메뉴 건너뛰기




Volumn 71, Issue , 2014, Pages 414-424

Performance comparison between R22 and R744 solar-geothermal hybrid heat pumps according to heat source conditions

Author keywords

Carbon dioxide(R744); COP; Geothermal; Heat pump; Solar

Indexed keywords

CARBON DIOXIDE; COLLECTOR EFFICIENCY; EVAPORATORS; GEOTHERMAL ENERGY; PUMPS; TEMPERATURE;

EID: 84902438462     PISSN: 09601481     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.renene.2014.05.057     Document Type: Article
Times cited : (32)

References (34)
  • 1
    • 42749092279 scopus 로고    scopus 로고
    • Performance of evaporator-collector and air collector in solar assisted heat pump dryer
    • Hawlader M.N.A., Rahman S.M.A., Jahangeer K.A. Performance of evaporator-collector and air collector in solar assisted heat pump dryer. Energy Convers Manag 2008, 49:1612-1619.
    • (2008) Energy Convers Manag , vol.49 , pp. 1612-1619
    • Hawlader, M.N.A.1    Rahman, S.M.A.2    Jahangeer, K.A.3
  • 2
    • 77953324430 scopus 로고    scopus 로고
    • Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings
    • Kjellsson E., Hellstrom G., Perers B. Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings. Energy 2010, 35(6):2667-2673.
    • (2010) Energy , vol.35 , Issue.6 , pp. 2667-2673
    • Kjellsson, E.1    Hellstrom, G.2    Perers, B.3
  • 3
    • 0141849032 scopus 로고    scopus 로고
    • Investigation of thermal performance of a ground coupled heat pump system with a cylindrical energy storage tank
    • Yumrutas R., Kunduz M., Ayhan T. Investigation of thermal performance of a ground coupled heat pump system with a cylindrical energy storage tank. Int J Energy Res 2003, 27(11):1051-1066.
    • (2003) Int J Energy Res , vol.27 , Issue.11 , pp. 1051-1066
    • Yumrutas, R.1    Kunduz, M.2    Ayhan, T.3
  • 4
    • 79961021007 scopus 로고    scopus 로고
    • Experimental studies on a ground coupled heat pump with solar thermal collectors for space heating
    • Xi C., Hongxing Y., Lin L., Jinggang W., Wei L. Experimental studies on a ground coupled heat pump with solar thermal collectors for space heating. Energy 2011, 36(8):5292-5300.
    • (2011) Energy , vol.36 , Issue.8 , pp. 5292-5300
    • Xi, C.1    Hongxing, Y.2    Lin, L.3    Jinggang, W.4    Wei, L.5
  • 5
    • 77956176398 scopus 로고    scopus 로고
    • Experimental study of a solar-assisted ground-coupled heat pump system with solar seasonal thermal storage in severe cold areas
    • Wang X., Zheng M., Zhang W., Zhang S., Yang T. Experimental study of a solar-assisted ground-coupled heat pump system with solar seasonal thermal storage in severe cold areas. Energy Build 2010, 42(11):2104-2110.
    • (2010) Energy Build , vol.42 , Issue.11 , pp. 2104-2110
    • Wang, X.1    Zheng, M.2    Zhang, W.3    Zhang, S.4    Yang, T.5
  • 6
    • 0026169069 scopus 로고    scopus 로고
    • Second-law analysis of solar-assisted heat pump
    • Chaturvedi S.K., Mohieldin T.O., Chen D.T. Second-law analysis of solar-assisted heat pump. Energy 1999, 16(6):941-949.
    • (1999) Energy , vol.16 , Issue.6 , pp. 941-949
    • Chaturvedi, S.K.1    Mohieldin, T.O.2    Chen, D.T.3
  • 7
    • 0033015109 scopus 로고    scopus 로고
    • Thermodynamic analysis of two-component, two-phase flow in solar collectors with application to a direct-expansion solar-assisted heat pump
    • Aziz W., Chaturvedi S.K., Kheireddine A. Thermodynamic analysis of two-component, two-phase flow in solar collectors with application to a direct-expansion solar-assisted heat pump. Energy 1999, 24(3):247-259.
    • (1999) Energy , vol.24 , Issue.3 , pp. 247-259
    • Aziz, W.1    Chaturvedi, S.K.2    Kheireddine, A.3
  • 8
    • 84857036848 scopus 로고    scopus 로고
    • Performance prediction of a hybrid solar-ground heat pump system
    • Wang E., Fung A.S., Qi C., Leong W.H. Performance prediction of a hybrid solar-ground heat pump system. Energy Build 2012, 47(68):600-611.
    • (2012) Energy Build , vol.47 , Issue.68 , pp. 600-611
    • Wang, E.1    Fung, A.S.2    Qi, C.3    Leong, W.H.4
  • 9
    • 84865420255 scopus 로고    scopus 로고
    • Theoretical model and experimental validation of a direct-expansion solar assisted heat pump for domestic hot water applications
    • Moreno-Rodriguez A., Gonzalez-Gil A., Izquiredo M., Garcai-Hernando N. Theoretical model and experimental validation of a direct-expansion solar assisted heat pump for domestic hot water applications. Energy 2012, 45(1):704-715.
    • (2012) Energy , vol.45 , Issue.1 , pp. 704-715
    • Moreno-Rodriguez, A.1    Gonzalez-Gil, A.2    Izquiredo, M.3    Garcai-Hernando, N.4
  • 10
    • 84902529061 scopus 로고    scopus 로고
    • Using a heat pump as an alternative to support solar collector for water heating in Brazil
    • Roberts V.D.M.R., Raphael O.N., Luiz M., Ricardo N.N.K. Using a heat pump as an alternative to support solar collector for water heating in Brazil. Int J Air-Conditioning Refrig 2012, 20(3):1250013.
    • (2012) Int J Air-Conditioning Refrig , vol.20 , Issue.3 , pp. 1250013
    • Roberts, V.D.M.R.1    Raphael, O.N.2    Luiz, M.3    Ricardo, N.N.K.4
  • 11
  • 12
    • 84856686171 scopus 로고    scopus 로고
    • Energy analysis and modeling of a solar assisted house heating system with a heat pump and an underground energy storage tank
    • Yumrutas R., Unsal M. Energy analysis and modeling of a solar assisted house heating system with a heat pump and an underground energy storage tank. Sol Energy 2012, 86(3):983-993.
    • (2012) Sol Energy , vol.86 , Issue.3 , pp. 983-993
    • Yumrutas, R.1    Unsal, M.2
  • 14
    • 84902443852 scopus 로고    scopus 로고
    • Korea Institute of Energy Research, Double Vacuum Tube Solar Collector (T/259/1800-20U), Certificate of Analysis.
    • Korea Institute of Energy Research, Double Vacuum Tube Solar Collector (T/259/1800-20U), Certificate of Analysis.
  • 15
    • 0031343176 scopus 로고    scopus 로고
    • The relationship of optimum heat exchanger allocation and minimum entropy generation for refrigeration cycle
    • Klein S.A., Reinld D.T. The relationship of optimum heat exchanger allocation and minimum entropy generation for refrigeration cycle. Proc ASME Adv 2000, 37:87-94.
    • (2000) Proc ASME Adv , vol.37 , pp. 87-94
    • Klein, S.A.1    Reinld, D.T.2
  • 16
    • 84902497645 scopus 로고    scopus 로고
    • Influence of the superheat associated to a semihermetic compressor of a transcritical region
    • Sanchez D., Torrella E., Cabello R., Llopic R. Influence of the superheat associated to a semihermetic compressor of a transcritical region. Int J Refrig 2003, 26(8):857-864.
    • (2003) Int J Refrig , vol.26 , Issue.8 , pp. 857-864
    • Sanchez, D.1    Torrella, E.2    Cabello, R.3    Llopic, R.4
  • 17
    • 0016441486 scopus 로고
    • New equation for heat and mass transfer in turbulent pipe and channel flow
    • Gnielinski V, New equation for heat and mass transfer in turbulent pipe and channel flow. Nasa-STI/Recon Technical Report A 1975;41(1):8-16.
    • (1975) Nasa-STI/Recon Technical Report , vol.41 A , Issue.1 , pp. 8-16
    • Gnielinski, V.1
  • 18
    • 0017769439 scopus 로고
    • Friction-factor equation spans all fluid flow regimes
    • Churchill S.W. Friction-factor equation spans all fluid flow regimes. Chem Eng 1977, 7:91-92.
    • (1977) Chem Eng , vol.7 , pp. 91-92
    • Churchill, S.W.1
  • 21
    • 0141882868 scopus 로고    scopus 로고
    • Heat transfer and pressure drop characteristics during the in-tube cooling process of carbon dioxide in the supercritical region
    • Yoon S.H., Kim J.H., Hwang Y.H., Kim M.S., Min K., Kim Y. Heat transfer and pressure drop characteristics during the in-tube cooling process of carbon dioxide in the supercritical region. Int J Refrig 2003, 26(8):857-864.
    • (2003) Int J Refrig , vol.26 , Issue.8 , pp. 857-864
    • Yoon, S.H.1    Kim, J.H.2    Hwang, Y.H.3    Kim, M.S.4    Min, K.5    Kim, Y.6
  • 22
    • 0037933269 scopus 로고    scopus 로고
    • Condensation in horizontal tubes, part 2: new heat transfer model based on flow regimes
    • Thome J.R., El Hajal J., Cavallini A. Condensation in horizontal tubes, part 2: new heat transfer model based on flow regimes. Int J Heat Mass Transf 2003, 46(18):3365-3387.
    • (2003) Int J Heat Mass Transf , vol.46 , Issue.18 , pp. 3365-3387
    • Thome, J.R.1    El Hajal, J.2    Cavallini, A.3
  • 23
    • 0347131245 scopus 로고    scopus 로고
    • Characteristics of evaporative heat transfer and pressure drop of carbon dioxide and correlation development
    • Yoon S.H., Cho E.S., Hwang Y.W., Kim M.S., Min K., Kim Y. Characteristics of evaporative heat transfer and pressure drop of carbon dioxide and correlation development. Int J Refrig 2004, 27(2):111-119.
    • (2004) Int J Refrig , vol.27 , Issue.2 , pp. 111-119
    • Yoon, S.H.1    Cho, E.S.2    Hwang, Y.W.3    Kim, M.S.4    Min, K.5    Kim, Y.6
  • 24
    • 0021783470 scopus 로고
    • Heat transfer in automobile radiators of the tubular type
    • Dittus F.W., Boelter L.M.K. Heat transfer in automobile radiators of the tubular type. Int Commun Heat Mass Transf 1985, 12(1):3-22.
    • (1985) Int Commun Heat Mass Transf , vol.12 , Issue.1 , pp. 3-22
    • Dittus, F.W.1    Boelter, L.M.K.2
  • 26
    • 0033309492 scopus 로고    scopus 로고
    • An investigation of the airside performance of the slit fin-and-tube heat exchangers
    • Wang C.C., Tao W.H., Chang C.J. An investigation of the airside performance of the slit fin-and-tube heat exchangers. Int J Refrig 1999, 22(8):596-603.
    • (1999) Int J Refrig , vol.22 , Issue.8 , pp. 596-603
    • Wang, C.C.1    Tao, W.H.2    Chang, C.J.3
  • 27
    • 0024302296 scopus 로고
    • Experimental investigation of thermal conductance of finned tube contracts
    • Sheffield J., Wood R., Sauer J. Experimental investigation of thermal conductance of finned tube contracts. Exp Therm Fluid Sci 1989, 2(1):107-121.
    • (1989) Exp Therm Fluid Sci , vol.2 , Issue.1 , pp. 107-121
    • Sheffield, J.1    Wood, R.2    Sauer, J.3
  • 29
    • 36549004972 scopus 로고    scopus 로고
    • Mass flow characteristics and empirical modeling of R22 and R410A flowing through electronic expansion valve
    • Park C.S., Cho H.H., Lee Y.T., Kim Y.C. Mass flow characteristics and empirical modeling of R22 and R410A flowing through electronic expansion valve. Int J Refrig 2007, 30(8):1401-1407.
    • (2007) Int J Refrig , vol.30 , Issue.8 , pp. 1401-1407
    • Park, C.S.1    Cho, H.H.2    Lee, Y.T.3    Kim, Y.C.4
  • 31
    • 84902441345 scopus 로고    scopus 로고
    • Investigation on the Thermal performance of evacuated heat pipe solar collector by comparing between simulation and Experiment results
    • Tong Y.J., Cho H.H. Investigation on the Thermal performance of evacuated heat pipe solar collector by comparing between simulation and Experiment results. Proceedings of the SAREK 2013 Summer Annual Conference 2013, 919-922.
    • (2013) Proceedings of the SAREK 2013 Summer Annual Conference , pp. 919-922
    • Tong, Y.J.1    Cho, H.H.2
  • 32
    • 84902477207 scopus 로고    scopus 로고
    • Performance evaluation of R22 and R407C in a vapour compression plant with reciprocating compressor
    • Aprea C., Greco A. Performance evaluation of R22 and R407C in a vapour compression plant with reciprocating compressor. Appl Therm Eng 2003, 24:287-499.
    • (2003) Appl Therm Eng , vol.24 , pp. 287-499
    • Aprea, C.1    Greco, A.2
  • 34
    • 79960744379 scopus 로고    scopus 로고
    • Study on the performance of a solar assisted air source heat pump system for building heating
    • Liang C.H., Zhang S.X., Li W.X., Zhu X. Study on the performance of a solar assisted air source heat pump system for building heating. Energy Build 2011, 43:2188-2196.
    • (2011) Energy Build , vol.43 , pp. 2188-2196
    • Liang, C.H.1    Zhang, S.X.2    Li, W.X.3    Zhu, X.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.