Accuracy of diffusion-weighted (DW) MRI with background signal suppression (MR-DWIBS) in diagnosis of mediastinal lymph node metastasis of nonsmall-cell lung cancer (NSCLC)

Author keywords

diffusion magnetic resonance imaging; lung neoplasms; lymphatic metastasis; magnetic resonance imaging; neoplasm metastasis

Indexed keywords

ADULT; AGED; ARTICLE; CANCER PATIENT; CLINICAL ARTICLE; CLINICAL EFFECTIVENESS; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DIFFUSION COEFFICIENT; DIFFUSION WEIGHTED IMAGING; DIFFUSION WEIGHTED MAGNETIC RESONANCE IMAGING WITH BACKGROUND SIGNAL SUPPRESSION; EVALUATION STUDY; FEMALE; HISTOPATHOLOGY; HUMAN; HUMAN TISSUE; LUNG NON SMALL CELL CANCER; LYMPH NODE METASTASIS; LYMPHADENOPATHY; MALE; MEDIASTINUM LYMPH NODE; MEDIASTINUM LYMPH NODE METASTASIS; MEDIASTINUM METASTASIS; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PREDICTIVE VALUE; PRIORITY JOURNAL; PROSPECTIVE STUDY; SENSITIVITY AND SPECIFICITY; ALGORITHM; ARTIFACT; COMPUTER ASSISTED DIAGNOSIS; IMAGE ENHANCEMENT; IMAGE SUBTRACTION; LUNG TUMOR; LYMPH NODE; MIDDLE AGED; NON SMALL CELL LUNG CANCER; OBSERVER VARIATION; PATHOLOGY; PROCEDURES; REPRODUCIBILITY; SECONDARY; SIGNAL NOISE RATIO;

EID: 84902373600     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.24343     Document Type: Article
Times cited : (22)

References (23)
  • 1
    • 21244462759 scopus 로고    scopus 로고
    • Prognostic factors in surgically resected N2 non-small cell lung cancer: The importance of patterns of mediastinal lymph nodes metastases
    • Casali C, Stefani A, Natali P, Rossi G, Morandi U,. Prognostic factors in surgically resected N2 non-small cell lung cancer: the importance of patterns of mediastinal lymph nodes metastases. Eur J Cardiothorac Surg 2005; 28: 33-38.
    • (2005) Eur J Cardiothorac Surg , vol.28 , pp. 33-38
    • Casali, C.1    Stefani, A.2    Natali, P.3    Rossi, G.4    Morandi, U.5
  • 2
    • 77956669890 scopus 로고    scopus 로고
    • Prognostic evaluation of nodal staging based on the new IASLC lymph node map for lung cancer
    • Takamochi K, Oh S, Suzuki K,. Prognostic evaluation of nodal staging based on the new IASLC lymph node map for lung cancer. Thorac Cardiovasc Surg 2010; 58: 345-349.
    • (2010) Thorac Cardiovasc Surg , vol.58 , pp. 345-349
    • Takamochi, K.1    Oh, S.2    Suzuki, K.3
  • 4
    • 4143102533 scopus 로고    scopus 로고
    • Chest CT and serum vascular endothelial growth factor-C level to diagnose lymph node metastasis in patients with primary non-small cell lung cancer
    • Tamura M, Oda M, Tsunezuka Y, et al. Chest CT and serum vascular endothelial growth factor-C level to diagnose lymph node metastasis in patients with primary non-small cell lung cancer. Chest 2004; 126: 342-346.
    • (2004) Chest , vol.126 , pp. 342-346
    • Tamura, M.1    Oda, M.2    Tsunezuka, Y.3
  • 5
    • 0037331542 scopus 로고    scopus 로고
    • Lymph node size and metastatic infiltration in non-small cell lung cancer
    • Prenzel KL, Monig SP, Sinning JM, et al. Lymph node size and metastatic infiltration in non-small cell lung cancer. Chest 2003; 123: 463-467.
    • (2003) Chest , vol.123 , pp. 463-467
    • Prenzel, K.L.1    Monig, S.P.2    Sinning, J.M.3
  • 6
    • 34249874331 scopus 로고    scopus 로고
    • Diffusion-weighted MRI in the body: Applications and challenges in oncology
    • Koh DM, Collins DJ,. Diffusion-weighted MRI in the body: applications and challenges in oncology. AJR Am J Roentgenol 2007; 188: 1622-1635.
    • (2007) AJR Am J Roentgenol , vol.188 , pp. 1622-1635
    • Koh, D.M.1    Collins, D.J.2
  • 7
    • 80052213872 scopus 로고    scopus 로고
    • Whole-body diffusion-weighted imaging: The added value to whole-body MRI at initial diagnosis of lymphoma
    • Gu J, Chan T, Zhang J, Leung AY, Kwong YL, Khong PL,. Whole-body diffusion-weighted imaging: the added value to whole-body MRI at initial diagnosis of lymphoma. AJR Am Roentgenol 2011; 197: W384-391.
    • (2011) AJR Am Roentgenol , vol.197
    • Gu, J.1    Chan, T.2    Zhang, J.3    Leung, A.Y.4    Kwong, Y.L.5    Khong, P.L.6
  • 8
    • 16244366026 scopus 로고
    • Index for rating diagnostic tests
    • Youden WJ,. Index for rating diagnostic tests. Cancer 1950; 3: 32-35.
    • (1950) Cancer , vol.3 , pp. 32-35
    • Youden, W.J.1
  • 9
    • 77950101227 scopus 로고    scopus 로고
    • Biopsy-proved idiopathic pulmonary fibrosis: Spectrum of nondiagnostic thin-section CT diagnoses
    • Sverzellati N, Wells AU, Tomassetti S, et al. Biopsy-proved idiopathic pulmonary fibrosis: spectrum of nondiagnostic thin-section CT diagnoses. Radiology 2010; 254: 957-964.
    • (2010) Radiology , vol.254 , pp. 957-964
    • Sverzellati, N.1    Wells, A.U.2    Tomassetti, S.3
  • 10
    • 9144235607 scopus 로고    scopus 로고
    • A comparative analysis of positron emission tomography and mediastinoscopy in staging non-small cell lung cancer
    • Gonzalez-Stawinski GV, Lemaire A, Merchant F, et al. A comparative analysis of positron emission tomography and mediastinoscopy in staging non-small cell lung cancer. J Thorac Cardiovasc Surg 2003; 126: 1900-1905.
    • (2003) J Thorac Cardiovasc Surg , vol.126 , pp. 1900-1905
    • Gonzalez-Stawinski, G.V.1    Lemaire, A.2    Merchant, F.3
  • 11
    • 38149113595 scopus 로고    scopus 로고
    • Does video-mediastinoscopy improve the results of conventional mediastinoscopy?
    • Leschber G, Sperling D, Klemm W, Merk J,. Does video-mediastinoscopy improve the results of conventional mediastinoscopy? Eur J Cardiothorac Surg 2008; 33: 289-293.
    • (2008) Eur J Cardiothorac Surg , vol.33 , pp. 289-293
    • Leschber, G.1    Sperling, D.2    Klemm, W.3    Merk, J.4
  • 13
    • 80053473214 scopus 로고    scopus 로고
    • Diagnostic accuracy of virtual 18F-FDG PET/CT bronchoscopy for the detection of lymph node metastases in non-small cell lung cancer patients
    • Herbrik M, Treffert J, Geiger B, et al. Diagnostic accuracy of virtual 18F-FDG PET/CT bronchoscopy for the detection of lymph node metastases in non-small cell lung cancer patients. J Nucl Med 2011; 52: 1520-1525.
    • (2011) J Nucl Med , vol.52 , pp. 1520-1525
    • Herbrik, M.1    Treffert, J.2    Geiger, B.3
  • 14
    • 33846489021 scopus 로고    scopus 로고
    • Efficacy of helical dynamic CT versus integrated PET/CT for detection of mediastinal nodal metastasis in non-small cell lung cancer
    • Yi CA, Lee KS, Kim BT, et al. Efficacy of helical dynamic CT versus integrated PET/CT for detection of mediastinal nodal metastasis in non-small cell lung cancer. AJR Am J Roentgenol 2007; 188: 318-325.
    • (2007) AJR Am J Roentgenol , vol.188 , pp. 318-325
    • Yi, C.A.1    Lee, K.S.2    Kim, B.T.3
  • 15
    • 33746042206 scopus 로고    scopus 로고
    • Maximum standard uptake value of mediastinal lymph nodes on integrated FDG-PET-CT predicts pathology in patients with non-small cell lung cancer
    • discussion 422-413
    • Bryant AS, Cerfolio RJ, Klemm KM, Ojha B,. Maximum standard uptake value of mediastinal lymph nodes on integrated FDG-PET-CT predicts pathology in patients with non-small cell lung cancer. Ann Thorac Surg 2006; 82: 417-422; discussion 422-413.
    • (2006) Ann Thorac Surg , vol.82 , pp. 417-422
    • Bryant, A.S.1    Cerfolio, R.J.2    Klemm, K.M.3    Ojha, B.4
  • 16
    • 49149116752 scopus 로고    scopus 로고
    • Can malignant and benign pulmonary nodules be differentiated with diffusion-weighted MRI?
    • Satoh S, Kitazume Y, Ohdama S, Kimula Y, Taura S, Endo Y,. Can malignant and benign pulmonary nodules be differentiated with diffusion-weighted MRI? AJR Am J Roentgenol 2008; 191: 464-470.
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 464-470
    • Satoh, S.1    Kitazume, Y.2    Ohdama, S.3    Kimula, Y.4    Taura, S.5    Endo, Y.6
  • 17
    • 79957786585 scopus 로고    scopus 로고
    • Diffusion-weighted imaging is superior to positron emission tomography in the detection and nodal assessment of lung cancers
    • Usuda K, Zhao XT, Sagawa M, et al. Diffusion-weighted imaging is superior to positron emission tomography in the detection and nodal assessment of lung cancers. Ann Thorac Surg 2011; 91: 1689-1695.
    • (2011) Ann Thorac Surg , vol.91 , pp. 1689-1695
    • Usuda, K.1    Zhao, X.T.2    Sagawa, M.3
  • 18
    • 40949140031 scopus 로고    scopus 로고
    • Diffusion-weighted magnetic resonance imaging can be used in place of positron emission tomography for N staging of non-small cell lung cancer with fewer false-positive results
    • Nomori H, Mori T, Ikeda K, et al. Diffusion-weighted magnetic resonance imaging can be used in place of positron emission tomography for N staging of non-small cell lung cancer with fewer false-positive results. J Thorac Cardiovasc Surg 2008; 135: 816-822.
    • (2008) J Thorac Cardiovasc Surg , vol.135 , pp. 816-822
    • Nomori, H.1    Mori, T.2    Ikeda, K.3
  • 19
    • 4644278852 scopus 로고    scopus 로고
    • Diffusion weighted whole body imaging with background body signal suppression (DWIBS): Technical improvement using free breathing, STIR and high resolution 3D display
    • Takahara T, Imai Y, Yamashita T, Yasuda S, Nasu S, Van Cauteren M,. Diffusion weighted whole body imaging with background body signal suppression (DWIBS): technical improvement using free breathing, STIR and high resolution 3D display. Radiat Med 2004; 22: 275-282.
    • (2004) Radiat Med , vol.22 , pp. 275-282
    • Takahara, T.1    Imai, Y.2    Yamashita, T.3    Yasuda, S.4    Nasu, S.5    Van Cauteren, M.6
  • 20
    • 68049145126 scopus 로고    scopus 로고
    • Detection of bone metastases in non-small cell lung cancer patients: Comparison of whole-body diffusion-weighted imaging (DWI), whole-body MR imaging without and with DWI, whole-body FDG-PET/CT, and bone scintigraphy
    • Takenaka D, Ohno Y, Matsumoto K, et al. Detection of bone metastases in non-small cell lung cancer patients: comparison of whole-body diffusion-weighted imaging (DWI), whole-body MR imaging without and with DWI, whole-body FDG-PET/CT, and bone scintigraphy. J Magn Reson Imaging 2009; 30: 298-308.
    • (2009) J Magn Reson Imaging , vol.30 , pp. 298-308
    • Takenaka, D.1    Ohno, Y.2    Matsumoto, K.3
  • 21
    • 84861624108 scopus 로고    scopus 로고
    • A comparative study: Diffusion weighted whole body imaging with background body signal suppression and hybrid positron emission computed tomography on detecting lesions in oncologic clinics
    • Wang N, Zhang M, Sun T, et al. A comparative study: diffusion weighted whole body imaging with background body signal suppression and hybrid positron emission computed tomography on detecting lesions in oncologic clinics. Eur J Radiol 2012; 81: 1662-1666.
    • (2012) Eur J Radiol , vol.81 , pp. 1662-1666
    • Wang, N.1    Zhang, M.2    Sun, T.3
  • 22
    • 49049115378 scopus 로고    scopus 로고
    • Non-small cell lung cancer: Whole-body MR examination for M-stage assessment - Utility for whole-body diffusion-weighted imaging compared with integrated FDG PET/CT
    • Ohno Y, Koyama H, Onishi Y, et al. Non-small cell lung cancer: whole-body MR examination for M-stage assessment-utility for whole-body diffusion-weighted imaging compared with integrated FDG PET/CT. Radiology 2008; 248: 643-654.
    • (2008) Radiology , vol.248 , pp. 643-654
    • Ohno, Y.1    Koyama, H.2    Onishi, Y.3
  • 23
    • 55749097922 scopus 로고    scopus 로고
    • Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusion-weighted MR imaging of the liver
    • Kwee TC, Takahara T, Koh DM, Nievelstein RA, Luijten PR,. Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusion-weighted MR imaging of the liver. J Magn Reson Imaging 2008; 28: 1141-1148.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 1141-1148
    • Kwee, T.C.1    Takahara, T.2    Koh, D.M.3    Nievelstein, R.A.4    Luijten, P.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.