiol 17 (2006) 1102-1105
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 1102-1105
    • Saliba1    Cummings, J.e.2    Oh, S.3
  • 9
    • 23944449664 scopus 로고    scopus 로고
    • Early experience with a computerized robotically controlled catheter system
    • Al-Ahmad A., Grossman J.D., and Wang P.J. Early experience with a computerized robotically controlled catheter system. J Interv Card Electrophysiol 12 (2005) 199-202
    • (2005) J Interv Card Electrophysiol , vol.12 , pp. 199-202
    • Al-Ahmad, A.1    Grossman, J.D.2    Wang, P.J.3
  • 10
    • 0344873703 scopus 로고    scopus 로고
    • Magnetic guidance system for cardiac electrophysiology: a prospective trial of safety and efficacy in humans
    • Faddis M.N., Chen J., Osborn J., Talcott M., Cain M.E., and Lindsay B.D. Magnetic guidance system for cardiac electrophysiology: a prospective trial of safety and efficacy in humans. J Am Coll Cardiol 42 (2003) 1952-1958
    • (2003) J Am Coll Cardiol , vol.42 , pp. 1952-1958
    • Faddis, M.N.1    Chen, J.2    Osborn, J.3    Talcott, M.4    Cain, M.E.5    Lindsay, B.D.6
  • 11
    • 12144289547 scopus 로고    scopus 로고
    • Initial experience with remote catheter ablation using a novel magnetic navigation system: magnetic remote catheter ablation
    • Ernst S., Ouyang F., Linder C., et al. Initial experience with remote catheter ablation using a novel magnetic navigation system: magnetic remote catheter ablation. Circulation 109 (2004) 1472-1475
    • (2004) Circulation , vol.109 , pp. 1472-1475
    • Ernst, S.1    Ouyang, F.2    Linder, C.3
  • 12
    • 33645409828 scopus 로고    scopus 로고
    • Robotic magnetic navigation for atrial fibrillation ablation
    • Pappone C., Vicedomini G., Manguso F., et al. Robotic magnetic navigation for atrial fibrillation ablation. J Am Coll Cardiol 47 (2006) 1390-1400
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1390-1400
    • Pappone, C.1    Vicedomini, G.2    Manguso, F.3
  • 13
    • 33947732778 scopus 로고    scopus 로고
    • Remote magnetic navigation to guide endocardial and epicardial catheter mapping of scar-related ventricular tachycardia
    • Aryana A., d'Avila A., Heist E.K., et al. Remote magnetic navigation to guide endocardial and epicardial catheter mapping of scar-related ventricular tachycardia. Circulation 115 (2007) 1191-1200
    • (2007) Circulation , vol.115 , pp. 1191-1200
    • Aryana, A.1    d'Avila, A.2    Heist, E.K.3
  • 14
    • 34547952200 scopus 로고    scopus 로고
    • Remote magnetic navigation: human experience in pulmonary vein ablation
    • Di Biase L., Fahmy T.S., Patel D., et al. Remote magnetic navigation: human experience in pulmonary vein ablation. J Am Coll Cardiol 50 (2007) 868-874
    • (2007) J Am Coll Cardiol , vol.50 , pp. 868-874
    • Di Biase, L.1    Fahmy, T.S.2    Patel, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.