메뉴 건너뛰기




Volumn 27, Issue 3, 2014, Pages 154-161

Percutaneous lumbar and thoracic pedicle screws: A trauma experience

Author keywords

Minimally invasive spine; Morphometry; Percutaneous pedicle screw; Trauma

Indexed keywords

ADULT; AGED; ARTICLE; BACKACHE; CASE STUDY; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DEVICE PERFORATION; FLUOROSCOPY; FOLLOW UP; FRACTURE HEALING; GUNSHOT INJURY; HUMAN; JAMSHIDI NEEDLE; KIRSCHNER WIRE; MEDICAL DEVICE COMPLICATION; MINIMALLY INVASIVE SURGERY; NEEDLE; PEDICLE SCREW; PERCUTANEOUS LUMBAR PEDICLE SCREW; PRIORITY JOURNAL; PSEUDARTHROSIS; RETROSPECTIVE STUDY; SPINE FUSION; SPINE INJURY; SPINE SURGERY; THORACIC PEDICLE SCREW; TRAFFIC ACCIDENT; VERTEBRA BODY;

EID: 84902131243     PISSN: 15360652     EISSN: 15392465     Source Type: Journal    
DOI: 10.1097/BSD.0b013e318250ec75     Document Type: Article
Times cited : (20)

References (24)
  • 1
    • 13444309087 scopus 로고    scopus 로고
    • Comparison of multifidus muscle atrophy and trunk extension muscle strength: Percutaneous versus open pedicle screw fixation
    • Kim DY, Lee SH, Chung SK, et al. Comparison of multifidus muscle atrophy and trunk extension muscle strength: percutaneous versus open pedicle screw fixation. Spine (Phila Pa 1976). 2005;30:123-129.
    • (2005) Spine (Phila Pa 1976) , vol.30 , pp. 123-129
    • Kim, D.Y.1    Lee, S.H.2    Chung, S.K.3
  • 2
    • 0031424755 scopus 로고    scopus 로고
    • Posterior surgical approach to the lumbar spine and its effect on the multifidus muscle
    • Weber BR, Grob D, Dvorak J, et al. Posterior surgical approach to the lumbar spine and its effect on the multifidus muscle. Spine (Phila Pa 1976). 1997;22:1765-1772.
    • (1997) Spine (Phila Pa 1976) , vol.22 , pp. 1765-1772
    • Weber, B.R.1    Grob, D.2    Dvorak, J.3
  • 3
    • 0029893644 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement in lumbar vertebrae
    • Castro WH, Halm H, Jerosch J, et al. Accuracy of pedicle screw placement in lumbar vertebrae. Spine (Phila Pa 1976). 1996; 21:1320-1324.
    • (1996) Spine (Phila Pa 1976) , vol.21 , pp. 1320-1324
    • Castro, W.H.1    Halm, H.2    Jerosch, J.3
  • 4
    • 0032797248 scopus 로고    scopus 로고
    • Anatomic evaluation of two different techniques for the percutaneous insertion of pedicle screws in the lumbar spine
    • Wiesner L, Kothe R, Ruther W. Anatomic evaluation of two different techniques for the percutaneous insertion of pedicle screws in the lumbar spine. Spine (Phila Pa 1976). 1999;24:1599-1603.
    • (1999) Spine (Phila Pa 1976) , vol.24 , pp. 1599-1603
    • Wiesner, L.1    Kothe, R.2    Ruther, W.3
  • 5
    • 0034099254 scopus 로고    scopus 로고
    • Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine
    • Wiesner L, Kothe R, Schulitz KP, et al. Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine. Spine (Phila Pa 1976). 2000;25:615-621.
    • (2000) Spine (Phila Pa 1976) , vol.25 , pp. 615-621
    • Wiesner, L.1    Kothe, R.2    Schulitz, K.P.3
  • 6
    • 56649104914 scopus 로고    scopus 로고
    • Percutaneous iliac screw placement: Description of a new minimally invasive technique
    • Wang MY, Ludwig SC, Anderson DG, et al. Percutaneous iliac screw placement: description of a new minimally invasive technique. Neurosurg Focus. 2008;25:E17.
    • (2008) Neurosurg Focus. , vol.25
    • Wang, M.Y.1    Ludwig, S.C.2    Anderson, D.G.3
  • 7
    • 34447550708 scopus 로고    scopus 로고
    • Percutaneous surgical treatment of chance fractures using cannulated pedicle screws. Report of two cases
    • Schizas C, Kosmopoulos V. Percutaneous surgical treatment of chance fractures using cannulated pedicle screws. Report of two cases. J Neurosurg Spine. 2007;7:71-74.
    • (2007) J Neurosurg Spine , vol.7 , pp. 71-74
    • Schizas, C.1    Kosmopoulos, V.2
  • 8
    • 34250664648 scopus 로고    scopus 로고
    • Five-year follow-up examination after purely minimally invasive posterior stabilization of thoracolumbar fractures: A comparison of minimally invasive percutaneously and conventionally open treated patients
    • Wild MH, Glees M, Plieschnegger C, et al. Five-year follow-up examination after purely minimally invasive posterior stabilization of thoracolumbar fractures: a comparison of minimally invasive percutaneously and conventionally open treated patients. Arch Orthop Trauma Surg. 2007;127:335-343.
    • (2007) Arch Orthop Trauma Surg , vol.127 , pp. 335-343
    • Wild, M.H.1    Glees, M.2    Plieschnegger, C.3
  • 9
    • 34247893896 scopus 로고    scopus 로고
    • Percutaneous pedicle screw instrumentation for temporary internal bracing of nondisplaced bony Chance fractures
    • Beringer W, Potts E, Khairi S, et al. Percutaneous pedicle screw instrumentation for temporary internal bracing of nondisplaced bony Chance fractures. J Spinal Disord Tech. 2007;20:242-247.
    • (2007) J Spinal Disord Tech , vol.20 , pp. 242-247
    • Beringer, W.1    Potts, E.2    Khairi, S.3
  • 10
    • 67649197402 scopus 로고    scopus 로고
    • Minimally invasive spine stabilisation with long implants
    • suppl 1)
    • Logroscino CA, Proietti L, Tamburrelli FC. Minimally invasive spine stabilisation with long implants. Eur Spine J. 2009;18 (suppl 1):75-81.
    • (2009) Eur Spine J , vol.18 , pp. 75-81
    • Logroscino, C.A.1    Proietti, L.2    Tamburrelli, F.C.3
  • 11
    • 67649158715 scopus 로고    scopus 로고
    • Minimally invasive percutaneous fixation in the treatment of thoracic and lumbar spine fractures
    • Palmisani M, Gasbarrini A, Brodano GB, et al. Minimally invasive percutaneous fixation in the treatment of thoracic and lumbar spine fractures. Eur Spine J. 2009;18 (suppl 1):71-74.
    • (2009) Eur Spine J. , vol.18 , Issue.SUPPL. 1 , pp. 71-74
    • Palmisani, M.1    Gasbarrini, A.2    Brodano, G.B.3
  • 12
    • 1842459414 scopus 로고    scopus 로고
    • Surgical treatment of traumatic fractures of the thoracic and lumbar spine: A systematic review of the literature on techniques, complications, and outcome
    • Verlaan JJ, Diekerhof CH, Buskens E, et al. Surgical treatment of traumatic fractures of the thoracic and lumbar spine: a systematic review of the literature on techniques, complications, and outcome. Spine (Phila Pa 1976). 2004;29:803-814.
    • (2004) Spine (Phila Pa 1976) , vol.29 , pp. 803-814
    • Verlaan, J.J.1    Diekerhof, C.H.2    Buskens, E.3
  • 13
    • 78751571290 scopus 로고    scopus 로고
    • Clinical accuracy of computerassisted two-dimensional fluoroscopy for the percutaneous placement of lumbosacral pedicle screws
    • Ravi B, Zahrai A, Rampersaud R. Clinical accuracy of computerassisted two-dimensional fluoroscopy for the percutaneous placement of lumbosacral pedicle screws. Spine (Phila Pa 1976). 2011;36:84-91.
    • (2011) Spine (Phila Pa 1976) , vol.36 , pp. 84-91
    • Ravi, B.1    Zahrai, A.2    Rampersaud, R.3
  • 14
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomised controlled clinical study in 100 consecutive patients
    • Laine T, Lund T, Ylikoski M, et al. Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J. 2000;9:235-240.
    • (2000) Eur Spine J. , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikoski, M.3
  • 15
    • 64749091332 scopus 로고    scopus 로고
    • Percutaneous placement of pedicle screws in the lumbar spine using a bone mounted miniature robotic system: First experiences and accuracy of screw placement
    • Pechlivanis I, Kiriyanthan G, Engelhardt M, et al. Percutaneous placement of pedicle screws in the lumbar spine using a bone mounted miniature robotic system: first experiences and accuracy of screw placement. Spine (Phila Pa 1976). 2009;34:392-398.
    • (2009) Spine (Phila Pa 1976) , vol.34 , pp. 392-398
    • Pechlivanis, I.1    Kiriyanthan, G.2    Engelhardt, M.3
  • 16
    • 1842564006 scopus 로고    scopus 로고
    • Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: A proposed systematic approach to improve accuracy of interpretation
    • Learch TJ, Massie JB, Pathria MN, et al. Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation. Spine (Phila Pa 1976). 2004;29:767-773.
    • (2004) Spine (Phila Pa 1976) , vol.29 , pp. 767-773
    • Learch, T.J.1    Massie, J.B.2    Pathria, M.N.3
  • 17
    • 36148956161 scopus 로고    scopus 로고
    • Analysis of anatomic morphometry of the pedicles and the safe zone for through-pedicle procedures in the thoracic and lumbar spine
    • Lien SB, Liou NH, Wu SS. Analysis of anatomic morphometry of the pedicles and the safe zone for through-pedicle procedures in the thoracic and lumbar spine. Eur Spine J. 2007;16:1215-1222.
    • (2007) Eur Spine J. , vol.16 , pp. 1215-1222
    • Lien, S.B.1    Liou, N.H.2    Wu, S.S.3
  • 18
    • 14844353716 scopus 로고    scopus 로고
    • Accurate determination of isthmus of lumbar pedicle: A morphometric study using reformatted computed tomographic images
    • Li B, Jiang B, Fu Z, et al. Accurate determination of isthmus of lumbar pedicle: a morphometric study using reformatted computed tomographic images. Spine (Phila Pa 1976). 2004;29: 2438-2444.
    • (2004) Spine (Phila Pa 1976) , vol.29 , pp. 2438-2444
    • Li, B.1    Jiang, B.2    Fu, Z.3
  • 19
    • 34248550738 scopus 로고    scopus 로고
    • Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization
    • Schizas C, Michel J, Kosmopoulos V, et al. Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization. Eur Spine J. 2007;16:613-617.
    • (2007) Eur Spine J. , vol.16 , pp. 613-617
    • Schizas, C.1    Michel, J.2    Kosmopoulos, V.3
  • 20
    • 21344451136 scopus 로고    scopus 로고
    • Minimally invasive transforaminal lumbar interbody fusion (TLIF): Technical feasibility and initial results
    • Schwender JD, Holly LT, Rouben DP, et al. Minimally invasive transforaminal lumbar interbody fusion (TLIF): technical feasibility and initial results. J Spinal Disord Tech. 2005;18 (suppl):S1-S6.
    • (2005) J Spinal Disord Tech , vol.18 , Issue.SUPPL.
    • Schwender, J.D.1    Holly, L.T.2    Rouben, D.P.3
  • 21
    • 33750067659 scopus 로고    scopus 로고
    • Minimally invasive transmuscular pedicle screw fixation of the thoracic and lumbar spine
    • discussion ONS6-ONS7
    • Ringel F, Stoffel M, Stuer C, et al. Minimally invasive transmuscular pedicle screw fixation of the thoracic and lumbar spine. Neurosurgery. 2006;59:ONS361-ONS366; discussion ONS6-ONS7.
    • (2006) Neurosurgery. , vol.59
    • Ringel, F.1    Stoffel, M.2    Stuer, C.3
  • 22
    • 56649109474 scopus 로고    scopus 로고
    • Percutaneous techniques for minimally invasive posterior lumbar fusion
    • Harris EB, Massey P, Lawrence J, et al. Percutaneous techniques for minimally invasive posterior lumbar fusion. Neurosurg Focus. 2008;25:E12.
    • (2008) Neurosurg Focus. , vol.25
    • Harris, E.B.1    Massey, P.2    Lawrence, J.3
  • 23
    • 83255192144 scopus 로고    scopus 로고
    • Facet violation with the placement of percutaneous pedicle screws
    • Patel PD, Graziano GP, Vanderhave KL, et al. Facet violation with the placement of percutaneous pedicle screws. Spine (Phila Pa 1976). 2011;36:E1749-E1752.
    • (2011) Spine (Phila Pa 1976) , vol.36
    • Patel, P.D.1    Graziano, G.P.2    Vanderhave, K.L.3
  • 24
    • 33846683025 scopus 로고    scopus 로고
    • Pedicle screw placement accuracy: A meta-analysis
    • Kosmopoulos V, Schizas C. Pedicle screw placement accuracy: a meta-analysis. Spine (Phila Pa 1976). 2007;32:E111-E120.
    • (2007) Spine (Phila Pa 1976) , vol.32
    • Kosmopoulos, V.1    Schizas, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.