메뉴 건너뛰기




Volumn 96, Issue 3, 2009, Pages 244-251

Application of bead array technology to simultaneous detection of human leucocyte antigen and human platelet antigen antibodies

Author keywords

Bead array; Flow cytometric analysis; High throughput; HLA antibodies; HPA antibodies

Indexed keywords

ALPHA2 INTEGRIN; CD36 ANTIGEN; CD61 ANTIGEN; FIBRINOGEN RECEPTOR; GLYCOPROTEIN IB ALPHA; HLA ANTIGEN; HLA ANTIGEN CLASS 1; MONOCLONAL ANTIBODY; THROMBOCYTE ANTIBODY;

EID: 62349107355     PISSN: 00429007     EISSN: 14230410     Source Type: Journal    
DOI: 10.1111/j.1423-0410.2008.01140.x     Document Type: Article
Times cited : (36)

References (17)
  • 2
    • 0020597850 scopus 로고
    • Transfusion-related acute lung injury associated with passive transfer of antileukocyte antibodies
    • Popovsky MA, Abel MD, Moore SB : Transfusion-related acute lung injury associated with passive transfer of antileukocyte antibodies. Am Rev Respir Dis 1983 128 : 185 189
    • (1983) Am Rev Respir Dis , vol.128 , pp. 185-189
    • Popovsky, M.A.1    Abel, M.D.2    Moore, S.B.3
  • 3
    • 0022374475 scopus 로고
    • Diagnostic and pathogenetic considerations in transfusion-related acute lung-injury
    • Popovsky MA, Moore SB : Diagnostic and pathogenetic considerations in transfusion-related acute lung-injury. Transfusion 1985 25 : 573 577
    • (1985) Transfusion , vol.25 , pp. 573-577
    • Popovsky, M.A.1    Moore, S.B.2
  • 4
    • 37049049011 scopus 로고
    • Microdroplet assay of human serum cytotoxins
    • Terasaki PI, Mcclelland JD : Microdroplet assay of human serum cytotoxins. Nature 1964 204 : 998 1000
    • (1964) Nature , vol.204 , pp. 998-1000
    • Terasaki, P.I.1    McClelland, J.D.2
  • 5
    • 0019502574 scopus 로고
    • Detection of platelet antibodies by a newly developed mixed agglutination with platelets
    • Shibata Y, Juji T, Nishizawa Y, Sakamoto H, Ozawa N : Detection of platelet antibodies by a newly developed mixed agglutination with platelets. Vox Sang 1981 41 : 25 31
    • (1981) Vox Sang , vol.41 , pp. 25-31
    • Shibata, Y.1    Juji, T.2    Nishizawa, Y.3    Sakamoto, H.4    Ozawa, N.5
  • 7
    • 0033377751 scopus 로고    scopus 로고
    • Flow cytometric detection of HLA antibodies using a spectrum of microbeads
    • Pei R, Lee J, Chen T, Rojo S, Terasaki PI : Flow cytometric detection of HLA antibodies using a spectrum of microbeads. Hum Immunol 1999 60 : 1293 1302
    • (1999) Hum Immunol , vol.60 , pp. 1293-1302
    • Pei, R.1    Lee, J.2    Chen, T.3    Rojo, S.4    Terasaki, P.I.5
  • 8
    • 33847689387 scopus 로고    scopus 로고
    • HLA class i epitopes: Recognition of binding sites by mAbs or eluted alloantibody confirmed with single recombinant antigens
    • El-Awar N, Lee JH, Tarsitani C, Terasaki PI : HLA class I epitopes: recognition of binding sites by mAbs or eluted alloantibody confirmed with single recombinant antigens. Hum Immunol 2007 68 : 170 180
    • (2007) Hum Immunol , vol.68 , pp. 170-180
    • El-Awar, N.1    Lee, J.H.2    Tarsitani, C.3    Terasaki, P.I.4
  • 9
    • 0023607547 scopus 로고
    • Monoclonal antibody-specific immobilization of platelet antigens (MAIPA). A new tool for the identification of platelet-reactive antibodies
    • Kiefel V, Santoso S, Weisheit M, Mueller-Eckhardt C : Monoclonal antibody-specific immobilization of platelet antigens (MAIPA). A new tool for the identification of platelet-reactive antibodies. Blood 1987 70 : 1722 1726
    • (1987) Blood , vol.70 , pp. 1722-1726
    • Kiefel, V.1    Santoso, S.2    Weisheit, M.3    Mueller-Eckhardt, C.4
  • 11
    • 36249025599 scopus 로고    scopus 로고
    • A modified rapid monoclonal antibody-specific immobilization of platelet antigen assay for the detection of human platelet antigen (HPA) antibodies: A multicentre evaluation
    • Campbell K, Rishi K, Howkins G, Gilby D, Mushens R, Ghevaert C, Metcalfe P, Ouwehand WH, Lucas G : A modified rapid monoclonal antibody-specific immobilization of platelet antigen assay for the detection of human platelet antigen (HPA) antibodies: a multicentre evaluation. Vox Sang 2007 93 : 289 297
    • (2007) Vox Sang , vol.93 , pp. 289-297
    • Campbell, K.1    Rishi, K.2    Howkins, G.3    Gilby, D.4    Mushens, R.5    Ghevaert, C.6    Metcalfe, P.7    Ouwehand, W.H.8    Lucas, G.9
  • 17
    • 0024343552 scopus 로고
    • The flow cytometric crossmatch. Dual-color analysis of T cell and B cell reactivities
    • Bray RA, Lebeck LK, Gebel HM : The flow cytometric crossmatch. Dual-color analysis of T cell and B cell reactivities. Transplantation 1989 48 : 834 840
    • (1989) Transplantation , vol.48 , pp. 834-840
    • Bray, R.A.1    Lebeck, L.K.2    Gebel, H.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.