메뉴 건너뛰기




Volumn 12, Issue 2, 2014, Pages 246-258

Evaluation of the alamarblue assay for adherent cell irradiation experiments

Author keywords

96 well plate; AlamarBlue; Dose response; Radiation

Indexed keywords

ADHERENT CELL; ARTICLE; CANCER CELL LINE; CELL PROLIFERATION; CELL SURVIVAL; CELL VIABILITY; CONTROLLED STUDY; CULTURE MEDIUM; FLUORESCENCE ANALYSIS; IONIZING RADIATION; RADIATION DOSE; RADIATION RESPONSE; RADIOSENSITIZATION; RELATIVE FLUORESCENCE UNIT; RESAZURIN ASSAY;

EID: 84902381376     PISSN: None     EISSN: 15593258     Source Type: Journal    
DOI: 10.2203/dose-response.13-024.Koukourakis     Document Type: Article
Times cited : (54)

References (7)
  • 1
    • 84873709288 scopus 로고    scopus 로고
    • Establishment and validation of a method for multi-dose irradiation of cells in 96-well microplates
    • Abatzoglou I, Zois CE, Pouliliou S, and Koukourakis MI. 2013. Establishment and validation of a method for multi-dose irradiation of cells in 96-well microplates. Biochem Biophys Res Commun 431:456-459
    • (2013) Biochem Biophys Res Commun , vol.431 , pp. 456-459
    • Abatzoglou, I.1    Zois, C.E.2    Pouliliou, S.3    Koukourakis, M.I.4
  • 3
    • 16344375855 scopus 로고    scopus 로고
    • Differential cyclooxygenase-2 enzyme expression in radiosensitive versus radioresistant glioblastoma multiforme cell lines
    • Karim A, McCarthy K, Jawahar A, Smith D, Willis B, and Nanda A. 2005. Differential cyclooxygenase-2 enzyme expression in radiosensitive versus radioresistant glioblastoma multiforme cell lines. Anticancer Res 25:675-679
    • (2005) Anticancer Res , vol.25 , pp. 675-679
    • Karim, A.1    McCarthy, K.2    Jawahar, A.3    Smith, D.4    Willis, B.5    Nanda, A.6
  • 4
    • 0030910012 scopus 로고    scopus 로고
    • Assessment of the Alamar Blue assay for cellular growth and viability in vitro
    • Nakayama GR, Caton MC, Nova MP, and Parandoosh Z. 1997. Assessment of the Alamar Blue assay for cellular growth and viability in vitro. J Immunol Methods. 204:205-208
    • (1997) J Immunol Methods. , vol.204 , pp. 205-208
    • Nakayama, G.R.1    Caton, M.C.2    Nova, M.P.3    Parandoosh, Z.4
  • 5
    • 0031852098 scopus 로고    scopus 로고
    • A novel one-step, highly sensitive fluorometric assay to evaluate cell-mediated cytotoxicity
    • Nociari MM, Shalev A, Benias P, and Russo C. 1998. A novel one-step, highly sensitive fluorometric assay to evaluate cell-mediated cytotoxicity. J Immunol Methods 213:157-167
    • (1998) J Immunol Methods , vol.213 , pp. 157-167
    • Nociari, M.M.1    Shalev, A.2    Benias, P.3    Russo, C.4
  • 6
    • 0033856957 scopus 로고    scopus 로고
    • Investigation of the Alamar Blue (resazurin) fluorescent dye for the assessment of mammalian cell cytotoxicity
    • Protocols & Applications Guide, rev. 3/11
    • O'Brien J, Wilson I, Orton T, and Pognan F. 2000. Investigation of the Alamar Blue (resazurin) fluorescent dye for the assessment of mammalian cell cytotoxicity. Eur J Biochem 267:5421-5426 Protocols & Applications Guide. www.promega.com. rev. 3/11.
    • (2000) Eur J Biochem , vol.267 , pp. 5421-5426
    • O'Brien, J.1    Wilson, I.2    Orton, T.3    Pognan, F.4
  • 7
    • 0027249667 scopus 로고
    • A new fluorometric assay for cytotoxicity measurements in-vitro
    • Page B, Page M, and Noel C. 1993. A new fluorometric assay for cytotoxicity measurements in-vitro. Int J Oncol 3:473-476
    • (1993) Int J Oncol , vol.3 , pp. 473-476
    • Page, B.1    Page, M.2    Noel, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.