메뉴 건너뛰기




Volumn 54, Issue 6, 2014, Pages 1486-1492

A new bead-based human platelet antigen antibodies detection assay versus the monoclonal antibody immobilization of platelet antigens assay

Author keywords

[No Author keywords available]

Indexed keywords

AUTOANTIBODY; GLYCOPROTEIN IV ANTIBODY; HLA ANTIBODY; HPA 1B ANTIGEN; HPA 2B ANTIGEN; HPA 3A ANTIGEN; HPA 5B ANTIGEN; IMMOBILIZED ANTIBODY; MONOCLONAL ANTIBODY; THROMBOCYTE ANTIGEN; UNCLASSIFIED DRUG;

EID: 84902274233     PISSN: 00411132     EISSN: 15372995     Source Type: Journal    
DOI: 10.1111/trf.12509     Document Type: Article
Times cited : (37)

References (14)
  • 1
    • 41149169261 scopus 로고    scopus 로고
    • Fetal/neonatal allo-immune thrombocytopenia (FNAIT): Past, present, and future
    • Serrarens-Janssen VM, Semmekrot BA, Novotny VM, etal. Fetal/neonatal allo-immune thrombocytopenia (FNAIT): past, present, and future. Obstet Gynecol Surv 2008; 63: 239-252.
    • (2008) Obstet Gynecol Surv , vol.63 , pp. 239-252
    • Serrarens-Janssen, V.M.1    Semmekrot, B.A.2    Novotny, V.M.3
  • 2
    • 46949103859 scopus 로고    scopus 로고
    • Platelet transfusion refractoriness
    • Hod E, Schwartz J,. Platelet transfusion refractoriness. Br J Haematol 2008; 142: 348-360.
    • (2008) Br J Haematol , vol.142 , pp. 348-360
    • Hod, E.1    Schwartz, J.2
  • 3
    • 33750738083 scopus 로고    scopus 로고
    • Post-transfusion purpura: A challenging diagnosis
    • Shtalrid M, Shvidel L, Vorst E, etal. Post-transfusion purpura: a challenging diagnosis. Isr Med Assoc J 2006; 8: 672-674.
    • (2006) Isr Med Assoc J , vol.8 , pp. 672-674
    • Shtalrid, M.1    Shvidel, L.2    Vorst, E.3
  • 4
    • 0018184678 scopus 로고
    • A simple immunofluorescence test for the detection of platelet antibodies
    • von dem Borne AE, Verheugt FW, Oosterhof F, etal. A simple immunofluorescence test for the detection of platelet antibodies. Br J Haematol 1978; 39: 195-207.
    • (1978) Br J Haematol , vol.39 , pp. 195-207
    • Von Dem Borne, A.E.1    Verheugt, F.W.2    Oosterhof, F.3
  • 5
    • 0023607547 scopus 로고
    • Monoclonal antibody-specific immobilization of platelet antigens (MAIPA). A new tool for the identification of platelet-reactive antibodies
    • Kiefel V, Santoso S, Weisheit M, etal. Monoclonal antibody-specific immobilization of platelet antigens (MAIPA). A new tool for the identification of platelet-reactive antibodies. Blood 1987; 70: 1722-1726.
    • (1987) Blood , vol.70 , pp. 1722-1726
    • Kiefel, V.1    Santoso, S.2    Weisheit, M.3
  • 6
    • 0008068205 scopus 로고
    • Identification of platelet-reactive antibodies using an antigen-capture ELISA
    • Kaye T, Allen DL,. Identification of platelet-reactive antibodies using an antigen-capture ELISA. Transfus Med 1994; 4 (Suppl 1): 49.
    • (1994) Transfus Med , vol.4 , Issue.SUPPL. 1 , pp. 49
    • Kaye, T.1    Allen, D.L.2
  • 7
    • 0008114312 scopus 로고
    • Evaluation of GTI-PAK1 antigen capture ELISA (ACE) for the detection of IgG antibodies to platelet-specific antigens
    • Aster RH,. Evaluation of GTI-PAK1 antigen capture ELISA (ACE) for the detection of IgG antibodies to platelet-specific antigens. Platelets 1994; 5: 222.
    • (1994) Platelets , vol.5 , pp. 222
    • Aster, R.H.1
  • 8
    • 48249136168 scopus 로고    scopus 로고
    • External quality assessment of platelet serology and human platelet antigen genotyping: A 10-year review
    • Porcelijn L, van Beers W, Gratama JW, etal. External quality assessment of platelet serology and human platelet antigen genotyping: a 10-year review. Transfusion 2008; 48: 1699-1706.
    • (2008) Transfusion , vol.48 , pp. 1699-1706
    • Porcelijn, L.1    Van Beers, W.2    Gratama, J.W.3
  • 9
    • 34547104208 scopus 로고    scopus 로고
    • Rapid detection of HPA-1 alloantibodies by platelet antigens immobilized onto microbeads
    • Bakchoul T, Meyer O, Agaylan A, etal. Rapid detection of HPA-1 alloantibodies by platelet antigens immobilized onto microbeads. Transfusion 2007; 47: 1363-1368.
    • (2007) Transfusion , vol.47 , pp. 1363-1368
    • Bakchoul, T.1    Meyer, O.2    Agaylan, A.3
  • 10
    • 79958782042 scopus 로고    scopus 로고
    • Detection of human platelet antigen-1a alloantibodies in cases of fetomaternal alloimmune thrombocytopenia using recombinant β3 integrin fragments coupled to fluorescently labeled beads
    • Chong W, Metcalfe P, Mushens R, etal. Detection of human platelet antigen-1a alloantibodies in cases of fetomaternal alloimmune thrombocytopenia using recombinant β3 integrin fragments coupled to fluorescently labeled beads. Transfusion 2011; 51: 1261-1270.
    • (2011) Transfusion , vol.51 , pp. 1261-1270
    • Chong, W.1    Metcalfe, P.2    Mushens, R.3
  • 11
    • 84876151639 scopus 로고    scopus 로고
    • Development of a single-antigen magnetic bead assay (SAMBA) for the sensitive detection of HPA-1a alloantibodies using tag-engineered recombinant soluble β3 integrin
    • Skaik Y, Battermann A, Hiller O, etal. Development of a single-antigen magnetic bead assay (SAMBA) for the sensitive detection of HPA-1a alloantibodies using tag-engineered recombinant soluble β3 integrin. J Immunol Methods 2013; 391 (1-2): 72-80.
    • (2013) J Immunol Methods , vol.391 , Issue.12 , pp. 72-80
    • Skaik, Y.1    Battermann, A.2    Hiller, O.3
  • 12
    • 62349107355 scopus 로고    scopus 로고
    • Application of bead array technology to simultaneous detection of human leucocyte antigen and human platelet antigen antibodies
    • Fujiwara K, Shimano K, Tanaka H, etal. Application of bead array technology to simultaneous detection of human leucocyte antigen and human platelet antigen antibodies. Vox Sang 2009; 96: 244-251.
    • (2009) Vox Sang , vol.96 , pp. 244-251
    • Fujiwara, K.1    Shimano, K.2    Tanaka, H.3
  • 13
    • 36049041319 scopus 로고    scopus 로고
    • Luminex technology for anti-HLA antibody screening: Evaluation of performance and of impact on laboratory routine
    • Colombo MB, Haworth SE, Poli F, etal. Luminex technology for anti-HLA antibody screening: evaluation of performance and of impact on laboratory routine. Cytometry B Clin Cytom 2007; 72: 465-471.
    • (2007) Cytometry B Clin Cytom , vol.72 , pp. 465-471
    • Colombo, M.B.1    Haworth, S.E.2    Poli, F.3
  • 14
    • 0002594206 scopus 로고
    • A look at HLA antisera in the indirect immunofluorescence technique (IIFT)
    • Kissmeyer-Nielsen F. editor. Copenhagen: Munksgaard;. p.
    • Décary F, Vermeulen A, Engelfriet CP,. A look at HLA antisera in the indirect immunofluorescence technique (IIFT). In:, Kissmeyer-Nielsen F, editor. Histocompatibility testing. Copenhagen: Munksgaard; 1975. p. 380-390.
    • (1975) Histocompatibility Testing , pp. 380-390
    • Décary, F.1    Vermeulen, A.2    Engelfriet, C.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.