-
2
-
-
0036533371
-
The effects of improper refrigerant charge on the performance of a heat pump with an electronic expansion valve and capillary tube
-
Choi J.M., and Kim Y.C. The effects of improper refrigerant charge on the performance of a heat pump with an electronic expansion valve and capillary tube. Energy 27 (2002) 391-404
-
(2002)
Energy
, vol.27
, pp. 391-404
-
-
Choi, J.M.1
Kim, Y.C.2
-
3
-
-
0008537833
-
Novel electronic high reliability valve principle for control of direct expansion
-
IIR/IIF, Sydney (Paper 445)
-
Lars B.K. Novel electronic high reliability valve principle for control of direct expansion. The 20th International Congress of Refrigeration (1999), IIR/IIF, Sydney (Paper 445)
-
(1999)
The 20th International Congress of Refrigeration
-
-
Lars, B.K.1
-
4
-
-
74149090895
-
Study of fuzzy control of the electronic valve in the air-conditioner with inverter
-
IIR/IIF, Sydney (Paper 558)
-
Zhou X., Xia J., Jin X., and Zhou Z. Study of fuzzy control of the electronic valve in the air-conditioner with inverter. The 20th International Congress of Refrigeration (1999), IIR/IIF, Sydney (Paper 558)
-
(1999)
The 20th International Congress of Refrigeration
-
-
Zhou, X.1
Xia, J.2
Jin, X.3
Zhou, Z.4
-
5
-
-
0033148246
-
An experimental analysis of adiabatic capillary tubes
-
Melo C., Ferreira R.T.S., Neto C.B., Goncalves J.M., and Mezavila M.M. An experimental analysis of adiabatic capillary tubes. Appl. Therm. Eng. 19 (1999) 669-694
-
(1999)
Appl. Therm. Eng.
, vol.19
, pp. 669-694
-
-
Melo, C.1
Ferreira, R.T.S.2
Neto, C.B.3
Goncalves, J.M.4
Mezavila, M.M.5
-
6
-
-
0030312032
-
A theoretical model for predicting adiabatic capillary tube performance with alternative refrigerants
-
Bittle R.R., and Pate M.B. A theoretical model for predicting adiabatic capillary tube performance with alternative refrigerants. ASHRAE Trans. 102 2 (1996) 52-64
-
(1996)
ASHRAE Trans.
, vol.102
, Issue.2
, pp. 52-64
-
-
Bittle, R.R.1
Pate, M.B.2
-
7
-
-
0005375717
-
Theory and use of the capillary tube expansion device. Part II, non-adiabatic flow
-
Bolstad N.M., and Jordan R.C. Theory and use of the capillary tube expansion device. Part II, non-adiabatic flow. Refrigerating Eng. 57 6 (1949) 572-583
-
(1949)
Refrigerating Eng.
, vol.57
, Issue.6
, pp. 572-583
-
-
Bolstad, N.M.1
Jordan, R.C.2
-
8
-
-
0025725444
-
Modeling of steady flow of R-22 through capillary tubes
-
Kuehl S.J., and Goldschmidt V.W. Modeling of steady flow of R-22 through capillary tubes. ASHRAE Trans. 97 1 (1991) 139-148
-
(1991)
ASHRAE Trans.
, vol.97
, Issue.1
, pp. 139-148
-
-
Kuehl, S.J.1
Goldschmidt, V.W.2
-
9
-
-
0000192077
-
A correlation for metastable flow of refrigerant 12 through capillary tubes
-
Chen Z.H., Li R.Y., Lin S., and Chen Z.Y. A correlation for metastable flow of refrigerant 12 through capillary tubes. ASHRAE Trans. 96 1 (1990) 550-554
-
(1990)
ASHRAE Trans.
, vol.96
, Issue.1
, pp. 550-554
-
-
Chen, Z.H.1
Li, R.Y.2
Lin, S.3
Chen, Z.Y.4
-
10
-
-
36549034924
-
-
D.A. Wolf, R.R. Bittle, M.B. Pate, Adiabatic capillary tube performance with alternative refrigerants, ASHRAE RP-762, 1995.
-
-
-
-
11
-
-
0036679905
-
Experimental investigation of the performance of R22, R407C, and R410A in several capillary tubes for air-conditioner
-
Kim S.G., Kim M.S., and Ro S.T. Experimental investigation of the performance of R22, R407C, and R410A in several capillary tubes for air-conditioner. Int. J. Refrigeration 25 (2002) 521-531
-
(2002)
Int. J. Refrigeration
, vol.25
, pp. 521-531
-
-
Kim, S.G.1
Kim, M.S.2
Ro, S.T.3
-
12
-
-
0001194254
-
Experimentation, analysis, and correlation of R-22 flow through short tube restrictors
-
Aaron D.A., and Domanski P.A. Experimentation, analysis, and correlation of R-22 flow through short tube restrictors. ASHRAE Trans. 96 1 (1990) 729-742
-
(1990)
ASHRAE Trans.
, vol.96
, Issue.1
, pp. 729-742
-
-
Aaron, D.A.1
Domanski, P.A.2
-
13
-
-
1642634477
-
A generalized correlation for two-phase flow of alternative refrigerants through short tube orifices
-
Choi J.M., Chung J.T., and Kim Y.C. A generalized correlation for two-phase flow of alternative refrigerants through short tube orifices. Int. J. Refrigeration 27 4 (2004) 393-400
-
(2004)
Int. J. Refrigeration
, vol.27
, Issue.4
, pp. 393-400
-
-
Choi, J.M.1
Chung, J.T.2
Kim, Y.C.3
-
14
-
-
19944406149
-
Experimental research on refrigerant mass flow coefficient of electronic expansion valve
-
Shanwei M., Chuan Z., Jiangping C., and Zhiujiu C. Experimental research on refrigerant mass flow coefficient of electronic expansion valve. Appl. Therm. Eng. 25 (2005) 2351-2366
-
(2005)
Appl. Therm. Eng.
, vol.25
, pp. 2351-2366
-
-
Shanwei, M.1
Chuan, Z.2
Jiangping, C.3
Zhiujiu, C.4
-
15
-
-
0035393928
-
Flow of refrigerant 134a through orifice tubes
-
Singh G.M., Hrnjak P.S., and Bullard C.W. Flow of refrigerant 134a through orifice tubes. HVAC&R Research 7 3 (2001) 245-262
-
(2001)
HVAC&R Research
, vol.7
, Issue.3
, pp. 245-262
-
-
Singh, G.M.1
Hrnjak, P.S.2
Bullard, C.W.3
-
16
-
-
18144381070
-
Mass flow rate of R-410A through short tubes working near the critical point
-
Kim Y.C., Payne V., Choi J.M., and Domanski P.A. Mass flow rate of R-410A through short tubes working near the critical point. Int. J. Refrigeration 28 (2005) 547-553
-
(2005)
Int. J. Refrigeration
, vol.28
, pp. 547-553
-
-
Kim, Y.C.1
Payne, V.2
Choi, J.M.3
Domanski, P.A.4
-
17
-
-
36549030890
-
-
M. McLinden, S.A. Klein, E.W. Lemmon, A.P. Peskin, NIST Thermodynamic and Transport Properties of Refrigerant and Refrigerant Mixtures (REFPROP), 1998 (version 6.01).
-
-
-
|