메뉴 건너뛰기




Volumn 23, Issue 7, 2014, Pages 360-364

Problems with use of a Foley catheter in enteral tube feeding

Author keywords

Community; Consent; Enteral nutrition; Foley catheter; Professional responsibility; Unlicensed product

Indexed keywords

ARTICLE; BODY IMAGE; CATHETERIZATION; COST; ECONOMICS; ENTERIC FEEDING; EQUIPMENT; ETHICS; HUMAN; METHODOLOGY; NATIONAL HEALTH SERVICE; PROFESSIONAL COMPETENCE; QUALITY OF LIFE; UNITED KINGDOM;

EID: 84902080566     PISSN: 09660461     EISSN: None     Source Type: Journal    
DOI: 10.12968/bjon.2014.23.7.360     Document Type: Article
Times cited : (10)

References (26)
  • 1
    • 23944522379 scopus 로고    scopus 로고
    • A retrospective survey of tube-related complications in patients receiving long-term home enteral nutrition
    • DOI 10.1007/s10620-005-2923-z
    • Crosby J, Duerksen D. (2005) A retrospective survey of tube related complications in patients receving long term home enteral nutrition. Dig Dis Sci 50 (9): 1712-7 (Pubitemid 41203670)
    • (2005) Digestive Diseases and Sciences , vol.50 , Issue.9 , pp. 1712-1717
    • Crosby, J.1    Duerksen, D.2
  • 2
    • 0036627150 scopus 로고    scopus 로고
    • Unusual complications of ballooned feeding tubes
    • Date RS, Das N, Bateson P.G. (2002) Unusual complications of ballooned feeding tubes. Ir Med J 95 (6): 181-2 (Pubitemid 36105231)
    • (2002) Irish Medical Journal , vol.95 , Issue.6 , pp. 181-182
    • Date, R.S.1    Das, N.2    Bateson, P.G.3
  • 3
    • 79953853865 scopus 로고    scopus 로고
    • Exploring urinary catheters: The perspectives of patients and nurses
    • De Jaeger (2011) Exploring urinary catheters: the perspectives of patients and nurses. Br J Nurs 20(7): 400-8
    • (2011) Br J Nurs , vol.20 , Issue.7 , pp. 400-408
    • De Jaeger1
  • 4
    • 80054986501 scopus 로고    scopus 로고
    • Nutrition: Safe practice in adult enteral tube feeding
    • Fletcher J (2011) Nutrition: safe practice in adult enteral tube feeding. Br J Nurs 20(19): 1234-9
    • (2011) Br J Nurs , vol.20 , Issue.19 , pp. 1234-1239
    • Fletcher, J.1
  • 5
    • 34447525297 scopus 로고    scopus 로고
    • Home enteral feeding Part 1: An overview
    • Fogg L (2007) Home Enteral feeding part 1: an overview. Br J Community Nurs 12(6): 246-52
    • (2007) Br J Community Nurs , vol.12 , Issue.6 , pp. 246-252
    • Fogg, L.1
  • 6
    • 80755184828 scopus 로고    scopus 로고
    • Prescription of controlled drugs by non medical prescribers
    • Griffith R,Tengah C (2011) Prescription of controlled drugs by non medical prescribers. Br J Community Nurs 16(11): 558-62
    • (2011) Br J Community Nurs , vol.16 , Issue.11 , pp. 558-562
    • Griffith, R.1    Tengah, C.2
  • 7
    • 0035114255 scopus 로고    scopus 로고
    • The challenges of innovation in the organization of home enteral tube feeding
    • DOI 10.1046/j.1365-277X.2001.00270.x
    • Howard P, Bowen N. (2001) The challenges of innovation in the organization of home enteral tube feeding. J Hum Nutr Diet 14:3-11 (Pubitemid 32166463)
    • (2001) Journal of Human Nutrition and Dietetics , vol.14 , Issue.1 , pp. 3-11
    • Howard, P.1    Bowen, N.2
  • 8
    • 84885677294 scopus 로고    scopus 로고
    • Joint Formulary Committee September. BMJ Group and Pharmaceutical Press
    • Joint Formulary Committee (2013) British National Formulary 66. September. BMJ Group and Pharmaceutical Press.
    • (2013) British National Formulary 66
  • 9
    • 0028230718 scopus 로고
    • Comparison of Foley catheter as a replacement gastrostomy tube with commercial replacement gastrostomy tube: A prospective randomized trial
    • Kadakia SC, Cassaday M, Shaffer R.T. (1994) Comparison of Foley catheter as a replacement gastrostomy tube with commercial replacement gastrostomy tube: a prospective randomised trial. Gastrointest Endosc 40(2 part 1):188-93 (Pubitemid 24129197)
    • (1994) Gastrointestinal Endoscopy , vol.40 , Issue.2 , pp. 188-193
    • Kadakia, S.C.1    Cassaday, M.2    Shaffer, R.T.3
  • 10
    • 79957505831 scopus 로고    scopus 로고
    • Reduction of inappropriate urinary catheter use at a veterans affairs hospital through a multifaceted quality improvement project
    • doi: 10.1093/cid/cir188
    • Knoll BM, Wright D, Ellingson L et al (2011) Reduction of inappropriate urinary catheter use at a veterans affairs hospital through a multifaceted quality improvement project. Clin Infect Dis 52(11): 1283-90 doi: 10.1093/cid/cir188
    • (2011) Clin Infect Dis , vol.52 , Issue.11 , pp. 1283-1290
    • Knoll, B.M.1    Wright, D.2    Ellingson, L.3
  • 11
    • 0141634255 scopus 로고    scopus 로고
    • Home enteral-tube feeding: The changing role of the dietitian
    • DOI 10.1079/PNS2003273
    • Madigan SM (2003) Home enteral-tube feeding: The changing role of the dietitian. Proc Nutr Soc 62: 761-3 (Pubitemid 37152862)
    • (2003) Proceedings of the Nutrition Society , vol.62 , Issue.3 , pp. 761-763
    • Madigan, S.M.1
  • 12
    • 0036072286 scopus 로고    scopus 로고
    • Assessing the dietetic needs of different patient groups receiving enteral tube feeding in primary care
    • DOI 10.1046/j.1365-277X.2002.00361.x
    • Madigan SM, O'Neill S, Clarke J, L'Estrange F, MacAuley D.C. (2002) Assessing the dietetic needs of different patient groups receiving enteral tube feeding in primary care. J Hum Nutr Diet 15(3): 179-84 (Pubitemid 34661894)
    • (2002) Journal of Human Nutrition and Dietetics , vol.15 , Issue.3 , pp. 179-184
    • Madigan, S.M.1    O'Neill, S.2    Clarke, J.3    L'Estrange, F.4    MacAuley, D.C.5
  • 13
  • 14
    • 84902165851 scopus 로고    scopus 로고
    • Medicines and Healthcare Product Regulatory Agency 4 January (accessed 25 March 2014)
    • Medicines and Healthcare Product Regulatory Agency (2010) Medical Device Alert Ref: MDA/2010/001. 4 January. http://tinyurl.com/oneuy7p (accessed 25 March 2014)
    • (2010) Medical Device Alert Ref: MDA/2010/001
  • 17
    • 65549130997 scopus 로고    scopus 로고
    • Nursing and Midwifery Council (accessed 25 March 2014)
    • Nursing and Midwifery Council (2010) Standards for Medicines Management. http://tinyurl.com/ck8fk4z (accessed 25 March 2014)
    • (2010) Standards for Medicines Management
  • 18
    • 79951708522 scopus 로고    scopus 로고
    • Nutricia Nutricia, Trowbridge
    • Nutricia (2009) Ancillary Price list. Nutricia, Trowbridge
    • (2009) Ancillary Price List
  • 19
    • 84864842817 scopus 로고    scopus 로고
    • Managing patients on enteral feeding tubes in the community
    • Ojo O (2010) Managing patients on enteral feeding tubes in the community. Br J Community Nurs 15(Suppl): S6-13
    • (2010) Br J Community Nurs , vol.15 , Issue.SUPPL.
    • Ojo, O.1
  • 20
    • 79951687048 scopus 로고    scopus 로고
    • Balloon gastrostomy tubes for long-term feeding in the community
    • Ojo O (2011) Balloon gastrostomy tubes for long-term feeding in the community. Br J Nurs 20: 34-8
    • (2011) Br J Nurs , vol.20 , pp. 34-38
    • Ojo, O.1
  • 21
    • 84870589912 scopus 로고    scopus 로고
    • The impact of changes in health and social care on enteral feeding in the community
    • doi: 10.3390/nu4111709
    • Ojo O (2012) The impact of changes in health and social care on enteral feeding in the community. Nutrients 4(11): 1709-22 doi: 10.3390/nu4111709.
    • (2012) Nutrients , vol.4 , Issue.11 , pp. 1709-1722
    • Ojo, O.1
  • 23
    • 27144462643 scopus 로고    scopus 로고
    • Consent and the use of Foley catheters in epistaxis
    • DOI 10.1258/002221505774481318
    • Pellard S, Boyce J, Ingrams D.R. (2005) Consent and the use of Foley catheters in epistaxis. J Laryngol Otol 119(10): 822-24 (Pubitemid 41502921)
    • (2005) Journal of Laryngology and Otology , vol.119 , Issue.10 , pp. 822-824
    • Pellard, S.1    Boyce, J.2    Ingrams, D.R.3
  • 24
    • 0025890439 scopus 로고
    • Foley catheter gastrostomy tube migration: Small bowel obstruction relieved by percutaneous balloon aspiration
    • Pereira MC, Mersich K. (1991) Foley catheter gastrostomy tube migration: small bowel obstruction relieved by percutaneous balloon aspiration. Gastrointest Endosc 37: 372-4
    • (1991) Gastrointest Endosc , vol.37 , pp. 372-374
    • Pereira, M.C.1    Mersich, K.2
  • 25
    • 79952657151 scopus 로고    scopus 로고
    • Foley catheter enterostomy for postoperative bowel perforation: An effective source control
    • doi: 10.1007/s00268-010-0741-8
    • Tøttrup A (2010) Foley catheter enterostomy for postoperative bowel perforation: An effective source control. World J Surg 34(11): 2752-4 doi: 10.1007/s00268-010-0741-8.
    • (2010) World J Surg , vol.34 , Issue.11 , pp. 2752-2754
    • Tøttrup, A.1
  • 26


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.